HomeMy WebLinkAboutCivil Plans - Site Plan3N00°12'56"E 45.00'N00°12'56"E 80.00'N05°09'37"E 55.19'N45°49'55"E35.16'S88°58'53"E 91.10'S00°12'56"W 120.00'S88°58'53"E 49.56'
S88°58'53"E 69.11'
N88°58'53"W 75.31'
N88°58'53"W 117.00'N00°12'56"E21.00'N88°58'53"W 28.00'
S88°58'53"E
19.01'FORMER INDIANA UNION TRACTION CO.ROW (NOW ABANDON) SHOWN PER PLATDEED RECORD 106 PAGE 5INSTR.#1915011024N00°12'56"E
14.00'
POINT OF
COMMENCEMENT
DELTA=0°37'27"
R=3848.33'
T=20.96'
L=41.92'
CH BRG=S16°20'15"W
CH LEN=41.92'
DELTA=1°15'56"
R=3782.33'
T=41.78'
L=83.55'
CH BRG=S15°42'03"W
CH LEN=83.55'COLLEGE AVENUEE 105TH STREET
JESSUP BOULEVARDP.O.B.
5 7
4' PROPOSED ROW
STAFF
PARKING
PARENT/PUBLIC
PARKING
9
10 5' FRONT BSLP3
P2
P1
H1
A1
A4
A4
A2
A2
H2
H2
P4
P4
P5
P5
P5
P5
P5
A3
A3
A5
A5
A5
A6
A6
A2
A6
P4
P1
H1
P5
A2
A7
A6A2
A5
A5
A2
A2
S1
S3
S2
S2
S2
S2
P3 P2
S3
S1
SITE DATA
SITE AREA = 0.84 AC
BUILDING AREA = 6,887.46 SF
PERCENT IMPERVIOUS = 68.69%
ZONING = B-1 (HP-OL)
FRONT YARD BSL REQUIRED = 5 FT
FRONT YARD BUFFER = 5 FT
REAR YARD BSL REQUIRED:
NEXT TO RESIDENCE = 15 FT
NEXT TO BUSINESS = 10 FT
REAR YARD BUFFER = 5 FT
SIDE YARD BSL REQUIRED = 10 FT
SIDE YARD BUFFER = 5 FT
PARKING REQUIRED:
PARKING REQUIREMENT: 1 PER 1,000 SF
OF GROSS FLOOR AREA
PARKING REQUIRED = 7 SPACES
PARKING DIMENSIONS = 9' x 20' OR 10'x18'
BIKE PARKING REQUIRED = 2 SPACES
PARKING PROVIDED:
30 - STANDARD SPACES
1 - ADA SPACES
31 - TOTAL SPACES
SITE PLAN NOTES
PAVEMENT
STANDARD DUTY CONCRETE WITH 1' CHAMFERED CORNERS
RIGHT-OF-WAY CONCRETE WITH 1' CHAMFERED CORNERS
MATCH EXISTING PAVEMENT
RIGHT-OF-WAY CURB BY OTHERS - CONTRACTOR TO COORDINATE
WITH THE CITY OF CARMEL
EXISTING ASPHALT PAVING TO REMAIN.
HARDSCAPE
CONCRETE SIDEWALK
RIGHT-OF-WAY IMPROVEMENTS BY OTHERS. CONTRACTOR TO
COORDINATE WITH CITY OF CARMEL ROADWAY PROJECT
ACCESSORIES
BIKE RACK
6' WHITE PVC PRIVACY FENCE
EXISTING WOOD PRIVACY FENCE TO REMAIN
4' BLACK DECORATIVE FENCE/RAILING
4' WHITE PVC PRIVACY FENCE
FENCE GATE
TRASH STORAGE AREA
SIGNAGE & MARKINGS
ACCESSIBLE PARKING SPACE - EXISTING SIGNS TO BE RELOCATED
4" PAINTED WHITE SOLID LINES (TYP)
4" PAINTED WHITE SOLID LINE ISLAND
ELECTRICAL RISER
GUY ANCHOR
ELECTRIC JUNCTION BOX
ORNAMENTAL LIGHT
GENERATOR
STREET LIGHT
ELECTRIC MANHOLE
ELECTRIC OUTLET
UTILITY POLE
UTILITY POLE W/ TRANSFORMER
TRANSFORMER
COMMUNICATIONS JUNCTION BOX
COMMUNICATIONS MANHOLE
COMMUNICATIONS PEDESTAL
RIGHT OF WAY LINE
FENCE
GUARD RAIL
BUILDING SETBACK LINE
BOUNDARY LINE
CISTERN
DRINKING FOUNTAIN
FIRE DEPT HOOKUP
FIRE HYDRANT
POST INDICATOR VALVE
CHILLED WATER MANHOLE
WATER MANHOLE
SPRINKLER CONTROL BOX
SPRINKLER CONTROL VALVE
SPRINKLER
SPIGOT
WELL HEAD
WATER METER
WATER VALVE
GAS METER
GAS VALVE
ELECTRIC METER
LIQUID PROPANE GAS TANK
MONITORING WELL
TRAFFIC SIGNAL POLE
TRAFFIC SIGNAL
BOLLARD
FLAG POLE
PARKING METER
POST
SIGN
PARKING WHEEL STOP
DOWN SPOUT
ACCESSIBLE SPACE
GATE POST
COMMUNICATIONS RISER
STORM CLEANOUT
BEEHIVE INLET
CURB INLET
FLOOR DRAIN
ROUND INLET
SQUARE INLET
STORM MANHOLE
SANITARY SEWER CLEANOUT
LIFT STATION
SANITARY SEWER MANHOLE
SANITARY STUB MARKER
SEPTIC TANK
PARKING LOT LIGHT (1 HEAD)
PARKING LOT LIGHT (3 HEAD)
PARKING LOT LIGHT (4 HEAD)
PARKING LOT LIGHT (2 HEAD)
CONCRETE PAVEMENT
DISTRIBUTION BOX
ROW RIGHT OF WAY
BSL BUILDING SETBACK LINE
ESMT EASEMENT
D.&U.E.DRAINAGE AND UTILITY EASEMENT
FFE FINISH FLOOR ELEVATION
12 PARKING COUNT
PAVEMENT
SITE PLAN LEGEND
UTILITIES
ABBREVIATIONS
OTHER
LINE TYPES
SECTION LINE W240361 C200 SITEC200SITE PLANW24.0361GBW24.036105/01/2024ECGBTHE FAMILY PLACE ACADEMY10455 N. COLLEGE AVENUE, CARMEL, IN 46280P1
P2
P3
H1
H2
A1
A2
S1
10 9abcd 8 7 6efgh109876
5 4 3 2 Part of the NW/4 of Section 12, Township 17 North, Range 3 East, Clay Township, Hamilton County, Indiana1 PREPARED FOR:PROJECT NO.
SHEET NO.abcd5 4 3 2
e1
fhAPPROVAL PENDINGNOT FOR CONSTRUCTIONgALLAN H. WEIHE, P.E., L.S. - FOUNDER10505 N. College AvenueIndianapolis, Indiana 46280weihe.netBuild with confidence.SMENGINEERS317 | 846 - 6611800 | 452 - 6408317 | 843 - 0546 faxWEIHELand Surveying | Civil EngineeringLandscape Architecturexx/xx/20xxPROJECT NO.:REVISIONS AND ISSUESDATEBYDWG NAME:DESIGNED BY:DRAWN BY:CHECKED BY:DATE:W
S
N
E
Know what's below.
before you dig.Call
R
50' MAXIMUM
CURB JOINT DETAIL
TOP OF CURB
(NO SCALE)
NOTE: MAXIMUM TRANSVERSE CONTRACTION JOINT DISTANCE 10 FEET
FOR TANGENT SECTIONS AND 5 FEET FOR RADIUS SECTIONS.
PAVEMENT
TRANSVERSE EXPANSION JOINTS
TRANSVERSE CONTRACTION JOINTS
BOTTOM
OF CURB
24"
A-A
Section B-B Section A-A
Diagram 1: Bicycle Rack Type
Mounting Surface
Diagram 2: Bicycle Parking Location and Design
BICYCLE PARKING DETAIL
(NO SCALE)
STANDARD DUTY CONCRETE PAVING SECTION
(NO SCALE)
4"-#53 AGGREGATE (INDOT)
4" CONC. (4000 PSI)
W/FIBER ADDITIVE
PREPARED SUBGRADE COMPACTED PER INDOT
STANDARD SPECIFICATIONS. MAY REQUIRE
TREATMENT BEFORE PAVING.
P4
NOTE
MULTI-USE PATH AND NEW CURB AND
GUTTER ALONG COLLEGE AVE. ARE PART
OF THE PROPOSED STREETSCAPE
IMPROVEMENTS BY OTHERS.
CONTRACTOR TO COORDINATE WITH THE
CITY OF CARMEL.
P5
A3
A4
A5
A6
A7
S2
S3
NOTE
CONTRACTOR TO VERIFY GRADE OF
SIDEWALKS THAT CONNECT WITH
PROPOSED STREETSCAPE
IMPROVEMENTS BY OTHERS. IF 5% OR
GREATER, CONTRACTOR TO PROVIDE
ADA COMPLIANT HANDRAIL.