Loading...
HomeMy WebLinkAboutArchitectural Drawings - 2nd Floor PlanUPUPUP1A2002A2003A2004A2005 YEAR OLDCLASSROOM201KITCHEN 2214CLOSET212HALL205STORAGE ROOM215LAUNDRY/JANROOM211STAIRS2CLOSET20436 TO 48 MONTHOLDCLASSROOM209RESTROOM210A4001A4021COAT ROOM202KITCHEN220STAIRS121322021404IW-1IW-1100909EMPLOYEEBREAK ROOM208STAFF RR207HALLWAY20609209206LARGE GROUPTRAINING ROOM217208215216205203210STAFFRESTROOM222JAN.221STORAGE ROOM218FOOD STORAGE216219218221222STORAGE203IW-1IW-1IW-1IW-1IW-1IW-1IW-1IW-1IW-1IW-118'-10 1/4"3 1/2"7'-4 1/4"3 1/2"13'-10 3/8"3 1/2"4'-6 1/8"3 1/2"5'-6 3/4"7'-3 1/4"3 1/2"10'-5 3/8"5'-9 1/4"3 1/2"11'-11 3/8"34'-8"W/D4 YEAR OLDCLASSROOM213LOBBY2193 1/2"5'-8 1/2"2A. DO NOT SCALE DRAWINGS: USE ONLY WRITTEN DIMENSIONS. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO VERIFY THAT ALL DIMENSIONS OF THE PROPOSED STRUCTURE ARE CORRECT BEFORE BEGINNING WORK.B. ALL STUD WALLS SHALL HAVE STUDS SPACED AT 16" ON CENTER UNLESS NOTED OTHERWISE. SEE WALL ASSEMBLIES FOR ADDITIONAL CONSTRUCTION INFORMATION. C. ALL WORK SHALL BE COMPLETED IN STRICT ACCORDANCE WITH ALL APPLICABLE CODES.D. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO INFORM KJG ARCHITECTURE, INC.OF ANY UNSAFE CONDITION OR CODE VIOLATION, EITHER STATE OR LOCAL, PRIOR TO THE START OF CONSTRUCTION.E. THE CONTRACTOR SHALL VERIFY AND COORDINATE ALL WORK WITH ALL TRADES (PLUMBING, ELECTRICAL, MECHANICAL, AND OTHERS ON THE JOB) TO ENSURE THAT ALL REQUIRED CLEARANCES ARE MADE PRIOR TO PROCEEDING WITH THE PROJECT, AND SHALL NOTIFY THE ARCHITECT OF ANY PROBLEMS OR CONFLICTS PRIOR TO THE START OF CONSTRUCTION.F. IF FIELD CONDITIONS EXIST THAT REQUIRE ALTERATIONS TO THESE PLANS, KJG ARCHITECTURE, INC.MUST BE NOTIFIED AT ONCE AND BEFORE ANY FURTHER CONSTRUCTION TAKES PLACE.G. SEE SHEET A000 FOR GENERAL ARCHITECTURAL CONSTRUCTION NOTES.H. REFER TO SHEET A220 SERIES INTERIOR ELEVATIONS FOR RESTROOM ACCESSORIES AND MOUNTING HEIGHTS.I. ALL FINISHES SHALL BE IN ACCORDANCE WITH OWNER APPROVED FINISHES. CONTRACTOR TO VERIFY ALL FINISHES WITH OWNER SELECTIONS PRIOR TO CONSTRUCTION.J. PROVIDE SOLID BLOCKING FOR ALL WALL-MOUNTED ITEMS, SUCH AS, BUT NOT LIMITED TO CABINETS, GRAB BARS, TOILET ACCESSORIES, AND SHELVING.GENERAL FLOOR PLAN NOTESGENERAL FLOOR PLAN LEGENDW12WALL ASSEMBLY TAG, REFER TO G010 SERIESW1202DOOR ASSEMBLY TAG, REFER TO A600 SERIESWINDOW ASSEMBLY TAG, REFER TO A600 SERIESIW-12X4 WOOD STUD, INSULATED5/8 INCH TYPE 'X' GYPSUM BOARD EACH SIDE OF2X4 WOOD STUDS SPACED AT 16 INCHES ONCENTER MAXIMUM WITH 3-1/2 INCH ACOUSTICGLASS FIBER BATT INSULATION.1-HOUR RATINGUL # U305INTERIOR FIRE PARTITIONSTC: 363 1/2"CLCL16" MAX.TYPE 'X' GYPSUM BOARD2X4 WOOD STUDSACOUSTIC INSULATIONIW-22X4 STUD, FINISH ONE SIDE5/8 INCH GYPSUM BOARD ONE SIDE (OCCUPANTSIDE) OF 2X4 WOOD FURRING SPACED AT 16INCHES ON CENTER MAXIMUM ATTACHED TOADJACENT WALL ASSEMBLY.NON-RATEDUL # N/AINTERIOR FURRING WALLSTC: -GYPSUM BOARD2X4 WOOD FURRINGOCCUPANT SIDE1 1/2"ADJACENT WALL ASSEMBLYEW-12X6 WOOD STUD, FIBER CEMENTSIDINGFIBER CEMENT LAP SIDING OVER 2" RIGID BOARDINSULATION, WEATHER RESISTANT COMMERICALBUILDING WRAP ON 7/16 INCH ORIENTED STANDBOARD (OSB) SHEATHING ATTACHED TO EXTERIORSIDE OF 6" METAL STUDS SPACED AT 16 INCHESON CENTER MAXIMUM WITH R-21 (5-1/2 INCH)KRAFT-BACKED (FACING INTERIOR) THERMALGLASS FIBER BATT INSULATION AND 5/8 INCH TYPE'X' GYPSUM BOARD INTERIOR SIDE.1-HOUR FIRE RATINGUL # U356RATED EXTERIOR WALLR-VALUE: 21GYPSUM BOARD2X6" WOOD STUDSTHERMAL BATT INSULATIONINTERIOR SIDEEXTERIOR SIDEEXTERIOR SHEATHINGWEATHER RESISTANT BARRIERFIBER CEMENT LAP SIDINGKRAFT-BACKINGRIGID BOARD INSULATIONIW-32X4 STUD, FINISH ONE SIDE5/8 INCH GYPSUM BOARD ONE SIDE (OCCUPANTSIDE) OF 2X4 WOOD STUDS SPACED AT 16 INCHESON CENTER MAXIMUM.NON-RATEDUL # N/AINTERIOR WALLSTC: -3 1/2"CLCL16" MAX.GYPSUM BOARD2X4 WOOD STUDSOCCUPANT SIDEOJYKELLNHDOGOG RESDRETE19600148No.ISTATE OFCARHETCITNAADNII•SHEET NUMBER:KJG ARCHITECTURE, INC.527 SAGAMORE PARKWAY WESTWEST LAFAYETTE, INDIANA 47906www.kjgarchitecture.com 765.497.4598PROJECT NUMBER:CHECKED BY:NO. DESCRIPTIONDATEThis is an original design, created by KJG Architecture, Inc. The concepts, ideas, plans and details are the sole property of KJG Architecture, Inc. None of the aforementioned shall be used by or disclosed to any person, firm or organization for any purpose without the prior written permission of KJG Architecture, Inc.PROFESSIONAL SEAL:DISCLAIMER:PROJECT DATE:SHEET REVISIONS:A102A2024.00605.08.2024SECOND FLOOR PLANRENOVATE BUILDING INTO NEW DAYCARE-REBID10455 NORTH COLLEGE AVENUECARMEL, INDIANA 46280HAMILTON COUNTYTHE FAMILY PLACE ACADEMYSCALE:1/8" = 1'-0"A1021NEW SECOND FLOOR PLAN FLOOR PLAN KEYNOTESKEY NOTE01 NEW CAST-IN-PLACE CONCRETE RAMP AND STOOP WITH FROST WALLS02 NEW WALL MOUNTED METAL HAND RAIL SYSTEM.03 NEW SURFACE MOUNTED METAL GUARD AND HAND RAIL SYSTEM04 NEW WALL MOUNTED METAL HAND RAIL SYSTEM.05 NEW CAST-IN-PLACE CONCRETE FLOOR SLAB.06 NEW 4" THICK CAST-IN-PLACE CONCRETE ADA COMPLIANT RAMP. 4000 PSI-AT 28DAYS CONCRETE, WITH W.W.F .W.I.6. x W.I.6. OVER 6" DEEP COMPACTEDAGGREGATE FILL.09 INFILL WINDOW OPENING. MATCH EXISTING WALL CONSTRUCTION.10 INFILL DOOR OPENING. MATCH EXISTING WALL CONSTRUCTION.11 INFILL DOOR PENING WITH 5/8" GYPSUM BOARD ON METAIL STUDS14 WALL HEIGHT IS TO BE 4'-O" AFF. AND TO SLOPE WITH THE RAMP. CAP WALL WITHWOOD TRIM.NFOR REVIEW ONLY NOT FOR CONSTRUCTION