HomeMy WebLinkAboutArchitectural Plans - Plumbing PlansPLUMBING ABBREVIATIONS
SANITARY SEWER
STORM DRAIN
VENT THRU ROOF
DOMESTIC COLD WATER
DOMESTIC HOT WATER RETURN
DOMESTIC HOT WATER
SS
SD
VTR
DCW
DHW
DHWR
FLOOR CLEAN-OUTFCO
GREASE WASTEGW
POINT OF CONNECTIONPOC
SHUT-OFF VALVESOV
GALLONS PER MINUTEGPM
INDIRECT WASTEIW
REQUIREDREQ'D
TYPICALTYP
CONDENSATE DRAINCD
EXISTING(E)
POINT OF REMOVALPOR
FIRE ALARM CONTROL PANELFACP
FIRE ALARM ANNUNCIATOR PANELFAAP
SHEET NUMBER:
KJG ARCHITECTURE, INC.
527 SAGAMORE PARKWAY WEST
WEST LAFAYETTE, INDIANA 47906
www.kjgarchitecture.com
765.497.4598
PROJECT NUMBER:CHECKED BY:
NO.DESCRIPTION DATE
This is an original design, created by KJG Architecture, Inc. The
concepts, ideas, plans and details are the sole property of KJG
Architecture, Inc. None of the aforementioned shall be used by
or disclosed to any person, firm or organization for any purpose
without the prior written permission of KJG Architecture, Inc.
PROFESSIONAL SEAL:
DISCLAIMER:
PROJECT DATE:
SHEET REVISIONS:
P001
Project Number SJS
3/11/2024PLUMBING NOTESRENOVATE EXISTING BUILDING INTO NEW DAYCARE10455 NORTH COLLEGE AVENUECARMEL, INDIANA 46280HAMILTON COUNTYTHE FAMILY PLACE ACADAMYPLUMBING GENERAL NOTES
NOTE
NUMBER NOTE
1 THE PLUMBING CONTRACTOR SHALL FURNISH ALL MATERIALS AND LABOR TO COMPLETE THE WORK INDICATED ON THE DRAWINGS AND SPECIFICATIONS.
2 ALL WORK SHALL BE COMPLETED IN COMPLIANCE WITH THE INTERNATIONAL PLUMBING CODE, AND OTHER STATE AND LOCAL CODES.
3 THE PLUMBING CONTRACTOR SHALL VERIFY ALL LOADS AND PIPE SIZES PRIOR TO STARTING WORK.
4 THE PLUMBING CONTRACTOR SHALL MAINTAIN ALL REQUIRED CLEARANCES AROUND PLUMBING EQUIPMENT, AND COORDINATE WITH OTHER TRADES TO MAINTAIN CODE
REQUIRED CLEARANCES.
5 FOR FIRE RATED WALLS AND CEILINGS, SEE ARCHITECTURAL DRAWINGS.
6 ALL PENETRATIONS THROUGH WALLS, ROOFS, AND FLOORS SHALL BE FIRE STOPPED.
7 THE PLUMBING CONTRACTOR SHALL COORDINATE WITH LOCAL UTILITY COMPANY, AND PROVIDE ALL LABOR AND MATERIAL, AND PAY FEES TO PROVIDE A COMPLETE
PLUMBING SYSTEM.
8 FOR FIXTURE HEIGHT AND ACCESSIBILITY REQUIREMENTS, SEE ARCHITECTURAL DRAWINGS.
9 ALL INVERT ELEVATIONS (TOP OF PIPE) REPRESENTED BY - X.XX FT. ARE BELOW FINISHED FLOOR ELEVATION.
10 COORDINATE FIXTURE AND EQUIPMENT LOCATIONS, AND UTILITY CONNECTIONS, WITH OTHER TRADES.
11 ADA WATER CLOSET HANDLE TO BE LOCATED ON ACCESSIBLE SIDE.
PLUMBING FIXTURE SCHEDULE
CALLOUT TYPE MANUFACTURER MODEL DESCRIPTION
GT-1 GREASE TRAP WATTS WD-104 7 GPM, 14 LBS GREASE CAPACITY, EPOXY COATED INSIDE AND OUT
WC-1 WATER CLOSET - ADA AMERICAN STANDARD CADET ADA, FLOOR MOUNTED, FLUSH TANK, 1.28 GPF, VITREOUS CHINA, WITH EVERCLEAN, ELONGATED, SYPHON JET
L-1 LAVATORY AMERICAN STANDARD DECLYN ADA, WALL MOUNT, VITREOUS CHINA, 4" CENTER HOLE, AMERICAN STANDARD COLONY PRO, 0.5 GPM, SINGLE HANDLE FAUCET, TEMPERING VALVE FOR 110 F MAX. DHW
L-2 LAVATORY AMERICAN STANDARD DECLYN WALL MOUNT, VITREOUS CHINA, 4" CENTER HOLE, AMERICAN STANDARD COLONY PRO, 0.5 GPM, SINGLE HANDLE FAUCET, TEMPERING VALVE FOR 110 F MAX. DHW
MS-1 MOP SINK FIAT MSBID2424 24"x24"x10" DEEP, MOLDED STONE, 2.2 GPM, 3" DRAIN, WALL FAUCET WITH WALL BRACKET AND PAIL HOOK
HS-1 HAND SINK REGENCY 600HS17 17"x15", WALL MOUNTED, 20 GAUGE STAINLESS STEEL, WITH GOOSENECK FAUCET, 1.5 GPM
FD-1 FLOOR DRAIN WATTS FD-100-A ROUND, 2" DRAIN, EPOXY COATED CAST IRON, ADJUSTABLE STRAINER
Revision 1 7-17-2024
DN
UP
DN
DN
DN
DN
OFFICE
ENTRANCE
101
WAITING AREA
102
EXISTING OFFICE
103
EXISTING
CONFERENCE
ROOM
104
TOUR ROOM
106
INFANT ROOM 2
118
KITCHEN
117
EXISTING STAIR
S1
MAIN ENTRANCE
108
SECURITY
STATION
109
EXISTING STAIR
S2
EXISTING MECH
ROOM
113
13 TO 30 MONTH
OLD CLASSROOM
121
EMPLOYEE
TRAINING ROOM
122
STORAGE
ROOM
120
EMPLOYEE
BREAK ROOM
130
JAN CLOSET
128
CLOSET
129
MECH ROOM
127
30 TO 36 MONTH
OLD CLASSROOM
124
LAUNDRY
ROOM
127
RESTROOM
125
EMPLOYEE
KITCHEN
126
HS-1
HS-1
FCO
2"ø SS
4"ø SS
4"ø SS
4"ø SS
2"ø SS
P401
1
FCO
3"ø SS
WC-1
FCO
FD-1
3"ø SS
MS-1
GT-1
5 YEAR OLD
CLASSROOM
201
COAT ROOM
202
KITCHEN 2
214
HALLWAY
205
LAUNDRY/JAN
ROOM
211
36 TO 48 MONTH
OLD CLASSROOM
209
STORAGE ROOM
215
STAIR
S2
P401
2
P401
3
KITCHEN
220
L-1
L-2
FCO
FD-1
HS-1
3"ø SS
KS-1
FCO
GT-1
SHEET NUMBER:
KJG ARCHITECTURE, INC.
527 SAGAMORE PARKWAY WEST
WEST LAFAYETTE, INDIANA 47906
www.kjgarchitecture.com
765.497.4598
PROJECT NUMBER: CHECKED BY:
NO. DESCRIPTION DATE
This is an original design, created by KJG Architecture, Inc. The
concepts, ideas, plans and details are the sole property of KJG
Architecture, Inc. None of the aforementioned shall be used by
or disclosed to any person, firm or organization for any purpose
without the prior written permission of KJG Architecture, Inc.
PROFESSIONAL SEAL:
DISCLAIMER:
PROJECT DATE:
SHEET REVISIONS:
P101
Project Number SJS
3/11/2024PLUMBING FLOOR PLANS - DWVRENOVATE EXISTING BUILDING INTO NEW DAYCARE10455 NORTH COLLEGE AVENUECARMEL, INDIANA 46280HAMILTON COUNTYTHE FAMILY PLACE ACADAMYKEYNOTES:
NO WORK. EXISTING PLUMBING SYSTEMS TO REMAIN.
SANITARY DOWN TO FIRST FLOOR. SEE DETAIL 1/P101 FOR CONTINUATION.
CONNECT NEW SS TO EXISTING SS. CONTRACTOR TO VERIFY EXISTING PIPE
SIZE AND LOCATION.
SANITARY FROM THE SECOND FLOOR. ROUTE UNDER FIRST FLOOR SLAB.
CONTRACTOR TO VERIFY CONDITION AND LOCATION OF EXISTING
UNDERGROUNG SS PIPE.
1/8" = 1'-0"
1 PLUMBING FIRST FLOOR PLAN - DWV
1/8" = 1'-0"
2 PLUMBING SECOND FLOOR PLAN - DWV
EXISING SS
EXISING SS
1
2
3
3
4
1
11
2
2
4
5
3
4
3
Revision 1 7-17-2024
5
3
3
3
DN
UP
DN
DN
DN
DN
OFFICE
ENTRANCE
101
WAITING AREA
102
EXISTING OFFICE
103
EXISTING
CONFERENCE
ROOM
104
TOUR ROOM
106
INFANT ROOM 2
118
KITCHEN
117EXISTING STAIR
S1
MAIN ENTRANCE
108
SECURITY
STATION
109
EXISTING STAIR
S2
EXISTING MECH
ROOM
113
13 TO 30 MONTH
OLD CLASSROOM
121
EMPLOYEE
TRAINING ROOM
122
STORAGE
ROOM
120
EMPLOYEE
BREAK ROOM
130
JAN CLOSET
128
CLOSET
129
MECH ROOM
127
30 TO 36 MONTH
OLD CLASSROOM
124
LAUNDRY
ROOM
127
RESTROOM
125
EMPLOYEE
KITCHEN
126
HS-1
HS-1
P402
1
DCW AND DHW
UNDER SLAB
DCW AND DHW
UNDER SLAB
DCW AND DHW
IN FIRST
FLOOR CEILING
1 1/2"ø DCW
3/4"ø DHW
1 1/2"ø DCW
3/4"ø DHW
5 YEAR OLD
CLASSROOM
201
COAT ROOM
202
KITCHEN 2
214
HALLWAY
205 LAUNDRY/JAN
ROOM
211
36 TO 48 MONTH
OLD CLASSROOM
209
STORAGE ROOM
215
STAIR
S2
P402
2
P402
3
3/4"ø DCW
3/4"ø DHW
3/4"ø DHW
1"ø DCW
3/4"ø DCW
1/2"ø DCW
1/2"ø DHW
1/2"ø DCW
1/2"ø DHW 3/4"ø DHW
SHEET NUMBER:
KJG ARCHITECTURE, INC.
527 SAGAMORE PARKWAY WEST
WEST LAFAYETTE, INDIANA 47906
www.kjgarchitecture.com
765.497.4598
PROJECT NUMBER: CHECKED BY:
NO. DESCRIPTION DATE
This is an original design, created by KJG Architecture, Inc. The
concepts, ideas, plans and details are the sole property of KJG
Architecture, Inc. None of the aforementioned shall be used by
or disclosed to any person, firm or organization for any purpose
without the prior written permission of KJG Architecture, Inc.
PROFESSIONAL SEAL:
DISCLAIMER:
PROJECT DATE:
SHEET REVISIONS:
P201
Project Number SJS
3/11/2024PLUMBING FLOOR PLANS - WATERRENOVATE EXISTING BUILDING INTO NEW DAYCARE10455 NORTH COLLEGE AVENUECARMEL, INDIANA 46280HAMILTON COUNTYTHE FAMILY PLACE ACADAMY1/8" = 1'-0"
1 PLUMBING FIRST FLOOR PLAN - WATER
1/8" = 1'-0"
2 PLUMBING SECOND FLOOR PLAN - WATER
KEYNOTES:
NO WORK. EXISTING PLUMBING SYSTEMS TO REMAIN.
DCW AND DHW DOWN FROM THE SECOND FLOOR TO BE ROUTED UNDER
FIRST FLOOR SLAB.
DCW AND DHW ROUTED IN FIRST FLOOR CEILING.
DCW AND DHW DOWN TO BE ROUTED UNDER FIRST FLOOR SLAB, AND UP TO
SECOND FLOOR.
CONNECT NEW DCW AND DHW TO EXISTING DCW AND DHW. CONTRACTOR
TO VERIFY EXISTING PIPE SIZE AND LOCATION.
11
2
3
2
2
4
5
5
4
3
1
1
4
MS-1
3"ø SS
3"ø SS
3"ø SS
2"ø SS
JAN.
221
STAFF
RESTROOM
222
LOBBY
219
L-1
WC-1
RESTROOM
210
3"ø SS
3"ø SS
2"ø SS 2"ø SS 2"ø SS
3"ø SS
L-2 L-1
WC-1
FD-1
FCO
WC-1
WC-1
WC-1
L-2 L-1
WC-1
L-1
FCO
4"ø SS
4"ø SS
2"ø SS
EXISTING
EMPLOYEE
KITCHEN
129
30 TO 36 MONTH
OLD CLASSROOM
127
SHEET NUMBER:
KJG ARCHITECTURE, INC.
527 SAGAMORE PARKWAY WEST
WEST LAFAYETTE, INDIANA 47906
www.kjgarchitecture.com
765.497.4598
PROJECT NUMBER: CHECKED BY:
NO. DESCRIPTION DATE
This is an original design, created by KJG Architecture, Inc. The
concepts, ideas, plans and details are the sole property of KJG
Architecture, Inc. None of the aforementioned shall be used by
or disclosed to any person, firm or organization for any purpose
without the prior written permission of KJG Architecture, Inc.
PROFESSIONAL SEAL:
DISCLAIMER:
PROJECT DATE:
SHEET REVISIONS:
P401
Project Number SJS
3/11/2024PLUMBING ENLARGED PLANS - DWVRENOVATE EXISTING BUILDING INTO NEW DAYCARE10455 NORTH COLLEGE AVENUECARMEL, INDIANA 46280HAMILTON COUNTYTHE FAMILY PLACE ACADAMY1/2" = 1'-0"
2 PLUMBING RESTROOM 221 ENLARGED PLAN - DWV
1/2" = 1'-0"
3 PLUMBING RESTROOM 211 ENLARGED PLAN - DWV
KEYNOTES:
FOR CONTINUATION SEE 1/P101.
FOR CONTINUATION SEE 2/P101.
SANITARY DOWN TO FIRST FLOOR. SEE DETAIL 1/P101 FOR CONTINUATION.
SANITARY FROM THE SECOND FLOOR. ROUTE UNDER FIRST FLOOR SLAB.
1
2
3
4
1
2
3
4
1/2" = 1'-0"
1 PLUMBING RESTROOM 125 ENLARGED PLAN - DWV
2
2
L-1
WC-1
30 TO 36 MONTH
OLD CLASSROOM
127
RESTROOM
128
EXISTING
EMPLOYEE
KITCHEN
129
1"ø DCW
3/4"ø DHW
3/4"ø DCW
WC-1
MS-1
L-1
1"ø DCW
3/4"ø DHW
RESTROOM
210 1"ø DCW
WC-1
L-2 L-1
L-1L-2
WC-1 WC-1 WC-1
3/4"ø DCW
3/4"ø DCW
1"ø DCW
3/4"ø DHW
SHEET NUMBER:
KJG ARCHITECTURE, INC.
527 SAGAMORE PARKWAY WEST
WEST LAFAYETTE, INDIANA 47906
www.kjgarchitecture.com
765.497.4598
PROJECT NUMBER: CHECKED BY:
NO. DESCRIPTION DATE
This is an original design, created by KJG Architecture, Inc. The
concepts, ideas, plans and details are the sole property of KJG
Architecture, Inc. None of the aforementioned shall be used by
or disclosed to any person, firm or organization for any purpose
without the prior written permission of KJG Architecture, Inc.
PROFESSIONAL SEAL:
DISCLAIMER:
PROJECT DATE:
SHEET REVISIONS:
P402
Project Number SJS
3/11/2024PLUMBING ENLARGED PLANS - WATERRENOVATE EXISTING BUILDING INTO NEW DAYCARE10455 NORTH COLLEGE AVENUECARMEL, INDIANA 46280HAMILTON COUNTYTHE FAMILY PLACE ACADAMY1/2" = 1'-0"
1 PLUMBING RESTROOM 125 ENLARGED PLAN - WATER
1/2" = 1'-0"
2 PLUMBING RESTROOM 221 ENLARGED PLAN - WATER
1/2" = 1'-0"
3 PLUMBING RESTROOM 211 ENLARGED PLAN - WATER
KEYNOTES:
1" DCW AND 3/4" DHW DOWN TO POC ON FIRST FLOOR.
CONNECT NEW 1" DCW AND 3/4" DHW TO EXISTING DCW AND DHW NEAR
EXISTING SINK. CONTRACTOR TO VERIFY.
1" DCW AND 3/4" DHW ROUTED DOWN FROM SECOND FLOOR TO POC ON
FIRST FLOOR.
FOR CONTINUATION SEE 1/P201.
11
2
3
4
1
2
EXISTING SINK
3
4
2