Loading...
HomeMy WebLinkAboutDink House Life SafetyDie Repair 7'5""X3'Power Box 14'X5' LAB40' X 24' MAINT 41' X 42'LATHEFAB TABLEMILLDRILLCABINETSTEEL RACKS. GRINDER BOLT BINSCABINETBOLT BINS ELEVATOR48'-4"37'-2"12'-2"EXISTINGWOMENSRESTROOMEXISTINGMENSRESTROOMXXXXXX74'-718"48'-318"XXXXXXXXXXXXXXX XXXXXXLOCKERS - WITH PLASTIC LAMINATE TOP - 12" WIDE - 48 SHOWNBEVERAGEVENDINGSNACKVENDINGCOUNTER W/FREEZERBELOWBEERCARTSNACKVENDINGCOUNTER W/REFRIGERATORBELOWFUTUREFRIDGEPROSHOPSTORAGEOFFICE STORAGEPRINTERADACOUNTER DESKPOS3'-6" OF 24"STORAGE7'-0" OF 24" STORAGE 7'-6" OF 24"STORAGE 3'-0" OF 24"STORAGEIT EQUIPMENT / SECURITY / EXISTINGELECTRICAL 5'-0" OF 24"STORAGE 48'-4"37'-2"12'-2"LOCKERS - WITH PLASTIC LAMINATE TOP - 12" WIDE - 48 SHOWNBEVERAGEVENDINGSNACKVENDINGCOUNTER W/FREEZERBELOWBEERCARTSNACKVENDINGCOUNTER W/REFRIGERATORBELOWFUTUREFRIDGEPROSHOP STORAGE OFFICE STORAGE PRINTER ADA COUNTER DESK POS 3'-6" OF 24" STORAGE 7'-0" OF 24" STORAGE 7'-6" OF 24" STORAGE 3'-0" OF 24"STORAGEIT EQUIPMENT / SECURITY / EXISTING ELECTRICAL 5'-0" OF 24" STORAGEELEVATORCONFERENCEVARIES ACT201OPEN OFFICE 18'-0" ACT202IT OFFICE8'-0" ACT203MECH8'-0" ACT204WOMEN8'-0" ACT205MEN8'-0" ACT206TRAINING7'-5" ACT208STORAGE8'-0" ACT209MECH8'-0" ACT210MECH8'-0" ACT2114'-3"OFFICE7'-5" ACT212OFFICE7'-5" ACT213OFFICE7'-5" ACT214OFFICE7'-5" ACT215OFFICE7'-5" ACT216OFFICE7'-5" ACT217CORRIDOR7'-5" ACT218EXISTINGWOMENSRESTROOMEXISTINGMENSRESTROOMXXXOVERALL BUILDING CODE INFORMATIONSCOPE OF WORK1REMODEL OF EXISTING SPACE - NEW TENANT - SEE TENANT SPECIFIC INFORMATIONOCCUPANCY CLASSIFICATION2RECLASSIFIED AS A3, B - BUSINESS - SEE SHEET A002 AND A003 FOR CHAPTER 34 REVIEW INFO AND CDR3PERMITTED PER VARIANCE - PROJECT NUMBER 440809CHANGE OF OCCUPANCY CLASS?7BUILDING AREAS (SF)820,003 SF REMODELINGTOTAL PROJECT AREA9OCCUPANCY CALCULATIONSB OCCUPANCYSPACEAREASF PEROCCUPANTOCCUPANTLOADFIRST FLOOR6,723 SF1006810EGRESS WIDTHS12SPRINKLER SYSTEM (YES/NO)YES - EXISTING TO REMAINSECOND FLOOR1005,237 SFLIFE SAFETY NOTES1.PROVIDE EMERGENCY LIGHTING IN TENANT SPACE ASREQUIRED PER NEMA AND IBC. EMERGENCY BATTERYPACKS OR LIGHTS CONNECTED TO AN EMERGENCYPOWER SOURCE ARE REQUIRED IF THE SPACE CONTAINS 50PERSONS OR MORE. FIXTURES SHOWN ON PLAN ARE FORREFERENCE ONLY2.PROVIDE ALARM NOTIFICATION APPLIANCES(HORN/STROBES) EMERGENCY SPEAKERS, SMOKEDETECTORS, FORE PULLS, AND ANY OTHER REQUIREDALARM AND DETECTION SYSTEMS AS NECESSARY TO MEETALL APPLICABLE CODES (INTERNATIONAL BUILDING CODE,INTERNATIONAL FIRE CODE, NFPA).3.FIRE PROTECTION WORK IS TO BE PROVIDED BYDESIGN/BUILD SERVICES UNDER THE GENERAL CONTRACT.PROVIDE A COMPLETE WORKING SYSTEM. SODA IS NOTRESPONSIBLE FOR THE DESIGN, INSTALLATION, ORRENOVATION OF THE FIRE SPRINKLER SYSTEM.4.THE FIRE PROTECTION CONTRACTOR SHALL GENERATE ALLREQUIRED DRAWINGS, AND SHALL FILE THOSE DRAWINGS,AND RELATED DOCUMENTS, WITH THE STATE AND LOCALAUTHORITIES HAVING JURISDICTION OVER THE PROJECT.5.FIRE EXTINGUISHERS: CONTRACTOR TO ENSURE ALL NEWAND EXISTING FIRE EXTINGUISHERS ARE INSTALLEDACCORDING TO NFPA 10. COORDINATE WITHOWNER/LANDLORD ON EXTINGUISHER TYPE ANDHOUSING.MAXIMUM TRAVEL DISTANCE OF 75 FEET FROMANY POINT TO VISIBLE EXTINGUISHER.GENERAL NOTESAPPLICABLE BUILDING CODESALL WORK UNDER THIS CONTRACT SHALL COMPLY WITH THEPROVISIONS OF THE SPECIFICATIONS & DRAWINGS AND SHALLSATISFY ALL APPLICABLE CODES, ORDINANCES, A.D.A., ANDREGULATIONS OF ALL GOVERNING BODIES INVOLVED. ALLPERMITS AND LICENSES NECESSARY FOR THE PROPER EXECUTIONOF THE WORK SHALL BE SECURED AND PAID FOR BY THECONTRACTOR INVOLVED.THE FOLLOWING CODES AND REGULATIONS ARE CURRENTLYADOPTED BY THE STATE OF INDIANA AT THE TIME THE BUILDINGPERMIT IS APPLIED FOR:BUILDING CODE:INDIANA BUILDING CODE 2014 (INTERNATIONAL BUILDINGCODE 2012 WITH INDIANA AMENDMENTS)MECHANICAL CODE:INDIANA MECHANICAL CODE 2014 (INTERNATIONALMECHANICAL CODE 2012 WITH INDIANA AMENDMENTS)ELECTRICAL CODE:INDIANA ELECTRICAL CODE 2009 (NATIONAL ELECTRICALCODE 2008 WITH INDIANA AMENDMENTS)PLUMBING CODE:INDIANA PLUMBING CODE 2012 (INTERNATIONALPLUMBING CODE 2006)FIRE CODE:INDIANA FIRE CODE 2014 (INTERNATIONAL FIRE CODE2012 WITH INDIANA AMENDMENTS)ENERGY CODE:INDIANA ENERGY CONSERVATION CODE 2010 (ASHRAE90.1-2007 WITH INDIANA AMENDMENTS)FUEL GAS CODE:INDIANA FUEL GAS CODE 2014 (INTERNATIONAL FUEL GASCODE 2006 WITH INDIANA AMENDMENTS)ACCESSIBILITY CODE:INDIANA BUILDING CODE 2014, CHAPTER 11 ICC A117.1ACCESSIBLE USABLE BUILDINGS AND FACILITIES, 2009EDITION. INDIANA ADMINISTRATIVE CODE 675 IAC13-2.6-13CATEGORYSTRUCTURAL FRAMEEXTERIOR BEARING WALLSEXTERIOR NON-BEARING WALLSINTERIOR BEARING WALLSINTERIOR NON-BEARING WALLS (PARTITIONS)FLOOR / FLOOR-CEILING ASSEMBLYROOFS / ROOF-CEILING ASSEMBLYEXIT ACCESS CORRIDORSEXIT STAIR ENCLOSURESSHAFT ENCLOSURES (ELEVATOR / MECHANICAL) MIN. FIRE RESISTANCE0 HOUR - TABLE 6010 HOUR - TABLE 601 / 6020 HOUR - TABLE 601 / 6020 HOUR - TABLE 6010 HOUR - TABLE 6010 HOUR - TABLE 6010 HOUR - TABLE 6010 HOUR - TABLE 1017.1 (WITH SPRINKLER)0 HOUR - SECTION 1020.1 (LESS THAN 4 STORIES)0 HOUR - SECTION 707.4 (LESS THAN 4 STORIES)EXISTINGBUILDINGB OCC.FIRSTTOTALSECONDEXISTING EASTBUILDINGA3 OCC.6,7235,23711,96038,729--38,729NUMBER OFREQ. EXITS211II-B (FULLY SPRINKLERED)CONSTRUCTION TYPE532SPACEINCHES PEROCCUPANTINCHESREQUIREDFIRST FLOOR.1511SECOND FLOOR.15INCHESPROVIDED144 (EXCEED)872 (EXCEED)OCCUPANTLOAD6853FIRE RESISTIVE REQUIREMENTS - TYPE II-BA3 OCCUPANCYFIRST FLOOR - WEST BUILDING20,003 SF401250B OCCUPANCYFIRST FLOOR WEST.1561108 (EXCEED)401A3 OCCUPANCYFIRST FLOOR.155108 (EXCEED)31S1 OCCUPANCY481,592 SFGROSS BUILDING AREA520,003 SF FIRST FLOORREMODEL AREA (INC. IN GROSS)6ALLOWABLE AREAALLOWABLE AREA CALCULATIONS NOT REQUIRED, NO ADDITIONAL SQUAREFOOTAGE ADDED - REFER TO VARIANCE - PROJECT NUMBER 440809EXISTING FIRE EXTINGUISHERS TOREMAIN WITH NEW EXTINGUISHERSADDED TO MEET 2012 IFCWITH 2014 INDIANA AMENDMENTSA001code / egressNorthOverall Building Life Safety Second Floor Plan1/16" = 1'-0"02BA001EXITEXITEXITEXITEXIT EXITEXITEXITEXITEXITEXITNorthOverall Building Life Safety First Floor Plan1/32" = 1'-0"02AA001EXIT EXITFIRST FLOOR - EAST BUILDING38,729 SF50NorthLife Safety - THE DINK HOUSE - PICKLEBALL FACILITY1/16" = 1'-0"03A001EXITEXITEXIT NEW EXIT DOORPER TABLE 1005.1SPRINKLED BUILDINGEXIT WIDTH = 36"EXIT CAPACITY = 180 PEOPLECAPACITY REQ'D.= 135EXISTING EXIT DOORPER TABLE 1005.1SPRINKLED BUILDINGEXIT WIDTH = 36"EXIT CAPACITY = 180 PEOPLECAPACITY REQ'D.= 135EXISTING EXIT DOORPER TABLE 1005.1SPRINKLED BUILDINGEXIT WIDTH = 36"EXIT CAPACITY = 180 PEOPLECAPACITY REQ'D.= 135EXISTING FIRE DOORSEPARATING BUILDINGSEMERGENCY EGRESS FOREAST BUILDING - NOT ANEXIT FOR WEST BUILDINGEXISTINGRESTROOMACCESSIBLEFROMPICKLEBALLCOURTSCOPYRIGHT: SODA, LLC expressly reserves the common law copyright and other property rights in these plans. These plans are not to bereproduced in any form or manner, nor assigned to any third party, without first obtaining the expressed permission and consent of SODA, LLC.THE DINK HOUSE - PICKLEBALL FACILITY201 WEST CARMEL DRIVE CARMEL, IN 46032C COPYRIGHT SODA, LLC .date01.02.24PERMIT ISSUE issueCarmel, IN tj@swansonoffice.com t: 317.324.885502.19.24ADDENDUMNOSNAWSJSAMO HT CRATCTI AR11800182TEREDSIGERANAIDNIHNo.STATE OFEFELEGENDEXIT SIGNAGEFIRE EXTINGUISHERTRAVEL DISTANCE144'120'160'100'86'110'130'124'134'75'FEFEFEFEFEFEFES1 OCCUPANCYTHIS AREA IS S-1THE DINK HOUSE OPERATIONS AREASEE 03/A001775330031 9,263 SF1TENANT SPACE CALCULATIONSSPRINKLER SYSTEM (YES/NO)YES - EXISTING TO REMAINII-B (FULLY SPRINKLERED)CONSTRUCTION TYPETENANT SQUARE FEET20,003 SFBUILDING DESCRIPTIONOCCUPANCY / EGRESSCHAPTER 10 - OCCUPANT LOAD PER TABLE 1004.1.2A3 OCCUPANCY FIRST FLOORCOURT AREAS 15,831 SF CALCULATED AT 50 SF PER PERSON - 15831/50ASSEMBLY AREAS 1,293 SF NET CALCULATED WITH UNCONCENTRATEDTABLES AND CHAIRS AT 15 SF PER PERSON NET - 1,293/15STORAGE < 300 SF= 317 PERSONS= 87 PERSONS= 1 PERSON405 PERSONS TOTAL TABLE 1005.1.20 INCHES PER PERSON FOR STAIRWAYS.15 INCHES PER PERSON FOR OTHER COMPONENTSEXIT DOORS - 405 PERSONS FIRST FLOOR x .15; 61" MIN TOTAL REQUIRED = 108" PROVIDEDEGRESS PATHS - 405 PERSONS DIVIDED BETWEEN 3 EXITS = 405 / 3 = 135 PER EXIT - 135 x .15 = 20.5 REQUIRED - 44" MINEXISTING EASTBUILDINGS1 OCC.EXISTING WESTBUILDINGA3 OCC.20,0039,26320,0039,263FIRST FLOOR - EAST BUILDINGFIRST FLOOR EAST.15116144 (EXCEED)775EXIT13MAXIMUM TRAVEL DISTANCE250'-0"SWING GATES TO SWINGIN THE DIRECTION OFTRAVEL WITH 3'-0" CLEAROPENING - SPRING HINGESFOR CLOSER - NO LATCHPROVIDE MAXIMUMOCCUPANCY SIGN WITH540 PERSONS ASMAXIMUM NUMBER BASEDON EGRESS CAPACITY -COORDINATE LOCATIONOF SIGN WITH CITY OFCARMEL FIR MARSHAL88'105'NO LONGER AN EXIT -REPLACED WITH NEWDOORSINTENDED CONTROLEDENTRY FOR PICKLEBALLCOURTSFIRE SPRINKLER SYSTEM NOTE:CONTRACTOR TO COORDINATE REWORKOF EXISTING SPRINKLER SYSTEM TOACCOMMODATE NEW ROOM ANDCEILING - DESIGN BUILD CONTRACTOR TOSUBMIT DESIGN OF MODIFICATIONS TO STATEOF INDIANA AND CITY OF CARMEL AS REQUIREDPROVIDE DOUBLE SIDEDEXIT SIGN POINTEDTOWARD GATEPROVIDE SELF LUMINOUSEXIT SIGN MOUNTED TOFENCE8/19/2024