HomeMy WebLinkAboutPerformers Edge Life SafetyDie Repair 7'5""X3
'Power Box 14'X5' LAB
40' X 24'
MAINT
41' X 42'
LATHE
FAB TABLE
MILLDRILLCABINETSTEEL RACKS. GRINDERBOLT BINSCABINETBOLT BINSELEVATOR
48'-4"37'-2"12'-2"
EXISTINGWOMENS
RESTROOM
EXISTING
MENSRESTROOM
COURT 6
30'x58'
COURT 7
30'x57'
COURT 8
30'x58'
COURT 1
32'x60'
COURT 2
32'x60'
COURT 3
32'x60'
COURT 4
32'x60'
COURT 5
32'x60'DINK COURT
10'x25'
STORAGE
DINK COURT
10'x25'
ELEC.
CLOSET
106BABY
STUDIO
STUDIO 4
WAITING
ROOM
OFFICE
STUDIO
1
STUDIO
2
RECEPTION
103
105STORAGE
109
STUDIO
DANCE
OPEN
102
STORAGE
OPEN
105
OFFICE
OPEN
101
WAITING
OPEN
100
STUDIODANCE
OPEN
103
LOUNGE
STUDENT
OPEN
109 STUDIO
DANCE
OPEN
107
DANCE
BABY
OPEN
106
CORRIDOR
OPEN
104
CORRIDOR
OPEN
108
CORRIDOR
OPEN
110EX EXEX
107
101
102
WOMEN'S LOCKER / RR
8'-0" ACT
103
MEN'S LOCKER
8'-0" ACT
104
CORRIDOR
8'-0" ACT
109
MEN RR
8'-0" GYP
111
STORAGE
122
ELEVATOR
CONFERENCE RM
8'-0" ACT
102B
DISPLAY AREA
8'-0" ACT
102
106
103
105STUDIO
DANCE
OPEN
102
STORAGE
OPEN
105
OFFICE
OPEN
101
WAITING
OPEN
100
STUDIO
DANCE
OPEN
103
CORRIDOR
OPEN
104EX107
101
102
EXISTING
WOMENS
RESTROOM
EXISTING
MENS
RESTROOM
109LOUNGE
STUDENT
OPEN
109 STUDIO
DANCE
OPEN
107
DANCE
BABY
OPEN
106
CORRIDOR
OPEN
108
CORRIDOR
OPEN
110EX
EX
ELEVATOR
CONFERENCE
VARIES ACT
201
OPEN OFFICE 1
8'-0" ACT
202
IT OFFICE
8'-0" ACT
203
MECH
8'-0" ACT
204
WOMEN
8'-0" ACT
205
MEN
8'-0" ACT
206
TRAINING
7'-5" ACT
208
STORAGE
8'-0" ACT
209
MECH
8'-0" ACT
210
MECH
8'-0" ACT
2114'-3"OFFICE
7'-5" ACT
212
OFFICE
7'-5" ACT
213
OFFICE
7'-5" ACT
214
OFFICE
7'-5" ACT
215
OFFICE
7'-5" ACT
216
OFFICE
7'-5" ACT
217
CORRIDOR
7'-5" ACT
218
OVERALL BUILDING CODE INFORMATION
SCOPE OF WORK1 REMODEL OF EXISTING SPACE - NEW TENANT - SEE TENANT SPECIFIC INFORMATION
OCCUPANCY CLASSIFICATION2 RECLASSIFIED AS A3, B - BUSINESS - SEE SHEET A002 AND A003 FOR CHAPTER 34 REVIEW INFO AND CDR
3 PERMITTED PER VARIANCE - PROJECT NUMBER 440809CHANGE OF OCCUPANCY CLASS?
7 BUILDING AREAS (SF)
8 9,496 SF REMODELINGTOTAL PROJECT AREA
9 OCCUPANCY CALCULATIONS
B OCCUPANCY
SPACE AREA SF PER
OCCUPANT
OCCUPANT
LOAD
FIRST FLOOR 6,723 SF 100 68
10 EGRESS WIDTHS
12 SPRINKLER SYSTEM (YES/NO)YES - EXISTING TO REMAIN
SECOND FLOOR 1005,237 SF
LIFE SAFETY NOTES
1.PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS
REQUIRED PER NEMA AND IBC. EMERGENCY BATTERY
PACKS OR LIGHTS CONNECTED TO AN EMERGENCY
POWER SOURCE ARE REQUIRED IF THE SPACE CONTAINS 50
PERSONS OR MORE. FIXTURES SHOWN ON PLAN ARE FOR
REFERENCE ONLY
2.PROVIDE ALARM NOTIFICATION APPLIANCES
(HORN/STROBES) EMERGENCY SPEAKERS, SMOKE
DETECTORS, FORE PULLS, AND ANY OTHER REQUIRED
ALARM AND DETECTION SYSTEMS AS NECESSARY TO MEET
ALL APPLICABLE CODES (INTERNATIONAL BUILDING CODE,
INTERNATIONAL FIRE CODE, NFPA).
3.FIRE PROTECTION WORK IS TO BE PROVIDED BY
DESIGN/BUILD SERVICES UNDER THE GENERAL CONTRACT.
PROVIDE A COMPLETE WORKING SYSTEM. SODA IS NOT
RESPONSIBLE FOR THE DESIGN, INSTALLATION, OR
RENOVATION OF THE FIRE SPRINKLER SYSTEM.
4.THE FIRE PROTECTION CONTRACTOR SHALL GENERATE ALL
REQUIRED DRAWINGS, AND SHALL FILE THOSE DRAWINGS,
AND RELATED DOCUMENTS, WITH THE STATE AND LOCAL
AUTHORITIES HAVING JURISDICTION OVER THE PROJECT.
5.FIRE EXTINGUISHERS: CONTRACTOR TO ENSURE ALL NEW
AND EXISTING FIRE EXTINGUISHERS ARE INSTALLED
ACCORDING TO NFPA 10. COORDINATE WITH
OWNER/LANDLORD ON EXTINGUISHER TYPE AND
HOUSING.MAXIMUM TRAVEL DISTANCE OF 75 FEET FROM
ANY POINT TO VISIBLE EXTINGUISHER.
GENERAL NOTES
APPLICABLE BUILDING CODES
ALL WORK UNDER THIS CONTRACT SHALL COMPLY WITH THE
PROVISIONS OF THE SPECIFICATIONS & DRAWINGS AND SHALL
SATISFY ALL APPLICABLE CODES, ORDINANCES, A.D.A., AND
REGULATIONS OF ALL GOVERNING BODIES INVOLVED. ALL
PERMITS AND LICENSES NECESSARY FOR THE PROPER EXECUTION
OF THE WORK SHALL BE SECURED AND PAID FOR BY THE
CONTRACTOR INVOLVED.
THE FOLLOWING CODES AND REGULATIONS ARE CURRENTLY
ADOPTED BY THE STATE OF INDIANA AT THE TIME THE BUILDING
PERMIT IS APPLIED FOR:
BUILDING CODE:
INDIANA BUILDING CODE 2014 (INTERNATIONAL BUILDING
CODE 2012 WITH INDIANA AMENDMENTS)
MECHANICAL CODE:
INDIANA MECHANICAL CODE 2014 (INTERNATIONAL
MECHANICAL CODE 2012 WITH INDIANA AMENDMENTS)
ELECTRICAL CODE:
INDIANA ELECTRICAL CODE 2009 (NATIONAL ELECTRICAL
CODE 2008 WITH INDIANA AMENDMENTS)
PLUMBING CODE:
INDIANA PLUMBING CODE 2012 (INTERNATIONAL
PLUMBING CODE 2006)
FIRE CODE:
INDIANA FIRE CODE 2014 (INTERNATIONAL FIRE CODE
2012 WITH INDIANA AMENDMENTS)
ENERGY CODE:
INDIANA ENERGY CONSERVATION CODE 2010 (ASHRAE
90.1-2007 WITH INDIANA AMENDMENTS)
FUEL GAS CODE:
INDIANA FUEL GAS CODE 2014 (INTERNATIONAL FUEL GAS
CODE 2006 WITH INDIANA AMENDMENTS)
ACCESSIBILITY CODE:
INDIANA BUILDING CODE 2014, CHAPTER 11 ICC A117.1
ACCESSIBLE USABLE BUILDINGS AND FACILITIES, 2009
EDITION. INDIANA ADMINISTRATIVE CODE 675 IAC
13-2.6-13
CATEGORY
STRUCTURAL FRAME
EXTERIOR BEARING WALLS
EXTERIOR NON-BEARING WALLS
INTERIOR BEARING WALLS
INTERIOR NON-BEARING WALLS (PARTITIONS)
FLOOR / FLOOR-CEILING ASSEMBLY
ROOFS / ROOF-CEILING ASSEMBLY
EXIT ACCESS CORRIDORS
EXIT STAIR ENCLOSURES
SHAFT ENCLOSURES (ELEVATOR / MECHANICAL)
MIN. FIRE RESISTANCE
0 HOUR - TABLE 601
0 HOUR - TABLE 601 / 602
0 HOUR - TABLE 601 / 602
0 HOUR - TABLE 601
0 HOUR - TABLE 601
0 HOUR - TABLE 601
0 HOUR - TABLE 601
0 HOUR - TABLE 1017.1 (WITH SPRINKLER)
0 HOUR - SECTION 1020.1 (LESS THAN 4 STORIES)
0 HOUR - SECTION 707.4 (LESS THAN 4 STORIES)
EXISTING
BUILDING
B OCC.
FIRST
TOTAL
SECOND
EXISTING EAST
BUILDING
A3 OCC.
6,723
5,237
11,960
38,729
--
38,729
NUMBER OF
REQ. EXITS
2
11 II-B (FULLY SPRINKLERED)CONSTRUCTION TYPE
53 2
SPACE INCHES PER
OCCUPANT
INCHES
REQUIRED
FIRST FLOOR .15 11
SECOND FLOOR .15
INCHES
PROVIDED
144 (EXCEED)
8 72 (EXCEED)
OCCUPANT
LOAD
68
53
FIRE RESISTIVE REQUIREMENTS - TYPE II-B
A3 OCCUPANCY FIRST FLOOR - WEST BUILDING 20,003 SF 401 250
B OCCUPANCY
FIRST FLOOR WEST .15 61 108 (EXCEED)401
A3 OCCUPANCY
FIRST FLOOR .15 5 108 (EXCEED)31S1 OCCUPANCY
4 81,592 SFGROSS BUILDING AREA
5 9,496 SF FIRST FLOORREMODEL AREA (INC. IN GROSS)
6 ALLOWABLE AREA ALLOWABLE AREA CALCULATIONS NOT REQUIRED, NO ADDITIONAL SQUARE
FOOTAGE ADDED - REFER TO VARIANCE - PROJECT NUMBER 440809
EXISTING FIRE EXTINGUISHERS TO
REMAIN WITH NEW EXTINGUISHERS
ADDED TO MEET 2012 IFC
WITH 2014 INDIANA AMENDMENTS
A001
code / egress
EXIT
EXIT
EXIT
EXIT
EXITEXITEXIT
EXITEXIT EXITEXITNorth
Overall Building Life Safety First Floor Plan
1/32" = 1'-0"
01A
A001
FIRST FLOOR - EAST BUILDING 38,729 SF 50
North
Life Safety - Dance Studio
1/16" = 1'-0"
02
A001
EXIT
EXISTING EXIT DOOR
PER TABLE 1005.1
SPRINKLED BUILDING
EXIT WIDTH = 36"
EXIT CAPACITY = 180 PEOPLE
CAPACITY REQ'D.= 135
FE
LEGEND
EXIT SIGNAGE
FIRE EXTINGUISHER
TRAVEL DISTANCE
FE
S1 OCCUPANCY
THIS AREA IS S-1
THE DANCE STUDIO OPERATIONS AREA
SEE 02/A001
775 3
300 31 9,263 SF 1
EXISTING EAST
BUILDING
S1 OCC.
EXISTING WEST
BUILDING
A3 OCC.
20,003 9,263
20,003 9,263
FIRST FLOOR - EAST BUILDING
FIRST FLOOR EAST .15 116 144 (EXCEED)775
EXIT
13 MAXIMUM TRAVEL DISTANCE 250'-0"
COPYRIGHT: SODA, LLC expressly reserves the common law copyright and other property rights in these plans. These plans are not to be
reproduced in any form or manner, nor assigned to any third party, without first obtaining the expressed permission and consent of SODA, LLC.PERFORMER'S EDGE - DANCE STUDIO201 WEST CARMEL DRIVECARMEL, IN 46032C COPYRIGHT SODA, LLC .
date
01.09.24 PERMIT ISSUE
issue Carmel, IN tj@swansonoffice.com t: 317.324.885502.22.24 PERMIT REVISONNOS
N
AWSJSAMOHT
CRA TCTI
AR11800182
T ERED
SIGER
A N AIDNI
H
No.
STATE OF
E
TENANT SPACE CALCULATIONS
SPRINKLER SYSTEM (YES/NO)YES - EXISTING TO REMAIN
II-B (FULLY SPRINKLERED)CONSTRUCTION TYPE
TENANT SQUARE FEET 9,496 SF
BUILDING DESCRIPTION
OCCUPANCY / EGRESS
CHAPTER 10 - OCCUPANT LOAD PER TABLE 1004.1.2
A-3 OCCUPANCY
STUDIO(S) 6,311 SF CALCULATED AT 50 SF / PERSON
STUDENT LOUNGE 694 SF CALCULATED AT 15 SF / PERSON
WAITING AREA 581 SF CALCULATED AT 7 SF / PERSON
S1 OCCUPANCY FIRST FLOOR @350 SF WITH 300 sf / PERSON
Gross S.F. = 9,496 SF
127 PERSON(S)
46 PERSON(S)
83 PERSON(S)
+ 2 PERSON(S)
= 258 PERSONS TOTAL
TABLE 1005.1
.20 INCHES PER PERSON FOR STAIRWAYS
.15 INCHES PER PERSON FOR OTHER COMPONENTS
EXIT DOORS - 258 PERSONS x .15; 39" MIN TOTAL REQUIRED = 72" PROVIDED
EXIT
EXISTING EXIT DOOR
PER TABLE 1005.1
SPRINKLED BUILDING
EXIT WIDTH = 36"
EXIT CAPACITY = 180 PEOPLE
CAPACITY REQ'D.= 135
FE
164'
105'
90'
FE
FE
North
Overall Building Life Safety
Second Floor Plan
1/32" = 1'-0"
01B
A001
EXIT
SECONDARY
EGRESS PATH
40 OCCUPANTS
39 OCCUPANTS
28 OCCUPANTS
18 OCCUPANTS
46 OCCUPANTS
EXIT DOOR TO HAVE
PANIC EXIT DEVICE
HARDWARE -
PROVIDE EXIT LIGHT
WITH EMERGENCY
LIGHTING AT
INTERIOR AND
EXTERIOR
EXIT DOOR TO HAVE
PANIC EXIT DEVICE
HARDWARE - PROVIDE
EXIT LIGHT WITH
EMERGENCY LIGHTING
AT INTERIOR AND
EXTERIOR
EXIT DOOR TO HAVE PANIC EXIT
DEVICE HARDWARE - PROVIDE EXIT
LIGHT WITH EMERGENCY LIGHTING
AT INTERIOR AND EXTERIOR
PROVIDE
DIRECTIONAL
EXIT SIGN
EXISTING HS
EXISTING HS
EXISTING HS
EXISTING HSEXISTING HS
EXISTING HS
EXISTING HS
EXISTING HS
NEW HS
NEW HS
NEW HS
NEW HS
TWO HEADED EMERGENCY LIGHT W/ BATTERY
FIRE HORN STROBE DEVICE
PROVIDE
DIRECTIONAL
EXIT SIGN
PROVIDE
DIRECTIONAL
EXIT SIGN
8/19/2024