Loading...
HomeMy WebLinkAboutPerformers Edge Life SafetyDie Repair 7'5""X3 'Power Box 14'X5' LAB 40' X 24' MAINT 41' X 42' LATHE FAB TABLE MILLDRILLCABINETSTEEL RACKS. GRINDERBOLT BINSCABINETBOLT BINSELEVATOR 48'-4"37'-2"12'-2" EXISTINGWOMENS RESTROOM EXISTING MENSRESTROOM COURT 6 30'x58' COURT 7 30'x57' COURT 8 30'x58' COURT 1 32'x60' COURT 2 32'x60' COURT 3 32'x60' COURT 4 32'x60' COURT 5 32'x60'DINK COURT 10'x25' STORAGE DINK COURT 10'x25' ELEC. CLOSET 106BABY STUDIO STUDIO 4 WAITING ROOM OFFICE STUDIO 1 STUDIO 2 RECEPTION 103 105STORAGE 109 STUDIO DANCE OPEN 102 STORAGE OPEN 105 OFFICE OPEN 101 WAITING OPEN 100 STUDIODANCE OPEN 103 LOUNGE STUDENT OPEN 109 STUDIO DANCE OPEN 107 DANCE BABY OPEN 106 CORRIDOR OPEN 104 CORRIDOR OPEN 108 CORRIDOR OPEN 110EX EXEX 107 101 102 WOMEN'S LOCKER / RR 8'-0" ACT 103 MEN'S LOCKER 8'-0" ACT 104 CORRIDOR 8'-0" ACT 109 MEN RR 8'-0" GYP 111 STORAGE 122 ELEVATOR CONFERENCE RM 8'-0" ACT 102B DISPLAY AREA 8'-0" ACT 102 106 103 105STUDIO DANCE OPEN 102 STORAGE OPEN 105 OFFICE OPEN 101 WAITING OPEN 100 STUDIO DANCE OPEN 103 CORRIDOR OPEN 104EX107 101 102 EXISTING WOMENS RESTROOM EXISTING MENS RESTROOM 109LOUNGE STUDENT OPEN 109 STUDIO DANCE OPEN 107 DANCE BABY OPEN 106 CORRIDOR OPEN 108 CORRIDOR OPEN 110EX EX ELEVATOR CONFERENCE VARIES ACT 201 OPEN OFFICE 1 8'-0" ACT 202 IT OFFICE 8'-0" ACT 203 MECH 8'-0" ACT 204 WOMEN 8'-0" ACT 205 MEN 8'-0" ACT 206 TRAINING 7'-5" ACT 208 STORAGE 8'-0" ACT 209 MECH 8'-0" ACT 210 MECH 8'-0" ACT 2114'-3"OFFICE 7'-5" ACT 212 OFFICE 7'-5" ACT 213 OFFICE 7'-5" ACT 214 OFFICE 7'-5" ACT 215 OFFICE 7'-5" ACT 216 OFFICE 7'-5" ACT 217 CORRIDOR 7'-5" ACT 218 OVERALL BUILDING CODE INFORMATION SCOPE OF WORK1 REMODEL OF EXISTING SPACE - NEW TENANT - SEE TENANT SPECIFIC INFORMATION OCCUPANCY CLASSIFICATION2 RECLASSIFIED AS A3, B - BUSINESS - SEE SHEET A002 AND A003 FOR CHAPTER 34 REVIEW INFO AND CDR 3 PERMITTED PER VARIANCE - PROJECT NUMBER 440809CHANGE OF OCCUPANCY CLASS? 7 BUILDING AREAS (SF) 8 9,496 SF REMODELINGTOTAL PROJECT AREA 9 OCCUPANCY CALCULATIONS B OCCUPANCY SPACE AREA SF PER OCCUPANT OCCUPANT LOAD FIRST FLOOR 6,723 SF 100 68 10 EGRESS WIDTHS 12 SPRINKLER SYSTEM (YES/NO)YES - EXISTING TO REMAIN SECOND FLOOR 1005,237 SF LIFE SAFETY NOTES 1.PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER NEMA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS CONNECTED TO AN EMERGENCY POWER SOURCE ARE REQUIRED IF THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN ON PLAN ARE FOR REFERENCE ONLY 2.PROVIDE ALARM NOTIFICATION APPLIANCES (HORN/STROBES) EMERGENCY SPEAKERS, SMOKE DETECTORS, FORE PULLS, AND ANY OTHER REQUIRED ALARM AND DETECTION SYSTEMS AS NECESSARY TO MEET ALL APPLICABLE CODES (INTERNATIONAL BUILDING CODE, INTERNATIONAL FIRE CODE, NFPA). 3.FIRE PROTECTION WORK IS TO BE PROVIDED BY DESIGN/BUILD SERVICES UNDER THE GENERAL CONTRACT. PROVIDE A COMPLETE WORKING SYSTEM. SODA IS NOT RESPONSIBLE FOR THE DESIGN, INSTALLATION, OR RENOVATION OF THE FIRE SPRINKLER SYSTEM. 4.THE FIRE PROTECTION CONTRACTOR SHALL GENERATE ALL REQUIRED DRAWINGS, AND SHALL FILE THOSE DRAWINGS, AND RELATED DOCUMENTS, WITH THE STATE AND LOCAL AUTHORITIES HAVING JURISDICTION OVER THE PROJECT. 5.FIRE EXTINGUISHERS: CONTRACTOR TO ENSURE ALL NEW AND EXISTING FIRE EXTINGUISHERS ARE INSTALLED ACCORDING TO NFPA 10. COORDINATE WITH OWNER/LANDLORD ON EXTINGUISHER TYPE AND HOUSING.MAXIMUM TRAVEL DISTANCE OF 75 FEET FROM ANY POINT TO VISIBLE EXTINGUISHER. GENERAL NOTES APPLICABLE BUILDING CODES ALL WORK UNDER THIS CONTRACT SHALL COMPLY WITH THE PROVISIONS OF THE SPECIFICATIONS & DRAWINGS AND SHALL SATISFY ALL APPLICABLE CODES, ORDINANCES, A.D.A., AND REGULATIONS OF ALL GOVERNING BODIES INVOLVED. ALL PERMITS AND LICENSES NECESSARY FOR THE PROPER EXECUTION OF THE WORK SHALL BE SECURED AND PAID FOR BY THE CONTRACTOR INVOLVED. THE FOLLOWING CODES AND REGULATIONS ARE CURRENTLY ADOPTED BY THE STATE OF INDIANA AT THE TIME THE BUILDING PERMIT IS APPLIED FOR: BUILDING CODE: INDIANA BUILDING CODE 2014 (INTERNATIONAL BUILDING CODE 2012 WITH INDIANA AMENDMENTS) MECHANICAL CODE: INDIANA MECHANICAL CODE 2014 (INTERNATIONAL MECHANICAL CODE 2012 WITH INDIANA AMENDMENTS) ELECTRICAL CODE: INDIANA ELECTRICAL CODE 2009 (NATIONAL ELECTRICAL CODE 2008 WITH INDIANA AMENDMENTS) PLUMBING CODE: INDIANA PLUMBING CODE 2012 (INTERNATIONAL PLUMBING CODE 2006) FIRE CODE: INDIANA FIRE CODE 2014 (INTERNATIONAL FIRE CODE 2012 WITH INDIANA AMENDMENTS) ENERGY CODE: INDIANA ENERGY CONSERVATION CODE 2010 (ASHRAE 90.1-2007 WITH INDIANA AMENDMENTS) FUEL GAS CODE: INDIANA FUEL GAS CODE 2014 (INTERNATIONAL FUEL GAS CODE 2006 WITH INDIANA AMENDMENTS) ACCESSIBILITY CODE: INDIANA BUILDING CODE 2014, CHAPTER 11 ICC A117.1 ACCESSIBLE USABLE BUILDINGS AND FACILITIES, 2009 EDITION. INDIANA ADMINISTRATIVE CODE 675 IAC 13-2.6-13 CATEGORY STRUCTURAL FRAME EXTERIOR BEARING WALLS EXTERIOR NON-BEARING WALLS INTERIOR BEARING WALLS INTERIOR NON-BEARING WALLS (PARTITIONS) FLOOR / FLOOR-CEILING ASSEMBLY ROOFS / ROOF-CEILING ASSEMBLY EXIT ACCESS CORRIDORS EXIT STAIR ENCLOSURES SHAFT ENCLOSURES (ELEVATOR / MECHANICAL) MIN. FIRE RESISTANCE 0 HOUR - TABLE 601 0 HOUR - TABLE 601 / 602 0 HOUR - TABLE 601 / 602 0 HOUR - TABLE 601 0 HOUR - TABLE 601 0 HOUR - TABLE 601 0 HOUR - TABLE 601 0 HOUR - TABLE 1017.1 (WITH SPRINKLER) 0 HOUR - SECTION 1020.1 (LESS THAN 4 STORIES) 0 HOUR - SECTION 707.4 (LESS THAN 4 STORIES) EXISTING BUILDING B OCC. FIRST TOTAL SECOND EXISTING EAST BUILDING A3 OCC. 6,723 5,237 11,960 38,729 -- 38,729 NUMBER OF REQ. EXITS 2 11 II-B (FULLY SPRINKLERED)CONSTRUCTION TYPE 53 2 SPACE INCHES PER OCCUPANT INCHES REQUIRED FIRST FLOOR .15 11 SECOND FLOOR .15 INCHES PROVIDED 144 (EXCEED) 8 72 (EXCEED) OCCUPANT LOAD 68 53 FIRE RESISTIVE REQUIREMENTS - TYPE II-B A3 OCCUPANCY FIRST FLOOR - WEST BUILDING 20,003 SF 401 250 B OCCUPANCY FIRST FLOOR WEST .15 61 108 (EXCEED)401 A3 OCCUPANCY FIRST FLOOR .15 5 108 (EXCEED)31S1 OCCUPANCY 4 81,592 SFGROSS BUILDING AREA 5 9,496 SF FIRST FLOORREMODEL AREA (INC. IN GROSS) 6 ALLOWABLE AREA ALLOWABLE AREA CALCULATIONS NOT REQUIRED, NO ADDITIONAL SQUARE FOOTAGE ADDED - REFER TO VARIANCE - PROJECT NUMBER 440809 EXISTING FIRE EXTINGUISHERS TO REMAIN WITH NEW EXTINGUISHERS ADDED TO MEET 2012 IFC WITH 2014 INDIANA AMENDMENTS A001 code / egress EXIT EXIT EXIT EXIT EXITEXITEXIT EXITEXIT EXITEXITNorth Overall Building Life Safety First Floor Plan 1/32" = 1'-0" 01A A001 FIRST FLOOR - EAST BUILDING 38,729 SF 50 North Life Safety - Dance Studio 1/16" = 1'-0" 02 A001 EXIT EXISTING EXIT DOOR PER TABLE 1005.1 SPRINKLED BUILDING EXIT WIDTH = 36" EXIT CAPACITY = 180 PEOPLE CAPACITY REQ'D.= 135 FE LEGEND EXIT SIGNAGE FIRE EXTINGUISHER TRAVEL DISTANCE FE S1 OCCUPANCY THIS AREA IS S-1 THE DANCE STUDIO OPERATIONS AREA SEE 02/A001 775 3 300 31 9,263 SF 1 EXISTING EAST BUILDING S1 OCC. EXISTING WEST BUILDING A3 OCC. 20,003 9,263 20,003 9,263 FIRST FLOOR - EAST BUILDING FIRST FLOOR EAST .15 116 144 (EXCEED)775 EXIT 13 MAXIMUM TRAVEL DISTANCE 250'-0" COPYRIGHT: SODA, LLC expressly reserves the common law copyright and other property rights in these plans. These plans are not to be reproduced in any form or manner, nor assigned to any third party, without first obtaining the expressed permission and consent of SODA, LLC.PERFORMER'S EDGE - DANCE STUDIO201 WEST CARMEL DRIVECARMEL, IN 46032C COPYRIGHT SODA, LLC . date 01.09.24 PERMIT ISSUE issue Carmel, IN tj@swansonoffice.com t: 317.324.885502.22.24 PERMIT REVISONNOS N AWSJSAMOHT CRA TCTI AR11800182 T ERED SIGER A N AIDNI H No. STATE OF E TENANT SPACE CALCULATIONS SPRINKLER SYSTEM (YES/NO)YES - EXISTING TO REMAIN II-B (FULLY SPRINKLERED)CONSTRUCTION TYPE TENANT SQUARE FEET 9,496 SF BUILDING DESCRIPTION OCCUPANCY / EGRESS CHAPTER 10 - OCCUPANT LOAD PER TABLE 1004.1.2 A-3 OCCUPANCY STUDIO(S) 6,311 SF CALCULATED AT 50 SF / PERSON STUDENT LOUNGE 694 SF CALCULATED AT 15 SF / PERSON WAITING AREA 581 SF CALCULATED AT 7 SF / PERSON S1 OCCUPANCY FIRST FLOOR @350 SF WITH 300 sf / PERSON Gross S.F. = 9,496 SF 127 PERSON(S) 46 PERSON(S) 83 PERSON(S) + 2 PERSON(S) = 258 PERSONS TOTAL TABLE 1005.1 .20 INCHES PER PERSON FOR STAIRWAYS .15 INCHES PER PERSON FOR OTHER COMPONENTS EXIT DOORS - 258 PERSONS x .15; 39" MIN TOTAL REQUIRED = 72" PROVIDED EXIT EXISTING EXIT DOOR PER TABLE 1005.1 SPRINKLED BUILDING EXIT WIDTH = 36" EXIT CAPACITY = 180 PEOPLE CAPACITY REQ'D.= 135 FE 164' 105' 90' FE FE North Overall Building Life Safety Second Floor Plan 1/32" = 1'-0" 01B A001 EXIT SECONDARY EGRESS PATH 40 OCCUPANTS 39 OCCUPANTS 28 OCCUPANTS 18 OCCUPANTS 46 OCCUPANTS EXIT DOOR TO HAVE PANIC EXIT DEVICE HARDWARE - PROVIDE EXIT LIGHT WITH EMERGENCY LIGHTING AT INTERIOR AND EXTERIOR EXIT DOOR TO HAVE PANIC EXIT DEVICE HARDWARE - PROVIDE EXIT LIGHT WITH EMERGENCY LIGHTING AT INTERIOR AND EXTERIOR EXIT DOOR TO HAVE PANIC EXIT DEVICE HARDWARE - PROVIDE EXIT LIGHT WITH EMERGENCY LIGHTING AT INTERIOR AND EXTERIOR PROVIDE DIRECTIONAL EXIT SIGN EXISTING HS EXISTING HS EXISTING HS EXISTING HSEXISTING HS EXISTING HS EXISTING HS EXISTING HS NEW HS NEW HS NEW HS NEW HS TWO HEADED EMERGENCY LIGHT W/ BATTERY FIRE HORN STROBE DEVICE PROVIDE DIRECTIONAL EXIT SIGN PROVIDE DIRECTIONAL EXIT SIGN 8/19/2024