HomeMy WebLinkAboutPickle on Penn Sign Package (PZ-2024-00095ADLS Amend)12800 N. MERIDIAN STREET SUITE 300 CARMEL, IN 46032
TELEPHONE (317) 566-1110 FAX (317) 636-1507
TO: Aliza Shalit, Signs Permits Specialist, City of Carmel Department of Community
Services
FROM: Kevin G. Buchheit, AICP
RE: Docket PZ-2024-00095 ADLS Amend, 11575 Pennsylvania Street
DATE: August 19, 2024
For future building signage (beyond the current sign package under consideration), the
following conditions, as discussed with you and with the building owner individually, will apply:
All signs will comply with the UDO sign standards in effect at the time of sign permit or
ADLS Amend application filing.
Future signs will use raceway mounting that will be painted to match fascia.
Sign lighting will be face lit.
All signs will be made up of individual channel letters.
No sign face may be oriented to the east.
Please advise if you require additional information or documentation for this matter or for
the file.
8/21/2024
City of Carmel
Department of Community Services
Division of Planning & Zoning
LETTER of GRANT
August 21, 2024
Kevin Buchheit
Krieg DeVault LLP
12800 N Meridian St
Carmel, IN 46032
RE: Docket No. PZ -2024-00095 ADLS Amend: Pickle on Penn Reclassification & Sign Package
Dear Mr. Buchheit,
The Carmel Planning Department took the following administrative action for the approval to update the existing single
tenant building to a multi-tenant use. A Sign Package will be part of this filing. The site is located at 11575 Pennsylvania
St. It is zoned B-5 and is located within the West Homeplace Commercial Corridor overlay zone.
APPROVED: PZ-2024-00095 ADLS Amend: Pickle on Penn Reclassification & Sign Package
In order to assist the Department’s review, please attach a copy of this letter when submitting application for any permits
regarding the improvements contained within this approval.
Do not hesitate to contact me if I can be of further assistance.
Sincerely,
Aliza Shalit
Sign Permit Specialist
Department of Community Services
317.571.2417
ashalit@carmel.in.gov
cc: File
Department of Community Services
One Civic Square, Carmel, IN 46032 Phone: 317.571.2417, web: carmeldocs.com
Michael P. Hollibaugh, Director
SUE FINKAM, MAYOR
L E T T E R of G R A N T
July 23, 2024
Kevin Buchheit
Krieg DeVault LLP
12800 N. Meridian Street Ste. 300
Carmel, IN 46032
Re: BZA Docket No. PZ-2024-00109 V: 11575 Penn Sign Variance
Dear Mr. Buchheit,
At the meeting held on Monday, July 22, 2024, the Carmel Board of Zoning Appeals Hearing Officer took the
following action regarding the Development Standards Variance (V) request filed by you for the property located at
11575 Pennsylvania Street:
APPROVED: 11575 Penn Sign Variance - Development Standards Variance approval for:
PZ-2024-00109 V: Signs facing north (not toward any street frontage) is not allowed, 2 signs facing
north granted.
Please be advised that per Article 9.15 of the Unified Development Ordinance, the aforementioned Development
Standards Variance approval is valid for three (3) years. By that time, either continuous construction of the
improvements must be underway, or a written request for a one-time, six-month extension of the approval must
have been received and approval granted by this Department. The expiration date of the approval is July 22, 2027.
Please include a copy of this letter with any permit application.
If I can be of any further assistance, please do not hesitate to contact me at 317-571-2417 or aconn@carmel.in.gov.
Sincerely,
Angie Conn, AICP
Planning & Zoning Administrator
Division of Planning & Zoning
cc: Aliza Shalit – Carmel Sign Permits Specialist
File
APPROVED BY
DATE
PAGE 1
Field survey required prior
to fabrica on.
All electrical is configured
to 120V unless otherwise
specified.
The concepts herein are the property
of ISF INC. Permission to reproduce,
copy or use the design or proposal
can only be obtained through
written agreement with ISF INC. Due
to screen calibration and printing
capabilities, the colors shown are
only to be used as a close
representation or final product.
DESIGN FABRICATION
isfsigns.com
317.251.1219
6468 Rucker Road
INSTALLATION SERVICE
Indianapolis, IN 46220
DESIGNED BY: JH
REVISED LAST BY: JH
Pickle on Penn
Chris Young
Indianapolis, IN
5-28-2024
pick_5-6009_v5
Revision 1 Revision 2
Revision 3 Revision 4
Scale: 3/4” = 1’
S1 • WEST ELEVATION
S2 • NORTH ELEVATION
Fabricate and install qty (2) face-lit wall signs
Aluminum tube / angle framing
Ball” Portion (upper / lower):
3” Deep Illuminated Cabinet with 1/2” Push Thru Face
1/2” Acrylic Face - Push Thru
digitally printed / UV Treated White translucent
backed with diffuser
Colors:
Black
White
PMS 107C Yellow match
returns painted Black
Illuminated with AVL 6500 White LED’s
Mounted Flush With facade
PICKLE:
5” deep Face Lit channel letters
3/16” White acrylic (7328)Faces:
1” BlackTrimcaps:
5” deep .040” Black aluminumReturns:
AVL 6500K WhiteLEDsIllumination:
063” aluminumBacks:
Flush to BackerMounting:
Backer:
4” Deep Non-Illuminated Aluminum Can
080” Returns/ Back
080” Al. Face - Painted Black
Masked and Painted Blue: to Match PMS3590C
Flush with FacadeMounting:
ON PENN:
5” deep Face Lit channel letters
Faces: 3/16” White acrylic (7328)
1” BlackTrimcaps:
5” deep .040” Black aluminumReturns:
AVL 6500K WhiteLEDsIllumination:
063” aluminumBacks:
letters mounted to a 3” x 2” curved wirewayMounting:
flush-mounted to building fascia
Painted SW 6083Sable95
3/4”109
7/
8”
82”
28
5/8”24 7/
8”
1 0 3
4 76 3/
4”3”4”
APPROVED BY
DATE
PAGE 2
Field survey required prior
to fabrica on.
All electrical is configured
to 120V unless otherwise
specified.
The concepts herein are the property
of ISF INC. Permission to reproduce,
copy or use the design or proposal
can only be obtained through
written agreement with ISF INC. Due
to screen calibration and printing
capabilities, the colors shown are
only to be used as a close
representation or final product.
DESIGN FABRICATION
isfsigns.com
317.251.1219
6468 Rucker Road
INSTALLATION SERVICE
Indianapolis, IN 46220
DESIGNED BY: JH
REVISED LAST BY: JH
Revision 1 Revision 2
Revision 3 Revision 4
Scale: 3/4” = 1’
S1 • WEST ELEVATION
S2 • NORTH ELEVATION
Fabricate and install qty (2) face-lit wall signs
Aluminum tube / angle framing
Ball” Portion (upper / lower):
3” Deep Illuminated Cabinet with 1/2” Push Thru Face
1/2” Acrylic Face - Push Thru
digitally printed / UV Treated White translucent
backed with diffuser
Colors:
Black
White
PMS 107C Yellow match
returns painted Black
Illuminated with AVL 6500 White LED’s
Mounted Flush With facade
PICKLE:
5” deep Face Lit channel letters
3/16” White acrylic (7328)Faces:
1” BlackTrimcaps:
5” deep .040” Black aluminumReturns:
AVL 6500K WhiteLEDsIllumination:
063” aluminumBacks:
Flush to BackerMounting:
Backer:
4” Deep Non-Illuminated Aluminum Can
080” Returns/ Back
080” Al. Face - Painted Black
Masked and Painted Blue: to Match PMS3590C
Flush with FacadeMounting:
ON PENN:
5” deep Face Lit channel letters
Faces: 3/16” White acrylic (7328)
1” BlackTrimcaps:
5” deep .040” Black aluminumReturns:
AVL 6500K WhiteLEDsIllumination:
063” aluminumBacks:
letters mounted to a 3” x 2” curved wirewayMounting:
flush-mounted to building fascia
Painted SW 6083 Sable
109 7/8”
28
5/
8”
24
7/
8”1 0 3
4 3”4”
4 1/2"
4 1/2"
2’-4 5/8”2’-
4 5/
8”76
7/8"76
7/8"SIGN COMPONENTS
Pickle on Penn
Simulated Night View
APPROVED BY
DATE
PAGE 3
Field survey required prior
to fabrica on.
All electrical is configured
to 120V unless otherwise
specified.
The concepts herein are the property
of ISF INC. Permission to reproduce,
copy or use the design or proposal
can only be obtained through
written agreement with ISF INC. Due
to screen calibration and printing
capabilities, the colors shown are
only to be used as a close
representation or final product.
DESIGN FABRICATION
isfsigns.com
317.251.1219
6468 Rucker Road
INSTALLATION SERVICE
Indianapolis, IN 46220
DESIGNED BY: CA
REVISED LAST BY: JH
Scale: 1/8” = 1’
S1 • WEST ELEVATION
Revision 1 Revision 2
Revision 3 Revision 4
26’-0 1/
4”18'-
1"Pickle
on Penn Chris
Young Indianapolis, IN 5-
28-2024 pick_
APPROVED BY
DATE
PAGE 4
Field survey required prior
to fabrica on.
All electrical is configured
to 120V unless otherwise
specified.
The concepts herein are the property
of ISF INC. Permission to reproduce,
copy or use the design or proposal
can only be obtained through
written agreement with ISF INC. Due
to screen calibration and printing
capabilities, the colors shown are
only to be used as a close
representation or final product.
DESIGN FABRICATION
isfsigns.com
317.251.1219
6468 Rucker Road
INSTALLATION SERVICE
Indianapolis, IN 46220
DESIGNED BY: CA
REVISED LAST BY: JHSimulatedNightView
Scale: 1/8” = 1’
S2 • NORTH ELEVATION
Revision 1 Revision 2
Revision 3 Revision 4
26’-0 1/
4”18'-
1"Pickle
on Penn Chris
Young Indianapolis, IN 5-
28-2024 pick_
APPROVED BY
DATE
PAGE 5
Field survey required prior
to fabrica on.
All electrical is configured
to 120V unless otherwise
specified.
The concepts herein are the property
of ISF INC. Permission to reproduce,
copy or use the design or proposal
can only be obtained through
written agreement with ISF INC. Due
to screen calibration and printing
capabilities, the colors shown are
only to be used as a close
representation or final product.
DESIGN FABRICATION
isfsigns.com
317.251.1219
6468 Rucker Road
INSTALLATION SERVICE
Indianapolis, IN 46220
DESIGNED BY: CA
REVISED LAST BY: CA
Scale: 1” = 1’
S3 • WEST & NORTH ELEVATIONS
Fabricate and install qty (2) single-sided
face-lit blade signs
Aluminum tube / angle framing
080” aluminum cladding painted SW 7069 Iron Ore
routed for push-thrus
THE KITCHEN:
1/2” clear acrylic push-thrus backed with diffusers
Sign mounts to wall fascia via qty (2) 1/2” aluminum
support arms and mounting plates / thru-bolts
all painted SW 7069Iron Ore
See elevations on nextpage9”
9”6
1/
8”24”
7”14"9”3”
Revision 1 Revision 2
Revision 3 Revision
4 Pickle
on Penn
Chris Young Indianapolis,
IN 5-28-2024
pick_5-6009_
APPROVED BY
DATE
PAGE 6
Field survey required prior
to fabrica on.
All electrical is configured
to 120V unless otherwise
specified.
The concepts herein are the property
of ISF INC. Permission to reproduce,
copy or use the design or proposal
can only be obtained through
written agreement with ISF INC. Due
to screen calibration and printing
capabilities, the colors shown are
only to be used as a close
representation or final product.
DESIGN FABRICATION
isfsigns.com
317.251.1219
6468 Rucker Road
INSTALLATION SERVICE
Indianapolis, IN 46220
DESIGNED BY: CA
REVISED LAST BY: CA
Scale: 1/8” = 1’
Revision 1 Revision 2
Revision 3 Revision 4
Pickle on Penn
Chris Young
Indianapolis, IN
5-28-2024
pick_5-6009_v5
Nightview Simulation
Scale: 1/8” = 1’
8/21/2024
APPROVED BY
DATE
PAGE 7
Field survey required prior
to fabrica on.
All electrical is configured
to 120V unless otherwise
specified.
The concepts herein are the property
of ISF INC. Permission to reproduce,
copy or use the design or proposal
can only be obtained through
written agreement with ISF INC. Due
to screen calibration and printing
capabilities, the colors shown are
only to be used as a close
representation or final product.
DESIGN FABRICATION
isfsigns.com
317.251.1219
6468 Rucker Road
INSTALLATION SERVICE
Indianapolis, IN 46220
DESIGNED BY: CA
REVISED LAST BY: CA
3/32” Scale
Revision 1 Revision 2
Revision 3 Revision 4
Pickle on Penn
Chris Young
Indianapolis, IN
5-28-2024
pick_5-6009_v5
3/32” Scale
Nightview Simulation
8/21/2024
APPROVED BY
DATE
PAGE 8
Field survey required prior
to fabrica on.
All electrical is configured
to 120V unless otherwise
specified.
The concepts herein are the property
of ISF INC. Permission to reproduce,
copy or use the design or proposal
can only be obtained through
written agreement with ISF INC. Due
to screen calibration and printing
capabilities, the colors shown are
only to be used as a close
representation or final product.
DESIGN FABRICATION
isfsigns.com
317.251.1219
6468 Rucker Road
INSTALLATION SERVICE
Indianapolis, IN 46220
DESIGNED BY: CA
REVISED LAST BY: CA
S4 • EXTERIOR
Fabricate and install qty (1) cut digitally printed / UV Treated vinyl
applied to 1st surface glass
Scale: 3” = 1’
S5 • EXTERIOR
Fabricate and install qty (1) cut White vinyl
applied to 1st surface glass
Scale: 3” = 1’
Revision 1 Revision 2
Revision 3 Revision 4
M O N -F R I : X :X X -X :X X
S A T -S U N : X :X X -X :X X
21 3/4”
22”M O N -F R I : X :X X -X :X
X S A T -S U N : X :X X -X :X
X 21 3/
4”
the
Kitchen15 1/2”
Pickle on
Penn Chris
Young Indianapolis, IN
5-28-2024 pick_
5-6009_v5
10
8 8
5
10
10
129
6
10
6
4
6
13
9
C101A
JOB#: SCB.004SITEPLANDATE:
03/
10/23DRAWN BY: RCW (317) 251-1738 (FAX)
251-1923INDIANAPOLIS, INDIANA 462206555 CARROLLTON AVENUEwww.
rw-engineering.comCIVIL ENGINEERS - LAND SURVEYORS - DEVELOPMENT CONSULTANTS11575
N. PENNSYLVANIA STREETPENNWOOD OFFICE PARKCARMEL,
INDIANA 19PICKLEBALL COURTSW DAMAGE TO THE EXISTING RIGHT-OF-
WAY SHALL BE RESTORED/REPAIRED TO THE
SATISFACTION OF THE CITY AT THE COMPLETION
OF THE PROJECT.
THE CONTRACTOR IS ENCOURAGED TO INSPECT
THE RIGHT-OF-WAY WITH THE
CITY PRIOR TO THE START
OF THE CONSTRUCTION
TO DOCUMENT THE EXISTING
CONDITION OF THE RIGHT-
OF-WAY.EX. BUILDING
SIZE = 9,396 SF PR. BUILDING SIZE = 24,
722 SF SITE
AREA = 3.77 AC+/-ZONING = B-5 FRONT
SETBACK = 15 FT SIDE SETBACK = 10 FT
REAR SETBACK = 30 FT
LOT COVERAGE = 2.
23/ 3.77 = 59.
2%PARKING NORMALLY
REQUIRED:1 SPACE
PER 250 SF OF
FLOOR AREA
FLOOR AREA = 34,
118 / 250 = 136