HomeMy WebLinkAbout07030052 State Release
-,
~~f,~T..c:~~~",
&'-'"'. ~~'1:.\
_'i::'-"~f,'S"
" .., '}'"
"'\'~~i:
!'t!F;;.;~',j
-\.>Jil~:-';:~/
Would you like to reduce your turnaround time?
ELECTRONICALLY FILE YOUR PROJECT WITH STATE OF INDIANA AT
efile24~7@dhs..in.gov, Or VISIT OUR WEe SITE ATwww.in.gov/dhs/branches/plan reviewlindex.html
Project number
CONSTRUCTION DESIGN RELEASE
State Form 41191 (R9/S-9S)
Report Printed on: February 23,2007
Release date
02/23/07
324187
Construction type
I .SEE BELOW
Scope of release
*SEE BELOW
INDIANA 021
~~oo~,gQpqJ
AVailable: AI Your Local "Licence Branch
FA
FDN
MECH
ARCH ElEC
PLUM STR
Type of release
Standard
Project name
Renaissance Hotel North
Indiana Department of Homeland Security
DIVISION OF FIRE SAFETY I PLAN REVIEW
402 W. Washington St., Room E245
Indianapolis, IN 46204
SUPPORT HOOSIER SAFETY
To: Owner 1 Architect 1 Engineer
Winegardner & Hammons I nc
Jeffrey W Veigl 00003
4243 Hunt Rd
Cincinnati OH 45246
Street address
11925 N Meridian St
I City
CARMEL
County
HAMILTON
"Fax & e.mail: 5137942594, jeff.veigl@whihotels.com
I
The plans, specifications and application submitted for the above referenced project have been revievved for compliance with the applicable rules of
the Fire Prevention and Building Safety Commission. The project is released for construction subject to, but not necessarily limited to, the conditions
listed below. THIS IS NOT A BUilDING PERMIT. All required local permits and licenses must be obtained prior to beginning construction work. All
construction work must be in full compliance 'Nith all applicable State rules. Any changes in the released plans and/or specifications must be filed with
and released by this Office before any work is altered. This release may be suspended or revoked if it is determined to be issued in error, in violation
of any rules of the Commission or if it is based on incorrect or insufficient information. This release shall expire by limitation, and become null and
void, if the work authorized is not commenced within one (1) year from the above date.
CONDITIONS:
Note :(A1A & A1B): In accordance with the affidavit sworn under penalties of perjury in the application for construction design release the plans
and specifications filed in conjunction with this project shall comply 'Nith all of the applicable rules and la'NS of Fire Prevention and Building Safety
Commission. Providing false information constitutes an act of perjury, which is a Class 0 felony punishable by a prison term and a fine up to $10,000.
In accordance with Section 19 of the General Administrative Rules (675 lAC 12-6-19) a complete set of plans and specifications that conform
exactly to the design that was released by the office of the state building commissioner shall be maintained on the construction jobsite as VoIell as a
copy of the design release.
4G0603AE
3B0705C
3B0907A1
3B0505A
4G0603AP
4G0607 AN
4G0618AN
A2
3C0502H1
* * R-1 / I-B SPK (HOTEL)
A-3/ II-A SPK ( CONFERENCE BUILDING) * *
Detailed plans and specifications of the fire suppression system shall be filed with the required
application and appropriate fees in accordance with 675 lAC 12-6-3(a) and 675 lAC 13-1-8,
(N.F,PA 13)
One or more fire walls are being provided for the purposes of allowable area and minimum
construction type in accordance with Section 705.1, IBC (675 lAC 13-2,4)
The fire alarm system shall be deSigned as specified in Section 907, IFC (675 lAC 22-2,3) and
NFPA 72 (675 lAC 22-2.2-17) in accordance with Section 907, IBC (675 lAC 13-2.4).
The design and construction of a mezzanine shall be in accordance with Section 505, IBC (675 lAC
13-2.4),
This release does not include pool installations in accordance with 675 lAC 12-6-7(h)(19) and 8(b).
Plans and specifications for the kitchen exhaust hood shall be submitted in accordance with 675
lAC 12-6-7(b),
The plans and specifications of the exhaust hood suppression system shall be filed in accordance
with 675 lAC 12-6-3(a) and 7(h)(20).
An elevator installation permit shall be obtained from the Elevator Safety Division in accordance with
IESC (675 lAC 21-1-1).
For a slab-on-grade floor, the perimeter insulation shall extend downward from the top of the slab to
the top of the inverted tee of a spread footing in accordance v.ith Section 502.3,1.4, IECC (675 lAC
19-3-1),
Page 1/2
Would you like to reduce your turnaround time?
ELECTRONICALLY FILE YOUR PROJECT WITH STATE OF INDIANA AT
efile24-7@dhs..in.gov, Or VISIT OUR WEB SITE AT www.in.gov/dhs/branches/planreview/index.html
Please be advised that if an administrative review of this action is desired, a written petition for review must be filed at the above address ......;th the
Fire Prevention and Building Safety Commission identifying the matter for v.t'Iich a review is sought no later than eighteen (18) days from the above -
staled date, unless the eighteenth day falls on a Saturday, a Sunday, a legal holiday under State statute, or a day in 'Nhich the Department of Fire
and Building Services is closed during normal business hours. In the latter case, the filing deadline ......-ill be the first working day thereafter. If you
choose to petition, and the before-mentioned procedures are followed, your petition for review will be granted, and an administrative proceeding 'Ni1l !
be conducted by an administrative law judge of the Fire Prevention and Building Safety Commission. If a petition for review is not filed, this Order 'Nill i
be final, and you must comply 'Nith its requirements. i
I Filed By Code review official Code Enforcement & Plan Review Branch Director
ROBIN PHilLIPS v~d6~
Address (name,title of local official,street,city,state and ZIP code
DEPT OF COMMUNITY SERVICE State Fire Marshal V1?,O~
JIM BLANCHARD
ONE CIVIC SQUARE
I CARMEL, IN 46032
I
I Fax & e-mail: 3175712499. iblanchardtalcarmel.in."ov