Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Conduits_CityCenterVeteransWay_V2
33+0034+0035+0036+0037+0038+0039+00CITY CENTER DR.VETERANS WAYLine "K" N77°00'22"E S89°57'01"E CURVE DATA P.I. = 32+97.64 "K" Delta = 12°45'14" Lt. R = 510.00 ft T = 57.00 ft L = 113.52 ft E = 3.18 ft P.C. = 32+40.64 P.T. = 33+54.17 CURVE DATA P.I. = 35+54.58 "K" Delta = 13°02'37" Rt. R = 510.00 ft T = 58.30 ft L = 116.10 ft E = 3.32 ft P.C. = 34+96.28 P.T. = 36+12.38 P.I. = 32+97.64 "K" P.I. = 35+54.58 "K" 5+00 3+00 4+00 5+00 6+00 CITY CENTE R D R .N0°02'59"ELine "B"Line "C"P.O.T. 36+52.20 "K" = P.O.T. 5+00.00 "C" P.O.T. 36+35.96 "K" = P.O.T. 5+00.00 "B" 1+00 2+003+00 P.O.C. 36+01.95 "K" = P.O.C. 1+00.00 "D" LEGEND SHARED HANDHOLE (Lighting and Carmel IT) STREET LIGHT POLE ASSEMBLY (30' POLE WITH 8' MAST ARM) PROPOSED SERVICE POINT 4-1/c No. 4 COPPER IN PLASTIC DUCT IN TRENCH (Lighting) 4-1/c No. 4 COPPER IN PLASTIC DUCT IN TRENCH (Lighting) 2 x 2" PVC, Schedule 80 Conduit (Carmel IT) 1 2 3 1 x 4" PVC, Schedule 80 with 3 x 1-1/4" Innerducts 1 x 4" PVC, Schedule 80 OPEN CONDUIT 4 1 x 4" PVC, Schedule 80 OPEN CONDUIT (Irrigation) 5 4 4 4 4 4 1 2 1 3 1 Street Light Pole 37+48 "K" 26' Lt. Handhole 36+90 "K" 52' Rt. P-1 Cabinet/Service Point 35+81 "K" 66' Lt. Street Light Pole 4+42 "B" 40' Rt. Street Light Pole 35+23 "K" 27' Rt. Street Light Pole 35+79 "K" 49' Lt. Street Light Pole 6+14 "C" 18' Lt. Street Light Pole 4+39 "B" 35' Lt. Street Light Pole 3+90 "B" 15' Rt. Handhole 35+25 "K" 46' Lt. 4 4 Street Light Pole 5+72 "C" 29' Rt. Line "D" Relocated Street Light 34+26 "K" 46' Rt. 2 x 4" PVC, Schedule 80 OPEN CONDUIT (Carmel IT) 6 1 x 1.25" PVC, Schedule 80 OPEN CONDUIT (Carmel IT) 7 Handhole 5+79 "C" 40' Lt. Handhole 5+79 "C" 27' Rt. Relocated Street Light 35+12 "K" 40' Rt.6 6 Connect to existing electrical facilities Connect to existing Handhole Connect to existing Handhole Contractor to verify with Carmel Communications Connect to existing Handhole 4 Handhole 36+25 "K" 12' Lt. 4x4x4 COMMUNICATIONS VAULT 5 COMMUNICATIONS DUCT BANK (6 x 4" PVC, Schedule 80 OPEN CONDUIT) 1 6 2 2 1 6 4x4x4 Communications Handhole 5+93 "C" 36' Rt. Existing Carmel Communications facilities to be abandoned after new facilities installed. Contractor to coordinate with Carmel Communications 1 6 5 7 1 6 1 1 Connect to existing electrical facilities Remove existing lighting conduit and wire as necessary 7 2 1 LIGHTING DETAILS 19 1"=20' AJW/JJH RECOMMENDEDFOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: SURVEY BOOK CONTRACT DESIGNATION SHEETS of PROJECT BRIDGE FILEHORIZONTAL SCALE CITY OF CARMEL MAM RTB AJW 11/14/22 VERTICAL SCALE -21-05 - 30 DIRECTORY PATH: R:\Active\Carmel\City Center And Veterans Way RAB\Design\CAD\PlansFILENAME: LIGHTING.dwgDATE/USER: 12/1/2022 6:27 PM / Jhochstetler5$67$7(2) ',1 $,1 (5,*((76 ' 3 5 2)(66,21$/(1 *,1((5-867(1-$0 (6+2&+67 ( 7 /(51RN/A REVISIONS: 12/02/22 - Legend Item Communication Duct Bank corrected to 6 x 4" PVC conduits; Added missing '1' callout 1 1 1