Loading...
HomeMy WebLinkAbout1st on Main - As-Built Plans - 08.08.24C-100 AS-BUILT PLANS VICINITY MAP PROJECT LOCATION LOCATION MAP 1st ST NE NORTHNORTHPLAN INDEX SHEET #SUBJECT LEGAL DESCRIPTION UTILITIES PROJECT LOCATION E MAIN STN RANGELINE RD1st AVE NE1ST ON MAIN CARMEL, INDIANA DEVELOPER LAUTH GROUP, INC. 10 WEST CARMEL DRIVE, SUITE 100 CARMEL, IN 46032 PHONE: (317) 464-7517 CONTACT: KEN STROKE EMAIL: kstroke@lauth.net ENGINEER CROSSROAD ENGINEERS, PC 115 N. 17th AVE. BEECH GROVE, IN 46107 PHONE: (317) 780-1555 CONTACT: GREGORY J. ILKO EMAIL: gilko@crossroadengineers.com -#####2023-08-22CONTACT(YYYY-MM-DD)CONSULTANTTITLE: DRAWING NO.(YYYY-MM-DD)DATEREV.DESCRIPTIONPROJECT:DATETITLE:CERTIFIED BY:CONSULTANTJOB NUMBERSHEET OFTELEPHONE:LAUTH GROUP, INC.PROJECT:CONTACT:PROJECT NUMBER:STATE NUMBER:E-MAIL:FAX:1ST ON MAINAS-BUILT PLANS41 N RANGELINE RD & 10 E MAIN STCARMEL, INDIANA 460321ST ON MAINKEN STROKE317.848.6500317.848.6511kstroke@lauth.netDEVELOPMENT CONSULTANTSTRANSPORTATION &BEECH GROVE, IN 46107115 N. 17th AVE.(317) 780-1555CROSSROADENGINEERS.COMTITLE SHEETTITLE SHEET GENERAL PROJECT SUMMARY AS-BUILT CERTIFICATION STATEMENT Certified this 8th Day of August, 2024 ______________________________ George W. Charles II Professional Surveyor State of Indiana I HEREBY CERTIFY TO THE BEST OF MY KNOWLEDGE AND BELIEF, THAT THIS DRAWING HAS BEEN REVISED TO SHOW THE "AS-BUILT" LOCATIONS OF THE ON-SITE STORM SEWER, DETENTION FACILITY, AND SANITARY SEWER LATERALS. ALL OTHER INFORMATION SHOWN IS FOR DESIGN PURPOSES ONLY. STORAGE ROOMS MAINTENANCE PUMP ROOM TRASH ELECTRICALROOM IT ROOMAT&T EQUIPMENT ACCESS 1st STREET NE E MAIN STREETN RANGELINE ROAD1st AVE NESANITARY SEWER STRUCTURE TABLE STR. DATA STR. NO. SS-1 STORM SEWER STRUCTURE TABLE STR. DATA STR. NO. 1 STR. NO. 2 STR. NO. 3 STR. NO. 4 STORM SEWER STRUCTURE TABLE STR. DATA STR. NO. 5 STR. NO. 6 STR. NO. 7 STR. NO. 8 STORM SEWER STRUCTURE TABLE STR. DATA STR. NO. 9 STR. NO. 10 STR. NO. 11 STR. NO. 12 STORM SEWER CLEANOUT TABLE STR. DATA STR. NO. CO-1 STR. NO. CO-2 STR. NO. CO-3 STR. NO. CO-4 STR. NO. CO-5 STORM SEWER STRUCTURE TABLE STR. DATA STR. NO. 13 STR. NO. 14 STR. NO. 15 STR. NO. 16 C-400-#####2023-08-22CONTACT(YYYY-MM-DD)CONSULTANTTITLE: DRAWING NO.(YYYY-MM-DD)DATEREV.DESCRIPTIONPROJECT:DATETITLE:CERTIFIED BY:CONSULTANTJOB NUMBERSHEET OFTELEPHONE:LAUTH GROUP, INC.PROJECT:CONTACT:PROJECT NUMBER:STATE NUMBER:E-MAIL:FAX:1ST ON MAINAS-BUILT PLANS41 N RANGELINE RD & 10 E MAIN STCARMEL, INDIANA 460321ST ON MAINKEN STROKE317.848.6500317.848.6511kstroke@lauth.netDEVELOPMENT CONSULTANTSTRANSPORTATION &BEECH GROVE, IN 46107115 N. 17th AVE.(317) 780-1555CROSSROADENGINEERS.COMNORTHLEGEND SUTILITIES NOTES UTILITY PLANUTILITY PLAN AS-BUILT CERTIFICATION STATEMENT Certified this 8th Day of August, 2024 ______________________________ George W. Charles II Professional Surveyor State of Indiana I HEREBY CERTIFY TO THE BEST OF MY KNOWLEDGE AND BELIEF, THAT THIS DRAWING HAS BEEN REVISED TO SHOW THE "AS-BUILT" LOCATIONS OF THE ON-SITE STORM SEWER, DETENTION FACILITY, AND SANITARY SEWER LATERALS. ALL OTHER INFORMATION SHOWN IS FOR DESIGN PURPOSES ONLY. AS-BUILT LEGEND S N RANGELINE ROAD10+00STM-A HORZ. SCALE: 1"=20 VERT. SCALE: 1"=5 810 815 820 825 830 835 840 810 815 820 825 830 835 840 10+00 10+51831.97832.72833.63833.51835.07STM-B HORZ. SCALE: 1"=20 VERT. SCALE: 1"=5 810 815 820 825 830 835 840 810 815 820 825 830 835 840 15+00 15+86833.68834.25833.98833.59833.55833.29834.99834.87STM-C HORZ. SCALE: 1"=20 VERT. SCALE: 1"=5 810 815 820 825 830 835 840 810 815 820 825 830 835 840 20+00 21+00 21+50833.69833.95834.46834.85835.25835.80833.55834.04834.60835.09835.59836.09STM-D HORZ. SCALE: 1"=20 VERT. SCALE: 1"=5 810 815 820 825 830 835 840 810 815 820 825 830 835 840 25+00 25+57836.82836.54∅ ∅ ∅ ∅ ∅ STORAGEROOMS MAINTENANCE PUMP ROOM TRASH ELECTRICALROOM IT ROOMAT&TEQUIPMENTACCESS STORM SEWER STRUCTURE TABLE STR. DATA STR. NO. 1 STR. NO. 2 STR. NO. 3 STR. NO. 4 STORM SEWER STRUCTURE TABLE STR. DATA STR. NO. 5 STR. NO. 6 STR. NO. 7 STR. NO. 8 STORM SEWER STRUCTURE TABLE STR. DATA STR. NO. 9 STR. NO. 10 STR. NO. 11 STR. NO. 12 STORM SEWER CLEANOUT TABLE STR. DATA STR. NO. CO-1 STR. NO. CO-2 STR. NO. CO-3 STR. NO. CO-4 STR. NO. CO-5 STORM SEWER STRUCTURE TABLE STR. DATA STR. NO. 13 STR. NO. 14 STR. NO. 15 STR. NO. 16 E MAIN STREET20+0021+0015+00N RANGELINE ROAD E MAIN STREETE MAIN STREET25+00C-402-#####2023-08-22CONTACT(YYYY-MM-DD)CONSULTANTTITLE: DRAWING NO.(YYYY-MM-DD)DATEREV.DESCRIPTIONPROJECT:DATETITLE:CERTIFIED BY:CONSULTANTJOB NUMBERSHEET OFTELEPHONE:LAUTH GROUP, INC.PROJECT:CONTACT:PROJECT NUMBER:STATE NUMBER:E-MAIL:FAX:1ST ON MAINAS-BUILT PLANS41 N RANGELINE RD & 10 E MAIN STCARMEL, INDIANA 460321ST ON MAINKEN STROKE317.848.6500317.848.6511kstroke@lauth.netDEVELOPMENT CONSULTANTSTRANSPORTATION &BEECH GROVE, IN 46107115 N. 17th AVE.(317) 780-1555CROSSROADENGINEERS.COMKEYMAP NORTHPROPOSED LEGEND SSTORM PLAN AND PROFILESSTORM PLAN AND PROFILES MAIN ST 1st ST NE RANGELINE RD.1st AVE. NEAS-BUILT CERTIFICATION STATEMENT Certified this 8th Day of August, 2024 ______________________________ George W. Charles II Professional Surveyor State of Indiana I HEREBY CERTIFY TO THE BEST OF MY KNOWLEDGE AND BELIEF, THAT THIS DRAWING HAS BEEN REVISED TO SHOW THE "AS-BUILT" LOCATIONS OF THE ON-SITE STORM SEWER, DETENTION FACILITY, AND SANITARY SEWER LATERALS. ALL OTHER INFORMATION SHOWN IS FOR DESIGN PURPOSES ONLY. AS-BUILT LEGEND S A B C D E F G H J K STORAGE ROOMS MAINTENANCE PUMP ROOM TRASH ELECTRICAL ROOM IT ROOMAT&T EQUIPMENT ACCESS 10+0011+00STORM FROM STR. NO. 11 TO STR. NO. 12 HORZ. SCALE: 1"=10 VERT. SCALE: 1"=2 820 825 830 835 840 845 820 825 830 835 840 845 10+00 11+00 11+75833.76834.35835.06836.04837.11837.37837.55833.31833.95835.08835.73836.45836.71836.96∅ C-600-#####2023-08-22CONTACT(YYYY-MM-DD)CONSULTANTTITLE: DRAWING NO.(YYYY-MM-DD)DATEREV.DESCRIPTIONPROJECT:DATETITLE:CERTIFIED BY:CONSULTANTJOB NUMBERSHEET OFTELEPHONE:LAUTH GROUP, INC.PROJECT:CONTACT:PROJECT NUMBER:STATE NUMBER:E-MAIL:FAX:1ST ON MAINAS-BUILT PLANS41 N RANGELINE RD & 10 E MAIN STCARMEL, INDIANA 460321ST ON MAINKEN STROKE317.848.6500317.848.6511kstroke@lauth.netDEVELOPMENT CONSULTANTSTRANSPORTATION &BEECH GROVE, IN 46107115 N. 17th AVE.(317) 780-1555CROSSROADENGINEERS.COMNORTH– ‘□’ “” – – ‘□’ – ‘’ “”“” – ‘’“”“” ” – ‘’ ”“” – ‘□’ “”“” – ‘’“ ”“” BENCHMARK INFORMATION DRAINAGE PLANDRAINAGE PLAN PLAN VIEW DETENTION OUTLET STRUCTURE STR. NO. 12 SHARP CRESTED WEIR DETAIL PROPOSED LEGEND SSUMMARY ALLOWABLE RELEASE RATES: PROPOSED RELEASE RATES: REQUIRED DETENTION VOLUME: PROVIDED DETENTION VOLUME: PROPOSED ELEVATIONS: DRAINAGE AS-BUILT CERTIFICATION STATEMENT Certified this 8th Day of August, 2024 ______________________________ George W. Charles II Professional Surveyor State of Indiana I HEREBY CERTIFY TO THE BEST OF MY KNOWLEDGE AND BELIEF, THAT THIS DRAWING HAS BEEN REVISED TO SHOW THE "AS-BUILT" LOCATIONS OF THE ON-SITE STORM SEWER, DETENTION FACILITY, AND SANITARY SEWER LATERALS. ALL OTHER INFORMATION SHOWN IS FOR DESIGN PURPOSES ONLY. AS-BUILT LEGEND S