Loading...
HomeMy WebLinkAbout07040012 Receipts/Permits ~~ Th~ Schneider Corporation 8901 oti! Avenue Historic fort Harrison Indi"""po", IndiM. 46216-1037 317-626-7100 Schleider 317-828-72001 fAX This Plot Plan Prepared For: R.H. !If Indiana Lot # 200 , containing 13,189 S.F.:!:, in Clajlloume Section # 3 INSTR. , 200400080247 P.C. , 3, Slide , 533 HamDton County, Clay Twp Sec 30. llaN. ROJE 3762 Dolan Way Carmel, IN 46074 Prepared Date: 03/29/07: By: AMA Proposed Buyer(s): Un Wang & Guangtao U Community Restrictions: Side Yard = 5' Rear Yard = 20' Aggrega1e = 10' (B.H.) ZOfling = $1 (70'R/W) R,H. of Indiana 'Finished Floor Elevation Information .Pdd Grode = 918.9 per plan i'pod Grode + 0.7' = Goroge FFE (919.6 ) ;Gorage FFE + 1.5' = Residentiol FFE (921.1 ) "Residential FFE - 9,0' = Basement FFE (912.1 ) " :.Note : The garage finished floor elevation : is 2." above the curb ot the drive, per pIon. Ground Cover Calculations: '. Drive = 1,222SF:l: . Public Walk = 374 SF:!: . Private Walk =216 SF:!: I Hydroseeding = 5,619 SF:!: Sod =516 SYf, from Reor of residence. Optionol Sod Pockoge Hydroseeding =1,112 SF:!: Add!. Sod Pkg.= 500 SY:!:, to optional sod package z ;> o .;, fiLoF>E: ~ EnoInffiin& s....,mg Landscape Archllecture GIS, U8 Geolo(}' Note: This drawing is bosed on construction plans or record drawings, and is not bosed upon a field survey. The Schneider Corporation does not warrant the accuracy or sufficiency of this information. Contractors sh~uld verify existing conditions prior to any construction. Any discrepancy found on this drawing should be reported to The Schneider Corporation immediately; failing to do so results in the contractors assumption of 011 liabnity. Note: The basement elevation, depleted hereon, has been determined and based on the pod grades and/or contours taken from the construction plans for this subdivision. Unless stated, no Information about fluctuating water tables, so~ conditions, or soD t}pes has been pro'oided or stated on sold plans. this lot is located near 0 body of water. Lot or soD conditions may require that the basement floor elevation be held 2 foot above normal pool elevation. Site Investigation may be needed If W<lter Is encountered during the excavation process or if other' !<nO'.vn \'Ioter"elevatlon or so:>ii conditions ore present. Investigation and any remedial procedures is at the disaetion of the buDder to determine and talee appropriate steps of action. If any ground water Is encountered during excavation the buDder Is encouraged to conloct The Schneider Corporation to discuss possible courses of acllon. Note: Sump pump(s} to be placed by builder as needed. Detail of Ground/ Storm Water flow pattern for indtvlduallots. [OO[Q] Proposed Grades 000.0 Existing Grades __ 000,0- Contour Grade * Apprax. lateral Location - 8 - Sanitary Sewer Lines - II' - Storm Sewer Lines - 'oJ - Water Service Lines - - - - - - - Sub-Surface Drain Lines . Manhole (Sanitary or Storm) . Beehive Inlet (Slorm) IIlII ClIrt> Inlel (Storm) D End Sectioo (Stonn) A Fire Hydrant - 000 - 000 -Flow Une of swale - Bunding Une (Bl I BSl) I - - - - - - - Easement line Note; Sanitary Sewer Top of Casting Information Upstreom Monhole, TC= 917.55 Downstream Manhole, TC=919.47 per record drawing TYPICAL SWAlE SECTION .\~, g.,<:fi>t. )~ , ; Sidewalk to be placed :r:'from property line. ~1!,' from bock of curb, Ref plan. .'" Note: The contractor is to maintain a minimum distance of ten feet (W') between the sanitary sewer and water line laterals. " FLOOD HAZARD STATEMENT CERllFlCA 1l0N ,\\\\1I1111111111J1I11111 ",""-''',,- L C. 1//0'," ii! ':~ . :4/,"0. ~~~"\. ,............ /rt/~"'~ ~ <.;slo..~...G\S TEfi>>';:', ~ A~ ~ .' ~ N '0" /"'" % $}~/Q;- 0 'o.....<>~ I ( 50303 ) I ~ .. STATE OF . f[ ~ ./'. ,'~ ~<~...../II,tDIA....\~.....~ .f! ~ r,I/" \'" .....\.~"""~ % /f{} '''S''''U''o'\i'{. ,"# ~0/, l\ ., \.. ';>.\\~~ 1///1111111111111\1111\\1\\ ~l~ ----- 36 0' .. ROlL CURB I IBM lB-B7 ~ -~- ~ ~----- -1=---2~~ ~~~ .,~ - SOIl '25.0'- CONC ORIIl: . 1ML ~.G' M.H.161 TC=917.55 PER RECORD DRA~N 0' 1 Plot Pion Leqend / ~ PARK BLOCK "N" COMMON AREA ~ 0 0 0 _ _~AINAGE EASEMENT cr; _~_ ~O' DU&SE 10262/ _ __ OrDclNAJ-sQ;; PAiiAGr~1 -~ _ 916,3 --..:::----=-=--~~ 518' 40.9' Note: Bunder to ensure positive drainage away from structure(s). 000 .... -- - 56.8' I 7'XS' OfD< o o o ....- PENHURST c FRM&l/SY k! RfSlDENCE I'i "" "" o :!ii!i "l' Jf RE S{)jj BSlJNT/ CRAIIl SOD SUMP PUMP 0 i!? J;! 25.0'_ CONc. :>0011l: 25'BL 25' DU&SE it 11/R[f CAll GARAGE 8 ...: ~ S'~ 11.00' N ...: a; --- 12.0' 30,1' -.- I , 8.13~ WALl( 91 9 .. ---- --- ----- --- , , o ~ =~= o Assume~ North Scale: 1" = 30' Lot # 200 Vb07,0071022 This drawing is not intended to be represented as a retrocement or .original boundary survey, a route survey, or a Surveyor Location Report. Flood Hazard Statement The accuracy of any flood hazard data shown on this report is subject to map scale uncertainty and to any other uncertainty in location or elevation on the referenced flood insurance rate map. ALL of the within described land DOES NOT lie within that special flood hazard zone AE as said land plots by scale on flood insurance rate map #18057C 0205 F for the City of Carmel, Indiana dated February 19, 2003. SIGNA lURE : DATE: Note: Per C<1I1l\e1 lOOing ordinance 26.1.1 ; The residential district limits height to twenty-five feet (25'), however (I dwelling may be Increased In height to thirty-five feet (35') provided the side and rear yards ore Increased an additional one fool (1') for each one foot (1') the structure exceeds the first twenty-five feet (25') in height. SiGNA lURE REPRESI'NTS CON~RMA nON Of RECEIPT Of PLOT PLAN BY CUSTOt.IER.