Loading...
HomeMy WebLinkAboutC606 AQUASHIELD DETAILS2733 Kanasita Drive, Suite 111, Chattanooga, TN 37343 Phone (888) 344-9044 Fax (423) 826-2112 www.aquashieldinc.com Structure #: Drawn By: Scale: Date: Rvwed Rvw. Date U.S. Patent No. 6524473 and other Patent Pending Aqua-Swirl® XCelerator As Shown OFlores Standard Detail 2/24/2021 XC-3 CCW XC-3 STD Aqua-Swirl® Polymer Coated Steel (PCS) Stormwater Treatment System 12 in [305 mm] Manhole Frame & Cover Detail For Non-Traffic Areas Only NTS 48 in [1219 mm] Min. Gravel Backfill Concrete Wrap Compressible Expansion Joint Material to a minimum 1/2-inch [13 mm] thickness around top of riser to allow transfer of inadvertent loading from manhole cover to concrete slab. Riser Soil Cover Frame 1/2 in [13 mm] 1/2 in [13 mm] Place small amount of concrete [3,000 psi [20 MPa] (min)] to support and level manhole frame. DO NOT allow manhole frame to rest upon riser. Backfill (90% Proctor Density) 8 in [203 mm] 4 1/2 in [114 mm] Unless other traffic barriers are present, bollards shall be placed around access riser(s) in non-traffic areas to prevent inadvertent loading by maintenance vehicles. Manhole Frame & Cover Detail For Traffic Loading Areas NTS Cover Frame 48 in [1219 mm] Min. Backfill (90% Proctor Density) 3,000 psi [20 MPa] (min) Concrete #4 [13 mm] Rebar @ 6 in [152 mm] Each Way 30 in [762 mm] Riser 1/2 in [13 mm] 4 1/2 in [114 mm] 14 in [356 mm] 1/2 in [13 mm] Thick Expansion Joint Material If traffic loading (HS-25) is required or anticipated, a 4-foot [1.22 m] diameter, 14-inch [356 mm] thick reinforced concrete pad must be placed over the Stormwater Treatment System Riser to support and level the manhole frame, as shown. The top of riser pipe must be wrapped with compressible expansion joint material to a minimum 1/2-inch [13 mm] thickness to allow transfer of wheel loads from manhole cover to concrete slab. Manhole cover shall bear on concrete slab and not on riser pipe. The concrete slab shall have a minimum strength of 3,000 psi [20 MPa] and be reinforced with #4 [13 mm] reinforcing steel as shown. Minimum cover over reinforcing steel shall be 1-inch [25 mm]. Top of manhole cover and concrete slab shall be level with finish grade. Please see accompanied Aqua-Swirl® specification notes. See Site Plan for actual System orientation. Approximate dry (pick) weight: 1500 lbs [700 kg]. Backfill shall extend at least 18 inches [457 mm] outward from Swirl Concentrator and for the full height of the Swirl Concentrator (including riser) extending laterally to undisturbed soils. (See MH Detail Below) 1 1 As an alternative, 42 in [1067 mm] diameter, HS-20/25 rated precast concrete rings may be substituted. 14 in [356 mm] thickness must be maintained. XC-3 inlet/outlet pipe size ranges up to 21 in [533 mm]. XC-3 chamber height may vary up to 86 in [2184 mm], depending on inlet/outlet pipe size. Orientation may vary from a minimum of 90° to a maximum of 180°. Clockwise or counterclockwise orientation as needed. 2 3 3 2 Plan View SCALE 1:40 54 in [1372 mm] 54 in [1372 mm] n21 in [533 mm]2 Octagonal Base Plate Ø42 in [Ø107 mm] Elevation View SCALE 1:40 86 in [2184 mm] Varies Varies 5 MH Frame [127 mm] n30 in [762 mm] Band Coupler by Manufacturer. (as needed) Riser Manhole Frame and Cover by Manufacturer. (See Details) Rim elevations to match finish grade. 53 in [1346 mm] Pipe coupling by Contractor. 12 in [305 mm] long Stub-out by Manufacturer. Pipe coupling by Contractor. 12 in [305 mm] long Stub-out by Manufacturer. 4 4 el. Varies Inlet/Outlet Invert el. Varies el. Varies Grade (Rim) el. Varies n42 in [1067 mm] Projected View SCALE 1:70 Optional inlet orientations available (See note 4) n21 in [533 mm] 180° Lifting LugsLifting Lugs Backfill Bedding Undisturbed soil 18 in [457 mm] 6 in [152 mm] ADLS/DP RESUBMITTAL 9025 River Road, Suite 200 | Indianapolis, Indiana 46240 TEL 317.547.5580 | FAX 317.543.0270 www.structurepoint.com PL O T D A T E : 9/ 1 2 / 2 0 2 4 1 : 4 7 P M PL O T S C A L E : 1: 2 . 5 8 4 9 ED I T D A T E : 9/ 1 2 / 2 0 2 4 ED I T E D B Y : GM E N D I S DR A W I N G F I L E : P: \ 2 0 2 4 \ 0 0 0 2 5 \ D . D r a w i n g s \ C i v i l \ C o n s t r u c t i o n D o c u m e n t s \ 2 0 2 4 . 0 0 0 2 5 . C E . C 6 0 0 . S D . d w g Project Number CERTIFIED BY ISSUANCE INDEX DATE: PROJECT PHASE: 04/17/2024 2024.00025 INDEPENDENT SENIOR INSURANCE - 146TH STREET OFFICE 3309 E 146TH STREET CARMEL, IN 46033 INDEPENDENT SENIOR INSURANCE, INC. REVISION SCHEDULE NO.DESCRIPTION DATE A 2ND SUBMITTAL 06/07/24 B 3RD SUBMITTAL 08/09/24 C 4TH SUBMITTAL 09/12/24D INDIANA CDR 09/11/24 C606 AQUASHIELD DETAILS