HomeMy WebLinkAboutBus Stop Shelter2' - 0" 12' - 0" 2' - 0"
4'
-
0
"
1
4
'
-
0
"
2
'
-
0
"
2' - 0" 3' - 8" 7' - 0" 1' - 4" 3' - 0"
2'
-
0
"
5
'
-
4
"
3
'
-
4
"
5
'
-
4
"
2
'
-
0
"
35x 96 35x 96
7'X3' SILL @ +3'
RFT-1
P1
BUS STOP SHELTER
A409
3
A4094A4095
A409
2
6
A409
LINE OF ROOF ABOVE
B.O. ROOF
FRAMING = +9'
B.O. ROOF
FRAMING = +9'
B.O. ROOF
FRAMING = +10'
B.O. ROOF
FRAMING = +9'-4"
6
A409
6
A409
A310
1
A310
8
A310
3
A503
1
A503
2
B1
B5
B16
B8
B14
B17
B9
B19
DR
A
W
N
:
C
O
O
R
D
:
DA
T
E
:
SH
E
E
T
N
A
M
E
:
CO
M
M
I
S
S
I
O
N
:
AP
P
R
O
V
E
D
:
SHEET NO.
CE
R
T
I
F
I
C
A
T
I
O
N
9135 N. Meridian Street
Suite A1
Indianapolis, IN 46260
(T) 317.816.1144
www.coolerdesign.com
THIS DRAWING AND ITS CONTENTS ARE THE PROPERTY OF
COOLER DESIGN, INC AND SHALL NOT BE REPRODUCED,
WHOLE OR IN PART BY ANY MEANS, MECHANICAL OR
ELECTRIC, WITHOUT THE EXPRESSED WRITTEN CONSENT
OF COOLER DESIGN, INC. COPYRIGHT 2021
A409
SI
T
E
S
T
R
U
C
T
U
R
E
S
(
B
U
S
S
T
O
P
SH
E
L
T
E
R
)
NA
R
L
A
H
O
U
S
E
ej
d
ej
d
31
J
A
N
.
2
0
2
4
11
4
0
1
7
wh
c
41
3
0
W
E
S
T
1
3
1
s
t
,
C
A
R
M
E
L
,
I
N
4
6
0
3
2
3/8" = 1'-0"1 1 - FIRST FLOOR -BUS STOP SHELTER DIMENSION PLAN
3/8" = 1'-0"2 BUS STOP SHELTER FRONT
3/8" = 1'-0"3 BUS STOP SHELTER REAR
3/8" = 1'-0"4 BUS STOP SHELTER SIDE 1
3/8" = 1'-0"5 BUS STOP SHELTER SIDE 2
3/8" = 1'-0"6 BUS STOP SHELTER SECTION
WALL SECTION NOTES
B1 5/8" EXT. SHEATHING OVER 6" VERTICAL WD. STUD WALL.
B2 6" WD. STUB WALL BUILT ON TOP OF ROOF TO SUPPORT ROOF CANTILEVER FRAMING.
B3 5/8" EXT. SHEATHING OVER 6" WD. SLOPED STUD WALL.
B4 5/8" EXT. SHEATHING OVER 6" VERTICAL WD. BYPASS PARAPET STUD WALL. TOP HEIGHT
VARIES, SEE ELEVATION.
B5 1 1/2" EIFS VENEER 1 OVER LIQUID APPLIED VAPOR BARRIER.
B6 1 1/2" EIFS VENEER 2 OVER LIQUID APPLIED VAPOR BARRIER.
B7 1 1/2" EIFS VENEER 3 OVER LIQUID APPLIED VAPOR BARRIER.
B8 1 1/2" EIFS 4 SOFFIT.
B9 4" OF SPRAY FOAM INSULATION IN OUTERMOST EXTERIOR WALLS AND ROOFS.
B10 HIGH IMPACT EIFS ADD MIXTURE ON HORIZONTAL SURFACES.
B11 CUSTOM PRE-FINISHED METAL COPING.
B12 STRUCTURAL CONCRETE PIER.
B13 LARGE FORMAT, BACKLIT THIN MARBLE PANELS, HUNG FROM CONCRETE WITH METAL CLIP
SYSTEM.
B14 PREFIN. METAL CAP.
B15 3/4" PLYWOOD OVER 16" TJI ROOF JOISTS.
B16 EIFS 3 CORNICE.
B17 ROOF MEMBRANE OVER 1 1/2" RIGID INSULATION, OVER 3/4" PLYWOOD, OVER CATILEVERED
LVL ROOF FRAMING.
B18 ROOF MEMBRANE, OVER TAPERED INSULATION, 1 1/2" MIN., OVER FLAT TRUSSES, SLOPED TO
ROOF DRAIN.
B19 INSULATED CONCRETE SLAB AND FOUNDATION.
B20 INSULATED CONCRETE THICKENED SLAB.
B21 BALCONY COATING SYSTEM, OVER SLOPED CONCRETE TOPPING SLAB, OVER 3/4" PLYWOOD,
OVER 12" TJI ROOF JOISTS.
No
.
D
e
s
c
r
i
p
t
i
o
n
D
a
t
e
1
B
U
S
S
T
O
P
S
H
E
L
T
E
R
0
8
/
1
9
/
2
4
1