Loading...
HomeMy WebLinkAboutBus Stop Shelter2' - 0" 12' - 0" 2' - 0" 4' - 0 " 1 4 ' - 0 " 2 ' - 0 " 2' - 0" 3' - 8" 7' - 0" 1' - 4" 3' - 0" 2' - 0 " 5 ' - 4 " 3 ' - 4 " 5 ' - 4 " 2 ' - 0 " 35x 96 35x 96 7'X3' SILL @ +3' RFT-1 P1 BUS STOP SHELTER A409 3 A4094A4095 A409 2 6 A409 LINE OF ROOF ABOVE B.O. ROOF FRAMING = +9' B.O. ROOF FRAMING = +9' B.O. ROOF FRAMING = +10' B.O. ROOF FRAMING = +9'-4" 6 A409 6 A409 A310 1 A310 8 A310 3 A503 1 A503 2 B1 B5 B16 B8 B14 B17 B9 B19 DR A W N : C O O R D : DA T E : SH E E T N A M E : CO M M I S S I O N : AP P R O V E D : SHEET NO. CE R T I F I C A T I O N 9135 N. Meridian Street Suite A1 Indianapolis, IN 46260 (T) 317.816.1144 www.coolerdesign.com THIS DRAWING AND ITS CONTENTS ARE THE PROPERTY OF COOLER DESIGN, INC AND SHALL NOT BE REPRODUCED, WHOLE OR IN PART BY ANY MEANS, MECHANICAL OR ELECTRIC, WITHOUT THE EXPRESSED WRITTEN CONSENT OF COOLER DESIGN, INC. COPYRIGHT 2021 A409 SI T E S T R U C T U R E S ( B U S S T O P SH E L T E R ) NA R L A H O U S E ej d ej d 31 J A N . 2 0 2 4 11 4 0 1 7 wh c 41 3 0 W E S T 1 3 1 s t , C A R M E L , I N 4 6 0 3 2 3/8" = 1'-0"1 1 - FIRST FLOOR -BUS STOP SHELTER DIMENSION PLAN 3/8" = 1'-0"2 BUS STOP SHELTER FRONT 3/8" = 1'-0"3 BUS STOP SHELTER REAR 3/8" = 1'-0"4 BUS STOP SHELTER SIDE 1 3/8" = 1'-0"5 BUS STOP SHELTER SIDE 2 3/8" = 1'-0"6 BUS STOP SHELTER SECTION WALL SECTION NOTES B1 5/8" EXT. SHEATHING OVER 6" VERTICAL WD. STUD WALL. B2 6" WD. STUB WALL BUILT ON TOP OF ROOF TO SUPPORT ROOF CANTILEVER FRAMING. B3 5/8" EXT. SHEATHING OVER 6" WD. SLOPED STUD WALL. B4 5/8" EXT. SHEATHING OVER 6" VERTICAL WD. BYPASS PARAPET STUD WALL. TOP HEIGHT VARIES, SEE ELEVATION. B5 1 1/2" EIFS VENEER 1 OVER LIQUID APPLIED VAPOR BARRIER. B6 1 1/2" EIFS VENEER 2 OVER LIQUID APPLIED VAPOR BARRIER. B7 1 1/2" EIFS VENEER 3 OVER LIQUID APPLIED VAPOR BARRIER. B8 1 1/2" EIFS 4 SOFFIT. B9 4" OF SPRAY FOAM INSULATION IN OUTERMOST EXTERIOR WALLS AND ROOFS. B10 HIGH IMPACT EIFS ADD MIXTURE ON HORIZONTAL SURFACES. B11 CUSTOM PRE-FINISHED METAL COPING. B12 STRUCTURAL CONCRETE PIER. B13 LARGE FORMAT, BACKLIT THIN MARBLE PANELS, HUNG FROM CONCRETE WITH METAL CLIP SYSTEM. B14 PREFIN. METAL CAP. B15 3/4" PLYWOOD OVER 16" TJI ROOF JOISTS. B16 EIFS 3 CORNICE. B17 ROOF MEMBRANE OVER 1 1/2" RIGID INSULATION, OVER 3/4" PLYWOOD, OVER CATILEVERED LVL ROOF FRAMING. B18 ROOF MEMBRANE, OVER TAPERED INSULATION, 1 1/2" MIN., OVER FLAT TRUSSES, SLOPED TO ROOF DRAIN. B19 INSULATED CONCRETE SLAB AND FOUNDATION. B20 INSULATED CONCRETE THICKENED SLAB. B21 BALCONY COATING SYSTEM, OVER SLOPED CONCRETE TOPPING SLAB, OVER 3/4" PLYWOOD, OVER 12" TJI ROOF JOISTS. No . D e s c r i p t i o n D a t e 1 B U S S T O P S H E L T E R 0 8 / 1 9 / 2 4 1