Loading...
HomeMy WebLinkAboutSite PlanCONTRACTOR SHALL INSTALL A 2" RESTRICTOR PLATE ON TOP OF STR. #403 906.0 900.0 903.0 906.5 903.2 903.2 908.0 908.0 903.2 903.2 907.0 26' 906 . 0 9 90 8 . 5 1 90 8 . 7 5 90 3 . 8 8 902 . 5 9 90 0 . 7 2 90 0 . 9 7 > o o o 18" RCP OUTFALL Inv.: 894.64' BEEHIVE INLET Top of Crest: 897.39' N: 18" RCP Inv.: 893.79' UNKNOWN 10" CMP Inv.: 898.85' 10" CMP Inv.: 899.83' 6" PVC Inv.=907.37 8" CMP Inv.=905.88 2033 907.83 A4 W P.W.P. C.O. C.O. C.O.C.O. P.W.P. P.W.P. S S S OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OH E OH E OH E OH E OH E OH E OH E OH E OH E OH E OH E OH E OH E OH E OH E OH E OHE W W W W W W W W W W W W W W W W W W W W W 12" CMP Inv.=905.57 12" CMP Inv.=905.24 Drainage Inlet Inv.: 909.65' N: 12" RCP Inv.=907.58' 9 0 3 9 0 4 9 0 9 900 902 90 2 903 8 9 5 8 9 8 8 9 9 8 9 7 8 9 6 900 89 9 8 9 8 901 902 9 0 3 90 4 9 0 5 906 907 9 0 8 909 PS L PSL PS L PS L PS L PS L 418417 60 L.F. 15" R.C.P. @ 0.22% 415 410 86 L . F . 1 2 " H D P P @ 0 . 3 0 % 409 128 L.F. 15" HDPP @ 0.22% 408 28 6 L . F . 1 5 " H D P P @ 0 . 2 2 % 407 44 L . F . 1 5 " H D P P @ 0 . 2 3 % 406 94 L . F . 1 5 " H D P P @ 0 . 3 1 % 405 33 L.F. 18" HDPP @ 0.48% 404 28 L.F. 18" HDPP @ 0.73% 411 165 L.F. 12" HDPP @ 0.33% 403 401 22 L.F. 12" HDPP @ 0.30% 192 L.F. 12" R.C.P. @ 0.30% 402 5 9 L . F . 1 2 " R . C . P . @ 0 . 3 0 % 413 70 L.F. SLOTTED DRAIN @ 0.30% 414 70 L.F. SLOTTED DRAIN @ 0.30% 40' SETBACK LINE MOTOR COURT CONCRETE DECK POOL 5,674 SF TENNIS COURT 4,700 SF PAVERS SPA FIRE FIRE FI R E PAVERS SUNKEN FIRE PIT 638 SF FIRST FLOOR AREA = 9,321 SF F.F.E.=911.37 MLAG = 910.70 MFPG = 910.70 GARAGE F.F.E. = 911.03 PROPOSED 6' TALL WALL (BY OTHERS) PROPOSED 6' TALL WALL WITH A 2' WIDE AND 1' TALL SLOT FOR SWALE (BY OTHERS) STEPS 264 LF 6" SSD (SEE DETAIL SHEET C800) 19 7 L . F . S W A L E @ 1 . 4 2 % 10 2 L . F . S W A L E @ 1 . 7 9 % PAVERS 81 L . F . S W A L E @ 2 . 0 0 % 4 5 L . F . S W A L E @ 1 . 0 0 % 78 ' R/ W 20' 21' 8' 28 ' 32' 36' 76' 131st STREET 40 ' S E T B A C K 86 . 8 4 ' 92 . 5 4 ' 30 5 . 9 3 ' 74.82' 74.08' 119.32' 18 8 . 1 1 ' 18 2 . 9 4 ' 132.33' 92.92' 93.42' 10 YEAR ELEV.= 2 YEAR ELEV.= 100 YEAR ELEV.= DRY DETENTION BASIN #1 903.52 902.67 904.90 404A RAIN GARDEN 90 8 . 5 H. P . 905.7 910.0 910.0 910.0 910.0 910.0 910.0 910.0 910.0 910.0 910.0 910.8 910.8 910.0 910.0 909.7 910.1 910.8 911.0 911.0 911.0 909.5 909.5 910.0 910.0 910.0 910.1 910.7 910.7 910.5 910.2 909.7 910.1 910.2 910.0 910.0 910.0 910.9 910.8 910.3 910.0 911.4 911.4 911.4 911.4 911.0 911.0 911.4 911.4 911.4 911.4 911.4 911.4 911.4 909.3909.3 910.0 910.0 910.0 910.0 910.0 910.0910.0 910.0 910.0 910.0 910.1 910.1 910.1 910.0910.0 909.6 910.1910.1 909.9 910.0 909.9909.6 909.1908.9 908.8 M.E. 908.6 M.E. 908.5 907.8 906.0 906.0 906.0 906.0 910.0 906.1 906.1 908.6 909.3 906.2 907.0 908.0 909.0 908.0 909.0 909.0 910.0 910.5 910.0 910.5 910.0 910.0 908.0 909.0 H.P. 906.4906.3 908.6 910.3910.3 909.8 909.9 910.3 910.3 910.3 910.3 GATE DRIVEWAY PROPOSED FIRE HYDRANT W/ VALVE 1 5 ' D & U E 1 5 ' D & U E 1 5 ' D & U E VAR. BMPE VA R . B M P E INVERT ELEV.=900.00 TOB ELEV.=906.50 BACK TO BACK ELEV.=906.06 EX 908.7 C.O. C.O. C.O. C.O. PROPOSED 2" WATER SERVICE PROPOSED 6" WATER MAIN SAN. C.O. INV. = 907.0± 68 L. F . S W A L E @ 1 . 0 0 % 400C 400B400A 19 L.F. 21" R.C.P. @ 1.11% 89 L.F. 12" R.C.P. @ 0.30% 21 L.F. 12" R.C.P. @ 0.30% 90 6 90 7 90 8 90 9 90 9 90 8 9 0 7 909 90 4 90 5 90 6 90 7 90 8 90 9 90 9 91 0 910 910 905910906907908909 903 904 905 906 907 908 909 909 908 907 906 905 904 903 90 5 90 4 90 3 90 2 907 908 911 911 910 911 911 9 1 0 909 908 909 909 908 909 910 911 912 913 909 910 911 912 913 909 910911912 913 91 0 90 9 90 9 909 90 6 90 7 9 0 8 9 0 9 9 0 6 9 0 6 90 6 9 0 6 9 0 7 9 0 8 90 5 90 4 9 0 5 9 0 4 9 0 3 90 8 90 9 90 9 9 0 8 90 8 90 7 9 0 7 906 90 7 911 8 9 8 8 9 7 8 9 6 8 9 9 89 8 M PROPOSED WATER METER RFT-1 P1 BUS STOP SHELTER 94 ' 88' 21 2 ' STORMWATER MANAGEMENT AREA SIGN (TYP.) 910.0 910.1 PROPOSED FIRE HYDRANT W/ VALVE CO 320 910.10 M PROPOSED WATER METER 106842 RPL BMB CA R M E L , C L A Y T O W N S H I P HA M I L T O N C O U N T Y , I N D I A N A 09 / 1 4 / 2 3 Fi l e N a m e : S: \ 1 0 6 8 4 2 \ D W G \ C 2 0 0 S i t e P l a n . d w g - C2 0 0 Mo d i f i e d / B y : Au g u s t 2 2 , 2 0 2 4 9 : 1 3 : 5 5 A M / bb r o w n Pl o t t e d / B y : Oc t o b e r 1 , 2 0 2 4 1 2 : 4 9 : 3 2 P M / Br i a n B r o w n NA R L A R E S I D E N C E 41 3 0 W 1 3 1 S T S T R E E T , C A R M E L , I N 4 6 0 7 4 11 / 1 4 / 2 3 RE V I S E D P E R C I T Y A N D C L I E N T C O M M E N T S RP L 12 / 0 1 / 2 3 RE V I S E D P E R C I T Y C O M M E N T S RP L 03 / 2 1 / 2 4 RE V I S E D P E R R E V I E W I N G A G E N C Y C O M M E N T S RP L DA T E MA R K RE V I S I O N S BY CE R T I F I E D : S & A JOB NO. SHEET NO. DRAWN BY:CHECKED BY: S T O E P P E L W E R T H A L W A Y S O N 79 6 5 E a s t 1 0 6 t h S t r e e t , F i s h e r s , I N 4 6 0 3 8 - 2 5 0 5 ph o n e : 3 1 7 . 8 4 9 . 5 9 3 5 f a x : 3 1 7 . 8 4 9 . 5 9 4 2 TH I S D R A W I N G I S N O T I N T E N D E D T O B E RE P R E S E N T E D A S A R E T R A C E M E N T O R OR I G I N A L B O U N D A R Y S U R V E Y , A R O U T E SU R V E Y O R A S U R V E Y O R L O C A T I O N RE P O R T . SI T E D E V E L O P M E N T P L A N C200 GRAPHIC SCALE ( IN FEET ) 1" = 40 FT LEGEND EXISTING SANITARY SEWER EXISTING STORM SEWER EXISTING WATER LINE EXISTING CONTOUR PROPOSED SANITARY SEWER PROPOSED STORM SEWER PROPOSED CONTOUR PROPOSED WATER LINE PROPOSED SWALE PROPOSED GRADE ELEVATION PROPOSED 5' SIDEWALK (BY HOME BUILDER) (DEVELOPER SHALL INSTALL SIDEWALKS ALONG ALL COMMON AREAS) PROPOSED CURB w/ 6" UNDERDRAIN PROPOSED 6" SUB-SURFACE DRAIN B.L.BUILDING SETBACK LINE M.E.MATCH EXISTING H.P.HIGH POINT L.P.LOW POINT GRD. CHG.GRADE CHANGE DENOTES SNOW FENCE TO BE INSTALLED FOR TREE PROTECTION RISER BENCHMARK DATA TBM #1 CENTER AT BACK OF WALK OF CURB INLET ON SOUTH SIDE OF LETTS LANE. ELEV= 901.83' (NAVD 88) TBM #2 NORTH BONNET BOLT ON FIRE HYDRANT LOCATED WEST OF HOUSE #13255 LETTS LANE. ELEV= 901.83' (NAVD 88) ORIGINATING BENCHMARK O.P.U.S. BENCHMARK ELEVATIONS FOR THIS PROJECT WERE DERIVED USING THE NATIONAL GEODETIC SURVEY ONLINE POSITIONING USER SERVICE (O.P.U.S.) AND ARE REFERENCED TO THE NAVD '88 DATUM CONSTRUCTION LIMITS PERMEABLE PAVERS NON PERMEABLE PAVERS CONCRETE RAIN GARDEN 1.THIS SURVEY REFLECTS ABOVE GROUND INDICATIONS OF UTILITIES AND INFORMATION AVAILABLE FROM UTILITY COMPANIES. THE SURVEYOR MAKES NO GUARANTEE THAT THE UNDERGROUND UTILITIES SHOWN COMPRISE ALL SUCH UTILITIES IN THE AREA, EITHER IN SERVICE OR ABANDONED. THE SURVEYOR FURTHER DOES NOT WARRANT THAT THE UNDERGROUND UTILITIES SHOWN ARE IN THE EXACT LOCATION INDICATED, ALTHOUGH HE DOES CERTIFY THAT THEY ARE LOCATED AS ACCURATELY AS POSSIBLE FROM THE INFORMATION AVAILABLE. THE SURVEYOR HAS NOT PHYSICALLY LOCATED THE UNDERGROUND UTILITIES. 2.CONTRACTOR SHALL VERIFY DEPTHS OF ALL EXISTING ONSITE UTILITIES PRIOR TO CONSTRUCTION TO CONFIRM THERE ARE NOT ANY CONFLICTS WITH OTHER UTILITIES, STORM SEWERS OR STREETS. CONFLICTS AFTER CONSTRUCTION BEGINS ARE SOLELY THE CONTRACTOR'S RESPONSIBILITY. 3.STORM WATER CONTROLS SHOWN ON THE INITIAL SWPPP (C300) SHOULD BE INSTALLED AS SOON AS PRACTICAL. 4.IF IT WILL BE NECESSARY TO RELOCATE EXISTING UTILITIES, THE EXPENSE OF SUCH RELOCATION SHALL BE THE RESPONSIBILITY OF THE DEVELOPER. ALL UTILITY POLES SHALL BE LOCATED WITHIN ONE FOOT OF THE PROPOSED RIGHT-OF-WAY. 5.ALL PADS SHOULD BE TESTED TO ASSURE A COMPACTION OF AT LEAST 95 PERCENT OF THE MAXIMUM DRY DENSITY USING THE STANDARD PROCTOR TEST METHOD. 6.ANY PRIVATE TILES LOCATED ON THIS SITE WILL NEED TO BE LOCATED; BREATHERS SET AT THE DOWNSTREAM PROPERTY LINE AND CRUSHED OR REMOVED ACROSS THIS SITE. IF ANY OF THESE TILES EXTEND BEYOND THE LIMITS OF THIS PROJECT, THEY WILL NEED TO BE PROVIDED A POSITIVE OUTLET AND ALLOWED TO CONTINUE TO FUNCTION, AS IT IS ILLEGAL TO BLOCK OFF A PRIVATE "MUTUAL" TILE. 7.CONTRACTOR SHALL CONTACT THE DEPARTMENT OF ENGINEERING TO SCHEDULE A PRE-CONSTRUCTION MEETING TO REVIEW THE DEPARTMENT'S CONSTRUCTION REQUIREMENTS, STAFF NOTIFICATION REQUIREMENTS, REQUIRED INSPECTIONS FOR CERTAIN STAGES OF WORK TO REVIEW THE AUTHORITY OF THE DEPARTMENT AS IT RELATES TO WORK WITHIN THE EXISTING AND PROPOSED CITY R/W. 8.EXISTING PAVEMENT TO BE SAW CUT TO A CLEAN EDGE ADJACENT TO ANY WIDENING, AUXILIARY LANES, ETC. 9.NO EARTH DISTURBING ACTIVITY MAY TAKE PLACE WITHOUT AN APPROVED STORM WATER MANAGEMENT PERMIT. 10.DAMAGE TO THE EXISTING RIGHT-OF-WAY SHALL BE RESTORED/REPAIRED TO THE SATISFACTION OF THE CITY AT THE COMPLETION OF THE PROJECT. THE CONTRACTOR IS ENCOURAGED TO INSPECT THE RIGHT-OF-WAY WITH THE CITY PRIOR TO THE START OF CONSTRUCTION TO DOCUMENT THE EXISTING CONDITION OF THE RIGHT-OF-WAY. 11.UTILITY RELOCATIONS REQUIRED BY THE PROJECT SHALL BE THE RESPONSIBILITY OF THE DEVELOPER. UTILITY LINE RELOCATIONS REQUIRED FOR ROAD PROJECTS THAT RESULT IN A CONFLICT WITH PROPOSED DEVELOPMENT SHALL BE THE RESPONSIBILITY OF THE DEVELOPER TO RESOLVE WITH THE UTILITY. EXISTING POLE LINES REQUIRED TO BE RELOCATED SHALL BE RELOCATED TO WITHIN ONE FOOT OF PROPOSED RIGHT-OF-WAY LINE. 12.ALL PAVING WITHIN THE EXISTING AND PROPOSED CITY RIGHT-OF-WAY SHALL CONFORM TO THE REQUIREMENTS OF THE DEPARTMENT OF ENGINEERING. THE CONTRACTOR SHALL CONTACT THE DEPARTMENT OF ENGINEERING TO SCHEDULE A PRE-CONSTRUCTION MEETING TO REVIEW THE DEPARTMENT'S CONSTRUCTION REQUIREMENTS, STAFF NOTIFICATION REQUIREMENTS, REQUIRED INSPECTIONS FOR CERTAIN STAGES OF THE WORK AND THE REVIEW THE AUTHORITY OF THE DEPARTMENT AS IT RELATES TO WORK WITHIN THE EXISTING AND PROPOSED RIGHT-OF-WAY. 13.ANY DISTURBANCE TO EXISTING BMP GRADING AND/OR VEGETATION SHALL BE RESTORED PER DETAILS AND SPECIFICATIONS SHOWN ON V3 DESIGN DEVELOPMENT DOCUMENTS. 14.ALL STORM SEWERS ARE PRIVATE 15.MINIMUM FLOOD PROTECTION GRADE OF ALL STRUCTURES FRONTING A POND OR OPEN DITCH SHALL BE NO LESS THAN 1 FOOT ABOVE ANY ADJACENT 100-YEAR LOCAL FLOOD ELEVATIONS OR 2 FEET ABOVE ANY ADJACENT 100-YEAR REGIONAL FLOOD ELEVATIONS, WHICHEVER IS GREATER, FOR ALL WINDOWS, DOORS, PIPE ENTRANCES, WINDOW WELLS, AND ANY OTHER STRUCTURE MEMBER WHERE FLOODWATERS CAN ENTER A BUILDING. 16.THERE ARE NO 100 YEAR FLOODPLAINS, FLOODWAY FRINGES, OR FLOODWAYS ON THIS SITE. NOTES DRAINAGE SUMMARY NORTHWEST OUTLET Site Acreage=+/-4.75 ac. Offsite/Upstream Acreage=+/-1.36 ac. Volume Required: 49,012 cu.ft. Volume Provided: 95,954.5 cu.ft. Allowable Release Rate: 10yr = 0.39 c.f.s. 100yr = 1.17 c.f.s. Post Developed Release Rate: 10 yr = 0.19 c.f.s. 100 yr = 0.23 c.f.s. Is the primary water quality treatment for the development as planned in the Master Plan - If NO, provide the following information per BMP (Only for BMP's with vegetative swale req.): *Length of vegetated swale treatment (from disharge point to outlet pipe) - N/A *Minimum length of vegetated swale treatment as required by the Master Plan - N/A Is the primary water quantity treatment for the development as planned in the Master Plan - *If YES, provide the following information: Total Master Plan contributing watershed = Total Watershed Currently Built (or Approved) contributing to this system = 0 Ac. Total watershed from Total watershed available in the system post-project = Is the entire BMP treatment train to an outlet point being constructed with this section - YES If NO, provide the following information: Detention Basins BMP's Constructed with this section. (See BMP pond data table-this sheet) - N/A HORIZONTAL DATUM HORIZONTAL DATUM SHALL BE BASED ON INDIANA STATE PLANE COORDINATES, NAD83. 11 / 1 4 / 2 3 RE V I S E D P E R C I T Y A N D C L I E N T C O M M E N T S RP L 12 / 0 1 / 2 3 RE V I S E D P E R C I T Y C O M M E N T S RP L 03 / 2 1 / 2 4 RE V I S E D P E R R E V I E W I N G A G E N C Y C O M M E N T S RP L STRUCTURAL NOTES MAXIMUM BUILDING HEIGHT 35 FEET FOR A PRINCIPLE BUILDING, 18 FEET FOR AN ACCESSORY BUILDING SITE TAKE-OFFS TOTAL LOT = PROPOSED POOL = GUARD HOUSE = TENNIS COURT = CONCRETE = PAVERS = BUILDING FIRST FLOOR = GARAGE = PORCH/PATIO = 274,602 SF 5,674 SF 201 SF 4,700 SF 29,676 SF 23,543 SF 9,321 SF 1,932 SF 1,101 SF EARTHWORK NOTES 1. EXCAVATION A. EXCAVATED MATERIAL THAT IS SUITABLE MAY BE USED FOR FILLS. ALL UNSUITABLE MATERIAL AND ALL SURPLUS EXCAVATED MATERIAL NOT REQUIRED SHALL BE REMOVED FROM THE SITE. B. PROVIDE AND PLACE ANY ADDITIONAL FILL MATERIAL FROM OFFSITE AS MAY BE NECESSARY TO PRODUCE THE GRADES REQUIRED ON PLANS. FILL OBTAINED FROM OFFSITE SHALL BE OF QUALITY AS SPECIFIED FOR FILLS HEREIN AND THE SOURCE APPROVED BY THE DEVELOPER. IT WILL BE THE RESPONSIBILITY OF THE CONTRACTOR FOR ANY COSTS FOR FILL NEEDED. 2. REMOVAL OF TREES A. ALL TREES AND STUMPS SHALL BE REMOVED FROM AREAS TO BE OCCUPIED BY A ROAD SURFACE OR STRUCTURE AREA. TREES AND STUMPS SHALL NOT BE BURIED ON SITE. 3. PROTECTION OF TREES A. THE CONTRACTOR SHALL, AT THE DIRECTION OF THE DEVELOPER, ENDEAVOR TO SAVE AND PROTECT TREES OF VALUE AND WORTH WHICH DO NOT IMPAIR CONSTRUCTION OF IMPROVEMENTS AS DESIGNED. B. IN THE EVENT CUT OR FILL EXCEEDS 0.5 FEET OVER THE ROOT AREA, THE DEVELOPER SHALL BE CONSULTED WITH RESPECT TO PROTECTIVE MEASURE TO BE TAKEN, IF ANY, TO PRESERVE SUCH TREES. 4. REMOVAL OF TOPSOIL A. ALL TOPSOIL SHALL BE REMOVED FROM ALL AREAS BENEATH FUTURE PAVEMENTS OR BUILDING. TOPSOIL REMOVAL SHALL BE TO A MINIMUM DEPTH OF 6 INCHES OR TO THE DEPTH INDICATED IN THE GEOTECHMICAL REPORT PROVIDED BY THE DEVELOPER TO BE EXCAVATED OR FILLED. TOPSOIL SHOULD BE STORED AT A LOCATION WHERE IT WILL NOT INTERFERE WITH CONSTRUCTION OPERATIONS. THE TOPSOIL SHALL BE FREE OF DEBRIS AND STONES. 5. UTILITIES A. RULES AND REGULATION GOVERNING THE RESPECTIVE UTILITY SHALL BE OBSERVED IN EXECUTING ALL WORK UNDER THIS SECTION. B. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO DETERMINE THE LOCATION OF EXISTING UNDERGROUND UTILITIES 2 WORKING DAYS PRIOR TO COMMENCING WORK. FOR UTILITY LOCATIONS TO BE MARKED CALL TOLL FREE 811. 6. SITE GRADING A. THE CONTRACTOR SHALL DO ALL CUTTING, FILLING, COMPACTING OF FILLS AND ROUGH GRADING REQUIRED TO BRING ENTIRE PROJECT AREA TO SUBGRADE AS SHOWN ON THE DRAWING. B. THE TOLERANCE FOR PAVED AREAS SHALL NOT EXCEED 0.05 FEET ABOVE ESTABLISHED SUBGRADE. ALL OTHER AREAS SHALL NOT EXCEED 0.05 FEET PLUS OR MINUS THE ESTABLISHED GRADE. PROVIDE ROUNDINGS AT TOP AND BOTTOM OF BANKS AND OTHER BREAKS IN GRADE. C. THE ENGINEER SHALL BE NOTIFIED WHEN THE CONTRACTOR HAS REACHED THE TOLERANCE AS STATED ABOVE, SO THAT FIELD MEASUREMENTS AND SPOT ELEVATIONS CAN BE VERIFIED BY THE ENGINEER. THE CONTRACTOR SHALL NOT REMOVE EQUIPMENT FROM THE SITE UNTIL THE ENGINEER HAS VERIFIED THAT THE JOB MEETS THE ABOVE TOLERANCE. DRY DETENTION POND & RAIN GARDEN DETAIL A-A 40'± 5 1 VARIES 25' ± 5 1 PROPOSED GRADE EXISTING GRADE 1% MIN. 100 YR = 904.90 10 YR = 903.52 2 YR = 902.67 GENERAL NOTES 1.CONTRACTOR SHALL VERIFY DEPTHS OF ALL EXISTING ONSITE UTILITIES PRIOR TO CONSTRUCTION TO CONFIRM THERE IS NOT ANY CONFLICTS WITH OTHER UTILITIES, STORM SEWERS OR STREETS. CONFLICTS AFTER CONSTRUCTION BEGINS ARE SOLELY THE CONTRACTOR'S RESPONSIBILITY. 2.THE STORM SEWER SYSTEM SHALL BE CONSTRUCTED PER DESIGN SPECIFIED AND AS APPROVED BY THE CITY OF CARMEL ON THE FINAL APPROVED CONSTRUCTION PLANS. DEVIATIONS FROM THE APPROVED DESIGN SHALL ONLY BE PERMITTED DUE TO SPECIAL CIRCUMSTANCES OR DIFFICULTY DURING CONSTRUCTION AND WILL REQUIRE PRIOR FIELD APPROVAL FROM A DESIGNATED REPRESENTATIVE OF THE CITY OF CARMEL IN ADDITION TO SUPPLEMENTAL APPROVAL BY THE DESIGN ENGINEER. AN EXPLANATION OF ANY SUCH DEVIATION SHALL BE INCLUDED AS A REQUIREMENT ON AS-BUILT/RECORD DRAWINGS SUBMITTED FOR RELEASE OF PERFORMANCE GUARANTEES. APPROVED DESIGN SLOPES IDENTIFIED AS GENERATING VELOCITIES OF 2.5 FPS OR LESS OR 10 FPS OR GREATER (AT FULL FLOW CAPACITY) SHALL REQUIRE AS-BUILT CERTIFICATION AT THE TIME OF CONSTRUCTION, PRIOR TO BACKFILLING THE PIPE. THE CONTRACTOR IS INSTRUCTED TO AS-BUILT EACH SECTION OF STORM PIPE AS IT IS BEING INSTALLED TO ENSURE COMPLIANCE WITH THE DESIGN PLANS AND AS APPROVED BY THE CITY OF CARMEL. RAIN GARDEN PLANTING LIST 1.GREAT BLUE LOBELIA 2.GREEN-HEADED CONEFLOWER 3.BLUE VERVAIN 4.BIG BLUESTERN 5.FOWL MANNA GRASS A A B B 60' ± RAIN GARDEN DETAIL B-B 3 1 3 1 95' ± INV. = 900.00 TOB ELEV. = 906.50 TOE ELEV. = 903.00 TOP OF WIER = 906.50 3 1 3 1 BOTTOM ELEV. = 903.20 BOTTOM ELEV. = 903.20 TOB ELEV. = 908.00 2' ENGINEERED SOIL (SEE TABLE) 4' 1' OPEN GRADED STONE WRAPPED IN NON-WOVEN GEOTEXTILE FABRIC 6" UNDERDRAINTOE ELEV. = 903.20 TOE ELEV. = 903.20 TOB ELEV. = 907.00 TOB ELEV. = 908.00 CONTRACTOR SHALL SAW-CUT 10 LF OF EXISTING 131ST STREET PER DETAIL ON C800. CONTRACTOR TO SEEK BPW APPROVAL FOR ANY LANE CLOSURE AND WORK IN THE R.O.W., INCLUDING ANY REQUIRED M.O.T. NEEDED FOR THE CLOSURE. STR. 404A TC = 905.80 (SEE DETAIL SHT. C801) NATIVE VEGETATION NATIVE VEGETATION SOUTHEAST OUTLET Site Acreage=+/-0.76 ac. Offsite/Upstream Acreage=+/-0.76 ac. Volume Required: 0 cu.ft. Volume Provided: 0 cu.ft. Allowable Release Rate: 10yr = 2.00 c.f.s. 100yr = 4.61 c.f.s. Post Developed Release Rate: 10 yr = 1.67 c.f.s. 100 yr = 3.36 c.f.s. SOUTHWEST OUTLET Site Acreage=+/-0.57 ac. Offsite/Upstream Acreage=+/-0.00 ac. Volume Required: 0 cu.ft. Volume Provided: 0 cu.ft. Allowable Release Rate: 10yr = 2.14 c.f.s. 100yr = 5.01 c.f.s. Post Developed Release Rate: 10 yr = 1.20 c.f.s. 100 yr = 2.57 c.f.s. BACK TO BACK = 906.06 PROPOSED 2" WATER SERVICE PROPOSED 6" WATER LINE WATER SERVICE DETAIL 07 / 3 0 / 2 4 R E V I S E D P E R W A T E R C O M M E N T S B M B