Loading...
HomeMy WebLinkAbout07040223 Master Permit CAMBRIDGE II - ELEV 2C LEFT HAND - Brick 3 Sides FULL BSMT - 9' Walls 3 CAR - Side Entry Wd Deck "2" Gar. FFE ~ 766.2 1st Fir FFE ~ 768.0 TOW = 767.0 Bsmt FFE ~ 758.2 Drive Slope ~ 2.6% "BASE HOUSE STANDARD FEATURES" 9' FULL BASEMENT 3 CAR SIDE ENTRY GARAGE BRICK 3 SIDES PATIO (2) 4X4 WINDOW WELLS & (1)2X2 WINDOW WELL "SELECTED FEATURES" DECK "2" " " I '" ~ x::2:J> _ ~ 00 Lu LlJ-.Ju) ~ B ffi ~ ill N l1.. W Z "' o " N 0 --~ -- 44.33' \ \ e . " w U N =~ w. ~" Q~ ~" roO ~'" ~ U I ~ ~ N "w _ :U;O '<::t (") ~~ LO 0> 0) z \ I -,0' "'" f-~O \ I :i'wO ",>w W>-f- lo~:5 ~~ ":i'::J W<.9 w '" \ 130.49' Cone Flatwork Sq. Ft = I1522 Public Walk Sq Ft = I442 Sod Sq Yds ~ I348 Seeding Sq Ft = :!:4619 Flood Hazard Note: Lot Number 170 ties partially within that Special Flood Hazard Zone "AE" and Zone "X" per revised location on the Flood Insurance Rate Maps for Hamilton County, Indiana (Community Panel #18057C0235F, dated February 19, 2003). LOMR, Case #05-05-1194A, dated January 27. 2005 Note: This drawing is based upon construction plans and/or record drawings prepared by others and is not based upon a field survey. COOR Consulting & Land Services, Corp_ does not warrant the correctness or integrity of this information_ The contractor/owner should verify existing conditions prior to construction. Any varying field conditions or any discrepancy with the information contained hereon should be immediately reported to COOR Consulting & Land Services, Corp., failure to do so would result in the contractor/owners assumption of liability oor@ @@[)i]i0lliJ01l0[)i]@ ~ OCID[)i]@ i0@[?WO@@i0~ @@I?~@I?CIDUO@[]j) 303 WEST MAIN STREET KNIGHTSTOWN. INDIANA (888) 593-2667 (765) 345-5943 FAX#: (765) 345-5692 DATE: 04/20/07 JOB #2003-100.170 REVISIONS: Note: Minimum Front yard - 25' Minimum Side Yard. 3' Minimum Aggregate - 6' (Between Houses) Mi urn ar Yard - NfA &~~lliJ[Jj]j)@@] U\!J@[f'[WU' ~ @~ '0" = ~@' I~ I~ IN w IW U >"1 0::: :i 0'" c 6~ IS~ <(0 (/)LD w z ::0 '" W f- " ;;; '" ,., 20_00' ~ ~ ~ oa::~ w~w ~05 I - ~ SAN LAT . oi. . " '" 30.0' -....... f--. <D N ~ 20' 313' ~ {]U] [( w it RECf!'._ ~ . .) " APR 2 5 SAfIJ, ~H 738"' tt'!!?65.32 IXX.XI = Proposed Grade - = Drainage Flow XX.X = Existing Grade Note: Contractor should verify site specific information depicted hereon with the approved construction plans for this development. Also. Contractor should reference Architectural plans for foundation orientation and dimensions. Note: The proposed construction grades, contours, and proposed structure elevations as depicted hereon are based upon information provided upon the approved construction documents prepared for this development. Unless otherwise stated hereon, no information pertaining to but not limited to, fluctuating water tables elevations, soil types. and conditions within the building areas of this development have been provided and \or referenced on said documents. With the excavation of the proposed structure foundations, certain care and observations should be made in regard 10 such conditions as soil types and fluctuating water tables. During the excavation process should any unsuitable soils or ground water be witnessed. the builder shall be immediately notified for further examination and consultation. At the builders discretion, additional construction techniques may be necessary to alleviate future problems. @1XI~~~'(7 @rm~~~ ~~U &:\ 'jJ~~~ ~[;.:@uO@ll!lcil INSTR. #200500009933 PC 3, SLIDE 580 C.O.C. #200500011991 PLOT PLAN Prepared For: ~ fi';lte:) ~.~ ~~~led_ LOT # 170 14028 SALMON DRIVE CARMEL. IN 46033 Pulle Homes of Indiana