Loading...
HomeMy WebLinkAbout07050013 Site Plan .' ...sn The Schneider Corpon.UOD 8901 otiI AT8Due BiItoric Port HarriJon Indlanopoill, !nd1aIla _'-1037 317-626-7100 317-626-7200 FAX ~ Suneylnj Lon_po .Irchltocture GJll.Ull Geology This Plot Plan Prepared For: Arbor Homes Lot # 57 ,containing 12,594 SJ.:t, in The Trails at Hayden Run Sec. 1 INSTR, # 200500069468 Clay Twp, Hamilton County See 20, T29N, R3E 3233 \\1NING5 LANE Westfield, IN 46074 Prepared Date: 04/18/07: By: KAG Plot Plan Legend []Q[Q] Proposed Grades 000.0 Exl.tlng Grades -000.0-- Contour Grode * Approx. Lateral Location - I - Sanitary Sewer Unes -" - Storm Sewer Unes - 1,/ - Water ServIce Unes - - - - - - - Sub-Surface Drain Unes l!Il ~onhole (Sanitary or Storm) . Beehlvs Inlst (Storm) IIIlI Curb Inlet (Storm) D End Section (Storm) ..II\. F1reH)':lrant - coo - 000 - Flow Une of swale (50'R/W) Community Restrictions: Side Yard =3' min. Rear Yard = N/A Aggregate = 6 (B.H.) ARBOR HO~ES Pad Grade = 921.2 per pian Pad Grade + 1.0' = Garage FIT (922.2) Garage FIT + 0.5' = Residential FIT (922.7) Residential FIT - 10.0' = Basement FIT (912.7 ) Orivewoy Slope = 5.3% Note: The 9arage finished floor ~evation is 2.1' above the curb at the drive, per plan. GROUND co;rn CALCULA 1l0NS: Drive = 921 SF i Public Walk =370 SFi Private Walk = 77 SF i Seeding = 6,505SFi Sod = 2.919 SFi , even with the rear of house. Note: Sanitary Sewer Top of Costing Information Upstream ~anhole, TC= 920.66 Downstream ~anhole, TC= 920.55 per record drawing. Note: The contractor Is to maintain a minimum distance of ten feet (10') between the sonltry sewer and water line laterals. 20' D.U.&S.S.E. I d N '" ~.H 1812 TC=920.66 PER RECORO DRA~NG . < < WININGS LANE ElEV=920,} pJ'~lloN PER PlloN .10.0' ~ ~ 2267 THREE CAR GARAGE BASEllENT 1:1 ~A mRHORN B ;Ii FR~&MSY RESlOENCE SOO 8 " 8 '" FLOOO HAZARD 5T A TEMENT CERllFlCA 1l0N ^\\II\\\\lllIlll/l/lIllilll. #~'\c:. l. ",'l/, # ~~...........,,~1'&,% ~ ~,"~G\SNTE:I?~""",.....o~ gg~....~ 0 O\;<>~ I ( 50303-) I ~ ... STATE OF .: $I ~ /..... ..... iff ~(A ',.:,I\ID'A~!':"" ~~ ~-Y#J .............C\" ~ ~//, SUR~ \,~\# 11/J/fllll/illllll\\\\\II\' O-c-lf-rl . ~.OO ~ '-^' <D <D "'- 66.6' 20' D.U.&S.E m 90,00' .~I .. " ....... This drawing is not intended to be represented 05 0 retrocement or original boundary survey, 0 route survey, or 0 Surveyor Location Report. Flood. Haz.ard Statement The accuracy of any flood hazard data shown on this report Is SlJbject to map scale uncertainty and to any other uncertainty In location or e1eYOtJon on the referenced flood insurance rote mop. All of the within described land OOES NOT UE wltll~ tIIat specld flood hazard zone A os said land plots by seal. on flood ~suronce rote mOj> # lB057C021l5F for City of Carmel, Indiana (map. doted February 19, 2003). Note: This drawing Is based on construction plans or record drawings, and is not based upon a field survey. The Schneider Corporation does not warrant the accuracy or sufficiency of this Information. Contractors should verify existIng conditions prIor to ony construction. Any discrepancy found on this drawing should be reported to The Schneider Corporation immediately; I foUlng to do so results in the contractors assumption of all 110bnlty. Note: The basement elevotlon, depleted hereon, has been determined end basod on the pod grades and/or contoors token from theconstructlon plans for this subdlvlslon. Unless stated, no Informatlco about fluctuating water tables, soD conditIons, or soD t)pes has been provided or stated on sold plans. ThIs lot Is located near a body of water. Lot or soD conditIons may require that the basement floor e1evotlon be held 2 foot above normal pool eleYOtlon. Site investigation may be needed If water Is encountered during the excowtlon process or If other known water e1evotlon or soDs coodltloos ore present. InvestlgotJoo and any remedIal procedures Is at the dlsaetlon of the buUder to determine and toke appropriate steps of action. If any ground water Is encountered during exooYOtlon the buUder 18 encouraged to contact The Schneider Corporotloo to discuss possible courses of action. NOTE: SU~P PU~P(S) TO BE PLACED BY BUILDER AS NEEDED. OetaD of t)plcol Storm Water flow pattern for lndlvlduallots. [Q] -M- -~- -- -- I Note: Bunder to ensure positive drainage away ~c':.~ri.15 from .tructure(s). PER RECORO ORA~NG S' WAU< 5.0 PER PL LOT # 57 VB # 07.0072325 IlU CURB ~ ~ =~= ~ 5' WAU< ~ ..... d N '" ~ Assumed North Scale: I. = 30' 20' D.&U.E ;;-::T'--- 25 B.L. 9':7' 10.0' ~ N '" 4 ' soo REVl~ON #1 FUPPED HANDING \1307.0072400 04/19/07 - KAG m N d N '" 1E ~. 5 b .:1 ~. t TYPICAL SWALE SECllON Note: Per Carmel zoning ordinance 26.1.1 : The residential district limits height to twenty-flve feet (25'). however a dw~l~g may be ~creased in height to tIIlrty-flve feet (35') provided the side and rear ){Irds are Increased on additionol one foat (1') for each one foat (1') tile structure exceeds the first twenty-flve feet (25') ~ helghl