HomeMy WebLinkAbout07050013 Site Plan
.'
...sn
The Schneider Corpon.UOD
8901 otiI AT8Due
BiItoric Port HarriJon
Indlanopoill, !nd1aIla _'-1037
317-626-7100
317-626-7200 FAX
~
Suneylnj
Lon_po .Irchltocture
GJll.Ull
Geology
This Plot Plan Prepared For: Arbor Homes
Lot # 57 ,containing 12,594 SJ.:t, in
The Trails at Hayden Run Sec. 1
INSTR, # 200500069468
Clay Twp, Hamilton County
See 20, T29N, R3E
3233 \\1NING5 LANE
Westfield, IN 46074
Prepared Date: 04/18/07: By: KAG
Plot Plan Legend
[]Q[Q] Proposed Grades
000.0 Exl.tlng Grades
-000.0-- Contour Grode
* Approx. Lateral Location
- I - Sanitary Sewer Unes
-" - Storm Sewer Unes
- 1,/ - Water ServIce Unes
- - - - - - - Sub-Surface Drain Unes
l!Il ~onhole (Sanitary or Storm)
. Beehlvs Inlst (Storm)
IIIlI Curb Inlet (Storm)
D End Section (Storm)
..II\. F1reH)':lrant
- coo - 000 - Flow Une of swale
(50'R/W)
Community Restrictions:
Side Yard =3' min.
Rear Yard = N/A
Aggregate = 6 (B.H.)
ARBOR HO~ES
Pad Grade = 921.2 per pian
Pad Grade + 1.0' = Garage FIT (922.2)
Garage FIT + 0.5' = Residential FIT (922.7)
Residential FIT - 10.0' = Basement FIT (912.7 )
Orivewoy Slope = 5.3%
Note: The 9arage finished floor ~evation
is 2.1' above the curb at the drive, per
plan.
GROUND co;rn CALCULA 1l0NS:
Drive = 921 SF i
Public Walk =370 SFi
Private Walk = 77 SF i
Seeding = 6,505SFi
Sod = 2.919 SFi ,
even with the rear of house.
Note: Sanitary Sewer
Top of Costing Information
Upstream ~anhole, TC= 920.66
Downstream ~anhole, TC= 920.55
per record drawing.
Note:
The contractor Is to maintain a
minimum distance of ten feet (10')
between the sonltry sewer and water
line laterals.
20' D.U.&S.S.E.
I
d
N
'"
~.H 1812
TC=920.66
PER RECORO DRA~NG
.
<
<
WININGS LANE
ElEV=920,} pJ'~lloN
PER PlloN
.10.0'
~
~
2267
THREE CAR
GARAGE
BASEllENT 1:1
~A mRHORN B ;Ii
FR~&MSY
RESlOENCE
SOO
8
"
8
'"
FLOOO HAZARD 5T A TEMENT
CERllFlCA 1l0N
^\\II\\\\lllIlll/l/lIllilll.
#~'\c:. l. ",'l/,
# ~~...........,,~1'&,%
~ ~,"~G\SNTE:I?~""",.....o~
gg~....~ 0 O\;<>~
I ( 50303-) I
~ ... STATE OF .: $I
~ /..... ..... iff
~(A ',.:,I\ID'A~!':"" ~~
~-Y#J .............C\" ~
~//, SUR~ \,~\#
11/J/fllll/illllll\\\\\II\'
O-c-lf-rl
. ~.OO ~
'-^'
<D
<D
"'-
66.6'
20' D.U.&S.E
m
90,00'
.~I .. " .......
This drawing is not intended to be represented 05 0 retrocement or
original boundary survey, 0 route survey, or 0 Surveyor Location Report.
Flood. Haz.ard Statement The accuracy of any flood hazard data shown on this report
Is SlJbject to map scale uncertainty and to any other uncertainty In location or
e1eYOtJon on the referenced flood insurance rote mop. All of the within described land
OOES NOT UE wltll~ tIIat specld flood hazard zone A os said land plots by seal. on
flood ~suronce rote mOj> # lB057C021l5F for City of Carmel, Indiana (map. doted
February 19, 2003).
Note:
This drawing Is based on construction plans or record drawings,
and is not based upon a field survey. The Schneider Corporation
does not warrant the accuracy or sufficiency of this Information.
Contractors should verify existIng conditions prIor to ony
construction. Any discrepancy found on this drawing should
be reported to The Schneider Corporation immediately; I foUlng
to do so results in the contractors assumption of all 110bnlty.
Note:
The basement elevotlon, depleted hereon, has been determined end
basod on the pod grades and/or contoors token from theconstructlon
plans for this subdlvlslon. Unless stated, no Informatlco about
fluctuating water tables, soD conditIons, or soD t)pes has been
provided or stated on sold plans. ThIs lot Is located near a body of
water. Lot or soD conditIons may require that the basement floor
e1evotlon be held 2 foot above normal pool eleYOtlon. Site investigation
may be needed If water Is encountered during the excowtlon process
or If other known water e1evotlon or soDs coodltloos ore present.
InvestlgotJoo and any remedIal procedures Is at the dlsaetlon of the
buUder to determine and toke appropriate steps of action. If any
ground water Is encountered during exooYOtlon the buUder 18
encouraged to contact The Schneider Corporotloo to discuss possible
courses of action.
NOTE:
SU~P PU~P(S) TO BE PLACED
BY BUILDER AS NEEDED.
OetaD of t)plcol Storm
Water flow pattern for
lndlvlduallots.
[Q]
-M-
-~-
-- --
I
Note: Bunder to ensure
positive drainage away
~c':.~ri.15 from .tructure(s).
PER RECORO ORA~NG
S' WAU<
5.0
PER PL
LOT # 57
VB # 07.0072325
IlU CURB
~
~
=~=
~
5' WAU<
~
.....
d
N
'"
~
Assumed North
Scale: I. = 30'
20' D.&U.E
;;-::T'---
25 B.L.
9':7'
10.0'
~
N
'"
4 '
soo
REVl~ON #1
FUPPED HANDING
\1307.0072400
04/19/07 - KAG
m
N
d
N
'"
1E
~.
5
b
.:1 ~. t
TYPICAL SWALE SECllON
Note:
Per Carmel zoning ordinance 26.1.1 : The residential
district limits height to twenty-flve feet (25'). however
a dw~l~g may be ~creased in height to tIIlrty-flve
feet (35') provided the side and rear ){Irds are Increased
on additionol one foat (1') for each one foat (1') tile
structure exceeds the first twenty-flve feet (25') ~
helghl