Loading...
HomeMy WebLinkAboutPool Specifications16' X 40' RECTANGLE - 6"R STEEL WALL POOL SYSTEM DWG #: GS-27137 PAGE 1 OF 3 DATE: 7/30/2024REV: - AREA (SqFt): 640 PERIMETER: 112 EST. VOL (US Gal): - Signage must be permanantly attached around the perimeter of the pool. THIS DOCUMENT IS FOR ILLUSTRATIVE PURPOSES ONLY. Only Alpha Pool Products makes only those representations which are stated in its written warranty. Any other representations, statements, or contracts made by the dealer/contractor to the customer regarding any components produced by Only Alpha Pool Products are attributable to the dealer/contractor only. The dealer or contractor who sells or installs your pool is an independant contractor and is not an agent or employee of Only Alpha Pool Products. The construction methods illustrated here are suggestions and apply only to normal ground conditions. There may be additional precautions and/or methods of construction. The responsibility is the contractor's. -A safety line, with buoys, is to be permanently attached 1'-0" to the shallow side of the point of first slope change. -Different methods and precautions may be dictated by various ground conditions. This is to be determined by and is the responsibility of the contractor who is not an agent of the manufacturer of the component parts. -Installation is to be done in accordance with all federal, state and local building codes, as well as A.N.S.I./N.S.P.I. suggested standards. -BOTTOM SPECIFICATIONS MUST MEET OR EXCEED A.N.S.I./N.S.P.I./A.P.S.P. RECOMMENDED STANDARDS -'NO DIVING' signage must be permanently attached to the entire perimeter of the pool. See instructions with signage. -IT IS RECOMMENDED TO NOT INSTALL DIVING BOARDS AND/OR SLIDING EQUIPMENT ON RESIDENTIAL POOLS. If diving boards and/or sliding equipment is installed by the contractor, such diving boards and sliding equipment MUST BE INSTALLED WITHIN THE GUIDELINES ESTABLISHED BY ANSI/NSPI/ASPA RECOMMENDED STANDTARDS, AND IN ACCORDANCE WITH ALL APPLICABLE STATE AND LOCAL CODES AND REGULATIONS. BILL OF MATERIALS DESCRIPTIONPART NUMBERQTY Stl Stp 16' Straight Step - 3 Tread (bead) (Internal - Auto Cover)SDS-0684SP1 Stl Pnl 48"x42" Plain - 1 RibST-4801-0684-L1 Stl Pnl 48"x42" Plain - 1 RibST-4801-0684-R1 Stl Stp (Spl) 6"R - 16' Bench (Permaform)(bead)SDS-1830SP1 Stl Pnl 24" - 19" Standard Bench Wall (Left)ST-2400-19BNW-L1 Stl Pnl 24" - 19" Standard Bench Wall (Right)ST-2400-19BNW-R1 Stl Pnl 60"x42" Plain - 1 RibST-60014 Stl Pnl 96"x42" Plain - 2 RibsST-96029 Stl Pnl 96"x42" Skimmer Center (1085) (Auto Cover-1.125) - 2 RibST-9602SCL-AC1 *THIS DRAWING REPRESENTS CUSTOMER SPECIFICATIONS. *YOUR SIGNATURE ACKNOWLEDGES ACCEPTANCE. SIGN:___________________________ DATE:____________ CUSTOMER: C-RAY TAG: HORN BRACE / HARDWARE OPTIONS QTY PART NUMBER DESCRIPTION 4 CU-0601FCR Cmp 6"R / 90 deg Foam Corner-1/ea 4 ST-9001CR Stl Pnl 90 Deg Corner - S/1 14 ST-1002CCB Stl Brc C-Channel Turnbuckle Brace + Drive Stake 1 HW-2002 Hdw Steel/Rrd Kit 1 HW-2013 Hdw Steel Add-on Kit (3/8" Bolts-100, 3/8" Nuts-100) COPING QTY PART NUMBER DESCRIPTION 1 HW-2018 Hdw Auto-Cover, No-Diving Plate(7/Bag) ST-9602 ST-9602 ST-9602 ST-9602 ST-9602SCL-AC ST-6001 ST-9602 ST-9602 ST-4801-0684-L ST-6001 ST-4801-0684-R ST-6001ST-9602ST-6001 16 ' - 0 " 40'-0" 6'-0" 43'-1" ST-9602 ST-9602 ST-2400-19BNW-R ST-2400-19BNW-L SDS-1830SP ST-9001CR (x4) CU-0601FCR (x4) 16' X 40' RECTANGLE - 6"R STEEL WALL POOL SYSTEM DWG #: GS-27137 PAGE 2 OF 3 DATE: 7/30/2024REV: - AREA (SqFt): 640 PERIMETER: 112 EST. VOL (US Gal): - Signage must be permanantly attached around the perimeter of the pool. THIS DOCUMENT IS FOR ILLUSTRATIVE PURPOSES ONLY. Only Alpha Pool Products makes only those representations which are stated in its written warranty. Any other representations, statements, or contracts made by the dealer/contractor to the customer regarding any components produced by Only Alpha Pool Products are attributable to the dealer/contractor only. The dealer or contractor who sells or installs your pool is an independant contractor and is not an agent or employee of Only Alpha Pool Products. The construction methods illustrated here are suggestions and apply only to normal ground conditions. There may be additional precautions and/or methods of construction. The responsibility is the contractor's. -A safety line, with buoys, is to be permanently attached 1'-0" to the shallow side of the point of first slope change. -Different methods and precautions may be dictated by various ground conditions. This is to be determined by and is the responsibility of the contractor who is not an agent of the manufacturer of the component parts. -Installation is to be done in accordance with all federal, state and local building codes, as well as A.N.S.I./N.S.P.I. suggested standards. -BOTTOM SPECIFICATIONS MUST MEET OR EXCEED A.N.S.I./N.S.P.I./A.P.S.P. RECOMMENDED STANDARDS -'NO DIVING' signage must be permanently attached to the entire perimeter of the pool. See instructions with signage. -IT IS RECOMMENDED TO NOT INSTALL DIVING BOARDS AND/OR SLIDING EQUIPMENT ON RESIDENTIAL POOLS. If diving boards and/or sliding equipment is installed by the contractor, such diving boards and sliding equipment MUST BE INSTALLED WITHIN THE GUIDELINES ESTABLISHED BY ANSI/NSPI/ASPA RECOMMENDED STANDTARDS, AND IN ACCORDANCE WITH ALL APPLICABLE STATE AND LOCAL CODES AND REGULATIONS. C-CHANNEL BRACE *THIS DRAWING REPRESENTS CUSTOMER SPECIFICATIONS. *YOUR SIGNATURE ACKNOWLEDGES ACCEPTANCE. SIGN:___________________________ DATE:____________ CONCRETE FOOTER 1-PIECE ANGLE BRACE STEEL POOL PANEL STAKE 2" POOL BASE 2' TURNBUCKLE 6'-0" 40'-0" 16 ' - 0 " ST-6001 ST-9602 ST-6001ST-4801-0684-R ST-6001ST-4801-0684-LST-9602ST-9602ST-6001 ST-9602SCL-AC ST-9602 ST-9602 ST-9602 ST-9602 CUSTOMER: C-RAY TAG: HORN 10 ' - 0 " 3' - 0 " 3' - 0 " 6'-0" 3'-4" 6' - 0 " 3' - 4 " 3' - 4 " 1'-7"3'-0" 2'-0" 15'-0"18'-5" 10'-1" 1 8 '- 1 0 7 8 " 24'-43 4" ST-2400-19BNW-R ST-2400-19BNW-L ST-9602 ST-9602 SDS-1830SP