Loading...
HomeMy WebLinkAbout07050082 Site Plan , '-., Schneider Note: This drawing is based on construction plans or record drawings, and is not based upon a field survey. The Schneider Corporation does not 'NmT1Jnt the accuracy or sufficiency of this lnfonnotfon. Contractors should verify existing conditions prior to any construction, MY discrepancy found on this drawing should be reported to The Schneider Corporation immediatelY, faHing to do so results In the contractors assumption of all lIobntty. Plot Plan legend Note: []Q[[] Proposed Grades The basement e1evatJon, depicted hereon, hos been determined and bosed 000.0 Existing Grades on the pad grades and/or contOUnl token from the constructJoo pions for -000.0-- Contour Grade this subdMslon. Unless stated, no Information about fluctuating water * Approx. Lateral Location tables. soD conditions. or son t)pes has been provided or stated on sold _ 8 _ Sanitary Sewer Unes plans. Thlelot Ie located near a body of water. Lot or soD. condItions may _ II' _ Storm Sewer Unes require that the basement floor elevation be held 2 foot aboYl'l normal _ IJ _ Water Service Unes pool elevation. SIte Investlgotlon may be needed If water Is encountered _ _ _ _ _ _ _ Sub-Surface Drain Unes during the excovatlon process or If other known water ele~Uon or SOn8 . Manhole (Sanitary or Storm) c~dltlOf1s are pr6S80t. Investlgatlon and ooy remedial procedures Is at the . B ehf I I t (St) dlscretron of the bullder to determine and take approprlotelstepS of IlIII ~rb ~el ~ e(St orm) actron. If any ground water Ie encountered during excovatl~ the bunder Is D End Sen etl (oSrm ) encouraged to contact The Schneider Corporatlon to discuss possible c on tom courses of action. ..... Fire Hydrant NOTE: -.,. -... - Flow Une of ,wale LOT # 60 SUMP PUMP(S) TO BE PLACED BY BUILDER AS NEEDED. VB # 07.0073230 The Schneider CorporaUon 8901 otiJ Avenue Historic fort. HarriIon lndlAuapou., ladlana 462l6-1037 317-626-'7100 3l?-826-?2oo FAX This Plot Pion Prepored For: Arbor Homes Lot # 60 ,contoining 15,676 S.F.:t, in The Troils ot Hoyden Run Sec. 1 INSTR. # 200500069468 Cloy Twp, Homilton County Sec 20, T29N, R3E 3269 WININGS LANE Westfield, IN 46074 Prepored Dote: 05/04/07: By: KAG (50'R/W) Community Restrictions: Side Yard ~3' min. Rear Yard = N!A Aggregate = 6 (B.H.) ARBOR HOMES Pad Grade = 920.7 per plan Pad Grade + 1.0' = Garage m (921.7) Garage m + 0.5' = Residential m (922.2) Residential m - 9.0 ' = Basement m (913.2 ) Driveway Slape = 3.3% Note: The garage finished floor elevation is 1.4' above the curb at the drive, per plan. GROUND COVER CALCULA nONS: Drive = 720 SF t Public Walk = 712 SF t Private Walk = 69 SF:!: Seeding = 7,283SH Sod = 6,562 SF:!: , even with the rear of house. FLOOD HAZARD STATEMENT CERnFICA nON ,\II\\\\\\\\\IIII/I/I//i//1. #"'\'S L C, ~~ ~~~.........:.......4'.0-~ ~ ~...,~..G\S Tef?i-.....";AO~ '" "" i<(- No 0...-",,,,, 2:2~.. ". ~ f ( 50303 ) i ~ .... STATE OF ,.: ~ \ ~~........IIVDI Atl.~......\S..~ ff o 7Am'" ....-.1' ~ "" "v""""" ("' i$' ~J/, SUR~ \.~\~ WII//iI/IiIIIII\l\\I\\I\\' -\::L.. l . f11 ED&Inoering Surv'lini LandBcape ArchItecture GlB.lJll Geology Note: Sanitary Sewer Top of Costing Information Upstream Monhole, TC= 920.66 Downstream Monhoie, TC= 920.55 per record drawIng. Note: The contractor is to maintain a minimum distance of ten feet (10') between the san/try sewer and water line laterals. ~ ~ =~= ~ Assumed North Scale: 1- = 30' Detail of t)lllcal Storm Water flow pattern for Individual lots. t:s \ "\ ! '- I ~ ! I \ I "\ ~ Note: Builder to, ensure posItive drainage away "- from ,tructure(s). M.H.1811 TC=920.55 PER RECORD DRA\\ING 1$12 - - ;.E. \---- ~iR=:ff!:o 20' D.U.&S.~ '~:g. ~ 7' B, '" 25.7 68.32 5' WAlK ~ 5.0' PER PlAN 5.0' ROll CURB < .. PER PlAN '" '" '" 5' WAlK .. 54.32' "' '<5 36.0' '-" 26.0' 20' D.&U.E -- 25'lii- '"' ;g ~ '<5 :.... s@ 27.9' ~ -l'> o en o. " " '01). ""'-" \:{r' " <??> " . o' ''''-r<" " {r, 0I).~ " " " .?> " .",.!' , .(' , 01). ",/ './ . \)~ , ,? 1>,'0 ~. \-. I>,U' c,.~' I;.S;" \-'i.-' '\)'i.-' R~' "'~<<- ~'i.-Jll,'). Xl I;. \.~~\j~'\) ~,':J'!J ,'I> <' ~". ~". <' ,~\j-{f- This drowing is not intended to be represented as a retracement or original boundory survey, 0 raute survey. or a Surveyor Location Report. Flood Hazard Statement: The accuracy at any flood hazard data shown on thIs report Is sub}eet to map scale lJl'looalnty and to any other uncertainty In locatlon or elevation on the referenced flood insurance rote map. All. of the within described land DO€S NOT UE within that special ftood hazan! zane A as said land plots by scale an flood In..ranc. rate map # 18057C0205F far City of Carm~, Indlano (mapa dated February 19. 2003).