HomeMy WebLinkAbout07050023 Site Plan
~~
Schneider
Note:
This drawing is based on construction pions or record drawings.
and is not based upon 0 field survey. The Schneider Corporation
does not warrant the accuracy or sufficiency of this Information.
Contractors should verify existing conditions prior to any
construction. Any discrepancy found on this drawing should be
reported to The Schneider Corporation Immediately; falling to do
so results in the contractors assumption of 011 liability.
Note:
Plot Pion legend The basement elevation. depIcted hereon. has been delennlned and bosed on
[]QQ]] Proposed Grades the pod grades and/or contoors token from the construction plans for this
000.0 ExIsting Grades aubdMslon. Unl889 slaled, no InformatIon about fluctuating water tables, lIOn
-- 000.0-- Contour Grode conditions. or soD t)pes has been provided or stated on SCI1d pions. This lot
* Approx. loteral Location Is located near a body of water. Lot or soil conditions may require that the
-O-SonltorySewerUnes b 1ft I II b h"d2f
If st S Un OS9men oor e evo on e III oot above nannal pool elevation. Site
- u - Wormt S ew7'" U es Investigation may be needed If water Is encountered during the excawtloo
--.- oar ervIce nes
_ _ _ _ _ _ _ Sub-Surface Drain Unes process or If other known water e1eyt)tlon or sons condItions ore present.
. Manhole (Sanitary or St~V8Stl9atlon ond any remedIal procedures Is at the dlBa"8tlon of the buDder
.. BeehIve Inlet (Storm) determine and take appropriate steps of action, If any ground water Is
l1li Curb Inlet (Stonn) encountered during excayt)tlon the builder Is encouraged to contact The
D End Section (Storm) S<:hnelder CorporatlOfl to dl8tU8S possible courses of actlOfl.
... Fire Hydrant NOTE:
- . . . - . . . - Fiow Une of swale SUMP PUMP(S) TO BE PLACED
BY BUILDER AS NEEDED.
LOT # 27
VB # 07.0070893
~
~
=~=
,.......c...v l"')t.: "'"
-'/ l.y-
The Schneider CorporaUon
8901 0Ua AmlU8
IIiaIoria Forlllarrison
IndlAnapollB, Indiana _6-1037
317-626-7100
317-828-7200 FAX
EnaineerIng
S1ImJlng
LandJcape ArclJIlocture
GIll'1lB
Geology
This Plot Plan Prepared For:
Trinity/Beozer Homes
Lot # 27 , containing 6,366 S.F.:!:, in
Yorktown Woods
Section # 1
Instrument # 200600017282
C.O.C. # 200600023419
P.C. # 4, Siide # 48
Hamilton County, Clay Township
Section 19, Township 18 N, Range 4 EAST
2606 HIGHMOUNT COURT (50 ' R/W)
Carmel, IN 46033
Prepared Dote: 03/27/07 : By: KAG
Community Restrictions:
Side Yard = 6' (BH)
Rear Yard = 20'
Zoning = ROSO III
Finished Fioor Elevation Information
Pad Grade = 825.13 per plan
Pad Grade + 0.33' = Garage FFE (825.4ll)
Garage FFE + 1.04' = Residential FFE (826.5 )
Residential FFE - 10.0' = Basement FFE {816.5
Driveway Slope = 3.8%
Note: The garage finished fioor eievation
is 2.0' above the curb at the drive, per
plan.
Ground Cover Calculations:
Drive = 882 SF:!:
Public Walk = 219 SF:!:
Private Walk =6 SF:!:
Rear Yard = 1,408 SF:!:
Sod = 1,815 SY:!: , from rear of home.
Note: Sanitary Sewer
Top of Casting Information
Upstream Manhole, TC= 822.69
Downstream Manhoie, TC=824.65
Per Record Drawing
Note: The contractor Is to maintain
a minimum distance of ten feet (10')
between the sanitary sewer and
water line laterals.
\
~
FLOOD HAZARD STATEMENT
CERnFICA nON
,\\\\\\\\111111111111/////1.
~\\\ L c}~
~~~..."",,:,,",,.'(&~
~ <..~..,~ G\S Tt~i"',,""""<>~
'" c:::;--.'.~v No "..;<>~
i ( 50303 "; )
-a: ". STATE OF." ~
~ /.... ....<:\ tf
~/ """.I;-.(,lvorA~!':"" f:'\.~~
%;::t "sUR'~ \ ~~
////Il/illlllllll\\\\\\\\\\
"-"-l~
This drawing is not intended to be represented as 0 retracement or
original boundary survey, a route survey, or a Surveyor Location Report.
Fiood Hazard Statement: The accuracy of any flood hazard data shown on
this plot plan Is subject to map scale uncertainty and to any other
uncertainty in location or elevation on the referenced flood Insurance rate
mate (FlRM). None of the within described land lies within that special fiood
hazard zone "A", os said land plots by scaie on Community Map Panel #
18057C 0026 F of the fiood insurance rate maps (fiRM) for the city of
Carmel, Hamilton County, Indiana, Dated February 19, 2003.
\
Detan of t)plcal Ground
Water flow pattern for
Indl>iduoJ lots.
~
Assumed North
Scale : 1" = 30'
t\
Note: Builder to ensure
positive drainage away
from structure(s).
/'
MHfJ
TC=824.85
PER RECORD
DRA\\1NG
NOTE:
IN THE RESIDENTIAL DISTRICTS UMITlNG
HEIGHT TO TWENTY-FIVE (25) FEET, A
DWELLING MAYBE INCREASED IN HEIGHT
TO THIRTY-FIVE (35) FEET PROVIDED
THE SIDE AND REAR YARDS ARE
INCREASED AN ADDITlONAL FOOT FOR
EACH FOOT SUCH STRUC'TURE EXCEEDS
TWENTY-FIVE (25) FEET IN HEIGHT.
PER CARMEL ZONING ORDINANCE 26.1.1.