HomeMy WebLinkAbout07050098 Site Plan
'CP
::0
IT!
"
IT!
<:
IT!
t:J
~
:1>-
-<
1-..0.
1-..0.
....,
~
"BASE HOUSE STANDARD FEATURES"
BUCKINGHAM" ELEV 3C
RIGHT HAND" Full Brick
FULL BSMT " 9' Walls
3 CAR" Side Entry
Gar. FFE = 914.0
1st Fir FFE = 915.8
TOW = 914.8
Bsml FFE = 906.0
Drive Slope = 2.1%
9' FULL BASEMENT
3 CAR SIDE ENTRY GARAGE
BRICK 3 SIDES
PATIO
(2) 4X4 WINDOW WELLS & (1) 2X2
WINDOW WELL
"SELECTED FEATURES"
&~%~(\J][)j]jJ@@] !Rl@['P'U[}\\
~@ii10@g 'iJ" = ~@'
BRICK 4 SIDES
Noto:
Minimum Front yard - Variable
Minimum Between Residences. 6'
Minimum Rear Yard - 20'
SAN MH 818
TC=910.54
'"
~
UJ
V)
~
V) 12.
'"
z "
0
"
~ I
/ I :s:
26.0' I
I IW
u
/ > 'I'
lJ
~ 5AN b 0::: '"
'-", "
" ~ 0 e :s:
,., / 0 ~~
", 0
"'_ (f)'
Ol- ..-
z~
-~ I~b
,",0
0"'
=>
m
u..LCJ
iiJ~r=""''''''T"'--""--''--''''---''''''''"''''-
I I ~
~ ~
! I
I I
w
~ I
I
I
l--1~
.w
~<C
:0 . "
o(l~O
'if '"-0
,Clad .
<o::::wO
Ori~O
<(::< ..-
>.
--'
06
G6.5'--
STM MH
TC=910.00
Cone Flatwork Sq. Ft = 10169.0]
Public Walk Sq Ft = 10500
Sod Sq Yds = 10360
Seeding Sq Ft = :t796B '. .....
lXK&I = Proposed frade
___ = Drainage flow
xx.x = Existing Grade
Contractor should velify site specific information depicted
hereon with the approved construction plans for this .
development. Also, Contractor shOuld reference Archltectuml
plans for foundation orientation and dimensions.
Flood Hazard Note:
I
The proposed oonstruction grades, contours, and proposed ,structure
elevations as depicted hereon are based upon Information provided
upon the approved construction documents prepared for IhlS
development. Unless otherwise staled hereon, no infonnaUon
pertaIning to but not limited to, fluctuating water tables elevations,
soil types, and conditions withIn the building areas of this :
development have been provided and \or referenced on said
documents, With the excavaool1 of the proposed structure
foundations, certaIn care and observations should be made In regard
to such conditions as soil types and fluctuating water tables. During
the excavation process should any unsuitable soils or ground water
be wItnessed the builder shaU be Immediately noUfled for further
examination ~nd consultation, At the builders discretion, adchtlonal
construction techniques may be necessary to alleviate future
problems. I
Lot Number 34 lles withIn Flood zard Zone "X. per the
scaled location on the Flood Ins ranee R~te Maps for
Hamilton County. Indiana (CO nunity Panel #18057C020
dated February 19, 2003).
Note;
Note:
This drawing is based upon construe on plans andfOf record
drawings prepared by others and is nol based upon a field sul'\ley.
COOR Consulting & Land Services, Corp. does not warrant the
correctness or integrity of this Information. The contractor/owner
should verify existing conditions prior to construction, Any varying
field conditions or any discrepancy with the (nfonnatlon contained
hereon should be immediately reported to COOR Consulting & Land
Services, Corp.; failure to do so would result in the conlractor(owners
assumption of liability.
PLOT PLiAN
Prepared For:
LONGRIDGE ESTATES
SECTION ONE
PC 3, SLIDE 729
INSTR #200500063316
oor@
@@[]j]@Q!JOtlOITUi]] (;}, O@[JiJ@ @@1J'\Y70@@~~
@ @ 1'1 lJD @ \1' ~1 t\ ~ @ [Ji\
303 WEST MAIN STREET KNIGHTSTOWN. INDIANA
(888) 593-2667 (765) 345-5843 FAX#: (765) 345-5692
DATE: 05110/06 JOB #2004-2!iO.034 REVISIONS: 1
LOT#34
13680 FOSSIL DRIVE
WESTFIELD, IN 46074
n.~-
r~;rID