HomeMy WebLinkAbout05110130 Site Plan
BUCKINGHAM
ELEV-6C-RT HAND
FULL BSMT- 9' WALLS
3 CAR- SIDE ENTRY
FULL BRICK
DECK "B"
'p,V'Ml
If () i~eOILl&f
/
177771
-=
90.00'
-./
1776.81
SAN MH
TC=777.2
SAN SWR
15' D.U.&S.S.E.
Cone Flatwork Sq. Ft = :1:1598
Public Walk Sq Ft = :1:360
Sod Sq Yds = :1:320
Seeding S Ft = :1:7393
SAN MH
TC=778.9
;..,
.,:
....
..:
j
~
-.......
n. ..
. .
......... ..........
...'.......... .........."
.......-...... ..............
.....,........ '......,....",
............. '..........--.
....._'....... ...............
.............- ..............
.............................
........................ '..'... ..............
....-.... '........-....
.....-.-. ....-........
........m ..._."....,
............ ........
...................."..
..".u__ ."........
..............,.-...
.....-..-.........
@ 0
1780.51 CO
6.3' ~
\l 8SMr <.D
0
CO eUCKINGHAM 6 ~
~ (fULL 8SMT)
<.D I I
~
1780~ 1778.51
&\llg\{!j]IJlliI@@] 1i!J@1?ll0il
@@1IDD@~ ~" = :1J@'
I&R:ZI = Proposed Grade
- = Drainage Flaw
LOT #3
+14562 SF
PAD 780.0 PER PLAN
1779.51
80.5
. '" I L .. 22.6"
. \:;; - }'~K-
B~_ -
20lj D.&U.E. ""\
j ~~
90.00' .
1777.51
Flood Hazard Noto:
Lot Number 3 lies within that Special Flood
Hazard Zone "X" per the scaled location on the
Flood Insurance Rate Maps for Hamilton County,
Indiana (Community Panel #18057C0227F, dated
February 19. 2003).
4 WAl
2' CURB W\SSO
TC-777.2
CHERRY CREEK BLVD
85' R\W (60' BC-BC)
Note:
.
-J
The proposed construction grades depicted
hereon are based upon iMarmellon, prop,osed
grades and/or contours, taken fram the approved
construction plans prepared for this subdIvision.
Unless stated hereon, no Infoonation pertaining to
but nollirnited 10, fluctuating water table
elevations, soil types or conditions within the
building area of saId lot, has been provided or
referenced on said plans. With the construction of .
a basement, It is recommended that the lowest
noor elevation be constructed at least two (2) feel
above any adjoining bodies of water unless a
study of facts reveals otherwise. Should any
ground water be witnessed during the excavation
of said structure, the lowest Roar elevallon should
be raised at least I:wo (2) feet above the ground
water level and additional construction techniques
should be Incorporated to alleviate future
problems.
WATER LINE
_w_ -w-
@: "1cd'/.. L-:1~t'
ISD'-"H ""jl-, "'''$.,.~ 5oJ:,~
GAR FFE :: 780.8
FFE = 782.8
BSMT FFE = 773.1
DRIVE SLOPE:: :1:6.9%
Note:
,
,
i
i
I
@@[Jj]~(l,j]Ot\DIJj]\ID ~ OOO[Jj]@] ~@IJ'\'!lD@@~g
_@ @..._~__[P.)___ ~_~.___~__~_O___~____~_
103 WEST MAIN STREET KNIGHTSTOWN. INDIANA i
888) 593-2667 (765) 345-5943 FAX#: (765) 345.5692 I
)ATE: 08\15\03 JOB #2003-100.003 REVISIONS:1 I
"
This drawing Is based upon construcUon plans
and/or record drawings prepared by others and Is
not based upon a neld survey. COOR Consulting
& Land Services, Corp. does not warrant tho
carrectness or Integrity af this InfannaUon. The
conlractorfowner should verify existIng condlUons
prior to construction. Any varyIng field conditions
or any discrepancy with the Informatlon contained
hereon should be immediately reparted to COOR
ConsulUng & Land Servicos, Corp.; failure to do so
would result In the contractor/owners assumption
of liability.
oor~
.... .._____ u"___'''__'''___''_-'__
CHERRY CREEK I PLOT PLAN
ESTATES I Prepared For:
SECTION 1 B ..
"ESTATES" I ~
UNRECORDED PLAT lJh~tP.~
LOT #3 r~<'R:;V
CHERRY CREEK BLVD.
CARMEL, IN 46032
Pulte Homes of Indiana