HomeMy WebLinkAboutPacket for HO 11-25-24W MAIN ST
BR
I
G
H
T
O
N
L
N
SI
X
P
O
I
N
T
S
R
D
B
R
I
G
H
T
O
N
A
V
E
BR
I
G
H
T
O
N
A
V
E
W MAIN ST
NOTTINGHAM CT
W MAIN ST W MAIN ST
ArcGIS Web Map
Parcels Address Points Street Ownership
Carmel
11/14/2024, 5:33:55 PM
0 0.04 0.080.02 mi
0 0.07 0.140.04 km
1:3,385
BESPOKE CONSTRUCTION, LLC
S C H N E I D E R R O B @ B E S P O K E I N . C O M
A T T :
01
P A G E O F11
R O B
VARIANCEP
R
O
J
E
C
T
3 1 7 ∙ 9 9 9 ∙ 5 5 4 1
V
E
R
S
I
O
N
1.
3
C
R
E
A
T
E
D
11
/
1
2
/
2
0
2
4
C 3
C A B I N E T C O.
PROJECT
AREA
PROJECT NO
S C H N E I D E R _ VARIANCE
P L O T P L A N
S C A L E
N T S
8575 ZIONSVILLE RD
INDIANAPOLIS, IN 46268
52'-
0
"
30'-5"
27
'
-
0
"
S P E C S
F O U N D A T I O N
• 8x8x16" REINFORCED & BLOCK-
FILLED CMU
• 4" CONCRETE SLAB
F R A M I N G
• 2" x 6" WALLS
• 11-3/4" LVL HEADERS
C L A D D I N G
• CONCRETE SIDING
• STANDING SEAM METAL ROOF
BESPOKE CONSTRUCTION, LLC
S C H N E I D E R R O B @ B E S P O K E I N . C O M
A T T :
02
P A G E O F11
R O B
VARIANCEP
R
O
J
E
C
T
3 1 7 ∙ 9 9 9 ∙ 5 5 4 1
V
E
R
S
I
O
N
1.
3
C
R
E
A
T
E
D
11
/
1
2
/
2
0
2
4
C 3
C A B I N E T C O.
PROJECT
AREA
PROJECT NO
S C H N E I D E R _ VARIANCE
O V E R V I E W
S C A L E
N T S
8575 ZIONSVILLE RD
INDIANAPOLIS, IN 46268
3'
-
0
"
1'
-
0
"
MA
X
1'-4"
8"
• GRADE
4" CONCRETE SLAB
TOP IS 6" MIN. ABOVE GRADE
6MM VAPOR BARRIER
R10 RIGID INSULATION
#4 REBAR
CONTINUOUS HORIZONTAL
SILL ANCHORS EVERY 6'
AND 6" IN CMU
#4 REBAR
VERTICAL
2'-0"
8" x 8" x 16"
BLOCKFILLED CMU
2x PRESSURE TREATED
SILL PLATE
4"
BESPOKE CONSTRUCTION, LLC
S C H N E I D E R R O B @ B E S P O K E I N . C O M
A T T :
03
P A G E O F11
R O B
VARIANCEP
R
O
J
E
C
T
3 1 7 ∙ 9 9 9 ∙ 5 5 4 1
V
E
R
S
I
O
N
1.
3
C
R
E
A
T
E
D
11
/
1
2
/
2
0
2
4
C 3
C A B I N E T C O.
PROJECT
AREA
PROJECT NO
S C H N E I D E R _ VARIANCE
F O O T E R & F O U N D A T I O N
S C A L E
N T S
8575 ZIONSVILLE RD
INDIANAPOLIS, IN 46268
17
'
-
4
1
/
2
"
3'
-
0
"
1'
-
0
"
S P E C S
• 2x PRESSURE TREATED SILL PLATE
• 2 x 6" EXTERIOR WALLS
• 2 x 4" INTERIOR WALLS
• 12" RAFTERS
• 3/4" SHEATHING ON ROOF AND WALLS
BESPOKE CONSTRUCTION, LLC
S C H N E I D E R R O B @ B E S P O K E I N . C O M
A T T :
04
P A G E O F11
R O B
VARIANCEP
R
O
J
E
C
T
3 1 7 ∙ 9 9 9 ∙ 5 5 4 1
V
E
R
S
I
O
N
1.
3
C
R
E
A
T
E
D
11
/
1
2
/
2
0
2
4
C 3
C A B I N E T C O.
PROJECT
AREA
PROJECT NO
S C H N E I D E R _ VARIANCE
F R A M I N G S I D E V I E W
S C A L E
N T S
8575 ZIONSVILLE RD
INDIANAPOLIS, IN 46268
5 1/
2
"
1'
-
2
3
/
4
"
11
3
/
4
"
2 @ 1
1
-
3
/
4
"
L
V
L
H E A D E R C O N S T R U C T I O N
6' MIN
N O T E
• 11-3/4" LVL HEADERS
• SILL ANCHORS 6' MINIMUM APART ON CENTER
• PRESSURE TREATED 2x SILL PLATE
• NOGGING ROUGHLY EVERY VERTICAL 4'
4'
-
0
1
/
4
"
4'
-
0
"
4'
-
0
"
1'
-
0
"
16
'
-
4
1
/
2
"
BESPOKE CONSTRUCTION, LLC
S C H N E I D E R R O B @ B E S P O K E I N . C O M
A T T :
05
P A G E O F11
R O B
VARIANCEP
R
O
J
E
C
T
3 1 7 ∙ 9 9 9 ∙ 5 5 4 1
V
E
R
S
I
O
N
1.
3
C
R
E
A
T
E
D
11
/
1
2
/
2
0
2
4
C 3
C A B I N E T C O.
PROJECT
AREA
PROJECT NO
S C H N E I D E R _ VARIANCE
F R A M I N G M E T H O D
S C A L E
N T S
8575 ZIONSVILLE RD
INDIANAPOLIS, IN 46268
L O F T A R E A
A B O V E
UP
3'-4"
3'
-
4
"
3'-4"9'-2"
3'-4"
4'-2"
F I R E P L A C E
10'-0"
52'-0"
30
'
-
5
"
5'
-
6
1
/
2
"
10'-0"
16
'
-
0
"
4'
-
2
1
/
2
"
BESPOKE CONSTRUCTION, LLC
S C H N E I D E R R O B @ B E S P O K E I N . C O M
A T T :
06
P A G E O F11
R O B
VARIANCEP
R
O
J
E
C
T
3 1 7 ∙ 9 9 9 ∙ 5 5 4 1
V
E
R
S
I
O
N
1.
3
C
R
E
A
T
E
D
11
/
1
2
/
2
0
2
4
C 3
C A B I N E T C O.
PROJECT
AREA
PROJECT NO
S C H N E I D E R _ VARIANCE
F O O T P R I N T
S C A L E
N T S
8575 ZIONSVILLE RD
INDIANAPOLIS, IN 46268
L O F T A R E A
A B O V E
UP
3'-4"
3'
-
4
"
3'-4"9'-2"
4'-0"
4'-2"
26
6
8
26
6
8
3068
12
0
1
0
0
B
A
R
N
D
O
O
R
30
3
0
30
3
0
30
3
0
F I R E P L A C E
5040 5040
5040 5040
9'
-
4
1
/
2
"
13
'
-
8
1
/
2
"
18
'
-
1
/
2
"
2'-9 3/8"9'-1 3/8"
2'-1 1/4"8'-5 1/4"
12'-9 1/4"
9
1
/
2
"
9
1
/
2
"
BESPOKE CONSTRUCTION, LLC
S C H N E I D E R R O B @ B E S P O K E I N . C O M
A T T :
07
P A G E O F11
R O B
VARIANCEP
R
O
J
E
C
T
3 1 7 ∙ 9 9 9 ∙ 5 5 4 1
V
E
R
S
I
O
N
1.
3
C
R
E
A
T
E
D
11
/
1
2
/
2
0
2
4
C 3
C A B I N E T C O.
PROJECT
AREA
PROJECT NO
S C H N E I D E R _ VARIANCE
D O O R & W I N D O W
S C A L E
N T S
8575 ZIONSVILLE RD
INDIANAPOLIS, IN 46268
1'
-
0
"
7'
-
4
"
2'-1 1/4"
8'-5 1/4"
12'-9 1/4"
27
'
-
0
"
5'-0"
4'
-
0
"
3'-0"
6'
-
1
0
"
6 21/32"
16
'
-
4
1
/
2
"
T
O
P
P
L
A
T
E
BESPOKE CONSTRUCTION, LLC
S C H N E I D E R R O B @ B E S P O K E I N . C O M
A T T :
08
P A G E O F11
R O B
VARIANCEP
R
O
J
E
C
T
3 1 7 ∙ 9 9 9 ∙ 5 5 4 1
V
E
R
S
I
O
N
1.
3
C
R
E
A
T
E
D
11
/
1
2
/
2
0
2
4
C 3
C A B I N E T C O.
PROJECT
AREA
PROJECT NO
S C H N E I D E R _ VARIANCE
E A S T E L E V A T I O N
S C A L E
N T S
8575 ZIONSVILLE RD
INDIANAPOLIS, IN 46268
9'-4 1/2"
13'-8 1/2"
18'-1/2"
9'-2 1/2"
12'-0"
10
'
-
0
"
3'-0"
3'
-
0
"
27
'
-
0
"
30'-5"
16
'
-
4
1
/
2
"
T
O
P
P
L
A
T
E
17
'
-
0
"
1'
-
0
"
BESPOKE CONSTRUCTION, LLC
S C H N E I D E R R O B @ B E S P O K E I N . C O M
A T T :
09
P A G E O F11
R O B
VARIANCEP
R
O
J
E
C
T
3 1 7 ∙ 9 9 9 ∙ 5 5 4 1
V
E
R
S
I
O
N
1.
3
C
R
E
A
T
E
D
11
/
1
2
/
2
0
2
4
C 3
C A B I N E T C O.
PROJECT
AREA
PROJECT NO
S C H N E I D E R _ VARIANCE
N O R T H E L E V A T I O N
S C A L E
N T S
8575 ZIONSVILLE RD
INDIANAPOLIS, IN 46268
2'-9 3/8"
9'-1 3/8"
52'-0"
7'
-
4
"
5'-0"
4'
-
0
"
1'
-
0
"
16
'
-
4
1
/
2
"
T
O
P
P
L
A
T
E
27
'
-
0
"
BESPOKE CONSTRUCTION, LLC
S C H N E I D E R R O B @ B E S P O K E I N . C O M
A T T :
10
P A G E O F11
R O B
VARIANCEP
R
O
J
E
C
T
3 1 7 ∙ 9 9 9 ∙ 5 5 4 1
V
E
R
S
I
O
N
1.
3
C
R
E
A
T
E
D
11
/
1
2
/
2
0
2
4
C 3
C A B I N E T C O.
PROJECT
AREA
PROJECT NO
S C H N E I D E R _ VARIANCE
W E S T E L E V A T I O N
S C A L E
N T S
8575 ZIONSVILLE RD
INDIANAPOLIS, IN 46268
30'-5"
27
'
-
0
"
16
'
-
4
1
/
2
"
T
O
P
P
L
A
T
E
1'
-
0
"
BESPOKE CONSTRUCTION, LLC
S C H N E I D E R R O B @ B E S P O K E I N . C O M
A T T :
11
P A G E O F11
R O B
VARIANCEP
R
O
J
E
C
T
3 1 7 ∙ 9 9 9 ∙ 5 5 4 1
V
E
R
S
I
O
N
1.
3
C
R
E
A
T
E
D
11
/
1
2
/
2
0
2
4
C 3
C A B I N E T C O.
PROJECT
AREA
PROJECT NO
S C H N E I D E R _ VARIANCE
S O U T H E L E V A T I O N
S C A L E
N T S
8575 ZIONSVILLE RD
INDIANAPOLIS, IN 46268
Page 8 of 12 File: Hearing Officer Development Standards Variance Handout 2024[9].docx Revised: 12-18-23
FINDINGS OF FACT SHEET - DEVELOPMENT STANDARDS VARIANCE
CARMEL ADVISORY BOARD OF ZONING APPEALS
(Petitioner to fill out 1-3 + first two blanks)
Docket No.: _______________________________________________
Petitioner: _______________________________________________
1.The approval of this variance will not be injurious to the public health, safety, morals and general welfare of the
community because:
_____________________________________________________________________________________
_____________________________________________________________________________________
_____________________________________________________________________________________
2.The use and value of the area adjacent to the property included in the variance will not be affected in a substantially
adverse manner because:
_____________________________________________________________________________________
_____________________________________________________________________________________
_____________________________________________________________________________________
3.The strict application of the terms of the Unified Development to the property will result in practical difficulties in the
use of the property because:
_____________________________________________________________________________________
_____________________________________________________________________________________
_______________________________________________________________
______________________
DECISION
IT IS THEREFORE the decision of the Carmel Board of Zoning Appeals that Development Standards Variance Docket No.
___________________________ is granted, subject to any conditions stated in the minutes of this Board, which are
incorporated herein by reference and made a part hereof.
Adopted this _______________ day of __________________________________, 20 _______.
_____________________________________________ _____________________________________________
HEARING OFFICER, Carmel Board of Zoning Appeals
_____________________________________________ _____________________________________________
SECRETARY, Carmel Board of Zoning Appeals
Conditions of approval of the Board, if any, are listed on the Letter of Grant.
PZlOrODlrrOnO V
hndrew E ,aurie Uchneider
Hhe proposed use will not cause pollutionO unsanitary conditionsO traffic congestion or
impair drainageB
Hhe barn and landscaping will enhance the appearance and value of the propertyB
furthermoreO it will not impair any clear sight lines in any wayB
vue to the size of structures in close proximityO without reliefO the owners will be unable to
enhance the appearance and value of the property for themselves and their neighborsB
bn additionO the current structure will be in violation unless relief is givenB Currently the setbacks are
none existent and we are proposing 5', per guidelines. The increased area for the barn footprint
will give enough storage and space to use the barn to its full potential, where currently, there are
structural defects with the existing structure.
gZYGZGoYZZGNG V
Page 8 of 12 File: Hearing Officer Development Standards Variance Handout 2024[9].docx Revised: 12-18-23
FINDINGS OF FACT SHEET - DEVELOPMENT STANDARDS VARIANCE
CARMEL ADVISORY BOARD OF ZONING APPEALS
(Petitioner to fill out 1-3 + first two blanks)
Docket No.: _______________________________________________
Petitioner: _______________________________________________
1.The approval of this variance will not be injurious to the public health, safety, morals and general welfare of the
community because:
_____________________________________________________________________________________
_____________________________________________________________________________________
_____________________________________________________________________________________
2.The use and value of the area adjacent to the property included in the variance will not be affected in a substantially
adverse manner because:
_____________________________________________________________________________________
_____________________________________________________________________________________
_____________________________________________________________________________________
3.The strict application of the terms of the Unified Development to the property will result in practical difficulties in the
use of the property because:
_____________________________________________________________________________________
DECISION
IT IS THEREFORE the decision of the Carmel Board of Zoning Appeals that Development Standards Variance Docket No.
___________________________ is granted, subject to any conditions stated in the minutes of this Board, which are
incorporated herein by reference and made a part hereof.
Adopted this _______________ day of __________________________________, 20 _______.
_____________________________________________ _____________________________________________
HEARING OFFICER, Carmel Board of Zoning Appeals
_____________________________________________ _____________________________________________
SECRETARY, Carmel Board of Zoning Appeals
Conditions of approval of the Board, if any, are listed on the Letter of Grant.
9ndrew 8 Laurie Schneider
Hhe proposed use will not cause pollutionO unsanitary conditionsO traffic congestion or
impair drainageB
Hhe barn and landscaping will enhance the appearance and value of the propertyB
furthermoreO it will not impair any clear sight lines in any wayB
vue to the size of structures in close proximityO without reliefO the owners will be unable to maximize the
storage space of the new barn construction. The current UDO only gives 18' in height. In order to
maximize space, and storage capacity, there is a second floor over 1/3 of the barn. This will also mean
that items will be able to be stored on the upper level, leaving usable space on th lower level for
entertainment/games during periods of weather.
gZYGZGoYZZGNP V
gZYGZGoYZZGNP V