Loading...
HomeMy WebLinkAbout07040193 State Release Would you like to reduce your turnaround time? ELECTRONICALLY FILE YOUR PROJECT WITH STATE OF INDIANA AT eflle24~?@dhs..in,gov. Or VISIT OUR WEB SITE AT www.in.gov/dhs/branches/planrevlew/index.html Project number Release date Indiana Department of Homeland Security DIVISION OF FIRE SAFETY 1 PLAN REVIEW 402 W. Washington St., Room E245 Indianapolis, IN 46204 INDIANA 02 ~oo~.Q.QyOO Scope of release ARCH ELEC FDN PLUM STR Type of release Standard Project name Monon and Main Building No. 16 TOWNHOUSE CONSTRUCTION DESIGN RELEASE State Farm 41191 (R9/S-98) JIo Report Printed on: April 17, 2007 325274 Construction type V-B MECH To: Owner J Architect I Engineer Bruce Gunstra Builders Inc Robert Grove 18369 8383 Craig Street NO 100 Indianapolis IN 46250 Available AI. Your LOCII L.icence Branch SUPPORT HOOSIER SAFETY Street address 25, 33, 41 and 49 Florence Street ax & e-mail: 3175952161.smosher@gunstrabullders.com The plans, specifications and application submitted for the above referenced project have been reviewed for compliance with the applicable rules of the Fire Prevention and Building Safety Commission. The project is released for construction subject to, but not necessarily limited to, the conditions t1$ted'below;~"fHtS-IS"NOTA' BtJltDING' PERMIT;AfI'reQuirecrlocal'permits'and~licenses- mustbe'obtained prior-to'beginning'constfuction work. All construction work must be in full compliance with all applicable State rules. Any changes In' the released plans and/or specifications'lmust be filed with ~nd released by this Office before any woi'~ i~1}~He~Eld.\Thi~rel~fj3se P_~y b~,;;>usp~ndag',i:?r revoked If it is determif"'l,ed\~~ I?_~'iss_yed inierror, in violation Of any rules of the Commission or if it Is b~~eI!6!1 i~,}:o,vect ~r ir.:suW~i~rt infon,,~tion_;~Thi~ release shalt expire by,timltation,}i1lfld become nutl and void, if the work authorized is not commenced~wit1:lin oJleJt)iye~r ~~mthe abovedatf:h- , 'i~ :: _,_.~4 : CONDITIONS: .<' .-, ,"';J .;,",-,,'r .,-,', '." ,~;,'- :. '"", it ;>.';;~"':! - City CARMEL County HAMILTON i _ ',. ~ote :(A 1 A & A 1 B): In accorA~~9~i~~JjJhe affidavits~m under p~naltie~. of perjury _in tJ:le apptic?~qnf9r constructl.o~ ,des.ign releas~ the plans and specifications filed in conl~n~tic;ift!'v'!i~~, this. projeCt,shall comply with all of the applicable rules and lawS of Fire Preventicm and Building Safety <,?ommission. Providing fa}s~~IDJ~~clil.o~ constitut~:~~ act of pe~ury, which is a-Class 0 fel~y p~nishable.by a prison terin'and a fine up to $10,000: In accordance with Sectlon .1,9,'of t~eGeneral Adminfstrative Rul,es (675 lAC 12~6-19) a complete set of plans and specifications that conform ~xactly to the desig,n~~,irt'-~a,s.,relE!ase~'by the office of the statebuitding commissioner shall be maintained'on the construction jobsite as well as a copy of the design:n3Iease:' ':.r. )~:'~;:;:07;':>:,L::)j~,_,,:/ __:._-,~: __ "', "'. . . /li;,lIb!~P,foject h,as been reviewed under the 2005 Indiana Residential Code. t:',::--':i4"-n''-;;. .- ~<,~."" - '-"'- . ,. . '.';{~:tO)NrlhOUSe is a single,f~rriilY dwelling unit constructed in a group of three or more attached units . /\'separated by property liries in which each unit extends from foundation to roof and with open space ./:.'on at least two sides in accordance with Section R202, IRC (675 lAC 14-4,3). : ...i'",,/ Townhouse common walls'shall be. continuous from the foundation to the underside iJf the roof sheathing, d~ck orsiab; aDd shall extend the full length of the common wall in accordance with ... .~!,~i()D_3.1L?o 1.,IR,CJ!3!.?!!'Y.!41.3), . The minimum snow loading for roof design shall be in accordance with Section R301, IRC (675 lAC 14-4.3), Appliances having an ignition source shall be elevated such that the source of ignition is not less than 18 inches above the floor in garages and in rooms or spaces that area not part of the living space that communicate with the garage in accordance with Section M1537,31RC (675 lAC 14-4.3). An attic access opening of at least 22 inches by 30 inches shall be provided for attics that exceed 30 square feet and have a clear height of 30 inches or more in accordance with Section R807, IRC (675 lAC 14-4.3). Please be advIsed that jf an administrative review of this action is desired, a written petition for review must be filed at the above address with the Fire Prevention and Building Safety Commission identifying the matter for which a review is sought no later than eighteen (1 B) days from the above ~ stated date, unless the eighteenth day falls on a Saturday, a Sunday, a legal holiday under State statute, or a day in which the Department of Fire and Building Services is closed during normal business hours. In the latter case, the filing deadline will be tne firsl working day thereafter. If you choose to petition, and the before-mentioned procedures are followed, your petition for review will be granted, and an administrative proceeding will . be conducted by an administrative law judge of the Fire Prevention and Building Safety Commission. If a petition for review is not filed, this Order will be final, and you must comply with its requirements. ,,0; " ~<i" Page 1/2 Filed By Code review official Code Enforcement & Plan Review Branch Director TONY BRADSHAW ~~d/S~ Address (name, title of local officiaJ,street,city,state and ZIP code DEPT OF COMMUNITY SERVICE State Fire Marshal War 0 ~ JIM BLANCHARD ONE CIVIC SQUARE CARMEL, IN 46032 Fax & e-mail: 3175712499 iblanchardfti)carmef.in,nov Would you like to reduce your turnaround time? ELECTRONICALLY FILE YOUR PROJECT WITH STATE OF INDIANA AT efile24-7@dhs..in.gov, Or VISIT OUR WEB SITE AT www,in.gov/dhs/branches/plan review/index.hlml i~ .~ "i.i ~~ ~ -,~ ~ .'~; Page 2/2