HomeMy WebLinkAbout07050210 Site Plan
.~~
The Schneider Corporation
8901 otis A"enue
Blat.orle Fort Barriaon
IndiaIl4poliJ, IndiaI14 46216-1037
317-826-7100
Scmeider 317-826-~1 FAX
This Plot Plan Prepared For: R.H. of Indiana
Lot # 229 , containing 11,200 S.F.:!:, in
Cla)boume
Section # 3
INSlR. # 200400080247
P.C. # 3. Slide # 533
HamBten County. Clay Twp
Sec 30. 11 BN. ROOE
13438 Salamone Way
Carmel, IN 46074
Prepared Date: 05/18/07: By: AMA
Proposed Bu)'lll'(s): Oavid Picheng Huang
11 I~
ED,In"riDa
3uneyIDs
Londooope Arcllitecbue
GIlI'1llI
GeololY
Note:
This drawing is based on construction pIons or Irecord
drawings, and is not bosed upon 0 field survey. i The
Schneider Corporation does not warrant the accuracy or
sufficiency of this information. Contractors should verify
existing conditions prior to any construction. Any
discreponcy found on this drowing should be reported to
The Schneider Corporation immediately; foiling to do so
results in the contractors assumption of all liability.
Plot Plan Legend
( 50' R/W)
~ Proposed Grodes
000.0 Existing Grades
__000.0- Contour Grode
* Approx. Lateral location
- . - Sanitary Sewer lines
-sr- Storm Sewer Unes
- '" - Water Service Unes
- - - - - - - Sub-Surface Drain lines
. Manh.e (Sanitary or Storm)
. Beehive Inlet (Staon)
iIII Curb Inlet (Storm)
D End Section (Storm)
A Fire Hydrant
- b.. _ ..0 _ Flow Une of swale
Bunding line (Bt / BSL)
- - - - - - - Easement line
Note:
The basement elevotlon, depicted hereon, has been determined and
based on the pad grades ond/Of' contours taken from the construction
plans for this ~bdivi!ion, Unless stated, no information about
fluctuating water tables, soD conditions, or soH t}1)e!l has been
provided or stated on soid plans, This lot Is located near 0 body of
water, Lot or soR conditions moy require that the basement floor
elevation be held 2 foot above. normal pool eleWltioo. Site.investigation
moy be needed If water Is encountered during the excavation process
Of' if other knOWll water elevation or soils conditions are present
Investi9lJtion and any remedial procedures is at the discretion of the
buDder to determine and toke appropriate steps of action. If any
ground water Is encountered during excavation the bunder Is
encouraged to contact The Schneider Corporation to discuss possible
courses of action.
Note: Sump pump(s) to be
ploced by builder os needed.
Community Restrictions:
Side Yard = 5'
Rear Yard = 20'
Aggregate = 10' (B.H.)
Zoning = S1
R.H. of Indiono
Finished Floor Elevation Information
Pod Grode = 912.0 per pion
Pod Grode + 0.7' = Garoge FIT (912.7)
Gorage FFE + 1.5' = Residentiol FFE (914.2)
Residentiol FFE - 9.0' = Bosement FFE (905.2)
Note: The garage finished floor elevation
is 2.7' above the curb at the drive, per plan.
Ground Cover Calculations:
Drive = 797 SFi
Public Wolk = 319 SF i
Privote Wolk = B8 SF i
Hydroseeding =5,110 SFi
Sod = 310 Sri, from
Rear of residence.
Optionol Sod Pockoge
Hydroseeding =BOO SFi
Add!. Sod Pkg.= 479 Sri, to
Rear easement.
Sidewalk to be placed
l' from property line,
4' from bock of curb,
per plan,
FLOOD HAZARD STATEMENT
CERnFICA nON
Note: Sanitary Sewer
Tap of Casting Information
Upstreom Monhole, Te= 912.21
Downstream Manhole, TC= 910.51
per record drowing Lot # 229
~07.0074070
Deton of Ground/ Storm
Water flow pattern for
individual lots.
o
~
=~=
o
TYPICAL SWALE SECTION
Assumed North
Scale : ,. = 3G'
Note: Sunder to ensure positive
drainage away from structure(s).
Note:
The contractor is to maintain 0 minimum
distance of ten feet (10') between the
sanitary sewer and water line laterals.
/"
iSTR f 82
,TC=92.21
PER RECORD
ORA\\lNG
,\\\\\\\\\\111111/111/1////
#~\'\~ l. C;/J~
~ ~ ..,........ /('&~
ff ~....~G\SNTt:~~.......,.....o%
~c:::::."'<(- 0 O.......o~
, ( 50303 ) -.
- . ~
~ . STATE OF ./ f&
~<;;>:'^,O'A~!:,....~t
~7/J?} """"""'t'.,,'-l~
%/J/JJ. SUR'4 ".\\\~#
'"1/11/1/11111111\\\\\\\\
~, l ~ f~9foW
. \..;---. . PER RECORD
DRA\\lNG
This drawing is not In ended to be represented as a retracement or
original boundary survey, a route survey, or a Surveyor Location Report.
c
-.;.
15-
SGNA TURE :
DATE:
Note: Per Carmel zoning ordinance 26.1,1 : The
residentiol district limits height to twenty-five feet
(25'), however a dwelling may be increased in
height to thirty-five feet (35') provided the side
and rear yards are increased on odditional one
foot (1') for each one foot (1') the structure
exceeds the first twenty-five feet (25') in height.
SGNA TURE REPRESENTS CON~RMA TION OF RECEIPT OF PlOT PlAN BY CUSTOt.IER.