Loading...
HomeMy WebLinkAbout07050210 Site Plan .~~ The Schneider Corporation 8901 otis A"enue Blat.orle Fort Barriaon IndiaIl4poliJ, IndiaI14 46216-1037 317-826-7100 Scmeider 317-826-~1 FAX This Plot Plan Prepared For: R.H. of Indiana Lot # 229 , containing 11,200 S.F.:!:, in Cla)boume Section # 3 INSlR. # 200400080247 P.C. # 3. Slide # 533 HamBten County. Clay Twp Sec 30. 11 BN. ROOE 13438 Salamone Way Carmel, IN 46074 Prepared Date: 05/18/07: By: AMA Proposed Bu)'lll'(s): Oavid Picheng Huang 11 I~ ED,In"riDa 3uneyIDs Londooope Arcllitecbue GIlI'1llI GeololY Note: This drawing is based on construction pIons or Irecord drawings, and is not bosed upon 0 field survey. i The Schneider Corporation does not warrant the accuracy or sufficiency of this information. Contractors should verify existing conditions prior to any construction. Any discreponcy found on this drowing should be reported to The Schneider Corporation immediately; foiling to do so results in the contractors assumption of all liability. Plot Plan Legend ( 50' R/W) ~ Proposed Grodes 000.0 Existing Grades __000.0- Contour Grode * Approx. Lateral location - . - Sanitary Sewer lines -sr- Storm Sewer Unes - '" - Water Service Unes - - - - - - - Sub-Surface Drain lines . Manh.e (Sanitary or Storm) . Beehive Inlet (Staon) iIII Curb Inlet (Storm) D End Section (Storm) A Fire Hydrant - b.. _ ..0 _ Flow Une of swale Bunding line (Bt / BSL) - - - - - - - Easement line Note: The basement elevotlon, depicted hereon, has been determined and based on the pad grades ond/Of' contours taken from the construction plans for this ~bdivi!ion, Unless stated, no information about fluctuating water tables, soD conditions, or soH t}1)e!l has been provided or stated on soid plans, This lot Is located near 0 body of water, Lot or soR conditions moy require that the basement floor elevation be held 2 foot above. normal pool eleWltioo. Site.investigation moy be needed If water Is encountered during the excavation process Of' if other knOWll water elevation or soils conditions are present Investi9lJtion and any remedial procedures is at the discretion of the buDder to determine and toke appropriate steps of action. If any ground water Is encountered during excavation the bunder Is encouraged to contact The Schneider Corporation to discuss possible courses of action. Note: Sump pump(s) to be ploced by builder os needed. Community Restrictions: Side Yard = 5' Rear Yard = 20' Aggregate = 10' (B.H.) Zoning = S1 R.H. of Indiono Finished Floor Elevation Information Pod Grode = 912.0 per pion Pod Grode + 0.7' = Garoge FIT (912.7) Gorage FFE + 1.5' = Residentiol FFE (914.2) Residentiol FFE - 9.0' = Bosement FFE (905.2) Note: The garage finished floor elevation is 2.7' above the curb at the drive, per plan. Ground Cover Calculations: Drive = 797 SFi Public Wolk = 319 SF i Privote Wolk = B8 SF i Hydroseeding =5,110 SFi Sod = 310 Sri, from Rear of residence. Optionol Sod Pockoge Hydroseeding =BOO SFi Add!. Sod Pkg.= 479 Sri, to Rear easement. Sidewalk to be placed l' from property line, 4' from bock of curb, per plan, FLOOD HAZARD STATEMENT CERnFICA nON Note: Sanitary Sewer Tap of Casting Information Upstreom Monhole, Te= 912.21 Downstream Manhole, TC= 910.51 per record drowing Lot # 229 ~07.0074070 Deton of Ground/ Storm Water flow pattern for individual lots. o ~ =~= o TYPICAL SWALE SECTION Assumed North Scale : ,. = 3G' Note: Sunder to ensure positive drainage away from structure(s). Note: The contractor is to maintain 0 minimum distance of ten feet (10') between the sanitary sewer and water line laterals. /" iSTR f 82 ,TC=92.21 PER RECORD ORA\\lNG ,\\\\\\\\\\111111/111/1//// #~\'\~ l. C;/J~ ~ ~ ..,........ /('&~ ff ~....~G\SNTt:~~.......,.....o% ~c:::::."'<(- 0 O.......o~ , ( 50303 ) -. - . ~ ~ . STATE OF ./ f& ~<;;>:'^,O'A~!:,....~t ~7/J?} """"""'t'.,,'-l~ %/J/JJ. SUR'4 ".\\\~# '"1/11/1/11111111\\\\\\\\ ~, l ~ f~9foW . \..;---. . PER RECORD DRA\\lNG This drawing is not In ended to be represented as a retracement or original boundary survey, a route survey, or a Surveyor Location Report. c -.;. 15- SGNA TURE : DATE: Note: Per Carmel zoning ordinance 26.1,1 : The residentiol district limits height to twenty-five feet (25'), however a dwelling may be increased in height to thirty-five feet (35') provided the side and rear yards are increased on odditional one foot (1') for each one foot (1') the structure exceeds the first twenty-five feet (25') in height. SGNA TURE REPRESENTS CON~RMA TION OF RECEIPT OF PlOT PlAN BY CUSTOt.IER.