Loading...
HomeMy WebLinkAboutGenerator A-101GEN_0923_20070604Seal Project No. Drawing No. Date Scale Drawing Title No. REVISIONS/SUBMISSIONS Date B C D E F G H J K L 2 P Q R M N 3 4 5 6 7 8 9 10 11 12 13 14 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 A A B C D L K J H G F E N M 6/4/2007 CAD FILE: A-101GEN_0923-000.dgn $DGNLEV$ $TBLNAME$ drowe 15 16 17 18 P Q R 1 c TVS INTERIORS, INC. TVS INTERIORS, INC. This drawing is the property of TVS INTERIORS, INC. and is not to be reproduced or copied in whole or in part. It is only to be used for the project and site specifically identified herein and is not to be used on any other project. It is to be returned upon request. 2700 PROMENADE TWO, 1230 PEACHTREE STREET N.E. ATLANTA, GEORGIA 30309-3591 T 404-888-6600 F 404-888-6700 Scales as stated hereon are valid on the original drawing, the dimensions of which are 30x45 inches. These scales noted hereon are hereby changed by the ratio of the overall sheet dimensions of the print to the corresponding dimensions of the original drawing. Drawing Title 05.25.2007 1 Capital Group Companies 12911 NORTH MERIDIAN STREET OPUS LANDMARK AT MERIDIAN - BUILDING ONE CARMEL, INDIANA 46032 INDIANAPOLIS EXPANSION TVS: 0923-000 CG #139811 NOTES NOT RELEASED FOR CONSTRUCTION 00.00.2007 RELEASED FOR REVIEW 06.01.2007 A,1 F,1 A,8 1/8" = 1’-0" 1/4" = 1’-0" A-101GEN F,8 1/4" = 1’-0" L,8 ELEVATION AT REAR OF GENERATOR BUILDING FLOOR PLAN OF GENERATOR BUILDING 1/8" = 1’-0" 1/4" = 1’-0" ROOF PLAN OF GENERATOR BUILDING ELEVATION AT FRONT OF GENERATOR BUILDING ELEVATION AT SIDES OF GENERATOR BUILDING A-101GEN A-101GEN A-101GEN A-101GEN A,8 L,8 L,8 F,8 OPPOSITE HAND 1. GENERATOR AND GENEREATOR ENCLOSURE, 50’ W X 12’ D X 19’ H. 3. 12" THICK CMU. COLOR TO MATCH PRECAST PANELS OF EXISTING BUILDING, CONTRACTOR TO COORDINATE AND SUBMIT SAMPLE FOR APPROVAL. 4. 12" THICK SPLIT-FACE CMU. COLOR TO MATCH EXPOSED AGGREGATE PRECAST PANELS OF EXISTING BUILDING, CONTRACTOR TO COORDINATE AND SUBMIT SAMPLE FOR APPROVAL. 5. 12" THICK SMOOTH-FACE CMU. COLOR TO MATCH SANDBLASTED PRECAST PANELS OF EXISTING BUILDING, CONTRACTOR TO COORDINATE AND SUBMIT SAMPLE FOR APPROVAL. 6. ARCHITECTURAL PRECAST PARAPET CAP. COLOR TO MATCH SANDBLASTED PRECAST PANELS OF EXISTING BUILDING, CONTRACTOR TO COORDINATE AND SUBMIT SAMPLE FOR APPROVAL. 7. CONCRETE PAD TO BE DESIGNED BY STRUCTURAL ENGINEER BASED ON GENERATOR MANUFACTURES REQUIREMENTS. 9. BALLASTED SINGLE-PLY EPMD MEMBRANE ROOF TO MATCH EXISTING BUILDING ROOF. 2. REMOVABLE METAL LOUVER. PAINT TO MATCH SLPIT-FACE CMU, CONTRACTOR TO COORDINATE AND SUBMIT SAMPLE FOR APPROVAL. 8. 4’-0" PAIR HOLLOW METAL DOORS. LOCKABLE HARDWARE SET TO BE VANDAL RESISTANT. PAINT TO MATCH SPLIT-FACE CMU. CONTRACTOR TO COORDINATE AND SUBMIT AMPLE FOR APPROVAL. 10. COMMERCIAL GRADE GUTTER AND DOWN SPOUT. COLOR TO MATCH SPLIT-FACE CMU. CONTRACTOR TO COORDINATE AND SUBMIT SAMPLE FOR APPROVAL. 11. CONCRETE SLASH BLOCK. 8’-4" 5’-8" 6’-4" 6’-4" 62’-8" 26’-0" EQ 8’-0" 8’-0" EQ 12. CONTROL JOINT. SLOPE SLOPE SLOPE 24’-8" 9’-4" 7’-8" 8’-0" 8’-0" 7’-8" 1" 1" 2’-4" 2’-4" 2’-4" 2’-4" 2’-4" 2’-4" 8" EQ n EQ n 8" n 24’-8" 1" 1" NOTE: 1 NOTE: 3 NOTE: 2 NOTE: 8 NOTE: 10 NOTE: 9 NOTE: 6 NOTE: 10 NOTE: 6 NOTE: 4 NOTE: 7 NOTE: 5 NOTE: 5 NOTE: 11 NOTE: 5 NOTE: 5 NOTE: 12 7’-8" 8’-0" 8’-0" 7’-8" NOTE: 6 NOTE: 5 NOTE: 5 NOTE: 4 NOTE: 5 NOTE: 12 NOTE: 5 NOTE: 7 NOTE: 6 NOTE: 5 NOTE: 5 NOTE: 4 NOTE: 5 NOTE: 12 NOTE: 5 NOTE: 7 19’-4" COORDINATE WITH FINAL SIZE OF GENERATOR NOTE: 6 BEYOND EQ 16’-0" COORDINATE WITH FINAL SIZE OF GENERATOR EQ NOTE: 13 EQ EQ n NOTE: 14 NOTE: 7 14. EXISITNG PARKING STALL. NOTE: SEE CIVIL DRAWINGS FOR SITE INFORMATION. GENERATOR BUILDING PLANS AND ELEVATIONS NOTE: 11 NOTE: 10 ACOUSTICAL PERFORMANCE "The generator enclosure has been specified to achieve a noise level of no more than 65 dB(A) when measured from any face, end, side, opening, etc. This includes ventilation intake and discharge paths, as well as hot gas exhaust. The generator is proposed to locate facing Highway 31, 15’ from the property line to the adjacent hotel, currently a Hilton Garden Inn, at 13090 N. Pennsylvania Avenue. The generator enclosure will sit inside a split face concrete block building which is provided with a pair of double doors, as well as intake and exhaust louvers on the ends. The city of Carmel Indiana code item 6-158 cites Noise Regulations and requires that the following is prohibited: noise that is audible at 40 feet or more from its source or is at 90 decibels or more measured not less than 6 feet from its source. With the manufacturer’s enclosure and concrete building, generator operation should be within 50 dB(A) at 40 feet - likely inaudible over noise from typical traffic flow on Highway 31. It will also be less than 90 decibels when measured within 6 feet. We project noise levels of 55 to 60 dB(A) at the property line during generator operation, due to marginal attenuation provided by distance and the enclosure. This should be at or below existing daytime ambient due to traffic noise from Highway 31. Considering the hotel guest rooms, located 100’+ from the generator, we project approximately 40 dB(A) as measured inside an open window, which should be at or below HVAC system noise and non-intrusive to guests." 11’-8" n NOTE: 8 13. DECORATIVE STEEL BOLLARDS WITH DOWN LIGHTS. CONTRACTOR TO COORDINATE AND SUBMIT SAMPLE FOR APPROVAL.