HomeMy WebLinkAbout07050168 Lighting Compliance Cert
"
COMcheck Software Version 3.3.1
Lighting Compliance Certificate
90.1 ('89) Code
Report Date: 04/03/07
Data filename: E:\2007 Jobs\0701 9\Energy Code\07019A.cck
Section 1: Project Information
Project Title: limited Too -Clay Terrace
Construction Site:
14390 Clay Terrace BLVD.
Carmel. IN 46032
Owner/Agent:
Tween Brands
8323 Walton Parkway
New Albany, OH 43054
Designer/Contractor:
HBK Consultants
171 Charring Cross Drive South
Westerville, OH 43081
Section 2: General Information
Building Use Description by:
Project Type:
Activity Type
New Construction
Activity Tvoe(s)
Retail Sales, Wholesale Showroom
Corridor, Restroom, Support Area
Floor Area
3169
811
Section 3: Requirements Checklist
Interior Lighting:
o 1. Total actual watts must be less than or equal to total allowed watts,
Allowed Watts Actual Watts Complies
10473 10089 YES
Exterior Lighting:
o 2. Comply with Sections 401.3.1 and 401.3.1.1 of 90.1-1989 Code and attach documentation.
Controls, Switching, and Wiring:
o 3. Master switch at entry to hotel/motel guest room.
o 4. Minimum of one manual control for each space with no task activity (i.e, storage). Multiple manual controls, occupancy sensor,
automatic timer, or dimmer in other spaces.
Exceptions:
Lighting for emergency or exit egress or intended for continuous operation.
o 5. Photocell/astronomical time switch on exterior lights.
Exceptions:
Lighting intended for 24 hour use.
o 6. Tandem wired one-lamp and three-lamp ballasted luminaires (No single-lamp ballasts).
Exceptions:
Luminaires with three lamp ballasts (or electronic high-frequency single-lamp ballasts).
Section 4: Compliance Statement
Compliance Statement: The proposed lighting design represented In this document is consistent with the building plans, specifications
and other calculations submitted with this permit application. The proposed lighting system has been designed to meet the 90.1 ('89)
Code requirements in COMcheck Version 3.3.1 and to comply with the mandatory requirements in the Requirements Checklist.
Page 1 of 3
W/L t-/A.#2 'J)~/?F~-;;:"
~e
1"'"''''''''''''''''''''
.,." 1\' ....
./,". ,.)1>-,111 D. S """'"
/-i~::~:Gi'S'T(A;~~~'\
~ Pi: 1 S3G02f:1i i ~
~ ;.?~ '. SlAT=- fiF r:r: i
\. "'0 \. / '- ... ./ I~ j
-:;. -A".(\. .... 1V'f) I iJ. \'~?-.... "'..;!.; ,~
'~" ~ '_0 ....".:..::..~...,... t""";;;' _-,...
" uS ,,\\"\ .,'"
""" IO"J ^ L 'C\'<>-- ,...,
....,.....":..,::~,,............,.
fi/-dZ ~~ tf-J-#7
Signature Date '
,
COMcheck Software Version 3.3.1
Lighting Application Worksheet
90.1 ('89) Code
Report Date:
Data filename: E:\2007 Jobs\07019\Energy Code\07019A.cck
Section 1: Allowed Lighting Power Calculation
A
Area Category
B
Floor Area
(ft2)
3169
811
Retail Sales, Wholesale Showroom
Corridor, Restroom, Support Area
Section 2: Actual Lighting Power Calculation
A
Fixture 10 : Description I Lamp I Wattage Per Lamp I Ballast
Compact Fluorescent 1: B: Recessed Downlight I Triple 4-pin 26W I Electronic
Incandescent 1: C: Track Head I Incandescent SOW
Incandescent 3: G: Pendant I Incandescent 1 DOW
Linear Fluorescent 1: 2 x 2: Recessed Fluorescent! 24" TaU 32W I Electronic
Linear Fluorescent 2: 1 x 4: Fluorescent Strip /48" T8 32W I Electronic
C
Allowed
Watts I ft2
3.1
0.8
Total Allowed Watts =
o
Allowed Watts
(BxC)
9824
649
10473
B C 0 E
Lamps! #01 Fixture (CXD)
Fixture Fixtures Watt.
2 19 52 988
1 116 50 5800
3 1 300 300
2 23 71 1633
1 36 38 1368
Total Actual Watts:::: 10089
Section 3: Compliance Calculation
If the Total Allowed Watts minus the Total Actual Watts is greater than or equal to zero, the building complies.
Total Allowed Watts::::
Total Actual Watts ::::
Project Compliance ::::
10473
10089
384
Page 3 of 3