HomeMy WebLinkAbout07050266 Site Plan
~~
The Schneider CorporaUon
8901 0t1I Avenue
Historic Fon Harr1son
Indianapolb. Indiana 46216-1037
317-ll2ll-7100
317-626-7200 fAX
Rn&ineerIna
SUrToytng
Landscape ArclUtectut1l
GIS .1lS
GeololY
This Plot Plan Prepared For. R.H. of Indiana
Lot #223 , containing 14,037 S.F.:!:. in
Cla)boume
Section # 3
INSlR. # 200400080247
P.C. # 3, Slide # 533
HamDton County, Clay Twp
Sec 30, TIaN, R03E
13451 Salamone Way
Carmel, IN 46074
Prepared Date: 05/18/07: By. AMA
Proposed Buyer(s}: INVENTORY
Plot Plan Legend
( 50'RjW)
[]QQ;[] Proposed Grodes
000.0 Existing Grades
_000.0- Contour Grade
* Approx. Lateral Location
- . - Sanitary Sewer lines
-IT- Storm Sewer Unes
- I,J - Water Ser'Yice lines
- - - - - - - Sub-Surface Drain lines
. Manhole (Sanitary Of Storm)
. Beehive Inlet (Storm)
11II Curb Inlet (Storm)
D End Section (Storm)
.A Fire Hydrant
- 000 - 000 - Flow line of s.ole
Building Line (BL / BSL)
- - - - - - - Easement line
Community Restrictions:
Side Yard = 5'
Rear Yard = 20'
Aggregate = 10' (B.H.)
~zoning: SI",
~
'0
4: ()p .).. . .,.oret
TYPICAL SWALE SECl10N
SIR # E81
TC=910.51
PER RECORO
ORA\\lNG
./
Sidewalk to be placed
l' trom property line,
4' from back of curb,
per plan.
R,H. of Indiana
Finished Floor Elevation Information
Pod Grode = 912.4 per plan
Pod Grode + 0.7' = Garage FIT (913.1 )
Garage FFE + 1.5' = Residential FFE (gl4.6)
Residential FFE - 9.0' = Basement FFE (905.6)
Note: The garage finished floor elevation
is 2.8' above the curb at the drive, per plan.
FLOOD HAZARD STATEMENT
CERTlFICA TlON
~",,\\\\\lIlIIIIIII"IIIII//
,ii;"'-' (: L /> //~
;i>.::" \:" . o;Li//1'
~ ",.:~' .........".. /r(/./J~
~ ~ .....(;\5 H:J?';;... 0/' A'"
;:$ . ~ N '0' /'-'::::::::
:::::' ~ ..'~ 0 ". "o~
~ -.....,.... ..... %
- . . Ground Cover Calculations:
i : S0303 j I Drive = 941 SF,
- - ~~_=m ~
~ '. STATE OF ..... & Private Walk =9 SF:!:
~<"" I ....~ i;j
~ ...("';....';10/ A~."::... ~~~ Hydroseeding =7,059 SF:!:
% /f'J .S....U..o.,\ \. ~ if Sod = 485 SYf, from
~/I' l\'1 ,\~~
11//III/1/IIIJlIlI\\\\\\\\\\'" Rear of residence.
Optional Sod Package
~ H)<Jraseedlng =2,555 SF,
~, l Add!. Sod Pkg.= 500 SYf, to
- \ .-J-- aptlonal sod line
This drawing IS not ',n ended to be represented os 0 retrocement or
original boundary survey, a route survey, or a Surveyor Location Report.
Note:
This drawing is based on construction pIons or ~ecord
drawings, and is not based upon a field survey.l The
Schneider Corporation does nat warrant the acciJracy or
sufficiency of this information. Contractors should verify
existing conditions prior to any construction. Any
discrepancy found on this drawing should be reported to
The Schneider Corporation immediately; faaing to do so
results in the contractors assumption of 011 liability.
Note:
The bQsement elevotion. depleted hereon, has been determined and
based on the pod grades and/or contours token trom the construction
plans for this subdl'otsion. Unless stated, no information about
fluctuating water tables, soa conditions, or soH t)pes has been
pro'o'ided or stated on sold plans. This lot is located near a body of
water. lot 0( soU conditions may require that the basement floor
elevation be held 2 foot above normal pool ele'otltloo. Site investigation
may be needed If water Is encountered during the excavation process
or 1t other known water ele'otltlon or soBs conditions ore present
Investigation and any remedial procedures is at the discretloo of the
bunder to determIne and take appropriate steps of action. 'If any
ground water Is encountered during excavation the buader Is
encouraged to contact The Schneider Corporation to discuss possible
courses of action.
Note: Sump pump(s) to be
placed by bunder as needed.
Lot # 223
Vb07.0074069
~
~
=~=
Detan of Ground/ Storm
Water flow pattern for
individual lots.
Note: Sunder to ensure positive
drainage away from structure{s;
Note:
The contractor is to maintain 0 minimum
distance of ten feet (10') between the
sanitary sewer and water line laterals.
/'
/'
'*'
o
~\)
~\~.
Flood Hazard Statement: The accuracy of any flood hazard data shown on this report is subject to
map scale uncertainty and to any other uncertainty in location or elevation on the referenced flood
insurance rate map. ALL of the within described land DOES NOT lie within that special flood hazard
zone AE as said land plots by scale on flood insurance rate map #18057C 0205 F for the City of
Carmel, Indiana dated February 19, 2003.
Note: Per Carmel zoning ordinance 26.1.1 :: The
residential district limits height to twenty-five feet
(25'), however 0 dwelling may be increased 'in
height to thirty-five feet (35') provided the: side
and rear ~rds ore increased an additional One
foot (1') for eoch one foot (1') the structure
exceeds the first twenty-five feet (25') in height.
~GNA lURE :
DAlE:
~GNA lURE REPRESENTS COORR~A]OO OF RECEIPT OF PLOT PlAN BY CUSTOMER.