HomeMy WebLinkAboutC200DYH
U.P.
U.P.
U.P.
U.P.
U.P.U.P.
U.P.
S
S
D
S
U.P.U.P.
U.P.
S
RW
S
RW
U.P.
U.P.
S
S
834 83
3
832 831
830
82
9
83
0
831 82
9
828
82
8
827
828829
8
3
0
8
3
1
83
0
83
1
83
2
833
83
0
82
9
82
8
8
2
7
8
2
6
8
2
5
8
2
4
8
2
3
8
2
2
82
1
8
2
0
81
9
8
1
8
81
7
81
6
81
5
81
6
8
1
7
81
8
81
9
8
1
5
8
1
6
8
1
5
8
1
6
8
1
7
8
1
8
8
2
0
8
2
1
8
2
2
8
2
3
8
2
4
8
2
5
8
2
6
8
2
7
8
2
8
8
2
9
8
3
0
8
3
1
8
3
2
8
3
3
8
3
4
8
3
5
8
3
6
8
3
7
8
3
8
8
3
9
8
4
0
841
8
4
2
8
4
3
8
4
4
845
84
5
846
847
848
849
850
85
1
85
2
85
3
85
2
851850849
84
8847
85
2
85
1
85
0
84
9
84
8
84
7
84
6
8
4
5
84
4
84
3
84
2
84
1
84
0
8
3
9
8
3
8
8
3
7
8
3
6
8
3
5
83
4
83
3
83
2
8
3
1
8
3
0
8
2
9
8
2
8
8
2
7
8
2
6
8
2
5
8
2
4
8
2
3
8
2
2
821
820
819
818
81
7
81
6
81
5
Sanitary Manhole
TC=821.81
N: 12"PVC, Inv=807.28
S: 12"PVC, Inv=807.07
Sanitary Manhole
TC=824.70
N: 12"PVC, Inv=806.36
NE: 12"PVC, Inv=806.29
Storm Manhole
TC=829.91
N: 12"HDPE, Inv=823.69
E: 24"HDPE, Inv=816.85
W: 24"HDPE, Inv=816.93
Curb Inlet
TC=829.83
S: 12"HDPE, Inv=823.76
Sanitary Manhole
TC=833.34
E: 8"PVC, Inv=822.38
S: 8"PVC, Inv=823.16
W: 8"PVC, Inv=823.25
Sanitary Manhole
TC=834.76
N: 8"PVC, Inv=826.76
S: 8"PVC, Inv=826.86
Sanitary Manhole
TC=828.71
N: 12"PVC, Inv=807.91
S: 12"PVC, Inv=807.81
SW: 8"PVC, Inv=809.91
Sanitary Manhole
TC=828.36
NE: 8"PVC, Inv=810.79
W: 8"PVC, Inv=812.80
TBM #2TBM #1 EXISTING PATH
Approx. Top of Bank
W.R. Fertig Open
Regulated Dain
15' Electric & Tcomm. Easement
Instr. No. 2019025955 &
Instr. No. 2019031338
15' Electric & Tcomm. Easement
Instr. No. 2019025955 &
Instr. No. 2019031338
15' Electric & Tcomm. Easement
Instr. No. 2019025955 &
Instr. No. 2019031338
Va
r
.
W
i
d
t
h
D
r
a
i
n
a
g
e
,
A
c
c
e
s
s
&
M
a
i
n
t
e
n
a
n
c
e
Ea
s
e
m
e
n
t
,
I
n
s
t
.
N
o
.
2
0
0
3
0
0
1
2
7
2
9
0
20' Sewer Easement
Inst. No. 8702420
20' Sewer Easement
Inst. No. 8702420
VAR. WATER
QUALITY
PRESERVATION
EASEMENT
Approx. Limit of
W.R. Fertig Open
Regulated Dain
CARMEL CREEK
VAR. WATER
QUALITY
PRESERVATION
EASEMENT
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF SF SF SF
SF
SF
SF SF S
F
S
F
S
F
S
F
SF
116TH STREET
25
'
B
.
L
.
25
'
B
.
L
.
POSTING SIGN
LOCATION
C200
DA
T
E
MA
R
K
RE
V
I
S
I
O
N
S
BY
CE
R
T
I
F
I
E
D
:
S & A JOB NO.
SHEET NO.
DRAWN BY:CHECKED BY:
S
T
O
E
P
P
E
L
W
E
R
T
H
A
L
W
A
Y
S
O
N
79
6
5
E
a
s
t
1
0
6
t
h
S
t
r
e
e
t
,
F
i
s
h
e
r
s
,
I
N
4
6
0
3
8
-
2
5
0
5
ph
o
n
e
:
3
1
7
.
8
4
9
.
5
9
3
5
f
a
x
:
3
1
7
.
8
4
9
.
5
9
4
2
TH
I
S
D
R
A
W
I
N
G
I
S
N
O
T
I
N
T
E
N
D
E
D
T
O
B
E
RE
P
R
E
S
E
N
T
E
D
A
S
A
R
E
T
R
A
C
E
M
E
N
T
O
R
OR
I
G
I
N
A
L
B
O
U
N
D
A
R
Y
S
U
R
V
E
Y
,
A
R
O
U
T
E
SU
R
V
E
Y
O
R
A
S
U
R
V
E
Y
O
R
L
O
C
A
T
I
O
N
RE
P
O
R
T
.
IN
I
T
I
A
L
S
T
O
R
M
W
A
T
E
R
P
O
L
L
.
&
P
R
E
V
.
P
L
A
N
50'25'50'0
GRAPHIC SCALE
( IN FEET )
1" = 50 FT
THIS SHEET TO BE USED
FOR EROSION CONTROL
ONLY.
PERSON ONSITE RESPONSIBLE FOR EROSION CONTROL:
MARK GRADISON - GRADISON BUILDING CORPORATION
6330 EAST 75TH STREET, SUITE 156
INDIANAPOLIS, INDIANA 46250
PHONE: (317) 506-1037
NOTES
1.ADDITIONAL EROSION CONTROL MEASURES MAY BE REQUIRED IN THE
FIELD BY THE INSPECTOR.
LEGEND
DENOTES CONSTRUCTION LIMITS
DENOTES SILT FENCE
TEMPORARY BELOW GRADE "DROP INLET PROTECTION BASKET"
TEMPORARY "DROP INLET PROTECTION BASKET", "SEDIMENT
CONTROL DEVICES"
DENOTES EXISTING FLOW ONTO THE SITE
111895GBC
SW
I
N
L
E
Y
F
O
R
E
S
T
KJJM LAF
CA
R
M
E
L
HA
M
I
L
T
O
N
C
O
U
N
T
Y
,
I
N
D
I
A
N
A
12
/
1
8
/
2
0
2
4
SWINLEY FOREST
ZONING: R-1
PRIMARY PLATSTOEPPELWERTH & ASSOCIATES, INC.
THIS INSTRUMENT PREPARED BY:
DENNIS D. OLMSTEAD, PLS
STOEPPELWERTH & ASSOCIATES, INC.
7965 E. 106TH STREET
FISHERS, INDIANA 46038
PHONE: (317) 849-5935
THIS INSTRUMENT PREPARED FOR:
GRADISON BUILDING CORPORATION
6330 EAST 75TH STREET, SUITE 156
INDIANAPOLIS, IN 46250
CONTACT: MARK GRADISON
PHONE: (317) 506-1037
The following is a list in sequence of construction activities to control soil erosion:
1.The contractor shall schedule a Pre-construction meeting with Hamilton County prior to any constructing on the site
being started. The contractor and/or developer shall notify Hamilton County 48 hours prior to start of construction.
2.Following the required pre-construction meeting the contractor shall install the “posting information center”. The
location of the posting information center is shown on Sheet C200. The posting information center is the location
where a copy of the approved Construction General Permit, Approved SWPP Plan, signed O&M Manual and
Maintenance Logs are to be located.
3.Prior to any earth moving the contractor shall install all silt fence as shown on Sheet C200 & C201. The details and
specifications for silt fence installation are located on Sheet C205.
4.Contact the Surveyors Office to schedule an Initial Erosion Inspection to obtain a full sign off on the (ILP).
5.When the "existing site/construction limits are completely stabilized, the contractor shall start stripping the existing top
soil. Please see Sheet C205 for the temporary seed mixture and rate.
6.Contractor shall continue to grade the remainder of the site and prepare the sub-grade for the proposed driveways. If
lime stabilization is the method chosen, dust shall be kept to a minimum. Dust shall be removed from the construction
vehicles prior to leaving the site.
7.Contractor shall installed the storm pipes.
8.Contractor shall install all asphalt pavement.
9.The contractor shall permanent seed all disturbed areas that are illustrated on Sheet C202. The seed mixture and rate
can be found on Sheet C204.
10.The contractor shall schedule a site inspection with the Hamilton County to ensure that the site is stabilized. After the
inspector approves the site conditions the contractor shall remove all temporary erosion control practices.
11.The post-construction erosion control practices then become the responsibility of the developer of this project.
12.The developer of this project shall continue to monitor this site for good house keeping on the post-construction BMP's
until a NOT is filed with IDEM.
A
N
L N
R
STATE OF
D SU
I AIDN
YVE
A RO
NN
DE D
A
E
ODS
GE
I
R
TIS
.LM
D
RE
S
E
T