HomeMy WebLinkAboutA232 - EXTERIOR VIEWS3'-4"
MIN.
2'-2"1'-2"
2'
-
6
"
PROVIDE 2X8
BLOCKING
OPTION 1
REAR WALL BLOCKING
DIAGRAMS ALL UNITS
OPTION 2
APPLIES ONLY WHERE AN
ADJACENT VANITY ENCROACHES INTO
THE 40" BLOCKING EXTENTS.
TOILETS
TYPE A & TYPE B BATHROOMS
3'
-
2
"
2'-4"
1'-2"1'-2"
1'-6"
3'-0" MIN
TYPE A
2'
-
6
"
PROVIDE 2X8
BLOCKING
2'-9" MIN
TYPE B
MIN.
OPTION 2
3'
-
2
"
10"3'-10"
2'
-
6
"
PROVIDE 2X8
BLOCKING
OPTION 1
MIN.
3'
-
2
"
10"2'-4"
2'
-
6
"
PROVIDE 2X8
BLOCKING
OPTION 2
3'
-
2
"
18" MIN
8"
2'
-
0
"
PROVIDE (2)
ROWS 2X8
BLOCKING
TYPE B
UNITS ONLY
WHERE WATER CLOSET
OCCURS BETWEEN
BATHTUBS AND LAVATORY.
15" MIN
1'
-
2
"
2'
-
6
1
2"
HEAD WALL
PROVIDE 2X8
BLOCKING
2'-0"
8"
3'
-
2
"
BACK WALL
PROVIDE (2)
ROWS 2X8
BLOCKING
6"
M
A
X
6"
MAX.
4'-0"6"
MAX.
2'-4"
3'
-
2
"
CONTROL WALL
PROVIDE 2X8
BLOCKING
5'
-
6
"
MI
N
.
TUBS
ALL UNITS
2'
-
6
"
HORIZONTAL BLOCKING
TO BE 18 GAUGE METAL
CONTROL WALL ONLY.
CONTROLS IN TYPE A
ACCESSIBLE BATHTUBS
SHALL BE LOCATED
BETWEEN THE BATHTUB
RIM AND LOWER GRAB
BAR, AND BETWEEN THE
OPEN SIDE OF THE
BATHTUB AND THE TUB
CENTERLINE.
BLOCKING TO
EXTEND TO
CENTERLINE
OF CONTROL
WALL
W D
30" X 48" CLEAR FLOOR
SPACE FOR PARALLEL
APPROACH TO EACH
APPLIANCE PER SECTION
1004.10
FIG. C1004.10(a)
FOR SI: 1 INCH = 25.4 MM.
W D
30" X 48" CLEAR FLOOR
SPACE FOR PARALLEL
APPROACH TO EACH
APPLIANCE PER SECTION
1004.10
FIG. C1004.10(B)
LAUNDRY ROOM, TYPE B UNITS
FOR SI: 1 INCH = 25.4 MM.
54" MIN
39" MIN.
41" MAX.
12"
MAX
42" MIN
36
"
M
A
X
.
33
"
M
I
N
.
39
"
M
I
N
.
41
"
M
A
X
.
18
"
M
I
N
FIG. 604.5.1
SIDE WALL GRAB FOR
WATER CLOSET
36" MIN
24" MIN 12" MIN
36
"
M
A
X
.
33
"
M
I
N
.
FIG. 604.5.2
REAR WALL GRAB
FOR WATER CLOSET
18" MIN18" MIN
28
"
M
I
N
15 3/4"15 3/4"
ANSI A117.1 2017: 1104.11.1.1
SWING-UP GRAB BAR
FOR WATER CLOSET
60" MIN
48
"
M
I
N
CO
N
T
R
O
L
E
N
D
W
A
L
L
BACK WALL
HE
A
D
E
N
D
W
A
L
L
18
"
M
I
N
48" MIN
30
"
M
I
N
36
"
M
I
N
36" MIN
SE
A
T
W
A
L
L
BACK WALL
CO
N
T
R
O
L
W
A
L
L
60" MIN
30
"
M
I
N
LAVATORY
COMPLYING WITH
SECTION 606
CO
N
T
R
O
L
E
N
D
W
A
L
L
BACK WALL
HE
A
D
E
N
D
W
A
L
L
(a)
66
"
M
I
N
18"
48" MIN
(c)FORWARD APPROACH
24
"
M
A
X
.
33" MIN.24" MIN.
WALL TO CL
15" MIN 18"
*18 MIN (455) TO A FIXTURE
56
"
M
I
N
18"42" MIN
(d)PARALLEL OR FORWARD
APPROACH
FIG. 1004.11.3.1.2
WATER CLOSETS IN
TYPE B UNITS
56
"
M
I
N
48" MIN
18"
(b)PARALLEL APPROACH
24
"
M
A
X
.
33" MIN.
FIG. 1004.11.3.1.3.2
FORWARD APPROACH BATHTUB
IN TYPE B UNITS - OPTIONS A
BATHROOMS
FIG. 1004.11.3.1.3.3
TRANSFER-TYPE SHOWER
COMPARTMENT IN TYPE
B UNITS
PR
O
J
E
C
T
DR
A
W
I
N
G
T
I
T
L
E
SE
A
L
SH
E
E
T
PR
O
J
E
C
T
I
N
F
O
RE
V
I
S
I
O
N
S
22028
DECEMBER 13, 2024
50% DD SET
#DESCRIPTION DATE
BU
C
K
I
N
G
H
A
M
A
T
GR
A
M
E
R
C
Y
ARCHITECT
GC/CM
CLIENT
A231
EXTERIOR VIEWS
SCALE:
01 AREA AT BATHROOMS
REINFORCED WALL
N.T.S.SCALE:
02 TYPE B UNITS
N.T.S.