Loading...
HomeMy WebLinkAboutA931 - MONUMENTAL SIGNA931 MO N U M E N T A L SI G N SCALE: 05 MONUMENTAL SITE SIGN N.T.S. PR O J E C T DR A W I N G T I T L E SE A L SH E E T PR O J E C T I N F O RE V I S I O N S 22028 DECEMBER 13, 2024 50% DD SET #DESCRIPTION DATE BU C K I N G H A M A T GR A M E R C Y ARCHITECT GC/CM CLIENT SCALE: 01 MONUMENTAL SIGN PLANS 1 1/2" = 1'-0"SCALE: 02 SECTION 1 1/2" = 1'-0" 2 8'-4" 112" 1'-0"7'-1" 112" 65 8"67 8" OUTLINE OF ALUM. COPING ABOVE 1' - 7 " 11 2" 3" 10 " 11 2" 3" 21 4 " 51 2" 21 4" BRICK VENEER WEATHER BARRIER ON 7 16 SHEATHING ON 2x6 WOOD FRAMING @ 24" O.C. DIMS. TO FINISH FACE OF MATERIALS DIMS. FROM FOOTING TO FRAMING CONT. SEALANT OUTLINE OF BRICK BELOW OUTLINE OF ALUM. COPING ABOVE 'B' FLOOR PLAN AT UPPER PORTION OF LONG SIGN 8'-3" 1"8'-1"1" 618"7'-23 4"618" 1' - 6 " 1" 1' - 3 7 8" 1" 61 4" 51 2" 61 4 " WEATHER BARRIER ON 7 16 SHEATHING ON 2x6 WOOD FRAMING @ 24" O.C. DIMS. TO FINISH FACE OF MATERIALS DIMS. FROM FOOTING TO FRAMING OUTLINE OF CONCRETE FOOTING / BASE BELOW OUTLINE OF CONCRETE FOOTING / BASE BELOW 'A' FLOOR PLAN AT LOWER PORTION OF LONG SIGN 2 A931 3 A931 SCALE: 03 SECTION 1 1/2" = 1'-0" 1'-7" 1'-6" 3' - 7 1 2" 4" 3' - 2 " 11 2" 8" 2' - 6 " 11 2" 3"10"3" 11 2" 1'-7" 1'-6" 3' - 7 1 2" 4" 3' - 2 " 11 2" 11 2"51 4"512"514"11 2" ALUM. COPING SYSTEM AS DESCRIBED ON DETAIL 4 OF THIS SHEET. PROVIDED AND INSTALLED BY SIGN MFR. OUTLINE OF BRICK BEYOND WEATHER BARRIER ON 7 16" SHEATHING ON FLAT 1x4'S @ 24" O.C. 7 16" SHEATHING ON 2x6 WOOD FRAMING @ 24" O.C. MTL. FLASHING / DRIP EDGE. EXTEND ON TOP OF HRZ. SHEATHING MTL. FLASHING / DRIP EDGE. EXTEND UP FACE OF SHEATHING MIN. 6 INCHES. TAPE-FLASH AT END OF VERTICAL LEG BRICK VENEER MORTAR NET WEEPS @ 24" O.C. MAX. GRADE PER CIVIL DWGS. FOOTING PER STRUCTURAL DWGS. WEATHER BARRIER 7 16" SHEATHING ON 2x6 WOOD FRAMING @ 24" O.C. MTL. FLASHING / DRIP EDGE. EXTEND UP FACE OF SHEATHING MIN. 6 INCHES. TAPE-FLASH AT END OF VERTICAL LEG BRICK VENEER MORTAR NET WEEPS @ 24" O.C. MAX. GRADE PER CIVIL DWGS. FOOTING PER STRUCTURAL DWGS. 1-B A931 1-A A931 1-A A931 2 A931 1' - 6 " EQ . EQ . 51 4 " 31 2" 51 4" 3'-2" EQ.2'-15 8"EQ. 1"1" 1' - 2 " 2" 10 " 2" 3'-2" 3'-0"1"1" OUTLINE OF ALUM. COPING ABOVE 4 A931 2 A931 'D' FLOOR PLAN AT UPPER PORTION OF SHORT SIGN 'C' FLOOR PLAN AT LOWER PORTION OF SHORT SIGN SCALE: 04 SECTION 1 1/2" = 1'-0" 1'-2" 3' - 7 1 2" 4" 3' - 2 " 11 2" 8" 2' - 6 " 2"10"2" 1'-6" 1'-2" 1-B A931 1-A A931 REF. DETAIL 3 ON THIS SHEET FOR NOTES SIGN CABINET AS DESCRIBED ON DETAIL 4 ON THIS SHEET. PROVIDED AND INSTALLED BY SIGN MANUFACTURER ALUM. COPING SYSTEM AS DESCRIBED ON DETAIL 4 OF THIS SHEET. PROVIDED AND INSTALLED BY SIGN MFR. SIGN CABINET AS DESCRIBED ON DETAIL 4 ON THIS SHEET. PROVIDED AND INSTALLED BY SIGN MANUFACTURER 2"2" 3'-0" WEATHER BARRIER ON 7 16 SHEATHING ON 2x4 WOOD FRAMING @ 24" O.C. BRICK VENEER SIGN CABINET AS DESCRIBED ON DETAIL 4 ON THIS SHEET. PROVIDED AND INSTALLED BY SIGN MANUFACTURER SCALE: 06 SECONDARY SITE SIGN N.T.S. SIGNAGE SIGNAGE SIGNAGESIGNAGESIGNAGE