HomeMy WebLinkAboutA931 - MONUMENTAL SIGNA931
MO
N
U
M
E
N
T
A
L
SI
G
N
SCALE:
05 MONUMENTAL SITE SIGN
N.T.S.
PR
O
J
E
C
T
DR
A
W
I
N
G
T
I
T
L
E
SE
A
L
SH
E
E
T
PR
O
J
E
C
T
I
N
F
O
RE
V
I
S
I
O
N
S
22028
DECEMBER 13, 2024
50% DD SET
#DESCRIPTION DATE
BU
C
K
I
N
G
H
A
M
A
T
GR
A
M
E
R
C
Y
ARCHITECT
GC/CM
CLIENT
SCALE:
01 MONUMENTAL SIGN PLANS
1 1/2" = 1'-0"SCALE:
02 SECTION
1 1/2" = 1'-0"
2
8'-4"
112"
1'-0"7'-1"
112"
65 8"67 8"
OUTLINE OF ALUM. COPING
ABOVE
1'
-
7
"
11
2"
3"
10
"
11
2"
3"
21
4
"
51
2"
21
4"
BRICK VENEER
WEATHER BARRIER ON 7
16
SHEATHING ON 2x6 WOOD
FRAMING @ 24" O.C.
DIMS. TO FINISH FACE OF MATERIALS
DIMS. FROM FOOTING TO FRAMING
CONT. SEALANT
OUTLINE OF BRICK BELOW
OUTLINE OF ALUM. COPING
ABOVE
'B' FLOOR PLAN AT UPPER PORTION OF LONG SIGN
8'-3"
1"8'-1"1"
618"7'-23 4"618"
1'
-
6
"
1"
1'
-
3
7
8"
1"
61
4"
51
2"
61
4
"
WEATHER BARRIER ON 7
16
SHEATHING ON 2x6 WOOD
FRAMING @ 24" O.C.
DIMS. TO FINISH FACE OF MATERIALS
DIMS. FROM FOOTING TO FRAMING
OUTLINE OF CONCRETE
FOOTING / BASE BELOW
OUTLINE OF CONCRETE
FOOTING / BASE BELOW
'A' FLOOR PLAN AT LOWER PORTION OF LONG SIGN
2
A931
3
A931
SCALE:
03 SECTION
1 1/2" = 1'-0"
1'-7"
1'-6"
3'
-
7
1
2"
4"
3'
-
2
"
11
2"
8"
2'
-
6
"
11 2"
3"10"3"
11 2"
1'-7"
1'-6"
3'
-
7
1
2"
4"
3'
-
2
"
11
2"
11 2"51 4"512"514"11 2"
ALUM. COPING SYSTEM AS
DESCRIBED ON DETAIL 4 OF
THIS SHEET. PROVIDED AND
INSTALLED BY SIGN MFR.
OUTLINE OF BRICK BEYOND
WEATHER BARRIER ON 7
16"
SHEATHING ON FLAT 1x4'S @
24" O.C.
7
16" SHEATHING ON 2x6
WOOD FRAMING @ 24" O.C.
MTL. FLASHING / DRIP
EDGE. EXTEND ON TOP OF
HRZ. SHEATHING
MTL. FLASHING / DRIP
EDGE. EXTEND UP FACE OF
SHEATHING MIN. 6 INCHES.
TAPE-FLASH AT END OF
VERTICAL LEG
BRICK VENEER
MORTAR NET
WEEPS @ 24" O.C. MAX.
GRADE PER CIVIL DWGS.
FOOTING PER STRUCTURAL
DWGS.
WEATHER BARRIER
7
16" SHEATHING ON 2x6
WOOD FRAMING @ 24" O.C.
MTL. FLASHING / DRIP EDGE.
EXTEND UP FACE OF
SHEATHING MIN. 6 INCHES.
TAPE-FLASH AT END OF
VERTICAL LEG
BRICK VENEER
MORTAR NET
WEEPS @ 24" O.C. MAX.
GRADE PER CIVIL DWGS.
FOOTING PER STRUCTURAL
DWGS.
1-B
A931
1-A
A931
1-A
A931
2
A931
1'
-
6
"
EQ
.
EQ
.
51
4
"
31
2"
51
4"
3'-2"
EQ.2'-15 8"EQ.
1"1"
1'
-
2
"
2"
10
"
2"
3'-2"
3'-0"1"1"
OUTLINE OF ALUM. COPING
ABOVE
4
A931
2
A931
'D' FLOOR PLAN AT UPPER PORTION OF SHORT SIGN
'C' FLOOR PLAN AT LOWER PORTION OF SHORT SIGN
SCALE:
04 SECTION
1 1/2" = 1'-0"
1'-2"
3'
-
7
1
2"
4"
3'
-
2
"
11
2"
8"
2'
-
6
"
2"10"2"
1'-6"
1'-2"
1-B
A931
1-A
A931
REF. DETAIL 3 ON THIS
SHEET FOR NOTES
SIGN CABINET AS DESCRIBED
ON DETAIL 4 ON THIS SHEET.
PROVIDED AND INSTALLED BY
SIGN MANUFACTURER
ALUM. COPING SYSTEM AS
DESCRIBED ON DETAIL 4 OF
THIS SHEET. PROVIDED AND
INSTALLED BY SIGN MFR.
SIGN CABINET AS DESCRIBED
ON DETAIL 4 ON THIS SHEET.
PROVIDED AND INSTALLED BY
SIGN MANUFACTURER
2"2"
3'-0"
WEATHER BARRIER ON 7
16
SHEATHING ON 2x4 WOOD
FRAMING @ 24" O.C.
BRICK VENEER
SIGN CABINET AS
DESCRIBED ON DETAIL 4
ON THIS SHEET. PROVIDED
AND INSTALLED BY SIGN
MANUFACTURER
SCALE:
06 SECONDARY SITE SIGN
N.T.S.
SIGNAGE
SIGNAGE
SIGNAGESIGNAGESIGNAGE