Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
A104.2 - BUILDING PLANS -BLDG 4
GENERAL NOTES PLAN NOTES 1 2 3 1. APARTMENT BUILDINGS TO BE EQUIPPED WITH NFPA 13R SPRINKLER SYSTEM. 2. UNITS IN THIS SET LISTED AS "ANSI" ARE DESIGNED AS A117.1 ANSI TYPE A UNITS. ALL OTHER FIRST FLOOR UNITS ARE DESIGNED AS A117.1 ANSI TYPE B UNITS. ALL FIRST FLOOR UNITS ARE TO COMPLY WITH THE ACCESSIBILITY CODES LISTED ON THE COVER SHEET. 3. REFER TO A400 SERIES FOR UNIT PLANS, UNIT DIMENSIONS, ROOM LABELS, AND MORE INFORMATION. 4. SECTION CUTS ARE CALLED OUT ON A200 SERIES BUILDING ELEVATION SHEETS. 5. SEE A311 SERIES FOR TYPICAL INTERIOR SECTIONS AT DEMISING WALLS AND STAIR WALLS. 6. ALL PENETRATIONS THROUGH RATED ASSEMBLIES ARE TO BE PROTECTED AS PER APPLICABLE UL SYSTEM LISTING. SEE A030 SERIES. 7. ALL OPENINGS THROUGH DRAFTSTOP IN ATTIC SHALL BE EQUIPPED WITH SELF CLOSING/LATCHING HARDWARE. 8. ALL VERTICAL WALL GYPSUM BOARD SHALL BE 5/8”TYPE X. HORIZONTAL CEILING BOARD TO BE 5/8”TYPE C. 9. LOCATE GYPSUM BOARD CONTROL JOINTS AS SPECIFIED BY THE USG GYPSUM CONSTRUCTION HANDBOOK LIMITING EXPANSES TO THIRTY FEET. 10. ALL CEILINGS HEIGHTS IN UNITS ARE 9'-0" A.F.F. 11. ALL SLOPED CONCRETE SURFACES ARE TO RECEIVE BROOM FINISH. FIRE EXSTINGUISHER IN SEMI RECESSED CABINET, SEE A452. 3" X4" ALUMINUM DOWNSPOUT AND CONCRETE SPLASH BLOCK. 20" X 40" ATTIC ACCESS. FURRED WALL FOR METER CENTER BUILT AT INDICATED LOCATIONS ONLY. WALL TO BE WG3a TYPE, EXTEND UP TO UNIT CEILING TYPICAL. SEE UNIT PLANS FOR MORE INFORMATION. FURRED WALL FOR ELECTRICAL LINESETS AT INDICATED FIRST FLOOR LOCATION ONLY. WALL TO BE WG3a TYPE. DROPPED BULKHEAD FOR MECHANICAL UNIT -SEE DETAIL 11/A181. REFERENCE MEP DRAWINGS. ELECTRIC METER LOCATION -SEE MEP DRAWINGS FOR MORE INFORMATION. EXTERIOR BUILD-OUT FOR METER CENTER -SEE SHEET A302 FOR MORE INFORMATION. BUILDING STEP @ 24" -SEE SHEET 311 FOR MORE INFORMATION. REFERNCE CIVIL DRAWINGS FOR CONDITIONS AT GRADE. 4 5 6 7 8 9 33 3 666 111 2 2 2 2 22 22 2 22 2 31' - 10" 32' - 4 1/2" 31' - 10" 32' - 7 1/4" 31' - 7" 19' - 11 1/2" 11' - 10 1/2" 11' - 0 3/4" 10' - 3" 11' - 0 3/4" 11' - 5" 20' - 5" 11' - 0 3/4" 10' - 3" 11' - 3 1/2" 11' - 7 3/4" 19' - 11 1/4" 65 ' - 9 1 / 2 " 65 ' - 6 3 / 4 " 60 ' - 9 1 / 2 " 5 ' - 0 " 12 ' - 3 " 4 2 ' - 7 " 5 ' - 1 1 1 / 2 " 5 ' - 0 " 5' - 0 " 6 0 ' - 6 3 / 4 " 5' - 0 " 5 ' - 8 3 / 4 " 4 2 ' - 7 " 1 2 ' - 3 " 182' - 6 1/4" 14' - 6 1/2" 25' - 0 1/2" 38' - 10 1/4" 25' - 6 3/4" 39' - 3" 24' - 11 1/2" 14' - 3 3/4" 3' - 3" 11' - 3 1/2" 15' - 9 3/4" 6' - 8" 2' - 6 3/4" 11' - 3 1/2" 16' - 6 3/4" 11' - 0" 2' - 10 1/4" 6' - 8" 16' - 0 1/2" 11' - 0 3/4" 16' - 10 3/4" 11' - 3 1/2" 2' - 6 3/4" 6' - 8" 15' - 8 3/4" 11' - 0 3/4" 3' - 3" 3' - 3" 5' - 9 3/4" 5' - 5 3/4" 4' - 5 1/4" 3' - 7" 8' - 3 3/4" 2' - 10" 2' - 10" 3' - 0 3/4" 5' - 5 3/4" 5' - 9 3/4" 16' - 6 3/4" 5' - 11 1/4" 5' - 0 3/4" 3' - 4 1/2" 2' - 10" 2' - 10" 5' - 9 3/4" 3' - 7" 7' - 2" 5' - 1 3/4" 5' - 11" 16' - 10 3/4" 3' - 10 1/2" 1' - 7" 5' - 10" 3' - 0 3/4" 2' - 10" 2' - 10" 5' - 9 3/4" 3' - 7" 6' - 10 1/4" 5' - 3 1/2" 5' - 9 1/4" 3' - 3" 4' - 11" 3' - 10" 5' - 0" 7' - 1" 4' - 0 1/2" 5' - 10" 6' - 0 1/2" 5' - 7" 5' - 5 3/4" 4' - 11 1/4" 5' - 3 3/4" 5' - 7 3/4" 5' - 5" 5' - 2" 6' - 5 3/4" 3' - 4 1/2" 7' - 1" 5' - 0" 4' - 8 1/2" 5' - 5" 5' - 7 3/4" 5' - 3 1/2" 4' - 11 1/2" 5' - 5 3/4" 5' - 9 3/4" 5' - 9 3/4" 5' - 10"4' - 0 1/2" 7' - 1" 5' - 0" 3' - 10" 5' - 3" PITCHED ROOF: ASPHALT SINGLE ON FELT PAPER OVER WOOD SHEATHING, WOOD TRUSSES RIDGE VENT, TYP. VENTED SOFFIT AT PERIMETER, TYP. 2 2 2 2 2 2 2 2 2 2 2 1 51 1 5 1 1 1 1 1 5 1 5 5 2 3 3 3 3 3333 2 2 3 2 5 5 5 5 5 2 4 4 7 4 4 7 4 4 7 5 5 5 8 8 8 8 8 8 3 3 3 10" / 12"10" / 12" 6" / 1 2 " 6" / 1 2 " 6" / 1 2 " 6" / 1 2 " 6" / 1 2 " 6" / 1 2 " 6" / 1 2 " 6" / 1 2 " 10" / 12"10" / 12"10" / 12"10" / 12"10" / 12"10" / 12" 10" / 12"10" / 12"10" / 12"10" / 12" 3" / 12"3" / 12" 1 1 1 ROOF PLAN LEGEND 1 CONTINUOUS RIDGE VENT 5" ALUMINUM GUTTER 3"X4" DOWNSPOUT 20"x40" ACCESS DOOR PROVIDED FOR EACH AREA OF SEPERATION. DRAFTSTOP SHALL BE PROVIDEED ON FLOOR/CEILING AND ROOFING/CEILING SPACE PER SECTION 718. DASHED LINE REPRESENTS WALL BELOW. 20"x40" RATED ATTIC ACCESS PANEL FOR MECHANICAL UNIT MAINTENANCE - SEE CODE PLANS FOR MORE INFORMATION. ROOF VENT PENETRATION, PROVIDE BOOT FLASHING PER MANUFACTURERS STANDARDS -SEE PLUMBING DRAWINGS FOR MORE INFORMATION. # 2 3 4 5 6 7 8 PR O J E C T DR A W I N G T I T L E SE A L SH E E T PR O J E C T I N F O RE V I S I O N S ARCHITECT GC/CM CLIENT Autodesk Docs://22028_Buckingham_GramercyApartments/22028_BHGramercy_Apartments-Silver_Central.rvt 12/12/2024 4:48:04 PM 22028 DECEMBER 13, 2024 50% DD SET A104.2 BU I L D I N G P L A N S - B L D G 4 BU C K I N G H A M A T GR A M E R C Y SCALE: 1/8" = 1'-0"1 THIRD FLOOR PLAN SCALE: 1/8" = 1'-0"2 ROOF PLAN 1309 2BR2A.1 1306 1BR1A.1 1305 1BR1A.2 1302 2BR2A.2 1311 2BR2B.1 1308 1BR1B.1 1307 1BR1B.2 1304 2BR2B.2 1303 1BR1B.21312 1BR1B.1 1310 1BR1A.1 1301 1BR1A.2 #DESCRIPTION DATE