HomeMy WebLinkAboutA107.2 - BUILDING PLANS -BLDG 7GENERAL NOTES
PLAN NOTES
1
2
3
1. APARTMENT BUILDINGS TO BE
EQUIPPED WITH NFPA 13R SPRINKLER
SYSTEM.
2. UNITS IN THIS SET LISTED AS "ANSI" ARE
DESIGNED AS A117.1 ANSI TYPE A UNITS.
ALL OTHER FIRST FLOOR UNITS ARE
DESIGNED AS A117.1 ANSI TYPE B UNITS.
ALL FIRST FLOOR UNITS ARE TO
COMPLY WITH THE ACCESSIBILITY
CODES LISTED ON THE COVER SHEET.
3. REFER TO A400 SERIES FOR UNIT
PLANS, UNIT DIMENSIONS, ROOM
LABELS, AND MORE INFORMATION.
4. SECTION CUTS ARE CALLED OUT ON
A200 SERIES BUILDING ELEVATION
SHEETS.
5. SEE A311 SERIES FOR TYPICAL INTERIOR
SECTIONS AT DEMISING WALLS AND
STAIR WALLS.
6. ALL PENETRATIONS THROUGH RATED
ASSEMBLIES ARE TO BE PROTECTED AS
PER APPLICABLE UL SYSTEM LISTING.
SEE A030 SERIES.
7. ALL OPENINGS THROUGH DRAFTSTOP IN
ATTIC SHALL BE EQUIPPED WITH SELF
CLOSING/LATCHING HARDWARE.
8. ALL VERTICAL WALL GYPSUM BOARD
SHALL BE 5/8”TYPE X. HORIZONTAL
CEILING BOARD TO BE 5/8”TYPE C.
9. LOCATE GYPSUM BOARD CONTROL
JOINTS AS SPECIFIED BY THE USG
GYPSUM CONSTRUCTION HANDBOOK
LIMITING EXPANSES TO THIRTY FEET.
10. ALL CEILINGS HEIGHTS IN UNITS ARE
9'-0" A.F.F.
11. ALL SLOPED CONCRETE SURFACES ARE
TO RECEIVE BROOM FINISH.
FIRE EXSTINGUISHER IN SEMI RECESSED
CABINET, SEE A452.
3" X4" ALUMINUM DOWNSPOUT AND
CONCRETE SPLASH BLOCK.
20" X 40" ATTIC ACCESS.
FURRED WALL FOR METER CENTER BUILT
AT INDICATED LOCATIONS ONLY. WALL
TO BE WG3a TYPE, EXTEND UP TO UNIT
CEILING TYPICAL. SEE UNIT PLANS FOR
MORE INFORMATION.
FURRED WALL FOR ELECTRICAL
LINESETS AT INDICATED FIRST FLOOR
LOCATION ONLY. WALL TO BE WG3a
TYPE.
DROPPED BULKHEAD FOR MECHANICAL
UNIT -SEE DETAIL 11/A181. REFERENCE
MEP DRAWINGS.
ELECTRIC METER LOCATION -SEE MEP
DRAWINGS FOR MORE INFORMATION.
EXTERIOR BUILD-OUT FOR METER
CENTER -SEE SHEET A302 FOR MORE
INFORMATION.
BUILDING STEP @ 24" -SEE SHEET 311
FOR MORE INFORMATION. REFERNCE
CIVIL DRAWINGS FOR CONDITIONS AT
GRADE.
4
5
6
7
8
9
B
B
D
D
F
F
H
H
K
K
M
M
P
P
1 1
2 2
3 3
O
OC
C
E
E
G
G
J
J
L
L
N
NA
A
33 3
666
111
206' - 2 1/2"
5'
-
0
"
6
0
'
-
9
1
/
2
"
5'
-
0
"
5
5
'
-
9
1
/
2
"
32
'
-
1
0
3
/
4
"
3
2
'
-
1
0
3
/
4
"
65
'
-
9
1
/
2
"
3' - 0 1/4"
65
'
-
9
1
/
2
"
32
'
-
1
0
3
/
4
"
3
2
'
-
1
0
3
/
4
"
5'
-
0
"
60
'
-
9
1
/
2
"
5'
-
0
"
2
7
'
-
1
0
3
/
4
"
2
7
'
-
1
0
3
/
4
"
5
'
-
0
"
5'
-
0
"
7
'
-
3
"
2
0
'
-
7
3
/
4
"
5
'
-
1
0
"
1
6
'
-
1
1
/
4
"
5
'
-
11
1
/
2
"
12
'
-
4
"
2
3
'
-
5
3
/
4
"
1
9
'
-
0
1
/
4
"
5
'
-
1
1
1
/
2
"
5
'
-
0
"
WG4b WG4b
WG
5
a
WG4b WG4b
WG
5
a
WG5a
WG
5
a
WG5a
WG5a
WG4b WG4b
WG4b
WG5a
WG
4
b
WG5a
WG5a
WG
5
a
WG4b WG4b
WG
4
b
WG
5
a
WG4b WG4b
WG5a
WG
5
a
WG
5
a
206' - 2 1/2"
2 2 2 2
2
2
222
2
22
29' - 0 1/2" 24' - 1 1/2" 38' - 8 1/2" 25' - 6" 38' - 8 1/2" 25' - 6" 24' - 7 3/4"
18' - 0 1/4" 11' - 0" 14' - 8 1/4" 6' - 8" 2' - 9 1/2" 11' - 0" 16' - 8 1/2" 11' - 0" 2' - 9 1/2" 6' - 8" 16' - 0 1/2" 11' - 0" 16' - 8 1/2" 10' - 11 3/4" 2' - 9 1/2" 6' - 8" 16' - 0 1/2" 11' - 0" 13' - 7 3/4"
4' - 10 1/4" 13' - 2" 5' - 5 3/4" 5' - 6 1/4" 4' - 4 3/4" 5' - 0" 5' - 3 1/2" 3' - 4" 3' - 4"
2' - 9 1/2"
5' - 3" 5' - 9" 16' - 8 1/2" 5' - 4 1/4" 5' - 7 3/4" 2' - 9 1/2" 3' - 4" 3' - 4" 5' - 3 1/2" 5' - 0" 5' - 9" 5' - 7 3/4" 5' - 4 1/4" 16' - 8 1/2" 5' - 8 1/2" 5' - 3 1/2" 2' - 9 1/2" 3' - 4" 3' - 4" 5' - 7 1/4" 5' - 0" 5' - 5 1/4" 11' - 0" 7' - 10" 5' - 9 3/4"
21' - 5 3/4" 12' - 7" 6' - 8" 1' - 2" 11' - 5" 11' - 0 3/4" 10' - 3 1/2" 11' - 0 1/4" 11' - 5 1/4" 1' - 1 3/4" 6' - 8" 12' - 7" 11' - 0 3/4" 21' - 3 3/4" 19' - 3" 34' - 0 3/4"
4' - 10" 11' - 8 3/4" 4' - 11" 3' - 10" 5' - 0" 3' - 9" 3' - 4" 3' - 4"
1' - 1 3/4"
5' - 4 3/4" 6' - 0 1/2" 5' - 7" 5' - 5 3/4" 4' - 11 1/4" 5' - 3 3/4" 5' - 7 3/4" 5' - 5" 5' - 2" 6' - 3 1/4"
1' - 1 3/4"
3' - 4" 3' - 4" 2' - 10 1/2" 5' - 0" 4' - 8 1/2" 5' - 5"5' - 7 3/4" 5' - 3 1/2" 10' - 5 1/2" 5' - 7" 6' - 0 1/2" 5' - 4 3/4"
1' - 1 3/4"
3' - 4" 3' - 4" 3' - 9" 5' - 0" 3' - 10" 5' - 3" 11' - 4 3/4" 4' - 10"
21' - 5 3/4" 20' - 5" 55' - 2 3/4" 20' - 5 1/2" 43' - 9" 20' - 4 3/4" 21' - 5 3/4"
B
B
D
D
F
F
H
H
K
K
M
M
P
P
1 1
2 2
3 3
O
OC
C
E
E
G
G
J
J
L
L
N
NA
A
PITCHED ROOF: ASPHALT
SINGLE ON FELT PAPER
OVER WOOD SHEATHING,
WOOD TRUSSES
RIDGE VENT,
TYP.
VENTED SOFFIT
AT PERIMETER,
TYP.
2 2
2 2
2
2
2
22
2
2
2
1
51
1
5 1
1
1
1
1
5
1
5
5
2
3 3 3 3
3333
2
2
3
2
2
5
5
5
5
5
2
4 4
7
4 4
7
4 4
7
5
5
5
2
8
8
8
8 8
8
3
3
10" / 12"10" / 12"
6"
/
1
2
"
6"
/
1
2
"
6"
/
1
2
"
10" / 12"10" / 12"10" / 12"10" / 12"
6"
/
1
2
"
6" / 12"
6"
/
1
2
"
6"
/
1
2
"
6"
/
1
2
"
6"
/
1
2
"
6"
/
1
2
"
10" / 12"10" / 12"10" / 12"10" / 12"10" / 12"10" / 12"
6" / 12"
6"
/
1
2
"
ROOF PLAN LEGEND
1 CONTINUOUS RIDGE VENT
5" ALUMINUM GUTTER
3"X4" DOWNSPOUT
20"x40" ACCESS DOOR PROVIDED FOR
EACH AREA OF SEPERATION.
DRAFTSTOP SHALL BE PROVIDEED ON
FLOOR/CEILING AND ROOFING/CEILING
SPACE PER SECTION 718.
DASHED LINE REPRESENTS WALL BELOW.
20"x40" RATED ATTIC ACCESS PANEL
FOR MECHANICAL UNIT MAINTENANCE -
SEE CODE PLANS FOR MORE
INFORMATION.
ROOF VENT PENETRATION, PROVIDE
BOOT FLASHING PER MANUFACTURERS
STANDARDS -SEE PLUMBING DRAWINGS
FOR MORE INFORMATION.
#
2
3
4
5
6
7
8
PR
O
J
E
C
T
DR
A
W
I
N
G
T
I
T
L
E
SE
A
L
SH
E
E
T
PR
O
J
E
C
T
I
N
F
O
RE
V
I
S
I
O
N
S
ARCHITECT
GC/CM
CLIENT
Autodesk Docs://22028_Buckingham_GramercyApartments/22028_BHGramercy_Apartments-Silver_Central.rvt 12/12/2024 4:48:33 PM
22028
DECEMBER 13, 2024
50% DD SET
A107.2
BU
I
L
D
I
N
G
P
L
A
N
S
-
B
L
D
G
7
BU
C
K
I
N
G
H
A
M
A
T
GR
A
M
E
R
C
Y
SCALE: 1/8" = 1'-0"1 THIRD FLOOR PLAN
SCALE: 1/8" = 1'-0"2 ROOF PLAN
1311
2BR2A.3
1310
2BR2A.1
1307
1BR1A.1
1306
1BR1A.2 1302
2BR2A.2
1301
2BR2A.4
1313
3BR3A.1
1312
2BR2B.1
1309
1BR1B.1
1308
1BR1B.2 1304
2BR2B.2
1303
2BR2B.3
#DESCRIPTION DATE