HomeMy WebLinkAboutA101 CONSTRUCTION PLAN4
A101
A602 3
A602
7
14
13.1
13
12.9
15
16
17
TJKLMNPRS
A602
5
2
SERVER
104
VESTIBULE
103
OFFICE
106
CL
105
VAT
111CASH
110
TELLERS
102
CORRIDOR
117
JC
120
10' - 0"
11
'
-
0
"
4'
-
0
"
7'
-
1
"
8' - 4"7' - 2"5' - 6"
6
9'
-
3
"
11
'
-
3
"
8'
-
4
"
8'
-
4
"
5'
-
5
"
8'
-
8
"
10
'
-
7
"
13' - 0"
2' - 5"
11' - 10"
12' - 3"
8'
-
8
"
7'
-
0
"
OFFICE
108CL
107
COPY
109
ATM + AHD
113
CORRIDOR
112
CONFERENCE
114
OFFICE
115
VESTIBULE
100
OFFICE
116
OFFICE
124
OFFICE
125
OFFICE
126
OFFICE
127
LOUNGE
119
A601
1
RESTROOM
121
2
2
A101
2
A101
2
6'
-
5
"
A1.01 A1.01
A1.01A1.01
A1.01
A1.01A1.01
1 1
1
1
1
1
1
A602
A1.01A1.01
TYP.
2 3/8"
3A
4
2
1
4
4
A1.26
A602 4
A6021
100
110
105
107
104
A1.06
A1.09
A1.11A1.11
1
ABV.
ABV.
1
1
1ABV.
ABV.
ABV.
A1.14
5
55
A1.01
1 1
1ABV.
1
1
1
1
1
4
4
1
1
1
4
41ABV.1
1
4
4
2
1
1
1
1
1
1
2
1
A1.27
A1.27
A1.28
A1.28
12
ELEC.
128
127
126
125
124
6'
-
1
1
"
RESTROOM
122
103A
128
113
103B
1 13'
-
8
"
8' - 4"
5'
-
2
"
122
121
120
116114115
5
5
5
5
2' - 0"
LOBBY
101
A1.06
A1.06
A1.06
A1.09
A1.03 A1.03
A1.06
A1.03
A1.03
A1.03
A1.03
A1.03
A1.01
A1.09
A1.09
A1.29
A1.03
A1.03
A1.27
A1.28
A6028
A602
9
A602
10
A612
1
108
106
8'
-
4
"
8'
-
4
"
8'
-
4
"
8'
-
4
"
A60211
A1.06
EQ 3' - 0"EQ
A614
1
A1.31
A1.01A1.01
1
1
A1.06 A1.01 A1.01
GENERAL REFERENCE AND COORDINATION NOTES
1. REFER TO THE SPECIFIC TRADES DRAWINGS FOR COORDINATION OF
DEMOLITION, CONSTRUCTION AND INFORMATION NOT SHOWN ON
THIS PLAN FOR MECHANICAL, ELECTRICAL, PLUMBING,
CIVIL/STRUCTURAL, AND FIRE PROTECTION WORK
2. REFER TO THE ARCHITECTUAL FLOOR PLANS FOR COORDINATION OF
DEMOLITION, CONSTRUCTION AND INFORMATION NOT SHOWN ON
THIS PLAN. I.E.: WALL TYPES & DETAILS FOR NEW CONSTRUCTION.
3. REFER TO GENERAL NOTE SHEETS FOR STANDARDS.
A. SHEET G100 SERIES FOR CODE AND LIFESAFETY PLAN
INFORMATION AND COORDINATION ITEMS.
B. SHEET G200 SERIES FOR ACCESSIBILITY GUIDELINES, DRAWING
STANDARDS, ALL PHASES OF CONSTRUCTION FOR GENERAL
NOTES, LEGENDS, MATERIALS, ABBREVIATIONS & SYMBOLS AND
CODE SIGNAGE REQUIREMENTS.
WALL TYPE LEGEND
FULL HT PARTITION: 3 5/8" 20 GAUGE MTL STUDS @ 16" O.C. W/
SOUND BATT INSUL. AND 5/8" GYP. BD. ON BOTH SIDES FROM
FLOOR TO UNDERSIDE OF STRUCTURE . USE MOISTURE
RESISTANT GYP. BD. IN ALL WET LOCATIONS
1
FULL HT PARTITION: 6" 20 GAUGE MTL STUDS @ 16" O.C. W/
SOUND BATT INSUL. AND 5/8" CEMENT BD. ON BOTH SIDES FROM
FLOOR TO UNDERSIDE OF STRUCTURE . USE MOISTURE
RESISTANT CEMENT BD. IN ALL WET LOCATIONS
1A
PARTITION: 3 5/8" 20 GAUGE MTL. STUDS @16" O.C. W/ SOUND
BATT INSULATION AND 5/8" GYP. BD. ON BOTH SIDES FROM
FLOOR TO 6" ABOVE FINISH CEILING. BRACE TOP OF WALL BACK
TO STRUCTURE AS REQ'D, @ MIN. 32" O.C. USE MOISTURE
RESISTANT GYP. BD. IN ALL WET LOCATIONS
2
FULL HT PARTITION: 6" 20 GAUGE MTL. STUDS @ 16" O.C. FROM
FLOOR TO UNDERSIDE OF STRUCTURE W/ BATT INSULATION AND
5/8" GYP. BD. ON BOTH SIDES TO DECK.
3
FULL HT PARTITION: 6" 20 GAUGE MTL. STUDS @ 16" O.C. FROM
FLOOR TO UNDERSIDE OF STRUCTURE W/ BATT INSULATION AND
5/8" GYP. BD. ON ONE SIDE TO DECK.
3A
FULL HT PARTITION: 3 5/8" 20 GAUGE MTL. STUDS @ 16" O.C. W/
SOUND BATT INSULATION AND 5/8" GYP. BD. ONE SIDE. ALIGNED
TO MATCH ADJACENT WALLS.
4
5/8" GYPSUM BOARD ONE SIDE OF 7/8" HAT CHANNEL @ 16" ON
CENTER. GYPSUM BOARD TO BOTTOM OF STRUCTURE.5
EXISTING WINDOW FRAME
CL
OF EXISTING
WINDOW FRAME
5" NOM. WALL
END CAP FLASHING AND
TRIM TO MATCH PT-1
4 7/8" DRYWALL MOLDING
END CLOSURE #DMEC-4875
BY FRY REGLET CORP. OR EQUAL
SOLID SURFACE (SS-1)
WINDOW SILL
EXISTING
WINDOW SILL
EXISTING WINDOW
EXTERIOR
INTERIOR
A1.26
A1.06
GROUND LEVEL
0' -0"
SECOND FLOOR
15' -0"
J K
NOTE: G.C. TO COORDINATE W/ATM/AHD & SIGNAGE VENDORS FOR SOLID BLOCKING REQ'D
BEHIND SLEEVE OPENING AND EQUIP UNIT. SLEEVE MUST BE SECURE IN PLACE TO
PREVENT UNIT MOVING FROM WALL. G,C, TO COORDINATE ALL ATM & AHD EQUIPMENT &
OPENING DIMENSIONS WITH OWNER'S VENDOR.
2'
-
5
"
OP
E
N
I
N
G
2'
-
7
7
/
8
"
OPENING
2' - 1 3/4"
2' - 5"
OPENING
1' - 11 1/2"
OP
E
N
I
N
G
2'
-
1
1
/
2
"
SIGNAGE PERMITTED UNDER
SEPARATE COVER
1" INSULATED METAL PANEL
TO MATCH EXISTING BASE
BUILDING STOREFRONT
SHEET NUMBER:
DRAWING RELEASE:
JOB NUMBER:
SHEET TITLE:
PROFESSIONAL SEAL:
cleveland.
3142 Prospect Avenue
Cleveland, OH 44115
new york.
530 5th Avenue, 16th Floor
New York City, NY 10036
PLOTTED:
I hereby certify that this drawing, specification, plan or report
was prepared by me or under my direct supervision and that I
am a duly registered Architect under the laws of the state which
govern this project. WARNING: No person may alter
these documents unless person is "or under the direct supervision
of" the licensed record Architect. [including all copyrights; JCW]
Date:
John C. Workley Registration Number:
Expiration Date:
vocon.partners LLC
1/13/2025 4:11:46 PM
CONSTRUCTION PLAN
1155 S Rangeline Road,
Suite 140
Carmel, IN 46032
HNB CARMEL
200472.00
AR10100022
12 /31 /25
10/11/2024
A101SCALE:1/4" = 1'-0"1 CONSTRUCTION PLAN
KEYNOTES
NUMBER DESCRIPTION
A1.01 ALIGN FINISH FACE OF WALLS.
A1.03 FALK WALL SYSTEM PROVIDED & INSTALLED UNDER SEPARATE
CONTRACT W/ OWNER'S FURNITURE VENDOR. CONTRACTOR TO
VERIFY LOCATIONS W/ OWNER & PROVIDE BLOCKING AS REQ'D
FOR FASTENING TOP & BOTTOM. SEE HEAD DETAIL H2/A501.
A1.06 OWNER PROVIDED & INSTALLED BANK EQUIPMENT AND/OR
MILLWORK BY OWNER'S VENDOR. VERIFY W/ VENDOR FOR ANY
ELECTRICAL REQUIREMENTS AND ALL DIMENSIONS.
A1.09 PROVIDE BLOCKING IN WALL FOR MILLWORK, EQUIPMENT &
SIGNAGE AS REQ'D. COORDINATE W/ ELEVATIONS.
A1.11 LINE OF SOFFIT ABOVE. SEE RCP ON A102 FOR MORE
INFORMATION
A1.14 DRINKING FOUNTAIN. REFER TO ACCESSORY MOUNTING HEIGHTS
LEGEND ON SHEET A601 FOR CLEARANCES.
A1.26 VAT SYSTEM, COORDINATE WITH OWNER'S EQUIPMENT VENDOR
AND ENGINEERING DRAWINGS. VAT TO BE RUN ABOVE AS
INDICATED BY DASHED LINE. COORDINATE WITH A100.
A1.27 TIE WALL AS CLOSE AS POSSIBLE TO THE STRUCTURE.
A1.28 (5) 12" DEEP SHELVING ON STANDARDS.
A1.29 INFILL WITH 1" INSULATED METAL PANEL.
A1.31 NEW IT RACK. REFER TO ELECTRICAL DRAWINGS.
SCALE:1 1/2" = 1'-0"2 WALL TO EXISTING WINDOW
Project
North
SCALE:1/4" = 1'-0"3 VAT AND ATM PLAN
SCALE:1/4" = 1'-0"4 ATM + AHD WALL ELEVATION
No. Date Description
10/15/2024 Bid and Permit Set
1 01/06/2025 Issued for City Comments
1
1