Loading...
HomeMy WebLinkAboutBuilding & Floor PlansDi e R e p a i r 7 ' 5 " " X 3 ' Po w e r B o x 1 4 ' X 5 ' LAB 40' X 24' MAINT 41' X 42' LATHE FAB TABLE MI L L DR I L L CA B I N E T ST E E L R A C K S. G R I N D E R BO L T B I N S CABINET BO L T B I N S 48'-4"37'-2"12'-2" XX X COURT 6 32'x57'-6" COURT 7 32'x57'-6" COURT 8 32'x57'-6" 61'-0" COURT 1 32'x61' COURT 2 32'x61' COURT 3 32'x61' COURT 4 32'x61' COURT 5 32'x61' 74'-71 8" 45 ' - 9 1 8" DINK COURT 11'x20' STORAGE LOCKERS - WITH PLASTIC LAMINATE TOP - 12" WIDE - 48 SHOWN BEVERAGE VENDING SNACK VENDING COUNTER W/ FREEZER BELOW BEER CART SNACK VENDING COUNTER W/ REFRIGERATOR BELOW 32 ' - 0 " FUTURE FRIDGE PRO DESK PR O S H O P ST O R A G E OF F I C E S T O R A G E PR I N T E R AD A CO U N T E R DE S K PO S ELEC / IT 160 SF 3'- 6 " O F 2 4 " ST O R A G E 7'- 0 " O F 2 4 " S T O R A G E 7'- 6 " O F 2 4 " ST O R A G E 3'-0" OF 24" STORAGE IT E Q U I P M E N T / S E C U R I T Y / E X I S T I N G EL E C T R I C A L 5'- 0 " O F 2 4 " ST O R A G E 6" 32 ' - 0 " 32 ' - 0 " 12 ' - 8 " 32 ' - 0 " 32 ' - 0 " 9' - 2 3 4" 32'-0" 57 ' - 6 3 4" 6' - 0 " 6' - 0 " 8'-6" 8'-6" 6' - 9 3 8" 6' - 9 3 8" 32'-0" 4'-8" 6'-0"6'-0" 6' - 9 1 4" 6' - 9 1 4" 6'-0"6'-0" 6' - 9 3 8" 106 102 10 5 109 STUDIO DANCE OPEN 102 STORAGE OPEN 105 OFFICE OPEN 101 STUDIO DANCE OPEN 103 LOUNGE STUDENT OPEN 109 STUDIO DANCE OPEN 107 DANCE BABY OPEN 106 CORRIDOR OPEN 104 CORRIDOR OPEN 108 CORRIDOR OPEN 110 EX 107 101 102 48 ' - 5 7 8" 50 ' - 0 " 100'-0" 21'-6" 24 ' - 1 1 12" 18 ' - 1 3 8" 28'-117 8" 24 ' - 2 3 4" 53'-10" 4'-012" 4'- 0 " 6'-0" 71 ' - 2 5 8" 28'-2" 45'-0" 35'-0" 78 ' - 0 " 6'-11 4"7'-73 8"35'-0" 10 4 ' - 9 " 24 ' - 7 5 8" 24'-31 2" WORKOUT ROOM WITH EQUIPMENT AND OPEN FLOOR AREA FOR EXERCISES - ALSO SPACE FOR PARENT VIEWING TENNIS COURT FOR DRILLS RECOVERY EQUIPMENT AREA ENTRY AREA COMMON RESTROOM AREA B.A.S.E.C. - TENNIS TENANT BUILD OUT 201 WEST CARMEL DRIVE CARMEL, INDIANA 46032 existing sprinkled building LIFE SAFETY NOTES OVERALL BUILDING PLAN - FIRST FLOOR NTS VICINITY MAP A000 COVER SHEET AND GENERAL PROJECT NOTES A001 LIFE SAFETY PLANS A002 VARIANCE AND CHAPTER 34 INFORMATION A003 VARIANCE AND CHAPTER 34 INFORMATION A004 ACCESSIBILITY A200 ARCHITECTURAL FLOOR PLANS E100 LIGHTING PLANS DRAWING INDEX A000 life safety / notes A. ALL WORK SHALL COMPLY WITH THE REQUIREMENTS OF THE EXISTING BUILDING CONSTRUCTION TYPE AS DEFINED BY SECTION 601 OF THE INDIANA BUILDING CODE. B. ALL WORK SHALL COMPLY WITH THE REQUIREMENTS OF ALL APPLICABLE STATE AND LOCAL BUILDING CODES. CONTRACTORS ARE RESPONSIBLE FOR VERIFYING THE CURRENT APPLICABLE BULIDING CODE(S) FOR THEIR RESPECTIVE SCOPE OF WORK. C. CONTRACTOR(S) SHALL VISIT THE WORK SITE PRIOR TO COMMENCEMENT. THE DRAWINGS CONTAINED HEREIN MAY NOT BE ALL INCLUSIVE OF EXISTING CONDITIONS OR NEW WORK REQUIREMENTS. CONTRACTOR(S) SHALL MAKE THEMSELVES FAMILIAR WITH THE WORK SITE IN THE FIELD IN ORDER TO BE FULLY AWARE OF THE REQUIREMENTS OF THE SCOPE OF WORK. D. FIELD VERIFY ALL DIMENSIONS AND MEASUREMENTS. INFORM THE GENERAL CONTRACTOR BEFORE BEGINNING ANY CONSTRUCTION IF EXISTING CONDITIONS PREVENT OBTAINING RESULTS AS SHOWN OR SPECIFIED. DO NOT SCALE DRAWINGS. NOTED DIMENSIONS TAKE PRECEDENCE. E. VERIFY EXISITNG CONDITIONS INDICATED ON THE DRAWINGS AND REPORT ANY DISCREPANCY THROUGH THE GENERAL CONTRACTOR TO SODA. F. THE GENERAL CONTRACTOR SHALL COORDINATE WITH THE OWNER REGARDING ALL ON-SITE ACTIVITIES; SUCH AS, BUT NOT LIMITED TO, WORK SCHEDULE, MATERIALS STORAGE AND HANDLING, DELIVERIES, ACCESS TO THE WORK SITE, TRAFFIC CONTROL, AND BUILDING/PUBLIC SAFETY PROCEDURES DURING CONSTRUCTION. THE CONTRACTOR SHALL ALSO COORDINATE WORK "BY OTHERS" WITH HIS/HER OWN ACTIVITIES AS NECESSARY TO EXECUTE THE OVERALL PROJECT SCOPE. G. THE GENERAL CONTRACTOR SHALL COORDINATE WITH THE LANDLORD, DAILY WORKING HOURS, WEEKEND HOURS AND HOURS THAT MAY BE WORKED PRIOR TO AND DURING HOLIDAYS. OWNER RESERVES THE RIGHT TO RESTRICT CONSTRUCTION TO NIGHTS AND WEEKENDS WHEN THAT CONSTRUCTION IS DEEMED TO INTERFERE WITH THE OPERATIONS OF ADJACENT TENANTS. H. FOR THOSE ITEMS TO BE ORDERED REQUIRING LEAD TIME. THE CONTRACTOR SHALL COOORDINATE THE PROJECTS SCHEDULE ACCORDINGLY AND COMMUNICATE TO THE OWNER, TENANT, AND SODA WHEN DECISIONS MUST BE RENDERED IN ORDER FOR THE CONTRACTOR TO MEET THE PROJECT SCHEDULE. THE OWNER, TENANT, OR DESIGNER/ARCHITECT IS NOT RESPONSIBLE FOR DELAYS RESULTING FROM THE CONTRACTORS FAILURE TO COMMUNICATE MATERIAL LEAD TIMES. I. SUBSTITUTIONS FOR SPECIFICALLY NAMED PRODUCTS WILL NOT BE ALLOWED WITHOUT PRIOR APPROVAL FROM THE DESIGNER. SUBMIT REQUESTS FOR SUBSTITUTIONS WITH APPROPRIATE SUPPORT INFORMATION TO THE DESIGNER. ALLOW REASONABLY SUFFICIENT TIME FOR THE DESIGNER TO REVIEW THE REQUEST AND RENDER A DECISION. J. SODA SHALL NOT HAVE CONTROL OVER, OR BE IN CHARGE OF, AND SHALL NOT BE RESPONSIBLE FOR A CONTRACTORS CONSTRUCTION MEANS, METHODS, SCHEDULES, SEQUENCES, OR SAFETY. THE CONTRACTORS SHALL BE RESPONSIBLE FOR MAINTAINING A SAFE ENVIRONMENT FOR WORKERS AND THE PUBLIC AT ALL TIMES. K. THE GENERAL CONTRACTOR SHALL ESTABLISH WITH THE LANDLORD CLEANUP PROCEDURES AND GUIDELINES TO BE FOLLOWED ON A DAILY BASIS IN ORDER TO CONDUCT BUSINESS IN A SAFE AND CLEAN ENVIRONMENT. L. THE GENERAL CONTRACTOR SHALL COORDINATE WITH THE LANDLORD AN AREA FOR STAGING OF CONSTRUCTION MATERIALS, EQUIPMENT, DUMPSTER AND PARKING CONSTRUCTION AND DELIVERY VEHICLES. THE USE OF EXISTING RESTROOM FACILITIES SHALL BE APPROVED BY THE LANDLORD. ONLY THOSE DESIGNATED AREAS SHALL BE USED BY CONSTRUCTION CREWS. M. CONTACT THE DESIGNER IMMEDIATELY IF, IN THE FIELD, CONFLICTS ARE DISCOVERED BETWEEN COMPONENTS OF DIFFERENT SYSTEMS THAT PREVENT THE INSTALLATION OF THOSE COMPONENTS AS INDICATED ON THE DRAWINGS. (I.E. WHERE EXISTING MECHANICAL DUCTWORK MAY PREVENT THE INSTALLATION OF LIGHT FIXTURES AS INDICATED ON THE CEILING PLAN). N. SODA IS NOT RESPONSIBLE FOR THE IDENTIFICATION, DISCOVERY, PRESENCE, HANDLING, REMOVAL, DISPOSAL OF, OR EXPOSURE TO ANY PERSONS, OF HAZARDOUS MATERIALS IN ANY FORM ON THE PROJECT SITE. O. PROVIDE FIRE-TREATED WOOD BLOCKING IN WALLS FOR ALL WALL HUNG ITEMS INCLUDING MILLWORK, WALL STOPS, CABINETRY, ETC. GENERAL PROJECT NOTES P. EXPEDITE PREPARARION AND SUBMITTAL OF ALL SHOP DRAWINGS TO ALLOW SUFFICIENT TIME FOR CHECKING, APPROVAL, ORDERING, FABRICATING AND DELIVERY OF MATERIALS AND EQUIPMENT. Q. ENSURE THAT ALL MATERIALS AND LABOR ARE IN ACCORDANCE WITH THE BEST QUALITY STANDARDS OF EACH RESPECTIVE TRADE WHETHER SPECIFIED OR NOT. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR ENSURING THAT ALL WORK IS IN ACCORDANCE WITH ALL FEDERAL, STATE, AND LOCAL BUILDING CODES, AND STANDARDS FOR GENERAL, MECHANICAL, AND ELECTRICAL CONSTRUCTION. R. REVIEW AND COORDINATE ALL NEW WORK AND EXISTING CONDITIONS WITH ALL OTHER TRADES. FIELD WORK ORDERS AND CHANGE ORDERS WILL NOT BE APPROVED FOR ANY CONDITIONS OR CONFLICTS THAT COULD HAVE BEEN ACCOUNTED FOR BY THE BIDDER DURING PRE-BID FIELD INSPECTION AND AFTER AWARD OF CONTRACT. S. REPAIR GYPSUM WALLBOARD WHERE DEMOLITION HAS OCCURRED AT REMAINING WALLS. REPAIR ANY GYPSUM WALLBOARD DAMAGED BY DEMOLITION. PROVIDE EXPANSION JOINTS IN DRYWALL WHERE NEW WALLS MEET OR ADJOIN TO EXISTING CORE WALLS. T. PATCH ALL GYPSUM WALLBOARD AT AREAS OF ELECTRICAL, DATA AND SWITCH DEVICES BEING REMOVED. PATCH HOLE WITH DRYWALL, TAPE, SPACKLE AND PREPARE FOR FINISH. U. WHEN REQUIRED BY STATE BUILDING CODE, THE CONTRACTOR(S) SHALL PROVIDE DESIGN/BUILD DRAWINGS FOR MECHANICAL, ELECTRICAL, PLUMBING, OR FIRE SUPPRESSION. DRAWINGS SHALL BE CERTIFIED BY A LICENSED ENGINEER AND SUBMITTED BY THE CONTRACTOR FOR STATE DESIGN REVIEW. V. ALL EQUIPMENT AND/OR FIXTURES SHALL BE INSTALLED IN STRICT ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS OR INSTRCUTIONS. W. EXECUTE A THOROUGH FINAL CLEAN AND INSPECTION OF THE SPACE UPON COMPLETION OF THE PROJECT. ALL SURFACES, FIXTURES AND EQUIPMENT SHALL BE CLEAN AND THE SPACE SHALL BE TURNED OVER TO THE OWNER IN A CONDITION THAT REPRESENTS THE HIGHEST LEVEL OF CARE AND PROFESSIONALISM. ENSURE ALL GENERAL CONTRACTOR INSTALLED APPLIANCES WORK AND DO NOT LEAK. X. PROVIDE TO THE OWNER ALL OPERATION AND/OR MAINTENANCE MANUALS OR INSTRUCTIONS FOR ALL EQUIPMENT AND SYSTEMS AT THE COMPLETION OF THE PROJECT. Y. ALL PLAN DIMENSIONS ARE FROM FACE OF EXISTING FINISH FACE TO FACE OF NEW STUD WALL , OR FACE TO FACE OF NEW STUD WALL. DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS GOVERN. Z. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE REQUIREMENTS REGARDING LOCAL PLAN REVIEW, PERMITS, INSPECTIONS, AND FEES. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR SUBMITTING ALL REQUIRED DRAWINGS AND SUPPORTING DOCUMENTS TO THE LOCAL BUILDING OFFICIAL AND/OR PERMIT DEPARTMENT. ALL REQUIRED LOCAL PERMIT FEES SHALL BE PAID BY THE GENERAL CONTRACTOR UNLESS STIPULATED OTHERWISE IN THE OWNER/CONTRACTOR AGREEMENT. AA. FIRE SEAL ALL PENETRATIONS THROUGH RATED WALLS, FLOORS, AND CEILINGS WITH APPROVED FIRE-RATED CAULK AS DIRECTED BY LOCAL JURISDICTIONS. AB. WHERE STRUCTURAL BEAMS, DUCTWORK, ETC. PENETRATE SOUND OR FIRE RATED PARTITIONS, GYPSUM WALLBOARD WALL TO BE SCRIBED TO FIT TIGHT, CAULKED AND FIRE DAMPERED IF REQUIRED. AC. CONTRACTOR TO ALLOW FOR UNLEVEL FLOOR CONDITIONS, ALL EXISTING FLOOR AND WALL SUBSTRATES SHALL BE LEVELED AND PATCHED AS REQUIRED TO RECEIVE NEW CONSTRUCTION AND FINISHES. ADJUST DOORS AND FRAMES AS REQUIRED. AD. FIRE EXTINGUISHERS: CONTRACTOR TO ENSURE ALL NEW AND EXISTING FIRE EXTINGUISHERS ARE INSTALLED ACCORDING TO NFPA 10. COORDINATE WITH OWNER/LANDLORD ON EXTINGUISHER TYPE AND HOUSING. MAXIMUM TRAVEL DISTANCE OF 75 FEET FROM ANY POINT TO A VISIBLE EXTINGUISHER. North SCOPE OF WORK THE INTENT OF THIS PROJECT IS TO RENOVATE EXISTING VACANT SPACE WHICH WAS PREVIOUSLY APPROVED UNDER PROJECT NUMBER - 440809 TO BE ASSEMBLY OCCUPANCY. THIS TENANT WILL HAVE DANCE STUDIO CLASS SPACE - STUDENT LOUNGE - SMALL OFFICE - WAITING AREA AND STORAGE ROOM - NO PLUMBING OR MECHANICAL HVAC WORK WILL BE NECESSARY 201 WEST CARMEL DRIVE A.PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER NEMA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS CONNECTED TO AN EMERGENCY POWER SOURCE ARE REQUIRED IF THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN ON PLAN ARE FOR REFERENCE ONLY. B.THE DESIGN/BUILD CONTRACTOR SHALL COMPLY WITH THE INDIANA BUILDING CODE ANDTHE INDIANA FIRE CODE AND ALL OTHER APPLICABLE LAWS, CODES, RULES, AND REGULATIONS THAT APPLY TO DESIGN AND INSTALLATION OF FIRE SPRINKLER/ FIRE SUPPRESSION SYSTEMS. C.PROVIDE NEW OR RELOCATE EXISTING FIRE SPRINKLER HEADS AS REQUIRED. PROVIDE MISSING COVER/ESCUTCHEON PLATES FOR SPRINKLER HEADS WHERE APPLICABLE. FIELD VERIFY EXISTING CONDITIONS PRIOR TO THE START OF WORK. ARCHITECT: SWANSON OFFICE OF DESIGN + ARCHITECTURE 311 WOODLAND LANE CARMEL, IN 46032 [P] 317.324.8855 TENANT: OWNER: PERFORMER'S EDGE 201 WEST CARMEL DRIVE CARMEL IN, 46032 BUILDING CODE: INDIANA BUILDING CODE 2014 (INTERNATIONAL BUILDING CODE 2012 WITH INDIANA AMENDMENTS) MECHANICAL CODE: INDIANA MECHANICAL CODE 2014 (INTERNATIONAL MECHANICAL CODE 2012 WITH INDIANA AMENDMENTS) ELECTRICAL CODE: INDIANA ELECTRICAL CODE 2009 (NATIONAL ELECTRICAL CODE 2008 WITH INDIANA AMENDMENTS) PLUMBING CODE: INDIANA PLUMBING CODE 2012 (INTERNATIONAL PLUMBING CODE 2006) FIRE CODE: INDIANA FIRE CODE 2014 (INTERNATIONAL FIRE CODE 2012 WITH INDIANA AMENDMENTS) ENERGY CODE: INDIANA ENERGY CONSERVATION CODE 2010 (ASHRAE 90.1-2007 WITH INDIANA AMENDMENTS) FUEL GAS CODE: INDIANA FUEL GAS CODE 2014 (INTERNATIONAL FUEL GAS CODE 2006 WITH INDIANA AMENDMENTS) ACCESSIBILITY CODE: INDIANA BUILDING CODE 2014, CHAPTER 11 ICC A117.1 ACCESSIBLE USABLE BUILDINGS AND FACILITIES, 2009 EDITION. INDIANA ADMINISTRATIVE CODE 675 IAC 13-2.6-13 APPLICABLE BUILDING CODES THE FOLLOWING CODES AND REGULATIONS ARE CURRENTLY ADOPTED BY THE STATE OF INDIANA AT THE TIME THE BUILDING PERMIT IS APPLIED FOR:ALL WORK UNDER THIS CONTRACT SHALL COMPLY WITH THE PROVISIONS OF THE SPECIFICATIONS & DRAWINGS AND SHALL SATISFY ALL APPLICABLE CODES, ORDINANCES, A.D.A., AND REGULATIONS OF ALL GOVERNING BODIES INVOLVED. ALL PERMITS AND LICENSES NECESSARY FOR THE PROPER EXECUTION OF THE WORK SHALL BE SECURED AND PAID FOR BY THE CONTRACTOR INVOLVED. North AREA TO BE ACCESSED BY TENANT B.A.S.E.C. TENNIS 8,772 S.F. FIRE SPRINKLER SYSTEM NOTE: CONTRACTOR TO COORDINATE REWORK OF EXISTING SPRINKLER SYSTEM TO ACCOMODATE NEW ROOM - DESIGN BUILD CONTRACTOR TO SUBMIT DESIGN OF MODIFICATIONS TO STATE OF INDIANA AND CITY OF CARMEL AS REQUIRED COPYRIGHT: SODA, LLC expressly reserves the common law copyright and other property rights in these plans. These plans are not to be reproduced in any form or manner, nor assigned to any third party, without first obtaining the expressed permission and consent of SODA, LLC. B. A . S . E . C . T E N N I S 20 1 W E S T C A R M E L D R I V E CA R M E L , I N 4 6 0 3 2 C COPYRIGHT SODA, LLC . date 05.05.24 PERMIT ISSUE issue Ca r m e l , I N t j @ s w a n s o n o f f i c e . c o m t : 3 1 7 . 3 2 4 . 8 8 5 5 N O S N AWSJSAMOHT CRA TCTI AR11800182 T ERED SIGER A N AIDNI H No. STATE OF E JAMES 201 LLC 1030 S. RANGELINE RD #300 CARMEL IN, 46032 [P] 317.488.87373 Die R e p a i r 7 ' 5 " " X 3 ' Po w e r B o x 1 4 ' X 5 ' LAB 40' X 24' MAINT 41' X 42' LATHE FAB TABLE MI L L DR I L L CA B I N E T ST E E L R A C K S. G R I N D E R BO L T B I N S CABINET BO L T B I N S ELEVATOR 48'-4"37'-2"12'-2" EXISTING WOMENS RESTROOM EXISTING MENSRESTROOM XX X COURT 6 32'x57'-6" COURT 7 32'x57'-6" COURT 8 32'x57'-6" 61'-0" COURT 1 32'x61' COURT 2 32'x61' COURT 3 32'x61' COURT 4 32'x61' COURT 5 32'x61' DINK COURT 11'x20' STORAGE 6' - 0 " LOCKERS - WITH PLASTIC LAMINATE TOP - 12" WIDE - 48 SHOWN BEVERAGE VENDING SNACK VENDING COUNTER W/ FREEZER BELOW BEER CART SNACK VENDING COUNTER W/ REFRIGERATOR BELOW 32 ' - 0 " FUTURE FRIDGE PRO DESK PR O S H O P ST O R A G E OF F I C E S T O R A G E PR I N T E R AD A CO U N T E R DE S K PO S ELEC / IT 160 SF 3'- 6 " O F 2 4 " ST O R A G E 7'- 0 " O F 2 4 " S T O R A G E 7'- 6 " O F 2 4 " ST O R A G E 3'-0" OF 24" STORAGE IT E Q U I P M E N T / S E C U R I T Y / E X I S T I N G EL E C T R I C A L 5'- 0 " O F 2 4 " ST O R A G E 6" 32 ' - 0 " 32 ' - 0 " 12 ' - 8 " 32 ' - 0 " 32 ' - 0 " 9' - 2 3 4" 32'-0" 57 ' - 6 3 4" 6' - 0 " 6' - 0 " 8'-6" 8'-6" 6' - 9 3 8" 6' - 9 3 8" 32'-0" 4'-8" 6'-0"6'-0" 6' - 9 1 4" 6' - 9 1 4" 6'-0"6'-0" 6' - 9 3 8" 106 102 10 5 109 STUDIO DANCE OPEN 102 STORAGE OPEN 105 OFFICE OPEN 101 STUDIO DANCE OPEN 103 LOUNGE STUDENT OPEN 109 STUDIO DANCE OPEN 107 DANCE BABY OPEN 106 CORRIDOR OPEN 104 CORRIDOR OPEN 108 CORRIDOR OPEN 110 EX 107 101 102 48 ' - 5 7 8" 50 ' - 0 " 100'-0" 21'-6" 24 ' - 1 1 1 2" 18 ' - 1 3 8" 28'-117 8" 24 ' - 2 3 4" 53'-10" 4'-01 2" 4' - 0 " 6'-0" 71 ' - 2 5 8" 28'-2" 45'-0" 35'-0" 78 ' - 0 " 6'-11 4"7'-73 8"35'-0" 10 4 ' - 9 " 24 ' - 7 5 8" 24'-31 2" WORKOUT ROOM WITH EQUIPMENT AND OPEN FLOOR AREA FOR EXERCISES - ALSO SPACE FOR PARENT VIEWING TENNIS COURT FOR DRILLS RECOVERY EQUIPMENT AREA ENTRY AREA COMMON RESTROOM AREA 8'-0" GYP EXISTING WOMENS RESTROOM EXISTING MENS RESTROOM XX X SNACK VENDING SNACK VENDING FUTURE FRIDGE ST O R A G E PR I N T E R ELEC / IT 160 SF 3' - 6 " O F 2 4 " ST O R A G E 7' - 0 " O F 2 4 " S T O R A G E 7' - 6 " O F 2 4 " ST O R A G E 3'-0" OF 24" STORAGE IT E Q U I P M E N T / S E C U R I T Y / E X I S T I N G EL E C T R I C A L 5' - 0 " O F 2 4 " ST O R A G E 102 10 5 109 STUDIO DANCE OPEN 102 STORAGE OPEN 105 OFFICE OPEN 101 STUDIO DANCE OPEN 103 LOUNGE STUDENT OPEN 109 STUDIO DANCE OPEN 107 CORRIDOR OPEN 104 CORRIDOR OPEN 108 107 101 102 48 ' - 5 7 8" 50 ' - 0 " 18 ' - 1 3 8" 28'-117 8" 24 ' - 2 3 4" 53'-10" 4'-01 2" 4' - 0 " 6'-0" 71 ' - 2 5 8" 28'-2" 45'-0" 35'-0" 78 ' - 0 " 6'-11 4"7'-73 8"35'-0" 10 4 ' - 9 " 24 ' - 7 5 8" 24'-31 2" WORKOUT ROOM WITH EQUIPMENT AND OPEN FLOOR AREA FOR EXERCISES - ALSO SPACE FOR PARENT VIEWING TENNIS COURT FOR DRILLS RECOVERY EQUIPMENT AREA ENTRY AREA COMMON RESTROOM AREA 4' - 8 " 7'-4" HOISTWAY PROPOSED ELEVATOR 15'-0" 35 8" 14 ' - 3 " 4'-5" 37 ' - 1 1 1 8" 8'-8" 14 ' - 1 0 " 21'-3" 17'-23 8" 8'-31 8"3'-0" 1'-6" CONFERENCE VARIES ACT 201 OPEN OFFICE 1 8'-0" ACT 202 IT OFFICE 8'-0" ACT 203 MECH 8'-0" ACT 204 WOMEN 8'-0" ACT 205 MEN 8'-0" ACT 206 TRAINING 7'-5" ACT 208 STORAGE 8'-0" ACT 209 MECH 8'-0" ACT 210 MECH 8'-0" ACT 211 4' - 3 " 5' - 9 " HO I S T W A Y 7'- 9 " 8" 8" 358" 35 8" 16'-41 4" 12 ' - 0 1 2" 21'-111 2" 47 ' - 8 1 2" 358" 21'-103 8" 23'-117 8" 47 8" 14'-75 8" 47 8" OFFICE 7'-5" ACT 212 OFFICE 7'-5" ACT 213 OFFICE 7'-5" ACT 214 OFFICE 7'-5" ACT 215 OFFICE 7'-5" ACT 216 OFFICE 7'-5" ACT 217 CORRIDOR 7'-5" ACT 218 8'-51 2" 6'-6"35 8" 358" 8' - 4 " 358" 6"6'-6" 26'-11" 1'- 2 1 2"7' - 2 " 9'-6" OVERALL BUILDING CODE INFORMATION SCOPE OF WORK1 REMODEL OF EXISTING SPACE - NEW TENANT - SEE TENANT SPECIFIC INFORMATION OCCUPANCY CLASSIFICATION2 RECLASSIFIED AS A3, B - BUSINESS - SEE SHEET A002 AND A003 FOR CHAPTER 34 REVIEW INFO AND CDR 3 PERMITTED PER VARIANCE - PROJECT NUMBER 440809CHANGE OF OCCUPANCY CLASS? 7 BUILDING AREAS (SF) 8 9,496 SF REMODELINGTOTAL PROJECT AREA 9 OCCUPANCY CALCULATIONS B OCCUPANCY SPACE AREA SF PER OCCUPANT OCCUPANT LOAD FIRST FLOOR 6,723 SF 100 68 10 EGRESS WIDTHS 12 SPRINKLER SYSTEM (YES/NO)YES - EXISTING TO REMAIN SECOND FLOOR 1005,237 SF LIFE SAFETY NOTES 1.PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER NEMA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS CONNECTED TO AN EMERGENCY POWER SOURCE ARE REQUIRED IF THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN ON PLAN ARE FOR REFERENCE ONLY 2.PROVIDE ALARM NOTIFICATION APPLIANCES (HORN/STROBES) EMERGENCY SPEAKERS, SMOKE DETECTORS, FORE PULLS, AND ANY OTHER REQUIRED ALARM AND DETECTION SYSTEMS AS NECESSARY TO MEET ALL APPLICABLE CODES (INTERNATIONAL BUILDING CODE, INTERNATIONAL FIRE CODE, NFPA). 3.FIRE PROTECTION WORK IS TO BE PROVIDED BY DESIGN/BUILD SERVICES UNDER THE GENERAL CONTRACT. PROVIDE A COMPLETE WORKING SYSTEM. SODA IS NOT RESPONSIBLE FOR THE DESIGN, INSTALLATION, OR RENOVATION OF THE FIRE SPRINKLER SYSTEM. 4.THE FIRE PROTECTION CONTRACTOR SHALL GENERATE ALL REQUIRED DRAWINGS, AND SHALL FILE THOSE DRAWINGS, AND RELATED DOCUMENTS, WITH THE STATE AND LOCAL AUTHORITIES HAVING JURISDICTION OVER THE PROJECT. 5.FIRE EXTINGUISHERS: CONTRACTOR TO ENSURE ALL NEW AND EXISTING FIRE EXTINGUISHERS ARE INSTALLED ACCORDING TO NFPA 10. COORDINATE WITH OWNER/LANDLORD ON EXTINGUISHER TYPE AND HOUSING.MAXIMUM TRAVEL DISTANCE OF 75 FEET FROM ANY POINT TO VISIBLE EXTINGUISHER. GENERAL NOTES APPLICABLE BUILDING CODES ALL WORK UNDER THIS CONTRACT SHALL COMPLY WITH THE PROVISIONS OF THE SPECIFICATIONS & DRAWINGS AND SHALL SATISFY ALL APPLICABLE CODES, ORDINANCES, A.D.A., AND REGULATIONS OF ALL GOVERNING BODIES INVOLVED. ALL PERMITS AND LICENSES NECESSARY FOR THE PROPER EXECUTION OF THE WORK SHALL BE SECURED AND PAID FOR BY THE CONTRACTOR INVOLVED. THE FOLLOWING CODES AND REGULATIONS ARE CURRENTLY ADOPTED BY THE STATE OF INDIANA AT THE TIME THE BUILDING PERMIT IS APPLIED FOR: BUILDING CODE: INDIANA BUILDING CODE 2014 (INTERNATIONAL BUILDING CODE 2012 WITH INDIANA AMENDMENTS) MECHANICAL CODE: INDIANA MECHANICAL CODE 2014 (INTERNATIONAL MECHANICAL CODE 2012 WITH INDIANA AMENDMENTS) ELECTRICAL CODE: INDIANA ELECTRICAL CODE 2009 (NATIONAL ELECTRICAL CODE 2008 WITH INDIANA AMENDMENTS) PLUMBING CODE: INDIANA PLUMBING CODE 2012 (INTERNATIONAL PLUMBING CODE 2006) FIRE CODE: INDIANA FIRE CODE 2014 (INTERNATIONAL FIRE CODE 2012 WITH INDIANA AMENDMENTS) ENERGY CODE: INDIANA ENERGY CONSERVATION CODE 2010 (ASHRAE 90.1-2007 WITH INDIANA AMENDMENTS) FUEL GAS CODE: INDIANA FUEL GAS CODE 2014 (INTERNATIONAL FUEL GAS CODE 2006 WITH INDIANA AMENDMENTS) ACCESSIBILITY CODE: INDIANA BUILDING CODE 2014, CHAPTER 11 ICC A117.1 ACCESSIBLE USABLE BUILDINGS AND FACILITIES, 2009 EDITION. INDIANA ADMINISTRATIVE CODE 675 IAC 13-2.6-13 CATEGORY STRUCTURAL FRAME EXTERIOR BEARING WALLS EXTERIOR NON-BEARING WALLS INTERIOR BEARING WALLS INTERIOR NON-BEARING WALLS (PARTITIONS) FLOOR / FLOOR-CEILING ASSEMBLY ROOFS / ROOF-CEILING ASSEMBLY EXIT ACCESS CORRIDORS EXIT STAIR ENCLOSURES SHAFT ENCLOSURES (ELEVATOR / MECHANICAL) MIN. FIRE RESISTANCE 0 HOUR - TABLE 601 0 HOUR - TABLE 601 / 602 0 HOUR - TABLE 601 / 602 0 HOUR - TABLE 601 0 HOUR - TABLE 601 0 HOUR - TABLE 601 0 HOUR - TABLE 601 0 HOUR - TABLE 1017.1 (WITH SPRINKLER) 0 HOUR - SECTION 1020.1 (LESS THAN 4 STORIES) 0 HOUR - SECTION 707.4 (LESS THAN 4 STORIES) EXISTING BUILDING B OCC. FIRST TOTAL SECOND EXISTING EAST BUILDING A3 OCC. 6,723 5,237 11,960 38,729 -- 38,729 NUMBER OF REQ. EXITS 2 11 II-B (FULLY SPRINKLERED)CONSTRUCTION TYPE 53 2 SPACE INCHES PER OCCUPANT INCHES REQUIRED FIRST FLOOR .15 11 SECOND FLOOR .15 INCHES PROVIDED 144 (EXCEED) 8 72 (EXCEED) OCCUPANT LOAD 68 53 FIRE RESISTIVE REQUIREMENTS - TYPE II-B A3 OCCUPANCY FIRST FLOOR - WEST BUILDING 20,003 SF 401 250 B OCCUPANCY FIRST FLOOR WEST .15 61 108 (EXCEED)401 A3 OCCUPANCY FIRST FLOOR .15 5 108 (EXCEED)31S1 OCCUPANCY 4 81,592 SFGROSS BUILDING AREA 5 9,496 SF FIRST FLOORREMODEL AREA (INC. IN GROSS) 6 ALLOWABLE AREA ALLOWABLE AREA CALCULATIONS NOT REQUIRED, NO ADDITIONAL SQUARE FOOTAGE ADDED - REFER TO VARIANCE - PROJECT NUMBER 440809 EXISTING FIRE EXTINGUISHERS TO REMAIN WITH NEW EXTINGUISHERS ADDED TO MEET 2012 IFC WITH 2014 INDIANA AMENDMENTS A001 code / egress EXIT EXIT EXIT EXIT EX I T EX I T EXIT EX I T EXIT EX I T EX I T North Overall Building Life Safety First Floor Plan 1/32" = 1'-0" 01A A001 FIRST FLOOR - EAST BUILDING 38,729 SF 50 North Life Safety - B.A.S.E.C. TENNIS 1/16" = 1'-0" 02 A001 EXIT FE LEGEND EXIT SIGNAGE FIRE EXTINGUISHER TRAVEL DISTANCE FE S1 OCCUPANCY THIS AREA IS S-1 THE TENNIS COURT OPERATIONS AREA SEE 02/A001 775 3 300 31 9,263 SF 1 EXISTING EAST BUILDING S1 OCC. EXISTING WEST BUILDING A3 OCC. 20,003 9,263 20,003 9,263 FIRST FLOOR - EAST BUILDING FIRST FLOOR EAST .15 116 144 (EXCEED)775 EXIT 13 MAXIMUM TRAVEL DISTANCE 250'-0" TENANT SPACE CALCULATIONS SPRINKLER SYSTEM (YES/NO)YES - EXISTING TO REMAIN II-B (FULLY SPRINKLERED)CONSTRUCTION TYPE TENANT SQUARE FEET 9,496 SF BUILDING DESCRIPTION OCCUPANCY / EGRESS CHAPTER 10 - OCCUPANT LOAD PER TABLE 1004.1.2 A-3 OCCUPANCY STUDIO(S) 6,311 SF CALCULATED AT 50 SF / PERSON STUDENT LOUNGE 694 SF CALCULATED AT 15 SF / PERSON WAITING AREA 581 SF CALCULATED AT 7 SF / PERSON S1 OCCUPANCY FIRST FLOOR @350 SF WITH 300 sf / PERSON Gross S.F. = 9,496 SF 127 PERSON(S) 46 PERSON(S) 83 PERSON(S) + 2 PERSON(S) = 258 PERSONS TOTAL TABLE 1005.1 .20 INCHES PER PERSON FOR STAIRWAYS .15 INCHES PER PERSON FOR OTHER COMPONENTS EXIT DOORS - 258 PERSONS x .15; 39" MIN TOTAL REQUIRED = 72" PROVIDED 164' 105' 90' FE FE EXIT SECONDARY EGRESS PATH 40 OCCUPANTS 39 OCCUPANTS 28 OCCUPANTS EXIT DOOR TO HAVE PANIC EXIT DEVICE HARDWARE - PROVIDE EXIT LIGHT WITH EMERGENCY LIGHTING AT INTERIOR AND EXTERIOR PROVIDE DIRECTIONAL EXIT SIGN EXISTING HS EXISTING HSEXISTING HS EXISTING HS EXISTING HS EXISTING HS NEW HS NEW HS TWO HEADED EMERGENCY LIGHT W/ BATTERY FIRE HORN STROBE DEVICE PROVIDE DIRECTIONAL EXIT SIGN COPYRIGHT: SODA, LLC expressly reserves the common law copyright and other property rights in these plans. These plans are not to be reproduced in any form or manner, nor assigned to any third party, without first obtaining the expressed permission and consent of SODA, LLC. B. A . S . E . C . T E N N I S 20 1 W E S T C A R M E L D R I V E CA R M E L , I N 4 6 0 3 2 C COPYRIGHT SODA, LLC . date 05.05.24 PERMIT ISSUE issue Ca r m e l , I N t j @ s w a n s o n o f f i c e . c o m t : 3 1 7 . 3 2 4 . 8 8 5 5 NOT F O R CO N S T R U C T I O N N O S N AWSJSAMOHT CRA TCTI AR11800182 T ERED SIGER A N AIDNI H No. STATE OF E North Overall Building Life Safety Second Floor Plan 1/32" = 1'-0" 01B A001 EXISTING WOMENS RESTROOM EXISTING MENS RESTROOM XX X SNACK VENDING SNACK VENDING FUTURE FRIDGE ELEC / IT 160 SF 7' - 0 " O F 2 4 " S T O R A G E 3'-0" OF 24" STORAGE IT E Q U I P M E N T / S E C U R I T Y / E X I S T I N G EL E C T R I C A L 5' - 0 " O F 2 4 " ST O R A G E 101 48 ' - 5 7 8" 50 ' - 0 " 18 ' - 1 3 8" 28'-117 8" 24 ' - 2 3 4" 53'-10" 4'-01 2" 4' - 0 " 6'-0" 71 ' - 2 5 8" 28'-2" 45'-0" 35'-0" 78 ' - 0 " 6'-11 4"7'-73 8"35'-0" 10 4 ' - 9 " 24 ' - 7 5 8" 24'-31 2" WORKOUT ROOM WITH EQUIPMENT AND OPEN FLOOR AREA FOR EXERCISES - ALSO SPACE FOR PARENT VIEWING TENNIS COURT FOR DRILLS RECOVERY EQUIPMENT AREA ENTRY AREA COMMON RESTROOM AREA A200 floor plan North B.A.S.E.C. Tennis - Floor Plan 1/8" = 1'-0" 01 A200 3 W1 W1 W1 W1 W1 W1 16 ' 16 ' 16' 16' 16 ' 16 ' D 88 4 4 W1 16' 16 ' W1 COPYRIGHT: SODA, LLC expressly reserves the common law copyright and other property rights in these plans. These plans are not to be reproduced in any form or manner, nor assigned to any third party, without first obtaining the expressed permission and consent of SODA, LLC. B. A . S . E . C . T E N N I S 20 1 W E S T C A R M E L D R I V E CA R M E L , I N 4 6 0 3 2 C COPYRIGHT SODA, LLC . date 05.05.24 PERMIT ISSUE issue Ca r m e l , I N t j @ s w a n s o n o f f i c e . c o m t : 3 1 7 . 3 2 4 . 8 8 5 5 NOT F O R CO N S T R U C T I O N N O S N AWSJSAMOHT CRA TCTI AR11800182 T ERED SIGER A N AIDNI H No. STATE OF E GENERAL NOTES A. ALL DIMENSIONS ARE FROM CENTERLINE OF COLUMN GRID OR FACE OF STUD. ANY DIMENSIONS NOT SHOWN OR DEEMED QUESTIONABLE ARE TO BE VERIFIED WITH ARCHITECT. DO NOT SCALE DRAWINGS. B. SEE WALL TYPE LEGEND FOR WALL CONSTRUCTION. C. PROVIDE WOOD BLOCKING SUPPORT AS REQUIRED. D. COORDINATE WORK OF THIS TRADE WITH OTHER TRADES. E. ALL WORK SHALL BE PERFORMED IN STRICT COMPLIANCE WITH ALL APPLICABLE CODES, LAWS AND ORDINANCES. F. CONTACT RESPECTIVE UTILITY COMPANY FOR EXACT LOCATION OF SERVICES PRIOR TO START OF CONSTRUCTION. PROTECT EXISTING SERVICE DURING CONSTRUCTION. G. NOT USED. H. CAULK JUNCTURES BETWEEN DIFFERENT MATERIALS (I.E. STOREFRONT AND GYPSUM BOARD). I.EACH CONTRACTOR SHALL PROVIDE ALL BARRICADES, ETC. AS REQUIRED BY LAW, CODE OR ORDINANCE AND AS OTHERWISE REQUIRED. J. ALL STEEL STUDS ARE TO BE BRACED ACCORDING TO MANUFACTURER'S LIMITING HEIGHT L/ OVER 240. K. REMOVE ALL TRASH AND DEBRIS FROM THE JOB SITE DAILY. L. ALL METAL STUD WALLS WHICH EXTEND TO DECK SHALL BE CONSTRUCTED WITH A CONTINUOUS SLIP TRACK AT TOP OF WALL. TRACK SHALL BE SIZED TO ALLOW FOR MINIMUM DECK DEFLECTION OF 1/2". M. PROVIDE SURFACE MOUNTED FIRE EXTINGUISHERS AS REQUIRED BY LOCAL CODE. WALL TYPES FLOOR PLAN KEYED NOTES FIRE EXTINGUISHER LOCATION VIEWING WINDOW - REFER TO A400 EXISTING EGRESS DOOR WITH PANIC EXIT HARDWARE AND ALARM AREA OUSIDE PROJECT SCOPE OF WORK EXISTING BUILDING POWER WITH FENCE ENCLOSURE BY OWNER EXISTING SKYLIGHT LOCATIONS SHOWN DASHED RECEPTION COUNTER TO BE ADA COMPLAINT IN HEIGHT AND FRONT ACCESSIBILITY - REFER TO DETAIL 04/A400 EXISTING RESTROOM ACCESSIBLE TO DANCE STUDIO EXISTING WALL CONSTRUCTION TO REMAIN NEW WALL CONSTRUCTION TO DECK TO ALIGN WITH EXISTING WALL FINISHES THIS AREA: LVT FLOORING SELECTED BY OWNER VINYL BASE TO COORDINATE WITH FLOOR FINISH PAINTED WALLS CEILING OPEN FINISHES THIS AREA: SPORTS FLOOR AS DETERMINED BY OWNER VINYL BASE TO COORDINATE WITH FLOOR FINISH PAINTED WALLS CEILING OPEN 1 2 3 4 5 6 W 3 5/8" METAL STUD FRAMING WITH 5/8" GYPSUM WALLBOARD EACH SIDE W/ MINERAL WOOL SOUND INSULATION IN EACH CAVITY. ALTERNATE TO USE FIRE RETARDENT TREATED WOOD FRAMING 6" METAL STUD FRAMING WITH 5/8" GYPSUM WALLBOARD EACH SIDE W/ MINERAL WOOL INSULATION IN EACH CAVITY. ALTERNATE TO USE FIRE RETARDENT TREATED WOOD FRAMING * ALL WALL TYPES SHALL BE W1 UNLESS NOTED OTHERWISE. * WALL THICKNESS INDICATED IS ANTICIPATED - METAL STUD FRAMING SIZE, GAUGE, AND SPACING TO BE DESIGNED BY FRAMING CONTRACTOR TO MEET 5 PSF AT L/ OVER 240 - PROVIDE CLIPS BRIDGING AND ATTACHMENT DETAILS AS REQUIRED - SUBMIT ENGINEERED SHOP DRAWINGS W1 W2 4 7 / 8 " 7 1 / 4 " WALL HEIGHTS A. ALL WALLS EXTEND TO DECK IF NOT NOTED OTHERWISE: WHERE WALLS ARE FRAMED TO DECK OR STRUCTURE ABOVE PROVIDE SLIP TRACK CONDITION FOR MOVEMENT OF ROOF. WALLS TO 16' ABOVE FINISHED FLOOR16' WALLS TO DECK ABOVED 7 8 * 9 10 11 12