June 20, 2007
Dennis Reagan
Menitt Conhcting, Ino.
900 5. 51. Rd. 39
Lebanon, IN 46052
Re: Lincolnshire Lot 39
Oear Dennis,
It is my understanding that the bottom offo6ting e)(C8vation'a! the lot referenced above is not level. Y;ou
requested my opinion as to the appropriateness of using f10wable fill to level the bottom of excavation.
Flowable fill may be used to level the bottom of the wall fooling excavation with the following
stipulations. First, the existing soil at the bottom of the current excavation must be of good quality and
provide the required soil bearing capacity (2,000 psf unless otherwise noted on the construction
documents). Second, the bottom of excavation must be clean and free of loose dirt and debris priorito
the placement of the f10wable fill. Fin_fly, the fIowable fill mUl;:t also provide at least the required sbil
bearing capacity (2,000 psf unless otherwise noted).
I appreciate the opportunity to be of service and please contact me if you have any further questions or
comments, i
,
My opinion, stated herein, is limited to tho~,~,sues.discUSsed. Other issues regarding the constructioh,
if any, are beyond the scope of this.Ji~tter '" '",'..''' . '.. .. '.
Regards,
~SChwa~E;~. ..
. n D. Schwarz, PE . '.
Struolural Engineer .' .
""".,'
:':'.
. .:"...
;.
I",'.
OS/20/2007 15:22
17085755809
PAGE 01
~
MERRITT
CONTRACTING. INC.
900 South SI. Rd. 39
Lebanon, Indians 46062
Phon.; 765-483-0947
Fax: 708.575-6809
Fax
To, Office of Bldg Commission of Carmel
Attn:Jim
- Jami/Merritt Contracting
F_ 317-571-2499
'ag"", 2
Date, 6/20
Re: 39 Lincolnshire
Per your request, here is a copy of the engineers letter regarding fJowable fill.
Thanks