HomeMy WebLinkAbout07060127 Site Plan
'.-----.
~
'.
This Plot PIon Prepared For: R.H. of Indiana
Lot # 21 ,containing 6,371 SJ.:!:, in
Stonford Pork
Section' 1
INSlR. # 200500009385
P.C. , 3, Slide ~
CERlIACA 1E of ClI~
INSlR. , 200500044195
Oay Twp, Homlton County
Sec 29" T18N. RJE
3486 Windy Knoll Lane
Carmel. IN 46074
Prepared Date: 06/08/07: By. AMA
Proposed Buyer(8): INVENTORY
tho Sclma1der CorporaUoD
8901 OUI Annue
_rort_
II'dl.,,"pn~, Indlana 482l8-1031
S17-82Il-7100
S17-82Il-7200 rAX
~
Sun"""
J.andlcape Arclllteclure
GIS'US
Geoloc7
Note:
This drawing is based on construction plans or record
drawings, and is not based upon a field survey, The
Schneider Corporation does not warrant the accuracy or
sufficiency of this information, Contractors should verify
existing conditions prior to any construction. Any
discreponcy found on this drawing should be reported to
The Schneider Corporation immediately; fam~g to do so
results in the contractors assumption of all liability.
Note:
Per Connel zoning ordinance 26.1.1 :
The residential district limits height to twenty-five
feet (25'), however a dwelling may be increased in heiqt\t
to thirty-five feet (35') provided the side and rear yards
are increased an additiooal ooe foot (1') for each
one foot (1') the structure exceeds the fIrSt
twenty-five feet (25') In height.
(70'R/W)
Plot Pion legend
[jiQjj]] Proposed Grades
000.0 Existing Grodes
_000.0- Contour Grode
* Appro.. lot...ai location
- 8: - Sanitary Sewer Lines
-8T- Storm Sewer Lines
- lJ - Water Service Lines
- - - - - - - Sub-Surface Drain Lines
. ~onhole (Sanitary or Storm)
. Beehive Inlet (Storm)
II1II Curb Inlet (Storm)
D End Section (Storm)
.... fire Hydront
- .."" - ".." - Flow line of swale
Buiidlng Line (Bl / BSl)
- - - - - - - Easement line
Community Restrictions:
Side Yard =3' min.
Rear Yord = N/A
Aggregate = 6 (B.H.)
Note: Sanitary Sewer
Top of Costing Information
Upstreom ~onhole. TC= 916.52
Downstreom ~onhaie, TC=917.73
per record drawing
DetoM of Ground/ Storm
Water flow pottern to(
individual lots.
Lot # 21
Vb07.0075245
U
~
=~=
~
/fJ!
/ @
Sidewalk to be ploced
7' from property line,
5' from bock of curb,
per pion.
Ground Cover Calculations
Drive = 614 SrI
Public Walk = 219 SrI
Privote Wolk =91 SFt
Hydroseeding =n/o SFt
Sod = 478 SYt, from
entire yard
Assumed North
Scale: 1- = 30'
R.H. of Indiono
Finished Floor Elevation Information
Pod Grode = 917.7 per plan
Pod Grode + 0.7' = Gor0ge FFE (918.4 )
Goroge FFE + 1.5' = Residentiol FFE (919.9)
Residentiol FFE - 9.0' = Bosement FFE (910.9)
FLOOD HAZARO STATEMENT
CERnFiCA nON
,,\\\\\\\\111111111//1//11111
~~'\c: L /'ll'~
~ .~.'.'~ . ,,~bh ~
i'iii .~, ............. 'T(/~~~
ff~...~G\S Tc.lye......"".,o~
&<:::::)....~ No o....;<>~
f ( 50303 '") 1 Nol. ~
% \. STATE OF ..... iff The bosement e1evotloo, depicted hereon, ho!:! been determined aod bosed 00 the
~ r. .... .... <:'t ~ pad grode! ond/ot conlour1l token from the construction plans for this subdivision.
~ ~;-.!.IvDIA~!:'" ~~~ Unle$S stoled. no Informotlon oboot fluctuating walee tables, soil conditions. or sci
~ 'Yf) ...........~i (. 4\ ~ twas has been provided or slotoo on BOld plans. This lot Is located neat 0 body
~4/1. SUR, \.. ~~# of water. lot Of soli conditions may requ..e that the basement floor elevation be
1'11111111/11l111\\\\\\\\\\'I held 2 foot obow nonnal pool elevation. Site investigation may be needed if water
~ Is encountered during the 8lCcovotlon process or If other known watll( elevation Of
sons conditions ate present Investigation ond ooy remedial procedures Is at the
\ discretion of the bIllder to detel1n1ne end toke appropriote steps of adioo If ooy
~ '- . ground woter Is encountered durfng eXCQvatlon the buDder is encouroged to contact
The Sctlnelder Corporation to discuss possllle courses 01 octlon.
This drawing is not In ended to be represented as a retracement or
original boundary survey, a route survey, or a Surveyor Location Report.
Note: 8uildertOeflSUr~~
positive drainoge away ~
from structure(s). '1 .;.!. 4: \ 9",~E.
TYPICAL SWALE SECTlON
Note ; The garage finished floor elevotion
is 1.3' above the curb at the drive, per pion.
I
$Jg A3t5
58..18'
.27
Note:
The contractor is to maintain a minimum
distance of tell feet (10') between the
sanitry sewer ond water line loterals.
Flood Hazard Statement: The accuracy of any flood hazard data shown on this report is subject to map scale
uncertainty and to any other uncertainty in location or elevation on the referenced flood insurance rate map. ALL of
the within described land DOES NOT LIE within that special flood hazard zone A as said land plots by scale Of1
flood insurance rate map # 18057 0205F for City of Carmel, Indiana (maps dated February 19, 2003).
~GNA lURE :
DAlE: