Loading...
HomeMy WebLinkAbout07060133 Site Plan ;- ~~ Scmeider Tbe Schneider Corporation 8901 0UlI .benue IlIstcrlc Fort IImison "uli.I"Ip"ti~, Indiana i8216-1037 317-826-7100 317-1126-7200 FAX EngIneerIng 3umylIIi LondIcape _tecture GIll.1l3 GeoloiY This Plot Plan Prepared For: SDverthome Homes Lot # 34 . containing 19,528 S.F.:!:, in Aberdeen Bend SubdMslon Section' 1 INSTR. , 200500066134 Book , 3, Page , 739 HamDton County, Oay Township 12765 TRAM LANE (50' R/W) Cannel, IN 46032 Prepared Date: 06/07/07: By: KAG Community Restrictions: Side Yard = N/A Rear Yard = 25' Aggregate = 30' Zoning = SI Silverthorne Homes Pad Grade = 916.0 per plan Pad Grade + 1.0' = Garage m (917.0) Garage m + 0.5' = Residential m (917.5 ) Residential m - 10.0' = Basement m (907.5 ) Driveway Slape = 2. 7~ Note: The garage finished floor elevation is 2." above the curb at the drive, per plan. Ground Cover Calculations: Drive = 1 ,36DSH Public Walk = 752 SF f Private Walk = 207 SFf Seeding = 7,920 SH Sod = 8,182 SFf ,to the rear of home. , Plot Plan Legend Eli2Q]J Praposed Grades 000.0 Existin9 Grades _000,0- Contour Grade * Approx. LGteral Location - S - Sanitary Sewer Unes -8'1'- Storm Sewer Lines - IJ - Water Service Lines - - - - - - - Sub-Surface Drain Lines II Manhole (Sanitary or Storm) . Beehive inlet (Storm) IIIlI Curb Inlet (Storm) D End Section (Storm) ... Fire H)<irant - " " c - " " " - Flow Line of swote Note: Sanitary Sewer Top of Casting Information Upstream Manhole, TC= 915.60 Downstream Manhole, TC=913.80 per plan. P, z , , / , , , , , , , , , , , / , , , , /" I t;1:J ~II 167.03' "' 49.61 ~ ... ~. " "0 . I aeE NOTE: IN THE RESIDENTIAL DISTRICTS UMITING HEIGHT OP '- ., TO TWENTY-fiVE (25) FEET, A DWEWNG MAY BE TYPICAL SWALE SECTION INCREASED IN H8GHT TO THIRTY-fiVE (35) FEET PROVIDED THE SIDE AND REAR YARDS ARE INCREASED AN ADDITIONAL FOOT FOR EACH FOOT SUCH STRUCTURE EXCEEDS TWENTY-FlVE (25) FEET IN H8GHT. PER CARMEL ZONING ORDINANCE 26.1.1. Note: This drawing is bosed on construction plans or record drawings, and is not based upon a field survey. ]he Schneider Corporation does not warrant the accuracy or sufficiency of this Informotian. Contractors should verify existing conditions prior to any construction. Any; discrepancy found an this drawing should be reported to The Schneider Corporation immediately. failing to do sa results In the contractors assumption of ali liability. Note: . The bosement elevation. depicted hereon, has been determined and based on the pad grades and/O( contours taken from the; constructron plans for this 3Ubdlvlslon. Unless stated, no Informatron about fluctuating water tables. soD conditions, 0( son t)pes has been provided 0( stated on said pions. This lot Is located near Ii body of water. lot 0( soD conditions may require that the basement floor elevation be held 2 foot above nOm1aJ pool elevation. SIte I Investrgation may be needed If water Is encountered during the excavation process 0( If other known water elevatIon 0( soDs condltrons are present. Investigation and any remedial procedures Is at the discretion of the buDder to detormlne and take appropriate steps of octlon. If any ground water Is encountered during 'excavation the buDder Is encouraged to contact The Schneider Corporatlon to discuss possible courses of action. NOTIE: SUMP PUMP(S) TO BE PLACED BY BUILDER AS NEEDED. DetaD of t)plcal Ground Water flow pattern for Individual lots. LOT# 34 VB07.0075230 o ~ =~= "'- :--. "" Nate: Builder to ensure positlve drainage away from structure(s): o . Assumed North Scale: 1. = 30' , I 1 I I 1 1 59.5' I .................................... , I I ,OJ c; I~ I::; '!2 I 1 I I , I I I a ~ a - OJ ci ~ - :, or. 1 I 912.60 I FLOOO HAZARD STATIEMENT CERTlFICA TlON ,\\\\\\\\lIIIIIII/III/III//, ;#\\ L c,"'~ ~:..~ .......~."".:,ph~ ~~...~G\SN E:IT~"".~A~ ~~ .'q.. 0 ()'. A~ :s.: I ". I ~ ~ : ~ I:=' ~ ( S0303 ) i ~ % ..... STATE OF ./ I~ ~ /". .",~ ~~~>:,Iy01A~~""'~~ ~'11) "S""U"R''';i (~ # ~4'/, 'i \. ~~\~ ~/llll/l/l/l/illI\\\\I\\\\~ ~l.P-r1 Note: The contractor is to maintain a minimum distance of ten feet (10') between the sanitary sewer and water ilne laterals. NOTE: CONTRACTOR SHALL CUT l' OFF OF SANITARY LATERAL AND BEGIN FROM THAT POINT AND CONNECT TO HOUSE FOLLO\\1NG PLOT PLAN. This drawing is not intended to be represented os 0 retrocement or original boundary survey, a route survey, or a Surveyor Location Report. flOOD HAZARD STATEMENT The accuracy of any flood hazard data shawn an this piat plan is subject to map scale uncertainty and to any ather uncertainty in location or elevation on the referenced flood Insurance rate map. ALL of the within described iand DOES NOT UE within that special flood hazard zone A as sold land plots by scale an community-panel , 180080 0205F of the flaad insurance rate maps far Carmel, IN (maps dated Feb. 19, 20D3).