Loading...
HomeMy WebLinkAbout07060193 Receipts/Permits tern 7 of 15 CITY OF CARMEL PERMIT RECEIPT See: Twp: Rng: Sub:B62 Blk: Lot:1065 PARCEL ID ........: ZB621065 DATE ISSUED.......: 06/21/2007 RECEIPT #...... ...: 25498 REFERENCE ID # .... 07060178 SITE ADDRESS ...... 2469 GLEBE ST SUBDIVISION ......: VILLAGE OF WESTCLAY CITY .............: CARMEL IMPACT AREA. .....: OWNER ............: ADDRESS ..........: CITY/STATE/ZIP ...: RECEIVED FROM ....: CONTRACTOR .......: COMPANY. ..... ....: ADDRESS. .... .....: CITY/STATE/ZIP... : TELEPHONE .... ..... JUSTUS AT WESTFIELD, LLC 1398 N. SHADELAND AVENUE INDIANAPOLIS, IN 46219 JUSTUS AT WESTFIELD LIC # XALLSTAR ALL STAR EXCAVATING CICERO, IN (317) 223-4818 OPERATOR: COPY # FEE ID UNIT QUANTITY AMOUNT PD-TO-DT THIS REC NEW BAL --------- ------------- ---------- ---------- ---------- ---------- ---------- SFWATCONN FLAT RATE OTAL PERMIT : 1. 00 1310.00 0.00 1310.00 0.00 1310.00 1310.00 0.00 0.00 , CITY OF CARMEL / CLAY TOWNSHIP WATER / SEWER PERMIT / RECEIPT Permit #: 07060178 Date: 06/21/2007 PARCEL 10 #: ZB621065 LOT & SUBDIVISION: 1065 VILLAGE OF WESTCLAY ADDRESS OF CONSTRUCTION: 2469 GLEBE ST CARMEL, IN 46032 PAYMENT RECEIVED FROM: Name: JUSTUS AT WESTFIELD CHECK #: 0001049 EXCAVATOR INFORMATION: Name: ALL STAR EXCAVATING Ph. #: (317) 223-4818 Fax #: Street Address: CICERO, IN Bond Expiration: Email: PERMIT TYPE: USEWRWATR SEWERlWATER PERMIT Special Notes/Conditions: LOT 1065 VILLAGE OF WEST CLAY. WATER CONNECTION PERMIT. . NO NOTES' The building & Sewer Shall be pve sewer pipe meeting ASTM specifications 3034 SDR 35 of latest revision; or vitrified clay pipe, meeting, ASTM specifications C-700 for extra strength clay pipe of latest revision unless other materials are hereby permitted in writing. The scwe~ shall be installed in accordance with ASTM 2321 for pve pipe and the Unifonn Plumbing Code for the State of Indiana. All installations shall be in strict compliance with pertinent City ofCarrnel ordinances. Back Water check valves shall be installed in accordance with City Code Section 9-122(a), and sections P3008.1 and .2 of the International Residential Code. All building sewers shall be 6" diameter. All installations shall be "ooen trench" insoected and aooroved bv the Carmel Sewer Deoartment before anv backfillimr is done. Non- compliancc may rcsult in digging up the sewer installation and/or denial of future sewer permits and/or denial of water connections. No footing or foundation drains or other sources of ground water or stoml watcr shall bc permitted to enter the public sewer. Sewer insDcctions should be reauested at (J 17) 571-2648 one to four hours in advance. No inspections or installations will be made on Saturday or Sunday or holidays unless arrangements are made at least 24 hours in advance. All plumbers or contractors installing sewer (or water) lines shall have a plumbers bond posted with the CITY ENGINEER'S OFFICE. Ifany st~ect m1Jst he ClIt. a sen::lnlte street ellt nermit shall he ohtaincci. PAYMENT RECEIVED BY: FEES: $1,310.00 RA1[D ~ -- c. APPLICANT NAME: THOMAS L. Item 1 of CITY OF CARMEL 1 PERMIT RECEIPT Sec: Twp: Rng: Sub:B62 B1k: Lot:1065 PARCEL ID ........: ZB621065 DATE ISSUED.......: 07/05/2007 RECEIPT #.........: 25639 REFERENCE ID # ...: 07060193 SITE ADDRESS ...... 2469 GLEBE ST SUBDIVISION ......: VILLAGE OF WESTCLAY CITy.......... ...: CARMEL IMPACT AREA ......: OWNER ............: JUSTUS AT WESTFIELD, LLC ADDRESS ..........: 1398 N. SHADELAND AVENUE CITY/STATE/ZIP ...: INDIANAPOLIS, IN 46219 RECEIVED FROM....: CONTRACTOR .......: COMPANy....... ...: ADDRESS..... .....: CITY/STATE/ZIP ...: TELEPHONE ......... JUSTUS HOME BUILDERS LIC # JUSTHOM JUSTUS HOME BUILDERS 1398 N SHADELAND AVE INDIANAPOLIS, IN 46219 (317) 353-8311 FEE ID UNIT QUANTITY AMOUNT PD-TO-DT ---------- ------------- ---------- ---------- ---------- IRESELEMTR FLAT RATE 1. 00 57.50 0.00 IRESFINAL FLAT RATE 1. 00 57.50 0.00 IRESFTSLB FLAT RATE 1. 00 57.50 0.00 IRESFTSLB+ FLAT RATE 1. 00 57.50 0.00 IRESROUGH FLAT RATE 1. 00 57.50 0.00 PRIF FLAT RATE 1. 00 1261.00 0.00 RESC/O FLAT RATE 1. 00 55.50 0.00 RESSINGLE SQUARE FEET 3,849.00 788.90 0.00 ---------- ---------- TOTAL PERMIT : 2392.90 0.00 METHOD OF PAYMENT AMOUNT NUMBER CHECK TOTAL RECEIPT : 2392.90 12185 ------------ ------------ 2392.90 OPERATOR: COPY # THIS REC 57.50 57.50 57.50 57.50 57.50 1261.00 55.50 788.90 2392.90 I elacey / 1 I {1V I I ! j NEWj BAL -----i----- I 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 - - - - _1- _ _ __ 0.00 CITY OF CARMEL / CLAY TOWNSHIP IMPROVEMENT LOCATION PERMIT APPLICATION For: Residential Nev.' Structures, Additions, Rcmodcl5, & Accessor)' Buildings Permit #: 07060193 Date: 07/05/2007 PARCEL 10 #: ZB621065 LOT & SUBDIVISION: 1065 VILLAGE OF WESTCLAY ADDRESS OF CONSTRUCTION: 2469 GLEBE ST CARMEL, IN 46032 Township?: Zoning: PUD Flood Zone: N PROPERTY OWNER INFORMATION: Name: JUSTUS AT WESTFIELD, LLC Ph. #: 3175752350 Fax #: 3175758950 Street Address: 1398 N. SHADELAND AVENUE INDIANAPOLIS, IN 46219 CONTRACTOR INFORMATION: Name: JUSTUS HOME BUiLDERS Ph, #: (317) 353-8311 . Fax #: 3173521570 Email: Street Address: 1398 N SHADELAND AVE INDIANAPOLIS, IN 46219 Plumber's Name: ACORN PLUMBING Codes for Project: IPC Lot Split: N PERMIT TYPE: RESTOWN RESIDENTiAL TOWNHOME Water Service by: CARMEL Sewer Service by: CTRWD Foundation Type: SLAB Manufactured Trusses: Y County Well Permit #: County Septic Permit #: Estimated Cost of Construction: $365000 Sump Pump: Y Deck: Porch: Y Square Footage: 3849 Model Home: Early Release ILP: N Special Notes/Conditions: LOT 1065 THE VILLAGE OF WEST CLAY. LIBERTY ROW TOWN HOMES. STATE #: 325752. CONST.TYPE: NONE. OCCUP.CLASS: TOWNHOUSE. "SEE MASTER FILE 07060187 FOR PLANS & STATE REL. INFO. SEE NOTEPAD. MASTER PERMIT FILE FOR THIS BUILDING is # 07060187, which holds the master plans for the building and the State release for this building. State release # 325752 INFO NOTES: Dated 6104/07. Standard release for ARCH, ELEC, FDN, MECH, PLUM, & STR. Ten (10) conditions re: 1. Project has been reviewed under the 2005 Indiana Residential Code. 2. Design of townhouses shall be in accordance with seismic provisions. 3. Exterior walls with a fire separation distance less than 3 feet shall have not less than a one-hour fire-resistive rating with exposure from both sides. 4. Garages shall be separated from the residence and its attic areas by a smoke separation of not less than 1/2-inch gypsum board applied to garage side. Garages beneath habitable rooms shall be separated from all habitable rooms above by not less than SIB-inch Type X gypsum board or equivalent. The structure supporting the separation shall also be protected by not less than 1/2-inch gypsum board or equivalent. 5. Area of garage floors used for parking of automobiles or other vehicles shall be sloped to facilitate the movement of liquids to an approved drain or toward the main vehicle entry doorway 6. Every sleeping room shall have at least one open able window or exterior door that meets the minimum area and dimension requirements per code. 7. Townhouses shall be separated by fire-resistance rated wall assembly. 8. Each individual townhouses shall be structurally independent. 9. Townhouse common walls shall be continuous from the foundation to the underside of the roof sheathing, deck, or slab, and shall extend the full length of the common wall. 10. Buildings that are heated or mechanically cooled shall be constructed so as to provide the required thermal pe pertormance of the various components. This permit is valid only if construction commences within one (I) year of the date of issuance of the State Commercial Design Release. All construcition must be completed (Cia issued) within two (2) years of the issuance date. I, the undersigned, agree that any construction. reconstruction, enlargement, relocation, or alteration of a structure, or any change in the use of lanu or structures requested by this application will comply with, and confonn to, all applicable laws of the State of Indiana, and the UZoning Ordinance of Carmel Indiana - 1993~ (Z- 289) and amendments, adopted under authority of J.e. 36-7 et seq, General Assembly of the State of Indiana, and all Acts amendatory thereto. J further ce~tify that only kitchen, bath, and floor drains are connected to the sanital)' sewer. I further certify that the construction will not be used or occupied until a I Certificate of Occupancy has been issued by the Department of Community Services, Cannel, Indiana. : I APPLICANT NAME: THOMAS L. FEES: RES ELECTRICAL/METERB. RES FINAL 57.50 RES FOOTING & UNDRSLB 2ND REQ'D FOOT/UNDSLAB RES ROUGH-IN PARK & REC. IMPACT FEE RESIDENTIAL CIO SINGLE FAMILY DWELLING RAYMOND 57.50 57.50 57.50 57.50 1261.00 55.50 788.90 SF Residential '175732007 Regional Waste District SANITARY SEWER PERMIT INDIVIDUAL,LOT 1 EXISl'lNG BUILDINGS Permit Type Final Lift Station 23 126th Street Station Treatment Plant MIX Subdivision Village of WestClay Section' Number 600,1' Blk Q Builder Justus Homes Parcel Acreage Empl<;>yees Square Footage Invoice Number Lot Number 1065 Address Number 2469 Street Glebe St City Carmel Zip Code 46032 County Hamilton Plan Review and Inspection Application Fee EDU Fee Interceptor Fee Fees Due $100,00 $1,650,00 $1,750.00 PLEASE NOTE: Installation of building sewer shall be per the specifications of the Clay Township Regional Waste District (see reverse) and any conditions noted below, All installations shall be inspecteq by District personn,elduring "open trench" phase and before backfilling with stone to twelve inches above the pipe, NO footing or foundation drains, , or other sources of ground or stormwater, shall be permitted 'to enter the District's,sanitary sewer system, The District will assume no liability for drains which are below'the grade level of the nearest downstream manhole nor for laterals which are extend,ed beneath driveways or sidewalks, The permit holder(property owner, developer or builder) will be responsible.for damages to the District's sewer system, This includes damages to manholes, castings, manhole lids and the like; c~used by construction activity on the building site which is,the subject of this permit.. Inspections by the District are,MANDATORY and shall be'arranged by contacting the District's office at844-9200 24 hours in advance, All new construction will be placed on billing six months.after connection has been made or when water is, connected, whichever comes first. Up VWC.147W VWG.146W Down The,building has a: Grease Trap No Slab Foundation Yes Lid Elevation 903,52 It 906.41 It Grit Interceptor No Crawl Space No First Floor Elevation 907.58 It Grinder Station ,No ,Basement No Basement Elevation Calculation is based on both Manhole Lid Elevations-andtl1e elevation of iheFirs{Floor I~06]--~---1~.1'"C'ZJ 907.58 It I I Per Ordinance 9-13-99'and the elevations provided, the substructure shall beplumbedby: Not Applicable Cj~ O,J? The District reserves the right'to inspect all sump pump connections to ensure no illegal conneCtion,s haye beerl made. Manhoies shall remain accessible at all times, Buried manQoles will be corrected'byth" DeveloperlOwner. Conditional'Permit Terms: Plans Submitted No No Connection No Certificate of Insurance No Inspection Notice No Fees Paid No Plan Review No Other Permits No No Occupancy No Fats~.?i1s, & Grea~e, No Manhole, Core Two sets of plans showing at least one sanitary,manhole and top of casting elevation NO CONNECTiON to the sewer until further notification, I Certificate of Insurance must be on file with CTRWD listed as certificate holder. 48 hours notite before work starts on manhole core drilling or cuts aGliv,e lines , " ' . .W,l/iI,Wllf.' AU District feeswill be paid in fuli. ;;''<-'1> -00." ;;Si '.L Approval pending Districts review of plans, i: rD Copies of approved permits from appropriate county orcit~age\f"V~t\\ N~' occupancy until further notlficallon \:} '\ ~ f~t~,.Oils,an_C!.QLe_?~e Faciliti~s.willabide;by District standa~~>oh...." -- -'~"r\"'~{? - _}-,...e.-_ '-"SHIP REIlI\)' The closest mailhole withouVa bolt down lid is VWC"11 0 with a top' of casting elvation'of 906,30 By sign,iri9_below, ,I a,ttest thaU am familiar ittl1fi"e'Dlstrie' specificatiops and agreeHo ac(::ept'responsibilityfor all wor~ done',Linder this permit. Builder I Owner Signature ~~~~ ~ Printed Name . 1J4.rl1 Ie A d'.~ ~ pprove, , ____ . eitner, Director of Adminisfration& Customer Service Pho~e Number 2/JI-tcSco'7 Permit Date 512912007 Revised 4/26/07 Permit is valid, for ONE:YEARfrom the date'issued, Permihalid only with CTRWD seal in red ink, ~~ Scmeider !he SehIUll.der CorporaUOD 8901 QUa Avenue HlItDri.e Port Harriacm to,ti"'''';''p'''HtI, Indiana 48218-10S'7 317-826-7100 317-82<1-7200 fa This Plot Plan Prepared For: Justus Homes Lot # 1065 Block "Q" (33,167 sF) The Village of Westelay Section # 6001 INS1R # 200500080672 Certificate of Correction INS1R # 200600061729 PC 3, SUOE 790 Hamilton County, Cloy Township Sec 29, 118N, R03E 2469 Glebe Street ( 90' R/W) Carmel, IN 46032 Prepared Oate: 12/04/06: By. AMA Community Restrictions: Side Yard = 5' Minimum on one side Rear Yard = None Aggregate = 20% of lot width at building line. Zoning = PUO Note: BuUder to ensure positive drainage away from structure{s). )5.73 ~ ~ ~ :l: .... f:\ ~ z 0. 15 ~ '" i ~ 12' ALLEY EASEMENT ---- TC=906.41 PER RECORD ORA\\ING -- Sumy\D& ~ ArcbIloclun GIll'US GooI'IJ , Note: I This drawing is based on construction plans or record drawings, and spot elevations obtained in 0 field survey doted November 30, 2006. The Schneider Corporation ' does not warrant the accuracy or sufficiency of this information. Contractors should ver'lfy existing conditions prior to any construction. Any discrepancy found on this drawing should be reported to The Schneider I Corporation immediately, faDing to do so results in th~ contractors assumption of all liability. Note: Per Cormellooing ordintmte 26.\.1 : The I residential district limits height to twenty-five feet (25'), however 0 dwelling may be increased in height to I thirty-five feet (35') pro~ded the side and rear )O'ds ore increased on odditional one foot (1') for each one foot (1') the structure exceeds the first twenty-five feet (25') in height ' Plot Plan Legend []QQ]] Proposed Grades 000.0 ExIsting Grades __ 000.0-- Contour Grade * Approl<. Lateral Location _ . _ Sanitary Sewer Unes _ ar- Storm Sewer Lines _ IJ - Water Service Lines _ _ _ _ _ _ _ Sub-Surface Drain lines . Manhole (Sannory or Storm) . Beehive Inlet (Storm) IlIII Curb Inlet (storm) D End Section (Storm) ... Fire Hydrant _ 000 _ 000 -Flow Line of swole _ Bundlng line (BL / BSL) _ _ _ _ _ - - Easement Line GLEBE STREET 22' B-B BLOCK 0 LOT 1065 U ~ =~= ~ Assumed North Scole I" = 20' ~. . ~ ..\ 0\" I TYPICAL- $WALE SECTION r CHAIRBACK CURB RE'i1~ON 11 MOl{!) BUiLDINGS & ADDED C.O.C. 12-05-06 AMA 8.5' PER PLAN RE,^SION #2 RE'i1SED FIT ,\NO DRIVE SlOPE 12-12-06 AMAjsI<N RE,^~ON fJ RE,^SED S,\N. LAT, FIT/SlOPE ON 1059-1063 ARO CUENT 05-18-07 Sl<N ..L 5' WALK ..L s' DU&SE 12' BTL 30.33' LOTS 1064--1073 Note: Sanitary Sewer Top of Casting Information Upstream Manhole, TC= 903.52 Downstream Manhole, TC= 906.41 Non-Bolted Manhole IllO,Existing TC lor=906.30 per record drawing ,.., ,.., r...: o <7> SLAB ~ ~ FFE=9D7.58~ ~ PROPOSED :l: .... FRM&MSY f:\ ~ RESIOENCE ~ o. ~ '" \:j ~ 'The driveway slope is 4.1% measured at the centerline of the driveway pavement from the edge of teh olley pavement to the 9arage floor lip at the building face. GAR=907.25 THREE CAR GARAGE 30.33' CONC. .... DRIVE l=-=-~ .. ,.., .n 12' ALLEY EASEMENT Note: The cOJ'Itroetor is to mointair. <1 mil'oimum dlst<1nce of ten feet (10') between the sanitary sewer and water Hne loterals. ---- FLOOD HAZARD STATEMENT CERTIFICATION - ' ,\I\lIIIIIIIIIIIII/lJIIIII/' #""c L ~:/% #' ~'?,,,"":"...~/(h~ ~t...~...;:o\S TEF?i:...... A~ ",~.,,~v No 0"'''';0''' i ( 50303 \) 1 % .... STATE OF ,.: ff \ ~......livDI A~ t>-.....~ ff ~ '41J....S....U..ii~i\ ~ # ~1Oj, l\' '1..-# ~///IIII/1I1IIIi1i1IIIII\" "-'-'- l . r-v ColI BLOCK ''U'' COMMONS ColI ---- This drawing is not intended to be represented (lS 0 retrocemen\ or original boundary survey, a route survey, or a Surveyor Location Report. Flood Hazard Statement: The accuracy of any flood hazard data shown on this report is subject to map scale uncertainty and to any other uncertainty in location or elevation on the referenced flood insurance rate map. ALL of the within described land DOES NOT lie within that special flood hazard zone AE as said land plots by scale on flood insurance rate map #18057C 0205 F for the City of Carmel, Indiana dated February 19, 2003.