HomeMy WebLinkAbout07060193 Receipts/Permits
tern
7 of 15
CITY OF CARMEL
PERMIT RECEIPT
See: Twp: Rng: Sub:B62 Blk: Lot:1065
PARCEL ID ........: ZB621065
DATE ISSUED.......: 06/21/2007
RECEIPT #...... ...: 25498
REFERENCE ID # .... 07060178
SITE ADDRESS ...... 2469 GLEBE ST
SUBDIVISION ......: VILLAGE OF WESTCLAY
CITY .............: CARMEL
IMPACT AREA. .....:
OWNER ............:
ADDRESS ..........:
CITY/STATE/ZIP ...:
RECEIVED FROM ....:
CONTRACTOR .......:
COMPANY. ..... ....:
ADDRESS. .... .....:
CITY/STATE/ZIP... :
TELEPHONE .... .....
JUSTUS AT WESTFIELD, LLC
1398 N. SHADELAND AVENUE
INDIANAPOLIS, IN 46219
JUSTUS AT WESTFIELD
LIC # XALLSTAR
ALL STAR EXCAVATING
CICERO, IN
(317) 223-4818
OPERATOR:
COPY #
FEE ID UNIT QUANTITY AMOUNT PD-TO-DT THIS REC NEW BAL
--------- ------------- ---------- ---------- ---------- ---------- ----------
SFWATCONN FLAT RATE
OTAL PERMIT :
1. 00
1310.00
0.00
1310.00
0.00
1310.00
1310.00
0.00
0.00
,
CITY OF CARMEL / CLAY TOWNSHIP
WATER / SEWER PERMIT / RECEIPT
Permit #: 07060178
Date: 06/21/2007
PARCEL 10 #: ZB621065
LOT & SUBDIVISION: 1065 VILLAGE OF WESTCLAY
ADDRESS OF CONSTRUCTION: 2469 GLEBE ST CARMEL, IN 46032
PAYMENT RECEIVED FROM:
Name: JUSTUS AT WESTFIELD
CHECK #: 0001049
EXCAVATOR INFORMATION:
Name: ALL STAR EXCAVATING
Ph. #: (317) 223-4818 Fax #:
Street Address: CICERO, IN
Bond Expiration:
Email:
PERMIT TYPE: USEWRWATR
SEWERlWATER PERMIT
Special Notes/Conditions:
LOT 1065 VILLAGE OF WEST CLAY. WATER CONNECTION
PERMIT.
. NO NOTES'
The building & Sewer Shall be pve sewer pipe meeting ASTM specifications 3034 SDR 35 of latest revision; or vitrified clay pipe, meeting,
ASTM specifications C-700 for extra strength clay pipe of latest revision unless other materials are hereby permitted in writing. The scwe~
shall be installed in accordance with ASTM 2321 for pve pipe and the Unifonn Plumbing Code for the State of Indiana. All installations shall be
in strict compliance with pertinent City ofCarrnel ordinances. Back Water check valves shall be installed in accordance with City Code Section
9-122(a), and sections P3008.1 and .2 of the International Residential Code. All building sewers shall be 6" diameter.
All installations shall be "ooen trench" insoected and aooroved bv the Carmel Sewer Deoartment before anv backfillimr is done. Non-
compliancc may rcsult in digging up the sewer installation and/or denial of future sewer permits and/or denial of water connections.
No footing or foundation drains or other sources of ground water or stoml watcr shall bc permitted to enter the public sewer.
Sewer insDcctions should be reauested at (J 17) 571-2648 one to four hours in advance.
No inspections or installations will be made on Saturday or Sunday or holidays unless arrangements are made at least 24 hours in advance. All
plumbers or contractors installing sewer (or water) lines shall have a plumbers bond posted with the CITY ENGINEER'S OFFICE. Ifany st~ect
m1Jst he ClIt. a sen::lnlte street ellt nermit shall he ohtaincci.
PAYMENT RECEIVED BY:
FEES:
$1,310.00
RA1[D
~ --
c.
APPLICANT NAME: THOMAS L.
Item
1 of
CITY OF CARMEL
1 PERMIT RECEIPT
Sec: Twp: Rng: Sub:B62 B1k: Lot:1065
PARCEL ID ........: ZB621065
DATE ISSUED.......: 07/05/2007
RECEIPT #.........: 25639
REFERENCE ID # ...: 07060193
SITE ADDRESS ...... 2469 GLEBE ST
SUBDIVISION ......: VILLAGE OF WESTCLAY
CITy.......... ...: CARMEL
IMPACT AREA ......:
OWNER ............: JUSTUS AT WESTFIELD, LLC
ADDRESS ..........: 1398 N. SHADELAND AVENUE
CITY/STATE/ZIP ...: INDIANAPOLIS, IN 46219
RECEIVED FROM....:
CONTRACTOR .......:
COMPANy....... ...:
ADDRESS..... .....:
CITY/STATE/ZIP ...:
TELEPHONE .........
JUSTUS HOME BUILDERS
LIC # JUSTHOM
JUSTUS HOME BUILDERS
1398 N SHADELAND AVE
INDIANAPOLIS, IN 46219
(317) 353-8311
FEE ID UNIT QUANTITY AMOUNT PD-TO-DT
---------- ------------- ---------- ---------- ----------
IRESELEMTR FLAT RATE 1. 00 57.50 0.00
IRESFINAL FLAT RATE 1. 00 57.50 0.00
IRESFTSLB FLAT RATE 1. 00 57.50 0.00
IRESFTSLB+ FLAT RATE 1. 00 57.50 0.00
IRESROUGH FLAT RATE 1. 00 57.50 0.00
PRIF FLAT RATE 1. 00 1261.00 0.00
RESC/O FLAT RATE 1. 00 55.50 0.00
RESSINGLE SQUARE FEET 3,849.00 788.90 0.00
---------- ----------
TOTAL PERMIT : 2392.90 0.00
METHOD OF PAYMENT
AMOUNT
NUMBER
CHECK
TOTAL RECEIPT :
2392.90
12185
------------
------------
2392.90
OPERATOR:
COPY #
THIS REC
57.50
57.50
57.50
57.50
57.50
1261.00
55.50
788.90
2392.90
I
elacey /
1 I {1V
I
I
!
j
NEWj BAL
-----i-----
I 0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
- - - - _1- _ _ __
0.00
CITY OF CARMEL / CLAY TOWNSHIP
IMPROVEMENT LOCATION PERMIT APPLICATION
For: Residential Nev.' Structures, Additions, Rcmodcl5, & Accessor)' Buildings
Permit #: 07060193
Date: 07/05/2007
PARCEL 10 #: ZB621065
LOT & SUBDIVISION: 1065 VILLAGE OF WESTCLAY
ADDRESS OF CONSTRUCTION: 2469 GLEBE ST CARMEL, IN 46032
Township?: Zoning: PUD Flood Zone: N
PROPERTY OWNER INFORMATION:
Name: JUSTUS AT WESTFIELD, LLC
Ph. #: 3175752350 Fax #: 3175758950
Street Address: 1398 N. SHADELAND AVENUE INDIANAPOLIS, IN 46219
CONTRACTOR INFORMATION:
Name: JUSTUS HOME BUiLDERS
Ph, #: (317) 353-8311 . Fax #: 3173521570 Email:
Street Address: 1398 N SHADELAND AVE INDIANAPOLIS, IN 46219
Plumber's Name: ACORN PLUMBING
Codes for Project: IPC
Lot Split: N
PERMIT TYPE: RESTOWN
RESIDENTiAL TOWNHOME
Water Service by: CARMEL
Sewer Service by: CTRWD
Foundation Type: SLAB
Manufactured Trusses: Y
County Well Permit #:
County Septic Permit #:
Estimated Cost of Construction: $365000
Sump Pump: Y
Deck:
Porch: Y
Square Footage: 3849
Model Home:
Early Release ILP: N
Special Notes/Conditions:
LOT 1065 THE VILLAGE OF WEST CLAY. LIBERTY ROW
TOWN HOMES. STATE #: 325752. CONST.TYPE: NONE.
OCCUP.CLASS: TOWNHOUSE. "SEE MASTER FILE 07060187
FOR PLANS & STATE REL. INFO. SEE NOTEPAD.
MASTER PERMIT FILE FOR THIS BUILDING
is # 07060187, which holds the
master plans for the building and the
State release for this building.
State release # 325752 INFO NOTES:
Dated 6104/07. Standard release for
ARCH, ELEC, FDN, MECH, PLUM, & STR.
Ten (10) conditions re:
1. Project has been reviewed under the
2005 Indiana Residential Code.
2. Design of townhouses shall be in
accordance with seismic provisions.
3. Exterior walls with a fire separation
distance less than 3 feet shall have not
less than a one-hour fire-resistive
rating with exposure from both sides.
4. Garages shall be separated from the
residence and its attic areas by a smoke
separation of not less than 1/2-inch
gypsum board applied to garage side.
Garages beneath habitable rooms shall be
separated from all habitable rooms above
by not less than SIB-inch Type X gypsum
board or equivalent. The structure
supporting the separation shall also be
protected by not less than 1/2-inch
gypsum board or equivalent.
5. Area of garage floors used for
parking of automobiles or other vehicles
shall be sloped to facilitate the
movement of liquids to an approved drain
or toward the main vehicle entry doorway
6. Every sleeping room shall have at
least one open able window or exterior
door that meets the minimum area and
dimension requirements per code.
7. Townhouses shall be separated by
fire-resistance rated wall assembly.
8. Each individual townhouses shall be
structurally independent.
9. Townhouse common walls shall be
continuous from the foundation to the
underside of the roof sheathing, deck,
or slab, and shall extend the full
length of the common wall.
10. Buildings that are heated or
mechanically cooled shall be constructed
so as to provide the required thermal pe
pertormance of the various components.
This permit is valid only if construction commences within one (I) year of the date of issuance of the State Commercial Design Release. All construcition
must be completed (Cia issued) within two (2) years of the issuance date.
I, the undersigned, agree that any construction. reconstruction, enlargement, relocation, or alteration of a structure, or any change in the use of lanu or structures
requested by this application will comply with, and confonn to, all applicable laws of the State of Indiana, and the UZoning Ordinance of Carmel Indiana - 1993~
(Z- 289) and amendments, adopted under authority of J.e. 36-7 et seq, General Assembly of the State of Indiana, and all Acts amendatory thereto. J further ce~tify
that only kitchen, bath, and floor drains are connected to the sanital)' sewer. I further certify that the construction will not be used or occupied until a I
Certificate of Occupancy has been issued by the Department of Community Services, Cannel, Indiana. :
I
APPLICANT NAME: THOMAS L.
FEES:
RES ELECTRICAL/METERB.
RES FINAL 57.50
RES FOOTING & UNDRSLB
2ND REQ'D FOOT/UNDSLAB
RES ROUGH-IN
PARK & REC. IMPACT FEE
RESIDENTIAL CIO
SINGLE FAMILY DWELLING
RAYMOND
57.50
57.50
57.50
57.50
1261.00
55.50
788.90
SF Residential
'175732007
Regional Waste District
SANITARY SEWER PERMIT
INDIVIDUAL,LOT 1 EXISl'lNG BUILDINGS
Permit Type Final
Lift Station 23 126th Street Station
Treatment Plant MIX
Subdivision Village of WestClay
Section' Number 600,1' Blk Q
Builder Justus Homes
Parcel Acreage
Empl<;>yees
Square Footage
Invoice Number
Lot Number 1065
Address Number 2469
Street Glebe St
City Carmel
Zip Code 46032
County Hamilton
Plan Review and Inspection
Application Fee
EDU Fee
Interceptor Fee
Fees Due
$100,00
$1,650,00
$1,750.00
PLEASE NOTE: Installation of building sewer shall be per the specifications of the Clay Township Regional Waste
District (see reverse) and any conditions noted below, All installations shall be inspecteq by District personn,elduring
"open trench" phase and before backfilling with stone to twelve inches above the pipe, NO footing or foundation drains,
, or other sources of ground or stormwater, shall be permitted 'to enter the District's,sanitary sewer system, The District
will assume no liability for drains which are below'the grade level of the nearest downstream manhole nor for laterals
which are extend,ed beneath driveways or sidewalks, The permit holder(property owner, developer or builder) will be
responsible.for damages to the District's sewer system, This includes damages to manholes, castings, manhole lids
and the like; c~used by construction activity on the building site which is,the subject of this permit..
Inspections by the District are,MANDATORY and shall be'arranged by contacting the District's office at844-9200
24 hours in advance, All new construction will be placed on billing six months.after connection has been made or when
water is, connected, whichever comes first.
Up VWC.147W VWG.146W Down
The,building has a: Grease Trap No Slab Foundation Yes Lid Elevation 903,52 It 906.41 It
Grit Interceptor No Crawl Space No First Floor Elevation 907.58 It
Grinder Station ,No ,Basement No Basement Elevation
Calculation is based on both Manhole Lid Elevations-andtl1e elevation of iheFirs{Floor I~06]--~---1~.1'"C'ZJ
907.58 It I
I
Per Ordinance 9-13-99'and the elevations provided, the substructure shall beplumbedby: Not Applicable
Cj~
O,J?
The District reserves the right'to inspect all sump pump connections to ensure no illegal conneCtion,s haye beerl made.
Manhoies shall remain accessible at all times, Buried manQoles will be corrected'byth" DeveloperlOwner.
Conditional'Permit Terms:
Plans Submitted No
No Connection No
Certificate of Insurance No
Inspection Notice No
Fees Paid No
Plan Review No
Other Permits No
No Occupancy No
Fats~.?i1s, & Grea~e, No
Manhole, Core
Two sets of plans showing at least one sanitary,manhole and top of casting elevation
NO CONNECTiON to the sewer until further notification, I
Certificate of Insurance must be on file with CTRWD listed as certificate holder.
48 hours notite before work starts on manhole core drilling or cuts aGliv,e lines
, " ' . .W,l/iI,Wllf.'
AU District feeswill be paid in fuli. ;;''<-'1> -00."
;;Si '.L
Approval pending Districts review of plans, i: rD
Copies of approved permits from appropriate county orcit~age\f"V~t\\
N~' occupancy until further notlficallon \:} '\ ~
f~t~,.Oils,an_C!.QLe_?~e Faciliti~s.willabide;by District standa~~>oh...." -- -'~"r\"'~{? - _}-,...e.-_
'-"SHIP REIlI\)'
The closest mailhole withouVa bolt down lid is VWC"11 0 with a top' of casting elvation'of 906,30
By sign,iri9_below, ,I a,ttest thaU am familiar ittl1fi"e'Dlstrie' specificatiops and agreeHo ac(::ept'responsibilityfor all wor~ done',Linder this permit.
Builder I Owner Signature ~~~~ ~
Printed Name . 1J4.rl1 Ie
A d'.~ ~
pprove, , ____
. eitner, Director of Adminisfration& Customer Service
Pho~e Number
2/JI-tcSco'7
Permit Date 512912007
Revised 4/26/07 Permit is valid, for ONE:YEARfrom the date'issued, Permihalid only with CTRWD seal in red ink,
~~
Scmeider
!he SehIUll.der CorporaUOD
8901 QUa Avenue
HlItDri.e Port Harriacm
to,ti"'''';''p'''HtI, Indiana 48218-10S'7
317-826-7100
317-82<1-7200 fa
This Plot Plan Prepared For: Justus Homes
Lot # 1065 Block "Q" (33,167 sF)
The Village of Westelay
Section # 6001
INS1R # 200500080672
Certificate of Correction
INS1R # 200600061729
PC 3, SUOE 790
Hamilton County, Cloy Township
Sec 29, 118N, R03E
2469 Glebe Street ( 90' R/W)
Carmel, IN 46032
Prepared Oate: 12/04/06: By. AMA
Community Restrictions:
Side Yard = 5' Minimum on one side
Rear Yard = None
Aggregate = 20% of lot width at
building line.
Zoning = PUO
Note: BuUder to ensure positive
drainage away from structure{s).
)5.73
~
~
~
:l: ....
f:\ ~
z 0.
15
~
'"
i
~
12' ALLEY EASEMENT
----
TC=906.41
PER RECORD
ORA\\ING
--
Sumy\D&
~ ArcbIloclun
GIll'US
GooI'IJ
,
Note: I
This drawing is based on construction plans or record
drawings, and spot elevations obtained in 0 field survey
doted November 30, 2006. The Schneider Corporation '
does not warrant the accuracy or sufficiency of this
information. Contractors should ver'lfy existing conditions
prior to any construction. Any discrepancy found on
this drawing should be reported to The Schneider I
Corporation immediately, faDing to do so results in th~
contractors assumption of all liability.
Note: Per Cormellooing ordintmte 26.\.1 : The I
residential district limits height to twenty-five feet (25'),
however 0 dwelling may be increased in height to I
thirty-five feet (35') pro~ded the side and rear )O'ds
ore increased on odditional one foot (1') for each one
foot (1') the structure exceeds the first twenty-five feet
(25') in height '
Plot Plan Legend
[]QQ]] Proposed Grades
000.0 ExIsting Grades
__ 000.0-- Contour Grade
* Approl<. Lateral Location
_ . _ Sanitary Sewer Unes
_ ar- Storm Sewer Lines
_ IJ - Water Service Lines
_ _ _ _ _ _ _ Sub-Surface Drain lines
. Manhole (Sannory or Storm)
. Beehive Inlet (Storm)
IlIII Curb Inlet (storm)
D End Section (Storm)
... Fire Hydrant
_ 000 _ 000 -Flow Line of swole
_ Bundlng line (BL / BSL)
_ _ _ _ _ - - Easement Line
GLEBE STREET
22'
B-B
BLOCK 0
LOT 1065
U
~
=~=
~
Assumed North
Scole I" = 20'
~.
. ~ ..\ 0\" I
TYPICAL- $WALE SECTION
r CHAIRBACK CURB
RE'i1~ON 11
MOl{!) BUiLDINGS &
ADDED C.O.C.
12-05-06 AMA
8.5'
PER PLAN
RE,^SION #2
RE'i1SED FIT ,\NO
DRIVE SlOPE
12-12-06 AMAjsI<N
RE,^~ON fJ
RE,^SED S,\N. LAT,
FIT/SlOPE ON
1059-1063 ARO
CUENT
05-18-07 Sl<N
..L
5' WALK
..L
s' DU&SE
12' BTL
30.33'
LOTS 1064--1073
Note: Sanitary Sewer
Top of Casting Information
Upstream Manhole, TC= 903.52
Downstream Manhole, TC= 906.41
Non-Bolted Manhole IllO,Existing TC lor=906.30
per record drawing
,..,
,..,
r...:
o
<7>
SLAB ~ ~
FFE=9D7.58~ ~
PROPOSED :l: ....
FRM&MSY f:\ ~
RESIOENCE ~ o.
~
'"
\:j
~
'The driveway slope is 4.1% measured
at the centerline of the driveway
pavement from the edge of teh olley
pavement to the 9arage floor lip at
the building face.
GAR=907.25
THREE CAR
GARAGE
30.33'
CONC.
.... DRIVE
l=-=-~
..
,..,
.n
12' ALLEY EASEMENT
Note:
The cOJ'Itroetor is to mointair. <1 mil'oimum
dlst<1nce of ten feet (10') between the
sanitary sewer and water Hne loterals.
----
FLOOD HAZARD STATEMENT
CERTIFICATION
- '
,\I\lIIIIIIIIIIIII/lJIIIII/'
#""c L ~:/%
#' ~'?,,,"":"...~/(h~
~t...~...;:o\S TEF?i:...... A~
",~.,,~v No 0"'''';0'''
i ( 50303 \) 1
% .... STATE OF ,.: ff
\ ~......livDI A~ t>-.....~ ff
~ '41J....S....U..ii~i\ ~ #
~1Oj, l\' '1..-#
~///IIII/1I1IIIi1i1IIIII\"
"-'-'- l . r-v
ColI
BLOCK ''U''
COMMONS
ColI
----
This drawing is not intended to be represented (lS 0 retrocemen\ or original
boundary survey, a route survey, or a Surveyor Location Report.
Flood Hazard Statement: The accuracy of any flood hazard data shown on this report is subject to
map scale uncertainty and to any other uncertainty in location or elevation on the referenced flood
insurance rate map. ALL of the within described land DOES NOT lie within that special flood hazard
zone AE as said land plots by scale on flood insurance rate map #18057C 0205 F for the City of
Carmel, Indiana dated February 19, 2003.