Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
2023-12-09_Icon Solar Array R3
Annual Production Report produced by Telamon Energy (Confidential) © 2023 Aurora Solar 1 / 3 December 09, 2023 Design 3 Icon on Main, 1025 West Main Street, Carmel, IN 46032 Project Name Icon on Main Project Address 1025 West Main Street, Carmel, IN 46032 Prepared By Telamon Energy (Con dential) mike.morley@telamon.com Report Design Design 3 Module DC Nameplate 133.6 kW Inverter AC Nameplate 93.6 kW Load Ratio: 1.43 Annual Production 175.5 MWh Performance Ratio 83.4% kWh/kWp 1,313.8 Weather Dataset TMY, 10km Grid (39.95,-86.15), NREL (prospector) Simulator Version c7dea92158-bc6525c55f-4923a2eb09- 5afe44b4a6 System Metrics Project Location Monthly Production kW h Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec 0 10k 20k 30k Month GHI (kWh/m ) POA (kWh/m ) Shaded (kWh/m ) Nameplate (kWh) Grid (kWh) January 60.0 74.4 72.8 9,081.5 8,897.7 February 75.7 87.8 87.0 10,898.1 10,465.7 March 110.8 121.9 121.3 15,307.1 14,097.1 April 145.6 153.7 152.9 19,379.1 16,874.6 May 173.1 176.8 175.8 22,308.4 19,174.3 June 185.3 187.2 186.3 23,670.6 20,070.8 July 192.2 195.7 194.6 24,711.5 21,116.5 August 170.7 178.3 177.4 22,520.8 19,317.5 September 141.9 154.0 153.2 19,401.8 16,983.3 October 95.0 108.3 107.7 13,572.1 12,461.9 November 61.0 72.5 71.6 8,959.5 8,399.8 December 52.8 65.0 63.1 7,852.1 7,614.6 2 2 2 Sources of System Loss ShadingShading: 0.8%: 0.8%Shading: 0.8% ReflectionReflection: 3.4%: 3.4%Reflection: 3.4% SoilingSoiling: 2.0%: 2.0%Soiling: 2.0% IrradianceIrradiance: 0.8%: 0.8%Irradiance: 0.8% TemperatureTemperature: 1.4%: 1.4%Temperature: 1.4%MismatchMismatch: 2.6%: 2.6%Mismatch: 2.6% WiringWiring: 0.4%: 0.4%Wiring: 0.4% ClippingClipping: 2.2%: 2.2%Clipping: 2.2% InvertersInverters: 3.6%: 3.6%Inverters: 3.6% AC SystemAC System: 0.9%: 0.9%AC System: 0.9% Annual Production Report produced by Telamon Energy (Confidential) © 2023 Aurora Solar 2 / 3 December 09, 2023 Description Output % Delta Irradiance (kWh/m ) Annual Global Horizontal Irradiance 1,464.2 POA Irradiance 1,575.5 7.6% Shaded Irradiance 1,563.7 -0.8% Irradiance after Re ection 1,510.2 -3.4% Irradiance after Soiling 1,480.0 -2.0% Total Co llecto r Irradiance 1,480.0 0.0% Energy (kWh) Nameplate 197,662.5 Output at Irradiance Levels 196,108.2 -0.8% Output at Cell Temperature Derate 193,360.5 -1.4% Output After Mismatch 188,362.9 -2.6% Optimal DC Output 187,581.6 -0.4% Constrained DC Output 183,543.7 -2.2% Inverter Output 176,978.7 -3.6% Energy to Grid 175,473.7 -0.9% Temperature Metrics Avg. Operating Ambient Temp 13.3 °C Avg. Operating Cell Temp 20.6 °C Simulation Metrics Operating Hours 4679 Solved Hours 4679 Annual Production 2 Description Condition Set 1 Weather Dataset TMY, 10km Grid (39.95,-86.15), NREL (prospector) Solar Angle Location Meteo Lat/Lng Transposition Model Perez Model Temperature Model Sandia Model Temperature Model Parameters Rack Type a b Temperature Delta Fixed Tilt -3.56 -0.075 3°C Flush Mount -2.81 -0.0455 0°C East-West -3.56 -0.075 3°C Carport -3.56 -0.075 3°C Soiling (%) J F M A M J J A S O N D 2 2 2 2 2 2 2 2 2 2 2 2 Irradiation Variance 5% Cell Temperature Spread 4° C Module Binning Range -2.5% to 2.5% AC System Derate 0.50% Trackers Maximum Angle Backtracking 60°Enabled Module Characterizations Module Uploaded By Characterization JAM72S30-530/MR (1000) (JA Solar)HelioScope Spec Sheet Characterization, PAN Component Characterizations Device Uploaded By Characterization Sunny Boy 6.0-US (208V) (SMA)HelioScope Spec Sheet Condition Set Component Name Count Inverters Sunny Boy 6.0-US (208V) (SMA)18 (93.6 kW) Transformer Primary Side: 208Y/120V , Secondary: 208Y/120V 3 AC Panels 6 input AC Panel 3 AC Home Runs 1/0 AWG (Copper) 21 (2,927.8 ft) Strings 10 AWG (Copper) 36 (2,576.9 ft) Module JA Solar, JAM72S30-530/MR (1000) (530W) 252 (133.6 kW) Components Description Combiner Poles String Size Stringing Strategy Wiring Zone -7-7 Along Racking Wiring Zone 2 -7-7 Along Racking Wiring Zone 3 -7-7 Along Racking Wiring Zones Description Racking Orientation Tilt Azimuth Intrarow Spacing Frame Size Frames Modules Power Field Segment 1 Fixed Tilt Landscape (Horizontal)10°179.1°1.6 ft 1x1 84 84 44.5 kW Field Segment 1 (copy) Fixed Tilt Landscape (Horizontal)10°179.1°1.6 ft 1x7 12 84 44.5 kW Field Segment 1 (copy 1) Fixed Tilt Landscape (Horizontal)10°179.1°1.6 ft 1x7 12 84 44.5 kW Field Segments Annual Production Report produced by Telamon Energy (Confidential) © 2023 Aurora Solar 3 / 3 December 09, 2023 Detailed Layout