Loading...
HomeMy WebLinkAboutEP101A - LEVEL 01 ELECTRICAL PLAN-AREA AF S S S FA C P J J J J J J J J J F F F F F F F FFF F F F F J S S S S F S F S S S S S S S J J F J J J 1 1 1 1 1 1 1 1 1 SPRINKLER 111 DOG WASH 110 OFFICE 109 RESTROOM 107 JAN. 108 MAINTENANCE SHOP 101 MDF 104 VEST 105 Elec & Data 102 11 UH-1 UH-2 UH-2 CAS-1A UH-3 HP-1 GP2-7 2 3 GP2-13,15 GP2-12,14 3 GP2-10 GP2-8 GP2-9 GP2-9 GP2-17 GP 2 - 17 GP2-19 5 5 5 2 GP2-28,30,32 4 GP2-11 GP2-11 GP2-11 GP2-25,27 6 CAS-2 CAS-3 CAS-4 HP-2 2 GP2-26 UH-1 UH-1 GP2-34 2 7 GP2-36,38 8 9 10 HP-2 CAS-2 9 7 GP2-37,39 GP2-40 GP2-41 GP2-43 GP2-42 GP2-6 GP 2 - 6 GP 2 - 5 GP2-44 GP2-45 GP2-45 1 1 GP2-51 12 12 H1B-6 H1D-10 H1D-11 H1B-5 1 MDF 106 UH-1 CAS-1B CAS-1B 1 11 13 13 UH-1 EF-1 EF-1 EF-1 AR C H I T E C T CL I E N T CO N S U L T A N T PR O J E C T DR A W I N G T I T L E SE A L SH E E T PR O J E C T I N F O RE V I S I O N S 10 1 7 W e s t M a i n S t r e e t Ca r m e l , I N 4 6 0 3 2 22028 05-19-23 PERMIT SET EP101A LE V E L 0 1 E L E C T R I C A L PL A N - A R E A A N 1/8" = 1'-0" LEVEL 01 ELECTRICAL PLAN1 GENERAL NOTES A REFER TO SHEET E-000 FOR GENERAL ELECTRICAL NOTES, SYMBOLS AND ABBREVIATIONS. B REFER TO SHEET E-601 FOR PANEL CIRCUIT SCHEDULES. C ALL EXPOSED CONDUIT MOUNTED BELOW 6'-0" AFF TO BE GRC. USE GALVONIZED EMT ELSEWHERE. D COORDINATE ALL CONDUIT PENETRATIONS BETWEEN LEVELS WITH STRUCTURAL ENGINEER PRIOR TO SLABS BEING POURED. E UTILIZE MOUNTING INSERTS CAST INTO STRUCTURE/SLAB WHERE PRACTICAL. COORDINATE ALL INSERTS AND STRUCTURAL ANCHORS WITH STRUCTURAL ENGINEER PRIOR TO SLABS BEING POURED. SHEET KEYNOTES 1 PROVIDE ROUGH IN AND 1" CONDUIT FOR FUTURE EV CHARGERS ON POWER SHARING MODE .THESE ARE TO BE FED FROM LOADCENTERS FROM ADJACENT CONDOS. 2 PROVIDE 20A,120V,1PH CIRCUIT FOR UH-1. PROVIDE 2#12 AND 1#12 G IN 1/2" CONDUIT. 3 PROVIDE 20A,208V,1PH CIRCUIT FOR UH-2. PROVIDE 2#12 AND 1#12 G IN 1/2" CONDUIT. 4 PROVIDE 35A,208V,3PH CIRCUIT FOR UH-3. PROVIDE 3#8 AND 1#10 G IN 3/4" CONDUIT. 5 THIS DUCTLESS SPLIT IS TO RECEIVE POWER AND BE CONNECTED TO ITS ASSOCIATED HP-1. 6 PROVIDE 40A,208V,1PH CIRCUIT FOR HP-1. PROVIDE 3#8 AND 1#10 G IN 3/4" CONDUIT.THIS IS TO POWER AND BE CONNECTED TP CAS-1A AND CAS-1B. 7 PROVIDE 15A,208V,1PH CIRCUIT FOR HP-2. PROVIDE 2#14 AND 1#14 G IN 1/2" CONDUIT.THIS IS TO POWER AND BE CONNECTED TO CAS-2. 8 THIS DUCTLESS SPLIT IS TO RECEIVE POWER AND BE CONNECTED TO ITS ASSOCIATED HP-3. 9 THIS DUCTLESS SPLIT IS TO RECEIVE POWER AND BE CONNECTED TO ITS ASSOCIATED HP-2. 10 THIS DUCTLESS SPLIT IS TO RECEIVE POWER AND BE CONNECTED TO ITS ASSOCIATED HP-4. 11 PROVIDE ROUGH IN AND 1" CONDUIT FOR FUTURE EV CHARGERS ON POWER SHARING MODE .THESE ARE TO BE FED FROM GP1 PANEL. 12 PIT RECEPTACLE.COORDINATE LOCATION OF DISCONNECT WITH ELEVATOR INSTALLER PRIOR TO ROUGH-IN. 13 PROVIDE 40A/208V/1PH CIRCUIT FOR EV CHARGER TO BE INSTALLED DURING CONSTRUCTION.PROVIDE 2#8 AND 1#10 G IN 1" CONDUIT