HomeMy WebLinkAboutA101 - Overall First Floor PlanUP
UP
UP
A3002
A300 4
A3
0
0
3
A3
0
0
1
P11P7P6P5P4P3P2P1
PA
PB
PC
PD
PC.9
5.4
4
3
BCDEF
GH
JKL
M
NP
Q
P29
P30
P31
P32
P33
P34
5
S
T
UVW
X
Y
Z
21.3
22
21
23
24
AA
BB
25
P24.8
CC
7
P55
P56
6
DD
1
2
AC.5
R
5.8
4.1
3.4
2.7
1.4
C3
348' - 0"
80' - 11 3/8"95' - 6 1/2"13' - 11"
67' - 8 1/4"
80' - 3 1/4"
53' - 9 1/4"13' - 11"119' - 5 1/4"
46'
-
7
3
/
8
"
43' - 10 3/8"45' - 3"
214
'
-
0
5
/
8
"
79' - 9 1/4"80' - 3 1/4"80' - 3 1/4"
206
'
-
1
0
"
94'
-
1
1
1
/
2
"
119
'
-
7
1
/
2
"
Water Elec. &
Data
Ar
e
a
B
2
Ar
e
a
B
1
Area A
Ar
e
a
E
Area E
Ar
e
a
D
Area A
Area D
Ar
e
a
C
2
Ar
e
a
C
1
Area D
Ar
e
a
C
1
Ar
e
a
B
2
CONDO 1 CONDO 1 CONDO 1 CONDO 1 CONDO 1 CONDO 2
CONDO 3
CONDO 3
B2
B1
B1
B1
C2
A3
B1
B1
B1
A1
A1
A2
A1
A1
B1
B1
C2
A3
B1
A2
A1
A1A2A2A2A1
A1
B1
B1
B1
A3
C2
B1
B1
B1
CONDO 1
CONDO 3CONDO 3
75' - 8 7/8"
14
5
'
-
1
1
/
8
"
50' - 6 7/8"
14
5
'
-
1
1
/
8
"
14
5
'
-
1
1
/
8
"
14
5
'
-
1
1
/
8
"
ST-4
BOH
RETAIL R.R
R.R R.R
ST-2
EL-4UtilitiesUtilities
EL-3
Elec.
BOH
ST-3
ST-1
ST-6 ST-7 ST-8
ST-5
EL-1
EL-2
OPEN
LEASING/LOBBY
General Notes
1. The General Contractor shall verify all
conditions at the jobsite. Notify
Architect of any deviations from those
conditions as they are noted on the
drawings.
2. The General Contractor shall
coordinate and schedule all work with
the Owner.
3. The General Contractor is
responsible for compliance with all
state and local building codes and
government regulatory agencies.
4. The General Contractor is to submit
shop drawings, project data, and
samples to Owner/Architect for
approval prior to fabrication of all
millwork and wall finishes.
5. Do not scale any drawings. Any
dimensions are to be obtained from
the Architect if not noted on the
drawings. Refer all questions to the
Architect or Engineer on Record.
6. All dimensions are to C.L. of demising
wall of units and face of framing.
7. The General Contractor shall keep
one set of plans at the jobsite for the
specific purpose of recording actual
construction conditions. Such project
record documents shall be provided
to the Owner upon completion of the
project.
8. The General Contractor shall verify
size, location, and characteristics of
all works and equipment supplied by
the Owner or others with the
manufacturer or supplier prior to the
start of the work.
9. The General Contractor shall see that
all Subcontractors receive complete
working drawings and assume full
responsibility for coordination of
work.
AR
C
H
I
T
E
C
T
CL
I
E
N
T
CO
N
S
U
L
T
A
N
T
PR
O
J
E
C
T
DR
A
W
I
N
G
T
I
T
L
E
SE
A
L
SH
E
E
T
PR
O
J
E
C
T
I
N
F
O
RE
V
I
S
I
O
N
S
21059
12-05-22
DD Set
A101
Ov
e
r
a
l
l
F
i
r
s
t
F
l
o
o
r
Pl
a
n
Ic
o
n
Ol
d
M
e
r
i
d
i
a
n
an
d
M
a
i
n
S
t
r
e
e
t
SCALE: 1" = 20'-0"A101
1 First Floor Plan