HomeMy WebLinkAboutCorrespondencePlan Review - Review Comments Report
Project Name: CRC PZ-2022-00181 DP ADLS - ERS Old Meridian and Main - Mix Use
Workflow Started: 8/31/2022 11:00:44 AM
Report Generated: 02/24/2025 02:25 PM
REF #CYCLE REVIEWED BY TYPE FILENAME DISCUSSION STATUS
1 1 Addressing
Dave McCoy
9/19/22 11:41 AM
Comment
The southernmost building in this development could be addressed off Old
Meridian St, but it might be better for the street coming off Old Meridian St
to be named and the building addressed off that street. Please contact me to
discuss.
Info Only
2 1 Sign Permits
Aliza Shalit
9/19/22 12:55 PM
Comment
Please include any Proposed signage for this Development for review.
Reviewer Response: Aliza Shalit - 6/5/23 11:34 AM
A Sign Package will be required before any signs are
approved for this project. An ADLS Amend filing will be
required when ready. This should include any directional
or incidental signage.
----------------------------------------------------------
Responded by: Chad James - 3/28/23 8:48 AM
I believe this comment has been resolved. We are not
proposing any signage with this permit. A signage
permit will be submitted at a later date.
----------------------------------------------------------
Responded by: Chad James - 12/20/22 4:10 PM
There is no proposed signage with this permit. We will
be providing that at a later date.
Info Only
3 1 Building & Code
Services
Mike Sheeks
9/19/22 11:06 PM
Comment
Do you have a proposed elevation drawing? Thank you, Mike S.
Responded by: Chad James - 6/12/23 7:05 AM
I believe this comment has been resolved
----------------------------------------------------------
Responded by: Chad James - 3/24/23 12:56 PM
I believe this comment has been resolved
----------------------------------------------------------
Responded by: Chad James - 12/20/22 1:28 PM
We have uploaded the most current building elevations
from the architect.
Resolved
REVIEW COMMENTS
Plan Review - Review Comments Report
Project Name: CRC PZ-2022-00181 DP ADLS - ERS Old Meridian and Main - Mix Use
Workflow Started: 8/31/2022 11:00:44 AM
Report Generated: 02/24/2025 02:25 PM
REF #CYCLE REVIEWED BY TYPE FILENAME DISCUSSION STATUS
4 1 Fire
Carmel Fire
9/20/22 8:24 AM
Comment
Two Fire Department Connections are shown on plans. CFD was not made
aware that two fire department connections are needed for project during
previous meetings. Designer needs to contact Fire Marshal Lucas Ray to
discuss the need for two FDC's.
Responded by: Chad James - 12/20/22 4:08 PM
We have removed the second FDC from the plans. The
proposed building (apartments, retail, and condos) will
be served by one (1) FDC. Please refer to the Site Utility
Plan for exact location.
Resolved
5 1 Fire
Carmel Fire
9/20/22 8:24 AM
Comment
PIV's are required on all fire mains leading into buildings.
Responded by: Chad James - 12/20/22 4:09 PM
We are showing a proposed PIV on the fire main right
before it enters the building. Please refer to the Site
Utility Plan for exact location.
Resolved
6 1 Fire
Carmel Fire
9/20/22 8:28 AM
Comment
Submit a full set of hard copy 1/2 scale plans to CFD for review and
comment. The plans can be delivered to: Carmel Fire Dept. 10701 N. College
Ave Indianapolis, IN 46280 Attn: Plan Review
Responded by: Chad James - 12/20/22 4:09 PM
A full set of hard copy 1/2 scale plans were sent to
address indicated on 12/20/2022
Resolved
7 1 Fire
Carmel Fire
9/20/22 8:29 AM
Comment
Submit an emergency vehicle circulation auto turn plan demonstrating fire
apparatus can drive and turn around on the fire apparatus access road on
the south end of the project.
Responded by: Chad James - 12/20/22 4:09 PM
An autoturn exhibit demonstrating that a fire apparatus
can drive and turn around on the fire apparatus access
road on the south end of the project has been
submitted.
Resolved
8 1 Fire
Carmel Fire
9/20/22 8:36 AM
Comment
Section 3312.1 Fire Hydrants shall be fully functional tested and approved
prior to any combustible materials arriving on the construction site.
Responded by: Chad James - 12/20/22 4:09 PM
This note has been added to the Overall Project General
Notes on Sheet C0.1, Note #17
Info Only
9 1 Fire
Carmel Fire
9/20/22 8:38 AM
Comment
Section 3310.1 Required Fire Department Vehicle Access. Approved
asphalt/concrete fire apparatus access roads shall be provided to and
through the construction site during construction. Fire Apparatus access
road must be capable of supporting the weight of fire apparatus and
maintained clear at all times. The west and south fire department vehicle
access roads shall be installed and fully functional prior to vertical
construction.
Responded by: Chad James - 12/20/22 4:10 PM
This note has been added to the Overall Project General
Notes on Sheet C0.1, Note #16
Info Only
Plan Review - Review Comments Report
Project Name: CRC PZ-2022-00181 DP ADLS - ERS Old Meridian and Main - Mix Use
Workflow Started: 8/31/2022 11:00:44 AM
Report Generated: 02/24/2025 02:25 PM
REF #CYCLE REVIEWED BY TYPE FILENAME DISCUSSION STATUS
10 1 Fire
Carmel Fire
9/20/22 8:41 AM
Comment
3313.1 Where required. In buildings required to have standpipes by Section
905.3.1, not less than one standpipe shall be provided for use during
construction. The general contractor shall contact Fire Marshal Lucas Ray to
discuss the location and timing of Standpipe installation.
Responded by: Chad James - 12/20/22 4:10 PM
Stand pipes will be provided during construction. These
are shown on the MEP plans. It has been noted that the
contractor will contact Fire Marshal Lucas Ray to discuss
the location and tiing of standpipe installation.
Info Only
11 1 Vectren Energy
Chad Miller
9/20/22 8:45 AM
Changemark
CenterPoint Energy
Please have the owner or developer call the new service center asap to have
the existing gas services and meters retired before the demo begins. Protect
any existing gas main or service that will not be retired during demo and
construction phases. Will the new buildings have gas? If they do, CenterPoint
Energy will need load information to size the meters. Also we will need a
AutoCAD file.
C1.4 Site Utility Plan.pdf Info Only
12 1 Carmel Information
Systems
Morgan Rinehart
9/21/22 8:59 AM
Comment
Please show which of the existing City fiber connection points will used for
fiber to the parking garage IT Room for camera feeds.
Responded by: Chad James - 1/2/24 6:57 AM
I believe this comment has been resolved. Can we get
this comment changed in projectdox?
----------------------------------------------------------
Responded by: Chad James - 6/12/23 7:06 AM
I believe this comment has been resolved
----------------------------------------------------------
Responded by: Chad James - 3/24/23 12:57 PM
I believe this comment has been resolved
----------------------------------------------------------
Responded by: Chad James - 12/20/22 1:29 PM
We have revised the plans to show the proposed fiber
optic line connecting to the City's line and running to
the building. Please refer to the Site Utility Plan for
general alignment (northeast corner of the building)
Info Only
13 1 Carmel
Redevelopment
Commission
Larysa Glaspie
9/26/22 11:37 AM
Comment
Pending CRC review of architectural plans. Thank you.
Resolved
Plan Review - Review Comments Report
Project Name: CRC PZ-2022-00181 DP ADLS - ERS Old Meridian and Main - Mix Use
Workflow Started: 8/31/2022 11:00:44 AM
Report Generated: 02/24/2025 02:25 PM
REF #CYCLE REVIEWED BY TYPE FILENAME DISCUSSION STATUS
14 1 Transportation
Systems
David Littlejohn
9/27/22 2:04 PM
Changemark
Short term bicycle parking - retail
Section 5.29 of the City's UDO requires short term bicycle parking to be
provided at a rate of 2 spaces (1 rack) for every 5,000 square feet of retail
space. Revise the plans to include at least the minimum number of required
bicycle parking spaces to comply with the UDO. The City's bicycle standards
require bike racks to be an inverted-U or A-frame rack that are to be
installed within 50' of the main entrance(s) of the building. For buildings with
multiple tenants bike racks may be dispersed throughout the site to provide
accessible and convenient bicycle parking for all of the tenants. Please refer
to section 5.29 of the City's UDO for more information.
C1.2 Site Improvements Plan.pdf Responded by: Chad James - 3/28/23 8:49 AM
We have coordinated with David Littlejohn on the
"Bicycle Parking Exhibit" found in the files/architectural
drawings folder. Per email on 3/20/2023, the plan has
been approved.
----------------------------------------------------------
Responded by: Chad James - 2/8/23 6:39 AM
We will follow up up with this information shortly
Resolved
15 1 Transportation
Systems
David Littlejohn
9/27/22 2:04 PM
Changemark
short term bicycle parking - multifamily
Section 5.29 of the City's UDO requires short term bicycle parking to be
provided at a rate of 0,1 spaces for every bedroom in the multifamily
building(s). Revise the plans to include at least the minimum number of
required bicycle parking spaces to comply with the UDO. The City's bicycle
standards require bike racks to be an inverted-U or A-frame rack that are to
be installed within 50' of the main entrance(s) of the building. For buildings
with multiple tenants bike racks may be dispersed throughout the site to
provide accessible and convenient bicycle parking for all of the tenants.
Please refer to section 5.29 of the City's UDO for more information.
C1.2 Site Improvements Plan.pdf Responded by: Chad James - 3/28/23 8:51 AM
We have coordinated with David Littlejohn on the
"Bicycle Parking Exhibit" found in the files/architectural
drawings folder. Per email on 3/20/2023, the plan has
been approved.
----------------------------------------------------------
Responded by: Chad James - 2/8/23 6:39 AM
We will follow up up with this information shortly
Resolved
16 1 Transportation
Systems
David Littlejohn
9/27/22 2:04 PM
Changemark
long term bicycle - multifamily
Section 5.29 of City's UDO encourages long term bicycle parking for
multifamily developments at a rate of 0.5 spaces for every bedroom in units
without a personal garage. If this is already planned to be included with this
project please provide details on how it will be provided. Please refer to
section 5.29 of the City's UDO for more information on long term bicycle
parking.
C1.2 Site Improvements Plan.pdf Responded by: Chad James - 3/28/23 8:51 AM
We have coordinated with David Littlejohn on the
"Bicycle Parking Exhibit" found in the files/architectural
drawings folder. Per email on 3/20/2023, the plan has
been approved.
----------------------------------------------------------
Responded by: Chad James - 2/8/23 6:39 AM
We will follow up up with this information shortly
Resolved
17 1 Transportation
Systems
David Littlejohn
9/27/22 2:05 PM
Changemark
long term bicycle parking - retail
Section 5.29 of City's UDO encourages long term bicycle parking for
multifamily developments at a rate of 1 space for every 12,000 sq ft of retail
space. If this is already planned to be included with this project please
provide details on how it will be provided. Please refer to section 5.29 of the
City's UDO for more information on long term bicycle parking.
C1.2 Site Improvements Plan.pdf Responded by: Chad James - 3/28/23 8:51 AM
We have coordinated with David Littlejohn on the
"Bicycle Parking Exhibit" found in the files/architectural
drawings folder. Per email on 3/20/2023, the plan has
been approved.
----------------------------------------------------------
Responded by: Chad James - 2/8/23 6:39 AM
We will follow up up with this information shortly
Resolved
Plan Review - Review Comments Report
Project Name: CRC PZ-2022-00181 DP ADLS - ERS Old Meridian and Main - Mix Use
Workflow Started: 8/31/2022 11:00:44 AM
Report Generated: 02/24/2025 02:25 PM
REF #CYCLE REVIEWED BY TYPE FILENAME DISCUSSION STATUS
18 1 Transportation
Systems
David Littlejohn
9/27/22 2:08 PM
Changemark
Bicycle parking details
Add bicycle parking to the site improvement keynotes to indicate where
bicycle parking will be included throughout the site. Please provide a detail
for the short term bicycle parking and the long term bicycle parking that will
be included with this project.
C1.2 Site Improvements Plan.pdf Responded by: Chad James - 3/28/23 8:51 AM
We have coordinated with David Littlejohn on the
"Bicycle Parking Exhibit" found in the files/architectural
drawings folder. Per email on 3/20/2023, the plan has
been approved.
----------------------------------------------------------
Responded by: Chad James - 2/8/23 6:39 AM
We will follow up up with this information shortly
Resolved
19 1 Transportation
Systems
David Littlejohn
9/27/22 2:17 PM
Changemark
Off-Street Trail
The City's Bicycle and Pedestrian Plan indicates a proposed off street trail in
this approximate location. Please revise the plans to include this trail to
comply with the City's Bicycle and Pedestrian Plan.
C1.2 Site Improvements Plan.pdf Responded by: Chad James - 3/28/23 8:55 AM
This variance was approved in the BZA hearing on
3/27/2023
----------------------------------------------------------
Responded by: Chad James - 12/20/22 4:11 PM
We have revised the plans to provide an off-street trail
connecting Main Street to the south property line of the
development. A variance request has been submitted to
reduce the width of the off-street path to a 5' wide
sidewalk.
Resolved
20 1 Transportation
Systems
David Littlejohn
9/27/22 2:19 PM
Changemark
Sidewalk connection/crosswalk
Revise the plans to include an ADA compliant accessible route/sidewalk
connection from the interior sidewalk to the sidewalk along the south side of
the building leading to the path along Old Meridian.
C1.2 Site Improvements Plan.pdf Responded by: Chad James - 12/20/22 4:11 PM
An ADA compliant accessible route has been provided
from the interior sidewalk to the sidewalk along the
south side of the building leading to the path along Old
Meridian. Please refer to Sheet C1.2 for proposed
alignment.
Resolved
21 1 Transportation
Systems
David Littlejohn
9/27/22 2:20 PM
Changemark
Sidewalk connection/crosswalk 2
Revise the plans to include an ADA compliant accessible route/sidewalk
connection from the interior sidewalk to the pass through sidewalk between
the two buildings.
C1.2 Site Improvements Plan.pdf Responded by: Chad James - 12/20/22 4:11 PM
An ADA compliant accessible route has been provided
from the interior sidewalk to the pass through sidewalk
between the two buildings. Please refer to Sheet C 1.2
for proposed alignment.
Resolved
Plan Review - Review Comments Report
Project Name: CRC PZ-2022-00181 DP ADLS - ERS Old Meridian and Main - Mix Use
Workflow Started: 8/31/2022 11:00:44 AM
Report Generated: 02/24/2025 02:25 PM
REF #CYCLE REVIEWED BY TYPE FILENAME DISCUSSION STATUS
22 1 Transportation
Systems
David Littlejohn
9/27/22 2:25 PM
Changemark
Urban Commercial Sidewalk
The City's bicycle and pedestrian plan requires a 12 ft wide Urban
Commercial sidewalk for new developments along Old Meridian. at this
location. Revise the plans to include a 12 ft sidewalk along the project's
entire Old Meridian frontage.
C1.2 Site Improvements Plan.pdf Responded by: Chad James - 3/28/23 8:56 AM
This variance was approved in the BZA hearing on
3/27/2023
----------------------------------------------------------
Responded by: Chad James - 12/20/22 4:11 PM
We have requested a variance to allow for a 10' wide
path instead of a 12' wide path.
Resolved
23 1 Transportation
Systems
David Littlejohn
9/27/22 2:26 PM
Changemark
Ramp alignment
Revise this ramp to ensure that it provides a straight crossing to the ramp on
the opposite side and that it complies with ADA standards.
C1.2 Site Improvements Plan.pdf Responded by: Chad James - 12/20/22 4:11 PM
We have updated the ramp location to provide a
straight crossing to the ramp on the opposite side.
Please refer to Sheet C1.2 for proposed alignment.
Resolved
24 1 Transportation
Systems
David Littlejohn
9/27/22 2:27 PM
Changemark
Stop bar location
Move this stop bar so that it aligns with the stop sign and so that it does not
conflict with the crosswalk across the drive.
C1.2 Site Improvements Plan.pdf Responded by: Chad James - 12/20/22 4:11 PM
The stop bar location has been updated so that it does
not conflict with the crosswalk across the draive. Refer
to Sheet C1.2
Resolved
25 1 Transportation
Systems
David Littlejohn
9/27/22 2:31 PM
Changemark
ADA parking in the garage
Please ensure that the parking garage will provide enough ADA parking
spaces to comply with ADA standards. Revise the plans to show where all of
the ADA parking and its accessible route(s) will be located in the garage.
C1.2 Site Improvements Plan.pdf Responded by: Chad James - 12/20/22 4:11 PM
We have confirmed that we are provided enough ADA
parking spaces to comply with ADA standards. We are
providing two near the retail on the west side of the
development. There are also two ADA spaces on each
floor of the garage to give us a total of 12 parking
spaces. Per ADA requirements for 502 spaces, we are
required to provide 12. Please refer to Sheet C1.2 for
the three (3)ADA parking space locations on the first
floor of the garage and throughout the site.
Resolved
Plan Review - Review Comments Report
Project Name: CRC PZ-2022-00181 DP ADLS - ERS Old Meridian and Main - Mix Use
Workflow Started: 8/31/2022 11:00:44 AM
Report Generated: 02/24/2025 02:25 PM
REF #CYCLE REVIEWED BY TYPE FILENAME DISCUSSION STATUS
26 1 Transportation
Systems
David Littlejohn
9/27/22 3:17 PM
Changemark
Stop bar location 2
Move this stop bar so that it aligns with the stop sign and so that it does not
conflict with the crosswalk across the drive.
C1.2 Site Improvements Plan.pdf Responded by: Chad James - 12/20/22 4:12 PM
The stop bar location has been updated so that it does
not conflict with the crosswalk across the draive. Refer
to Sheet C1.2
Resolved
27 1 Engineering
Alex Jordan
9/28/22 11:04 AM
Library Comment
Please provide a legal description of site on the cover sheet
Responded by: Chad James - 12/20/22 3:52 PM
A legal description has been added to the cover sheet.
Resolved
28 1 Engineering
Alex Jordan
9/28/22 11:04 AM
Library Comment
Please submit a storm water management permit application
Responded by: Chad James - 12/20/22 3:52 PM
A stormwater management permit application was
submitted on 12/1/2022
Resolved
29 1 Engineering
Alex Jordan
9/28/22 11:04 AM
Library Comment
Please provide all technical information required by Section 102.02(xi)(m) of
the Storm Water Technical Standards on the grading plan
Responded by: Chad James - 12/20/22 3:52 PM
A drainage summary has been provided on the Grading
Plan (Sheet C1.3).
Resolved
30 1 Engineering
Alex Jordan
9/28/22 11:04 AM
Library Comment
Please verify that there are no direct discharge areas
Responded by: Chad James - 12/20/22 3:52 PM
A variance request has been submitted to allow for the
0.06 acres of grass on the development to continue
drainaing to the exsiting detention basin southeast of
the development.
Resolved
31 1 Engineering
Alex Jordan
9/28/22 11:04 AM
Library Comment
Please clearly show the construction limits on all sheets with plan view (not
required on profile sheets)
Responded by: Chad James - 12/20/22 3:52 PM
We have revised the viewport of the plans to show the
construction limits on all sheets with plan view.
Resolved
Plan Review - Review Comments Report
Project Name: CRC PZ-2022-00181 DP ADLS - ERS Old Meridian and Main - Mix Use
Workflow Started: 8/31/2022 11:00:44 AM
Report Generated: 02/24/2025 02:25 PM
REF #CYCLE REVIEWED BY TYPE FILENAME DISCUSSION STATUS
32 1 Engineering
Alex Jordan
9/28/22 11:04 AM
Library Comment
Please verify that all elevations are North American Vertical Datum of 1988
(NAVD)
Responded by: Chad James - 12/20/22 3:53 PM
We have verified that all elevations are North American
Vertical Datum of 1988 (NAVD).
Resolved
33 1 Engineering
Alex Jordan
9/28/22 11:04 AM
Library Comment
Please verify that the horizontal datum of topgraphic map is Indiana State
Plane Coordinates, NAD83
Responded by: Chad James - 12/20/22 3:56 PM
We have verified that the horizontal datum of
topographic map is Indiana State Plane Coordinates,
NAD83.
Resolved
34 1 Engineering
Alex Jordan
9/28/22 11:04 AM
Library Comment
Please verify that the locations of existing utilities with top of curb and invert
elevations, pipe sizes, and direction are shown
Responded by: Chad James - 12/20/22 3:56 PM
We have verified that the locations of existing utilities
with top of curb and invert elevations, pipe sizes, and
direction are shown on the Existing Conditions Plan
(Sheet C1.0).
Resolved
35 1 Engineering
Alex Jordan
9/28/22 11:04 AM
Library Comment
Please verify that all existing culverts, pipes, and bridges on existing drives or
under the roadway are shown indicating size, type, and invert elevations
Responded by: Chad James - 12/20/22 3:56 PM
We have verified that all existing culverts, pipes, and
bridges are shown in the Existing Conditions Plan (Sheet
C1.0)
Resolved
36 1 Engineering
Alex Jordan
9/28/22 11:04 AM
Library Comment
Please verify that the locations of all existing electrical power vaults,
transformers, power lines, gas lines, television cable , and telephone lines are
shown
Responded by: Chad James - 12/20/22 3:56 PM
We have verified that the locations of all existing
electrical power vaults, transformers, power lines, gas
lines, television cable, and telephone lines are shown in
the Existing Conditions Plan (Sheet C1.0).
Resolved
37 1 Engineering
Alex Jordan
9/28/22 1:33 PM
Changemark
Please show all initial stormwater controls necessary for demolition on this
sheet or provide an initial SWPPP sheet with the next submittal
We will need to see perimeter protection, inlet protection, construction
entrance, etc.
C1.1 Demolition Plan.pdf Responded by: Chad James - 12/20/22 3:56 PM
A Pre-Construction Stormwater Pollution Prevention
Plan Sheet has been added to the Construction
Documents. Please refer to Sheet C1.6
Resolved
Plan Review - Review Comments Report
Project Name: CRC PZ-2022-00181 DP ADLS - ERS Old Meridian and Main - Mix Use
Workflow Started: 8/31/2022 11:00:44 AM
Report Generated: 02/24/2025 02:25 PM
REF #CYCLE REVIEWED BY TYPE FILENAME DISCUSSION STATUS
38 1 Engineering
Alex Jordan
9/28/22 1:33 PM
Changemark
Board of Public Works approval required for closures/restrictions
BPW approval will be required for any roadway or sidewalk
closures/restrictions. A request letter will need to be provided with the next
submittal requesting these items.
C1.1 Demolition Plan.pdf Responded by: Chad James - 12/20/22 4:05 PM
A request letter has been provided with the submittal.
Resolved
39 1 Engineering
Alex Jordan
9/28/22 1:33 PM
Changemark
Please provide a pedestrian maintenance of traffic with the next submittal
A maintenance of traffic was provided for the road closure but we will need
one provided for the duration of when the path is removed.
C1.1 Demolition Plan.pdf Responded by: Chad James - 12/20/22 4:05 PM
A pedestrian maintenance of traffic for the duration of
when the path is removed has been provided with this
submittal. Please refer to sheet C3.1
Resolved
40 1 Engineering
Alex Jordan
9/28/22 2:21 PM
Changemark
The entrances will need to be installed per our standards commercial
entrance detail
Please revise the section of the entrance within the City's right-of-way to
conform with standard drawing 10-22. This detail will also need to be
provided in the plans.
C1.2 Site Improvements Plan.pdf Responded by: Chad James - 12/20/22 4:05 PM
The section of the entrance within the City's right-of-
way has been revised to conform with Standard
Drawing 10-22. The detail has been provided in the
plans on Sheet C8.3. A Variance has been requested for
the 20' curb radius on the northeast entrance of the
project site.
Resolved
41 1 Engineering
Alex Jordan
9/28/22 2:21 PM
Changemark
60' half right-of-way required
Per the Transportation Plan, this section of Main Street is classified as a
parkway arterial street and requires a full right-of-way width of 120'. A 60'
half will need to be dedicated with this project. Please show this on the next
submittal.
C1.2 Site Improvements Plan.pdf Responded by: Chad James - 12/20/22 4:06 PM
A variance request has been submitted to allow for a 40'
half right-of-way instead of a 60' half right of way.
Resolved
42 1 Engineering
Alex Jordan
9/28/22 2:21 PM
Changemark
Multi-use path and urban commercial sidewalk required along frontage
Per the Bicycle and Pedestrian Plan Map in the Transportation Plan, the
proposed concrete sidewalk will need to be revised. A 10' asphalt multi-use
path will be required along the Main Street frontage and an urban
commercial sidewalk is required along the Old Meridian frontage. Please
revise.
C1.2 Site Improvements Plan.pdf Responded by: Chad James - 12/20/22 4:06 PM
A variance request has been submitted to allow for a 10'
concrete multi-use path instead of a 10' asphalt multi-
use path.
Resolved
Plan Review - Review Comments Report
Project Name: CRC PZ-2022-00181 DP ADLS - ERS Old Meridian and Main - Mix Use
Workflow Started: 8/31/2022 11:00:44 AM
Report Generated: 02/24/2025 02:25 PM
REF #CYCLE REVIEWED BY TYPE FILENAME DISCUSSION STATUS
43 1 Engineering
Alex Jordan
9/28/22 2:21 PM
Changemark
A proposed off-street trail is shown in this location on the Bicycle and
Pedestrian Plan Map
This will need to be provided per the Transportation Plan. Please revise the
plans to show this.
C1.2 Site Improvements Plan.pdf Responded by: Chad James - 12/20/22 4:06 PM
We have revised the plans to provide an off-street trail
connecting Main Street to the south property line of the
development. A variance request has been submitted to
reduce the width of the off-street path to a 5' wide
sidewalk.
Resolved
44 1 Engineering
Alex Jordan
9/29/22 9:33 AM
Changemark
The drainage from this portion of the site is being direct to the adjacent
property
The site is being pushed onto the adjacent property and directly towards the
existing building which sits lower than this site. Please revise the grading on
the property line or install storm inlets to collect the drainage.
C1.3 Grading and Drainage Plan.pdf Responded by: Chad James - 12/20/22 4:06 PM
There is a swale diverting a portion of stormwater runoff
to the proposed storm infrastructure. The remaining
portion of drainage from that site is flowing into the
existing detention basin just east of the property
boundary. A variance request has been submitted to
allow for the 0.06 acres to directly discharge into the
existing detention basin.
Resolved
45 1 Engineering
Alex Jordan
9/29/22 11:06 AM
Changemark
The building elevations on these buildings need to be revised
The finished floors and flood protection grades for these buildings are only
0.1' to 0.2' above the local flooding source. We require these elevations for
to 1' above the ponding. Please revise.
C1.5 Emergency Flood Route Plan.pdf Responded by: Chad James - 12/20/22 4:06 PM
The site is too tight to make this requirement work.
We've graded the areas to lower the ponding elevations
as much as possible but we need to maintain ADA
slopes in the plaza and courtyard areas. In doing so we
are not able to meet the 1' requirement. We have
submitted a variance for this request.
Resolved
46 1 Engineering
Alex Jordan
9/29/22 11:06 AM
Changemark
These elevations will need to be raised above the proposed ponding in the
courtyards
These elevations will need to be 1' above the ponding in the courtyards.
C1.5 Emergency Flood Route Plan.pdf Responded by: Chad James - 12/20/22 4:06 PM
Due to the site being so tight and having a lot of
plaza/courtyard area where ADA slopes are required in
all directions, we are not able to get the ponding
elevations 1’ below the finished floor elevations. We
have submitted a variance for this request.
Resolved
Plan Review - Review Comments Report
Project Name: CRC PZ-2022-00181 DP ADLS - ERS Old Meridian and Main - Mix Use
Workflow Started: 8/31/2022 11:00:44 AM
Report Generated: 02/24/2025 02:25 PM
REF #CYCLE REVIEWED BY TYPE FILENAME DISCUSSION STATUS
47 1 Engineering
Alex Jordan
9/29/22 11:26 AM
Changemark
Please show the limits of the underground detention on this and all other
sheets dealing with drainage
C1.6 Stormwater Pollution Prevention
Plan.pdf
Responded by: Chad James - 12/20/22 4:06 PM
We have updated the underground detention linework
to be darker and show up with all other sheets dealing
with drainage.
Resolved
48 1 Engineering
Alex Jordan
9/29/22 11:26 AM
Changemark
Please clearly call out each type of BMP and their sizes
Please also show the BMP easement and access easements on this sheet.
C1.6 Stormwater Pollution Prevention
Plan.pdf
Responded by: Chad James - 12/20/22 4:07 PM
The BMPs have been called out on Sheet C1.7. A 20'
access easement has been added from the R/W to the
BMPs.
Resolved
49 1 Engineering
Alex Jordan
9/29/22 11:26 AM
Changemark
Please provide inlet protection on this inlet
C1.6 Stormwater Pollution Prevention
Plan.pdf
Responded by: Chad James - 12/20/22 4:07 PM
Inlet protection has been provided on the specified
inlet. Please refer the sheet C1.7.
Resolved
50 1 Engineering
Alex Jordan
9/29/22 11:26 AM
Changemark
Where will this be installed?
We are unable to locate this on the plan sheet
C1.6 Stormwater Pollution Prevention
Plan.pdf
Responded by: Chad James - 12/20/22 4:07 PM
There are no native planting areas proposed for the site.
The hatch has been removed from Sheet C 1.7
Resolved
51 1 Engineering
Alex Jordan
9/29/22 11:26 AM
Changemark
Please provide erosion control blanket on this slope
C1.6 Stormwater Pollution Prevention
Plan.pdf
Responded by: Chad James - 12/20/22 4:07 PM
Erosion Control blanket has been added to this area.
Please refer to Sheet C1.7.
Resolved
52 1 Engineering
Alex Jordan
9/29/22 11:27 AM
Changemark
Please extend the construction entrance to be 150' long
C1.6 Stormwater Pollution Prevention
Plan.pdf
Responded by: Chad James - 12/20/22 4:07 PM
The construction entrance has been revised to show 150
feet long. Please refer to sheets C1.6 and C1.7
Resolved
Plan Review - Review Comments Report
Project Name: CRC PZ-2022-00181 DP ADLS - ERS Old Meridian and Main - Mix Use
Workflow Started: 8/31/2022 11:00:44 AM
Report Generated: 02/24/2025 02:25 PM
REF #CYCLE REVIEWED BY TYPE FILENAME DISCUSSION STATUS
53 1 Engineering
Alex Jordan
9/29/22 11:32 AM
Changemark
If any floor drains are proposed within the garage, they will need to be
directed to the sanitary system rather than the storm
C1.4 Site Utility Plan.pdf Responded by: Chad James - 12/20/22 4:07 PM
This has been noted. Design team has confirmed that
the floor drains within the garage will be directed to the
sanitary sewer system.
Resolved
54 1 Engineering
Alex Jordan
9/29/22 1:36 PM
Changemark
Is an appropriate amount of room provided for vehicles to pass here?
C3.0 Maintenance of Traffic Plan.pdf Responded by: Chad James - 12/20/22 4:07 PM
There is approximately 10' of space being provided for
vehicles to pass.
Resolved
55 1 Engineering
Alex Jordan
9/29/22 1:38 PM
Changemark
Please provide the hydraulic grade line on the profiles
C6.0 Storm Plan and Profile.pdf Responded by: Chad James - 12/20/22 4:08 PM
The hydraulic grade line has been added to the profiles
on the Storm Plan & Profile Sheets.
Resolved
56 1 Engineering
Alex Jordan
9/29/22 1:43 PM
Changemark
We require a minimum of 150' construction entrances, please revise
C8.1 Stormwater Pollution Prevention
Details.pdf
Responded by: Chad James - 12/20/22 4:08 PM
The construction entrance detail has been revised.
Resolved
57 1 Engineering
Alex Jordan
9/29/22 2:06 PM
Changemark
Please provide a detail for the water quality diversion structure
Please provide this in the plans and the O&M
C8.3 Construction Details.pdf Responded by: Chad James - 12/20/22 4:08 PM
The StormTrap Site Saver Water Quality Units are online
units, can handle 32.0 cfs, and do not need to
incorporate a diversion structure (confirmed by
stormtrap themselves). The diversion structure for the
Aqua-Swirl is a standard manhole with one outflow pipe
raised higher than the invert in to divert the first inch of
rainfall to the aqua-swirl. The storm plan and profiles
has this pipe called out for reference.
Resolved
58 1 Engineering
Alex Jordan
9/29/22 2:31 PM
Changemark
What is the TSS removal rate for the "Site Saver"?
C8.9 Construction Details.pdf Responded by: Chad James - 12/20/22 4:08 PM
The site saver has been designed to provide a removal
rate of 92%.
Resolved
Plan Review - Review Comments Report
Project Name: CRC PZ-2022-00181 DP ADLS - ERS Old Meridian and Main - Mix Use
Workflow Started: 8/31/2022 11:00:44 AM
Report Generated: 02/24/2025 02:25 PM
REF #CYCLE REVIEWED BY TYPE FILENAME DISCUSSION STATUS
59 1 Engineering
Alex Jordan
9/29/22 2:43 PM
Changemark
Please provide the City's owner acknowledgement agreement in the O&M
The BMPs for the site will need to be listed on the lines provided. I have
uploaded this document to the correspondence folder.
Old Meridian and Main O&M
Manual.pdf
Responded by: Chad James - 12/20/22 4:08 PM
The City's owner acknowledgement agreement has
been provided in the O&M Manual.
Resolved
60 1 Engineering
Alex Jordan
9/29/22 2:43 PM
Changemark
Please show the BMP and access easement on the site map
Old Meridian and Main O&M
Manual.pdf
Responded by: Chad James - 4/18/23 11:07 AM
We have renamed the easement to be called out as
BMP and Access Easement
----------------------------------------------------------
Reviewer Response: Alex Jordan - 2/27/23 3:10 PM
Thank you for showing the easement but please have it
labeled as a BMP easement as well.
----------------------------------------------------------
Responded by: Chad James - 12/20/22 4:08 PM
A 20' access easement has been added from the R/W to
the BMP.
Resolved
61 1 Urban Forestry
Daren Mindham
9/30/22 10:09 AM
Comment
No landscape plans uploaded. I will wait till next review cycle for landscape
plan review.
Info Only
62 1 CrossRoad
Engineers
Willie Hall
10/3/22 3:46 PM
Changemark
102.02.v.d
Please note that site does not lie within SFHA.
C1.0 Existing Conditions.pdf Responded by: Chad James - 12/20/22 3:47 PM
This note has been added to the Existing Conditions
Plan (Sheet C1.0).
Resolved
63 1 CrossRoad
Engineers
Willie Hall
10/3/22 3:48 PM
Changemark
102.02.vii
Plan and Profile Sheet(s) shall include the hydraulic grade line indicated on
the profiles to demonstrate that the hydraulic grade line remains below the
rim elevation for the design condition. Please include Section 102.02.vii
statement on all P&P sheets.
C6.0 Storm Plan and Profile.pdf Responded by: Chad James - 12/20/22 3:47 PM
The hydraulic grade line has been added to the profiles
on the Storm Plan & Profile Sheets. The statement in
Section 102.02.vii of the City of Carmel Storm Water
Technical Standards Manual has been added to all
Storm Plan & Profile Sheets.
Resolved
Plan Review - Review Comments Report
Project Name: CRC PZ-2022-00181 DP ADLS - ERS Old Meridian and Main - Mix Use
Workflow Started: 8/31/2022 11:00:44 AM
Report Generated: 02/24/2025 02:25 PM
REF #CYCLE REVIEWED BY TYPE FILENAME DISCUSSION STATUS
64 1 CrossRoad
Engineers
Willie Hall
10/3/22 3:51 PM
Changemark
102.02.xi
Please include all information on the Grading and Drainage plan required
per 102.02.xi.
C1.3 Grading and Drainage Plan.pdf Responded by: Chad James - 4/18/23 10:45 AM
We have added information to suffice Section 102.02.xi
a, d, g, h, j, and q.
----------------------------------------------------------
Reviewer Response: Willie Hall - 3/2/23 1:30 PM
Please refer to Ref #125-131.
----------------------------------------------------------
Responded by: Chad James - 12/20/22 3:47 PM
All the information required per 102.02.xi of the City of
Carmel Stormwater Technical Standards Manual has
been provided on the Grading and Drainage Plan Sheet.
Resolved
65 1 CrossRoad
Engineers
Willie Hall
10/3/22 3:55 PM
Changemark
102.02.xiv
The construction plans shall include a Structure Data Table, and, at a
minimum, shall include the following information: structure number
reference, upstream structure number, downstream structure number, top
casting elevation, upstream pipe elevation, downstream pipe elevation, pipe
length, pipe material, pipe size, type of structure and detail reference to type
of structure and any notes related to the structure.
C1.3 Grading and Drainage Plan.pdf Responded by: Chad James - 12/20/22 3:47 PM
We have added structure data tables to the construction
plans. The sanitary structure data table is located on
Sheet C4.0. The storm sewer structure data table is
located on Sheet C6.4.
Resolved
66 1 CrossRoad
Engineers
Willie Hall
10/3/22 4:20 PM
Changemark
102.03.ii.e&f
The stormwater drainage technical report needs to include in the summary
report the proposed design of the drainage control system. Please
summarize information pertinent to outlet orifices, critical elevations,
detention volume required/provided, 48 hour drawdown, and emergency
spillway.
2021-274.Drainage Report.pdf Responded by: Chad James - 12/20/22 3:47 PM
The requested information has been included in the
Drainage Report.
Resolved
67 1 CrossRoad
Engineers
Willie Hall
10/3/22 4:20 PM
Changemark
102.03.ii.h
The stormwater drainage technical report needs to include in the summary
report a narrative and photographic record of the condition of the
downstream receiving system and a report of the expected impact of the
developmentâ??s stormwater runoff or any receiving stream or downstream
property.
2021-274.Drainage Report.pdf Responded by: Chad James - 12/20/22 3:48 PM
The Drainage Report now includes a narrative and
photographic record of the condition of the
downstream receiving system, and expected impacts of
the development's stormwater runoff.
Resolved
Plan Review - Review Comments Report
Project Name: CRC PZ-2022-00181 DP ADLS - ERS Old Meridian and Main - Mix Use
Workflow Started: 8/31/2022 11:00:44 AM
Report Generated: 02/24/2025 02:25 PM
REF #CYCLE REVIEWED BY TYPE FILENAME DISCUSSION STATUS
68 1 CrossRoad
Engineers
Willie Hall
10/3/22 4:20 PM
Changemark
102.03.i.a
Please include offsite drainage reports for watersheds that are routed
through the site including, but not limited to: The Signature, Main St west of
the roundabout and portion of Old Meridian north and south of roundabout,
developments north of Main St between US 31 and Old Meridian that are
routed through the 48" RCP.
2021-274.Drainage Report.pdf Responded by: Chad James - 5/22/23 3:48 PM
We have updated appendix G in the drainage report to
show the drainage area/calculations, confirm that the
48-inch pipe can convey the existing stormwater runoff,
and that the existing channel can convey the
stormwater runoff to the existing 42-inch pipe
downstream of the development.
----------------------------------------------------------
Reviewer Response: Willie Hall - 3/6/23 4:02 PM
The detention basin was part of the St Vincent parking
lot expansion and does not detain all of the runoff from
the NW corner of the intersection. Alex Jordan has
uploaded the drainage report for that project and the
Olivia development on the SW corner along Main Street
to be referenced.
Please provide calculations evaluating all of the runoff
contributing to the proposed 48 inch pipe and provide
calculations showing that the downstream 42" pipe has
sufficient capacity for all of the proposed flow.
----------------------------------------------------------
Responded by: Chad James - 12/20/22 3:48 PM
We have coordinated with the City of Carmel. They do
not have the drainage report for the detention basin
and 48-inch storm pipe that runs from the northwest
side of the roundabout and discharges to the existing
ditch along main street. We have obtained drainage
reports for Rosewalk on Main (Appendix C) and The
Signature (Appendix G).
Resolved
Plan Review - Review Comments Report
Project Name: CRC PZ-2022-00181 DP ADLS - ERS Old Meridian and Main - Mix Use
Workflow Started: 8/31/2022 11:00:44 AM
Report Generated: 02/24/2025 02:25 PM
REF #CYCLE REVIEWED BY TYPE FILENAME DISCUSSION STATUS
69 1 CrossRoad
Engineers
Willie Hall
10/3/22 4:20 PM
Changemark
102.03.i.b
Please include Watershed map showing that all off-site acreage draining
through the site is accommodated, including the fully developed right-of-
way per the City of Carmel Thoroughfare Plan. Please also make note of any
areas to be directly discharge and show that those are subtracted from the
detention allowable release rate.
2021-274.Drainage Report.pdf Responded by: Chad James - 5/22/23 3:49 PM
We have revised the detention calculations to include
half of the ROW on Old Meridian, half of the ROW on
Main Street and a quarter of the round-a-bout. This
appears to be coincide with the calculations that were
done for the Signature and Oliva on Main with their
respective drainage reports.
----------------------------------------------------------
Reviewer Response: Willie Hall - 3/6/23 9:47 AM
Only half of the right of way is included in the proposed
basin map, none of the roundabout is included. please
revise.
----------------------------------------------------------
Responded by: Chad James - 12/20/22 3:48 PM
The Proposed Basin Map and relevant calculations have
been revised to include the fully-developed right-of-
way per the City of Carmel Thoroughfare Plan.
Resolved
70 1 CrossRoad
Engineers
Willie Hall
10/3/22 4:20 PM
Changemark
102.03.i.c.ii
the stormwater drainage technical report needs to include in the detention
calculations the critical pond elevations, including top bank and spillway
elevations.
2021-274.Drainage Report.pdf Responded by: Chad James - 12/20/22 3:48 PM
The critical pond elevations have been added to the
narrative of the drainage report.
Resolved
71 1 CrossRoad
Engineers
Willie Hall
10/3/22 4:20 PM
Changemark
102.03.i.d.xii
Please include full flow velocity
2021-274.Drainage Report.pdf Responded by: Chad James - 12/20/22 3:48 PM
The full flow velocity can be found in the Rational
Method Storm Sewer Calculations in Appendix E of the
Drainage Report.
Resolved
Plan Review - Review Comments Report
Project Name: CRC PZ-2022-00181 DP ADLS - ERS Old Meridian and Main - Mix Use
Workflow Started: 8/31/2022 11:00:44 AM
Report Generated: 02/24/2025 02:25 PM
REF #CYCLE REVIEWED BY TYPE FILENAME DISCUSSION STATUS
72 1 CrossRoad
Engineers
Willie Hall
10/3/22 4:20 PM
Changemark
102.03.i.d
Please include calculations for offsite bypass 48" RCP on north side of site.
2021-274.Drainage Report.pdf Responded by: Chad James - 5/22/23 3:51 PM
We have updated the storm sewer pipe along Main
street to a 48-inch pipe. a hydraulic analysis has been
conducted and can be reviewed in Appendix G of the
drainage report.
----------------------------------------------------------
Reviewer Response: Willie Hall - 3/6/23 4:04 PM
The bypass pipe shall be 48", at a minimum, the same
size as the upstream pipe to which it is being
connected. Please conduct a full hydraulic analysis of
the upstream contributary area to said bypass pipe.
----------------------------------------------------------
Responded by: Chad James - 12/20/22 3:48 PM
Calculations for the offsite bypass 42" RCP on the north
side of the site have been included in Appendix G of the
Drainage Report. Please note, that the drainage report
for the roundabout was not found. Some assumptions
were made regarding the area draining to the detention
basin located on the northwest corner of the round-a-
bout.
Resolved
73 1 CrossRoad
Engineers
Willie Hall
10/3/22 4:22 PM
Changemark
102.03.ii.i
The stormwater drainage technical report needs to include in the summary
report Identification of any other State or Federal water quality permits that
are required for construction activities associated with the ownerâ??s project
site.
2021-274.Drainage Report.pdf Responded by: Chad James - 12/20/22 3:48 PM
A statement has been added to the Introduction Section
of the Drainage Report. The only required permit is the
IDEM CSGP
Resolved
74 1 CrossRoad
Engineers
Willie Hall
10/3/22 4:25 PM
Changemark
102.03.iii.b
Hydrologic and hydraulic computations should be included in the submittal.
These calculations should include, but are not limited to the following: runoff
calculations, stage-discharge relationships, and storage volumes.
2021-274.Drainage Report.pdf Responded by: Chad James - 12/20/22 3:49 PM
All hydrologic and hydraulic computations have been
included in Appendix D of the Drainage Report.
Resolved
Plan Review - Review Comments Report
Project Name: CRC PZ-2022-00181 DP ADLS - ERS Old Meridian and Main - Mix Use
Workflow Started: 8/31/2022 11:00:44 AM
Report Generated: 02/24/2025 02:25 PM
REF #CYCLE REVIEWED BY TYPE FILENAME DISCUSSION STATUS
75 1 CrossRoad
Engineers
Willie Hall
10/3/22 4:45 PM
Changemark
104.02
The buildingâ??s lowest entry elevation that is adjacent to and facing a road
shall be a minimum of 12 inches above the road elevation. Please include
MFPG on this sheet.
C1.3 Grading and Drainage Plan.pdf Responded by: Chad James - 12/20/22 3:49 PM
With the building taking up majority of the site at one
elevation, we are not able to meet this requirement on
the northeast corner of the site. We have submitted a
variance for this request.
Resolved
76 1 CrossRoad
Engineers
Willie Hall
10/3/22 4:48 PM
Changemark
302.06.1
Detention facilities shall be designed in such a manner that a minimum 90%
of the original detention capacity is restored within 48 hours from the start
of the design 100-year storm.
2021-274.Drainage Report.pdf Responded by: Chad James - 12/20/22 3:49 PM
The detention facility is designed to meet this
requirement. Please refer to Appendix D of the Drainage
Report for the 48hr detention storage restoration ICPR
results.
Resolved
77 1 CrossRoad
Engineers
Willie Hall
10/3/22 4:48 PM
Changemark
302.06.2
The 100-year elevation of stormwater detention facilities shall be separated
by not less than 25 feet from any building or structure to be occupied.
C1.3 Grading and Drainage Plan.pdf Responded by: Chad James - 12/20/22 3:49 PM
With the underground detention facility being placed
underneath the proposed parking garage, we are not
able to meet this requirement. A variance has been
submitted for this request.
Resolved
78 1 CrossRoad
Engineers
Willie Hall
10/3/22 4:57 PM
Changemark
302.06.10
Detention basins, assumed full to the 100-year water surface elevation or the
emergency overflow weir elevation, whichever is higher, shall be placed
within a common area either platted or legally described and recorded as a
perpetual stormwater easement. A minimum of fifteen (15) feet horizontally
from the top of bank of the facility, or the 100-year pool if no defined top of
bank is present, shall be dedicated as permanent stormwater easement if the
above-noted boundary of the common area does not extend that far.
C1.3 Grading and Drainage Plan.pdf Responded by: Chad James - 12/20/22 3:49 PM
Utilizing an underground detention facility under the
proposed parking garage, we are not able to meet this
requirement. We have submitted a variance for this
request.
Resolved
Plan Review - Review Comments Report
Project Name: CRC PZ-2022-00181 DP ADLS - ERS Old Meridian and Main - Mix Use
Workflow Started: 8/31/2022 11:00:44 AM
Report Generated: 02/24/2025 02:25 PM
REF #CYCLE REVIEWED BY TYPE FILENAME DISCUSSION STATUS
79 1 CrossRoad
Engineers
Willie Hall
10/3/22 5:06 PM
Changemark
302.06.11
Detention basins shall be designed with an additional ten (10) percent of
available capacity to allow for sediment accumulation resulting from
development and to permit the pond to function for reasonable periods
between cleanings. Basins should be designed to collect sediment and debris
in specific locations, such as a forebay, so that removal costs are kept to a
minimum. For wet-bottom ponds, the sediment allowance may be provided
below the permanent pool elevation. No construction trash or debris shall be
allowed to be placed within the permanent pool. If the pond is used as a
sediment control measure during active construction, the performance
sureties will not be released until sediment has been cleaned out of the pond
and elevations and grades have been re-established as noted in the
accepted plans.
2021-274.Drainage Report.pdf Responded by: Chad James - 12/20/22 3:49 PM
The detention facility is designed to meet this
requirement. When the 100YR storm event maximum
volume is stored in the underground detention basin,
there is still an additional 15% of available capacity to
allow for sediment accumulation. Please refer to
Appendix D of the Drainage Report for ICPR Storage
Volume Results.
Resolved
80 1 CrossRoad
Engineers
Willie Hall
10/3/22 5:06 PM
Changemark
302.06.12
Detention basins shall be sized to detain the runoff from the fully developed
right-of-way per the City of Carmel 20-year Thoroughfare Plan across all
frontages, regardless of existing watershed boundaries or drainage
breaks/divides. The acreage of the full right-of-way width shall be included
in the overall acreage of the development in determining the allowable
release rate.
2021-274.Drainage Report.pdf Responded by: Chad James - 5/22/23 3:51 PM
We have revised the detention calculations to include
half of the ROW on Old Meridian, half of the ROW on
Main Street and a quarter of the round-a-bout. This
appears to be coincide with the calculations that were
done for the Signature and Oliva on Main with their
respective drainage reports.
----------------------------------------------------------
Reviewer Response: Willie Hall - 3/6/23 10:04 AM
Please refer to Ref #69 response.
----------------------------------------------------------
Responded by: Chad James - 12/20/22 3:49 PM
The Proposed Basin Map and relevant calculations have
been revised to include the fully-developed right-of-
way per the City of Carmel Thoroughfare Plan.
Resolved
Plan Review - Review Comments Report
Project Name: CRC PZ-2022-00181 DP ADLS - ERS Old Meridian and Main - Mix Use
Workflow Started: 8/31/2022 11:00:44 AM
Report Generated: 02/24/2025 02:25 PM
REF #CYCLE REVIEWED BY TYPE FILENAME DISCUSSION STATUS
81 1 CrossRoad
Engineers
Willie Hall
10/3/22 5:09 PM
Changemark
302.11
Please include Emergency Overflow calculations per 302.11.
2021-274.Drainage Report.pdf Responded by: Chad James - 4/18/23 10:46 AM
The overflow elevation is for the water going over the
weir, not the water that is in the stormtrap system. The
max stage for the water in the stormtrap system will be
at 847.99. This elevation will generate a flowrate of
40.61 cfs coming out of the 24" outlet pipe. The water
surface elevation over the weir will be at 850.18. This is
1.82' below the parking garage surface elevation
----------------------------------------------------------
Reviewer Response: Willie Hall - 3/6/23 10:11 AM
Please confirm that the overflow elevation of 850.94 will
be below the structure lid by providing OCS detail.
----------------------------------------------------------
Responded by: Chad James - 12/20/22 3:50 PM
Emergency Spillway calculations have been provided in
Appendix D of the Drainage Report.
Resolved
82 1 CrossRoad
Engineers
Willie Hall
10/3/22 5:17 PM
Changemark
303.02
Please verify that this channel can accommodate, as a minimum, peak runoff
from a 10-year return frequency storm calculated based on methodology
described in Section 201.02. If the channel has a capacity of more than 30 cfs
at bank-full stage shall be capable of accommodating peak runoff for a 50-
year return frequency storm within the drainage easement.
C1.4 Site Utility Plan.pdf Responded by: Chad James - 5/22/23 3:53 PM
We have verified that the existing channel can
accommodate peak runoff from a 10-year return
frequency. The channel analysis can be found in
Appendix G of the drainage report.
----------------------------------------------------------
Reviewer Response: Willie Hall - 3/6/23 4:05 PM
This comment will remain unresolved pending the full
evaluation of the upstream watershed.
----------------------------------------------------------
Responded by: Chad James - 12/20/22 3:50 PM
We have verified that the existing channel can
accommodate peak runoff from a 10-year return
frequency storm. Open Channel Calculations can be
found in Appendix E of the Drainage Report.
Resolved
Plan Review - Review Comments Report
Project Name: CRC PZ-2022-00181 DP ADLS - ERS Old Meridian and Main - Mix Use
Workflow Started: 8/31/2022 11:00:44 AM
Report Generated: 02/24/2025 02:25 PM
REF #CYCLE REVIEWED BY TYPE FILENAME DISCUSSION STATUS
83 1 CrossRoad
Engineers
Willie Hall
10/3/22 5:17 PM
Changemark
303.04
Please provide off-site development drainage report to verify existing pipes
have adequate capacity.
C1.3 Grading and Drainage Plan.pdf Responded by: Chad James - 5/22/23 3:54 PM
Please refer to Appendix G for revised off-site drainage
calculations.
----------------------------------------------------------
Reviewer Response: Willie Hall - 3/6/23 10:27 AM
Please refer to Ref #139.
----------------------------------------------------------
Responded by: Chad James - 12/20/22 3:50 PM
We have added Appendix G to the drainage report. This
section provides information for the off-site storm pipes
and assumptions that were made during the analysis.
Resolved
84 1 CrossRoad
Engineers
Willie Hall
10/3/22 5:22 PM
Changemark
303.07
MFPG and FFE shall be minimum of 1' above the local ponding elevation.
C1.5 Emergency Flood Route Plan.pdf Responded by: Chad James - 12/20/22 3:50 PM
Due to the site being so tight and having a lot of
plaza/courtyard area where ADA slopes are required in
all directions, we are not able to get the ponding
elevations 1’ below the finished floor elevations. We
have submitted a variance for this request.
Resolved
85 1 CrossRoad
Engineers
Willie Hall
10/3/22 5:22 PM
Changemark
303.07
Based on proposed elevations on grading plan, the ponding would be
exceed the adjacent grade at the edge of the property behind the inlet.
Ponding shall remain within the limits of the development and not encroach
adjacent properties
C1.5 Emergency Flood Route Plan.pdf Responded by: Chad James - 4/18/23 11:05 AM
We have revised the proposed grading to ensure that all
ponding will be contained on site and remain within the
limits of the development and not encroach adjacent
properties.
----------------------------------------------------------
Reviewer Response: Willie Hall - 3/6/23 10:29 AM
Top of curb elevation still appears to be below ponding
elevation.
----------------------------------------------------------
Responded by: Chad James - 12/20/22 3:50 PM
The grading has been updated so that the ponding
areas remain within the limits of the development, and
flow east towards the existing dry detention facility.
Resolved
Plan Review - Review Comments Report
Project Name: CRC PZ-2022-00181 DP ADLS - ERS Old Meridian and Main - Mix Use
Workflow Started: 8/31/2022 11:00:44 AM
Report Generated: 02/24/2025 02:25 PM
REF #CYCLE REVIEWED BY TYPE FILENAME DISCUSSION STATUS
86 1 CrossRoad
Engineers
Willie Hall
10/3/22 5:39 PM
Changemark
305.05
Please provide spread calcs. The allowable spread of water on Local and
Collector Streets is limited to maintaining a 10-foot moving lane of traffic for
the design storm. An overflow channel/swale between sag inlets and
overflow paths or basin shall be provided at sag inlets so that the maximum
depth of water that might be ponded in the street sag shall not exceed the
top of the curb.
2021-274.Drainage Report.pdf Responded by: Chad James - 12/20/22 3:50 PM
Gutter spread calculations have been provided for all
sag inlets. The inlet capacity calculations show that the
ponding at each inlet does not exceed the top of the
curb (6 inches). Please refer to Appendix G of the
drainage report.
Resolved
87 1 CrossRoad
Engineers
Willie Hall
10/3/22 5:42 PM
Changemark
305.05
ponding limits shall not come into contact with the building
C1.5 Emergency Flood Route Plan.pdf Responded by: Chad James - 12/20/22 3:50 PM
We have revised the grading to ensure that the ponding
limits do not come into contact with the building.
Resolved
88 1 CrossRoad
Engineers
Willie Hall
10/3/22 5:43 PM
Changemark
306.02.D
a minimum 20-foot width easement shall be required as access easement
from a public right-of-way to the facility, unless the pond is immediately next
to a public right-of-way.
C1.4 Site Utility Plan.pdf Responded by: Chad James - 12/20/22 3:50 PM
A 20' access easement has been added from the R/W to
the underground detention facility.
Resolved
89 1 CrossRoad
Engineers
Willie Hall
10/3/22 5:45 PM
Changemark
401.01
subsurface drain shall be Double Wall Hancor Hi-Q or equivalent.
C1.4 Site Utility Plan.pdf Responded by: Chad James - 12/20/22 3:50 PM
This note has been added to the Site Utility Plan (Sheet
C1.4).
Resolved
90 1 CrossRoad
Engineers
Willie Hall
10/3/22 5:48 PM
Changemark
501.01
A minimum of 2.0 feet of vertical separation between storm sewers and
sanitary sewers shall be required. When this is not possible, the sanitary
sewer must be encased in concrete or ductile steel within 5 feet, each side, of
the crossing centerline. There should be no less than 2.5 feet of cover along
any part of the pipe from final pavement elevation or final ground surface
elevation to the top of the pipe.
C6.2 Storm Plan and Profile.pdf Responded by: Chad James - 12/20/22 3:51 PM
We have added callouts to the sanitary plan and profiles
to have the sanitary sewer encased in concrete within 5'
of each side where 2' of vertical separation cannot be
achieved. We have revised the plans to provide at least
2.5 feet of cover.
Resolved
Plan Review - Review Comments Report
Project Name: CRC PZ-2022-00181 DP ADLS - ERS Old Meridian and Main - Mix Use
Workflow Started: 8/31/2022 11:00:44 AM
Report Generated: 02/24/2025 02:25 PM
REF #CYCLE REVIEWED BY TYPE FILENAME DISCUSSION STATUS
91 1 CrossRoad
Engineers
Willie Hall
10/3/22 5:49 PM
Changemark
501.03
manhole/inlet inside sizing shall be according to the Hamilton County
Standard Detail Drawings.
C8.3 Construction Details.pdf Responded by: Chad James - 12/20/22 3:51 PM
We have provided the standard manhole details from
Hamilton County Standard Details Drawings on Sheet
C8.3. However, HCSO does not have any inlet details. In
order to keep everything consistent, we would like keep
the INDOT nomenclature with the understanding that
HCSO specifications will need to be met with each
structure.
Resolved
92 1 CrossRoad
Engineers
Willie Hall
10/3/22 5:51 PM
Changemark
501.03
2 foot sumps are required in the last structure before the detention facility or
wet pond, with the structure placed within 15 feet of the back of curb of a
roadway, and if this structure is a curb inlet and the structure sizing chart
would allow this to be a 2â?? x 2â?? box, it must be upsized to a 48â?
manhole because of the 2â?? sump.
C6.2 Storm Plan and Profile.pdf Responded by: Chad James - 12/20/22 3:51 PM
Two (2) foot sumps were added to the storm structures
upstream of the water quality units. Because the
structures are located in a parking garage, they are
accessible and do not need to be within 15 feet of the
back of curb of a roadway.
Resolved
93 1 CrossRoad
Engineers
Willie Hall
10/3/22 5:56 PM
Changemark
Details
Please include critical elevations on detention cross section. Please include
Carmel standard road section that indicates use of underdrain. Please
indicate how detention will incorporate WQ feature and provide calculations.
C8.6 Construction Details.pdf Responded by: Chad James - 12/20/22 3:51 PM
Critical elevations have been labeled on the detention
cross section on Sheet C8.6. The most up to date Carmel
standard road section that indicates use of underdrain
has been provided on Sheet C8.2. We have included the
stormtrap site saver calculations to the drainage report
in the water quality section.
Resolved
94 1 CrossRoad
Engineers
Willie Hall
10/3/22 5:57 PM
Changemark
501.06.5
Swimming Pool drains shall not be connected to the storm sewers unless the
water is dechlorinated prior to being connected to the storm sewer.
However, water generated from filter backwash shall be directed to the
sanitary sewer system.
C1.4 Site Utility Plan.pdf Responded by: Chad James - 12/20/22 3:51 PM
We have confirmed with the pool designer that the pool
drains will be connected to sanitary. We have shown a
sanitary pressure pipe lateral from the pool to the
sanitary main on the Site Utility Plan.
Resolved
Plan Review - Review Comments Report
Project Name: CRC PZ-2022-00181 DP ADLS - ERS Old Meridian and Main - Mix Use
Workflow Started: 8/31/2022 11:00:44 AM
Report Generated: 02/24/2025 02:25 PM
REF #CYCLE REVIEWED BY TYPE FILENAME DISCUSSION STATUS
95 1 CrossRoad
Engineers
Willie Hall
10/3/22 5:58 PM
Changemark
701.01
WQ structures should be placed ahead of detention. Please provide detail
and calculations for diversion structure.
C1.4 Site Utility Plan.pdf Responded by: Chad James - 4/18/23 11:06 AM
We have updated the drainage report to include the
NJDEP/NJCAT certification/sizing chart
----------------------------------------------------------
Reviewer Response: Willie Hall - 3/6/23 4:06 PM
Please provide additional information confirming that
the Site Savers are sized per NJDEP/NJCAT.
----------------------------------------------------------
Responded by: Chad James - 12/20/22 3:51 PM
We have provided a stormtrap site savers upstream of
the underground detention facility. Diversion
calculations were provided for the diversion structure
for the aqua-swirl. The site saver - 4 has capacity for 32
cfs (which is more than what the pipe can convey) a
diversion structure is not needed for these.
Resolved
96 1 CrossRoad
Engineers
Willie Hall
10/3/22 5:59 PM
Changemark
701.07
20-foot wide access easement from a public right-of-way to each BMP shall
be provided.
C1.4 Site Utility Plan.pdf Responded by: Chad James - 3/28/23 8:45 AM
We have revised the BMP and Access Easement to
encompass all BMPs with at least 10' in each direction.
Please note that there is only 6' from structure 204 to
the proposed column. We have shifted the easement as
far west as we can to center the easement on the BMP
as much as possible.
----------------------------------------------------------
Reviewer Response: Willie Hall - 3/6/23 11:19 AM
Please adjust easement so that each BMP is fully
encompassed by a 20' easement, that the easement
extends at least 10' in each direction.
----------------------------------------------------------
Responded by: Chad James - 12/20/22 3:51 PM
A 20-foot access easement from the right-of-way to
each BMP has been provided.
Resolved
Plan Review - Review Comments Report
Project Name: CRC PZ-2022-00181 DP ADLS - ERS Old Meridian and Main - Mix Use
Workflow Started: 8/31/2022 11:00:44 AM
Report Generated: 02/24/2025 02:25 PM
REF #CYCLE REVIEWED BY TYPE FILENAME DISCUSSION STATUS
97 1 CrossRoad
Engineers
Willie Hall
10/3/22 6:00 PM
Changemark
Detention WQ
Please provide calculations for WQ treatment provided by UG detention.
2021-274.Drainage Report.pdf Responded by: Chad James - 12/20/22 3:52 PM
There is no water quality being provided in the
underground detention facility. The water quality
treatment train consists of site savers upstream of the
detention facility and an aqua-swirl downstream of the
underground detention facility.
Resolved
98 1 CrossRoad
Engineers
Willie Hall
10/3/22 6:02 PM
Changemark
§ 6-198 of Carmel City Code of Ordinances
Filling of the land in the floodplain of a regulated drain or any natural stream
or watercourse, that has a contributing drainage area of 25 acres or more,
located within the City of Carmel is prohibited. The use of the floodplain area
for detention/retention ponds or lakes is also prohibited. Floodplain
boundaries are to be determined by using the 100-year base flood elevation
(BFE) as shown on the flood insurance rate maps (FIRM) of the Federal
Emergency Management Agency (FEMA) and the Hamilton County one-foot
topographic data available on the Hamilton County GIS webpage. (b) If a
FIRM does not establish a 100-year BFE for a regulated drain, natural stream,
or natural watercourse, the 100-year BFE shall be established through a site
specific floodplain study performed by a professional engineer registered in
the State of Indiana in accordance with the IDNR Hydraulic Modeling
Guidelines. (2) If the drainage area for the floodplain study is less then one
square mile at the farthest downstream point of the study, then the
floodplain study must be submitted to the City of Carmel for review and
approval. The City of Carmel will have the option to send the floodplain
study to a consulting engineering firm for review and comment, should the
accuracy of the floodplain study be in question. The cost of the consulting
engineering firm's time will be the responsibility of the owner of the project
and will need to be consented to in a written agreement prior to any review
of the floodplain study by the consulting engineer.
C1.0 Existing Conditions.pdf Reviewer Response: Willie Hall - 3/6/23 5:04 PM
Comment is resolved but the emphasis is that the
proposed bypass pipe has sufficient capacity.
----------------------------------------------------------
Responded by: Chad James - 12/20/22 3:52 PM
No floodplain limits are shown on the FIRM Map.
Resolved
99 1 Carmel Utilities
Lisa Kempa
10/4/22 8:49 AM
Comment
Please send a set of paper plans to Carmel Utilities at 30 W. Main St., Carmel,
IN 46032. Please include water and sewer utility information. Thank you.
Responded by: Chad James - 12/20/22 3:47 PM
a full size paper set of plans were sent to Carmel Utilities
on 12/20/2022
Resolved
100 1 Carmel Water
Operations
Steve Cook
10/10/22 8:27 AM
Changemark
Changemark note #01
contact to discuss design Steve Cook Carmel Water 317-716-3913 thanks,
Steve
C1.4 Site Utility Plan.pdf Responded by: Chad James - 12/20/22 3:45 PM
We have coordinated with Carmel Utilities on design.
Resolved
Plan Review - Review Comments Report
Project Name: CRC PZ-2022-00181 DP ADLS - ERS Old Meridian and Main - Mix Use
Workflow Started: 8/31/2022 11:00:44 AM
Report Generated: 02/24/2025 02:25 PM
REF #CYCLE REVIEWED BY TYPE FILENAME DISCUSSION STATUS
101 2 Carmel Water
Operations
Steve Cook
2/8/23 11:22 AM
Comment
we will need to have discussion on water design for the water main located
on main street prior to approval for plans pre-con/construction
Info Only
102 2 Planning & Zoning
Angie Conn
2/9/23 9:50 AM
Changemark
lot cover %
Please label the lot cover percentage to the site plan. And, please make sure
that it is less than 80%.
C1.2 Site Improvements Plan.pdf Responded by: Chad James - 5/22/23 6:20 AM
We have added a lot cover table in the top right corner
of the site improvement plan. The table reflects 85.8%
impervious cover. It is our understanding that we
received a variance to allow for 86% impervious cover.
Resolved
103 2 Planning & Zoning
Angie Conn
2/9/23 10:18 AM
Changemark
Transportation Plan compliance
As discussed with Brad Schrage, a BZA variance will be filed from UDO
section 1.07 - Compliance with the Transportation Plan.
C1.2 Site Improvements Plan.pdf Responded by: Chad James - 3/28/23 10:05 AM
Variance was approved during 3/27/2023 BZA hearing.
Resolved
104 2 Carmel Utilities
Lisa Kempa
2/9/23 10:30 AM
Comment
Fees will need to be paid
Info Only
105 2 Planning & Zoning
Angie Conn
2/13/23 11:42 AM
Comment
Please upload a Landscape Plan for the Urban Forestry Dept. to review.
Responded by: Chad James - 3/28/23 12:18 PM
We have submitted a planting plan showing the
proposed street trees. The file is located in
Files/Architectural Drawings. This PDF has been
reviewed and approved by the City of Carmel.
Resolved
106 2 Planning & Zoning
Angie Conn
2/13/23 11:43 AM
Changemark
sidewalk
Please continue this sidewalk south and stub it to the south property line.
C1.2 Site Improvements Plan.pdf Responded by: Chad James - 5/22/23 6:17 AM
We have extended the sidewalk to the south and
provided a stubout at the south property line. for future
connection.-
Resolved
107 2 Urban Forestry
Daren Mindham
2/24/23 1:56 PM
Changemark
landscape plan
Please submit a landscape plan for review.
C1.2 Site Improvements Plan.pdf Responded by: Chad James - 3/28/23 12:18 PM
We have submitted a planting plan showing the
proposed street trees. The file is located in
Files/Architectural Drawings. This PDF has been
reviewed and approved by the City of Carmel.
Resolved
Plan Review - Review Comments Report
Project Name: CRC PZ-2022-00181 DP ADLS - ERS Old Meridian and Main - Mix Use
Workflow Started: 8/31/2022 11:00:44 AM
Report Generated: 02/24/2025 02:25 PM
REF #CYCLE REVIEWED BY TYPE FILENAME DISCUSSION STATUS
108 2 Carmel
Redevelopment
Commission
Larysa Glaspie
2/27/23 3:27 PM
Changemark
Changemark note #01, CRC - Loss of brick on elevation
Why is there a loss of brick in this section compared to the elevations
submitted for CRC Architectural Review Committee? The windows in this
section are unaligned - is this intentional?
ERS - Elevations 1.pdf Responded by: Chad James - 1/2/24 6:59 AM
The most current elevations have been submitted to
ProjectDox.
----------------------------------------------------------
Responded by: Chad James - 7/19/23 10:50 AM
Per the last meeting with the CRC, brick has been added
back at intermediate spaces. Metal panel has been
limited to areas corresponding to internal floors or stair
landings.
----------------------------------------------------------
Reviewer Response: Larysa Glaspie - 6/5/23 9:42 AM
Thank you. Please add the brick back in this location.
----------------------------------------------------------
Responded by: Chad James - 5/22/23 3:44 PM
This was intentional. The building had an egress issue.
Due to stairs being required in this location, windows
had to be unaligned.
Resolved
109 2 Carmel
Redevelopment
Commission
Larysa Glaspie
2/27/23 3:35 PM
Changemark
Changemark note #02, CRC - Street Trees
Where will the street trees be located?
C1.2 Site Improvements Plan.pdf Responded by: Chad James - 2/5/25 11:25 AM
I believe this comment has been resolved
----------------------------------------------------------
Responded by: Chad James - 7/19/23 10:52 AM
Street trees have been provided in the planting plans
(overall and enlarged for more detail). this PDF can be
found in File/architectural drawings/Planting Plan.
----------------------------------------------------------
Responded by: Chad James - 3/28/23 9:30 AM
We have submitted a planting plan showing the
proposed street trees. The file is located in
Files/Architectural Drawings. This PDF has been
reviewed and approved by the City of Carmel.
Resolved
Plan Review - Review Comments Report
Project Name: CRC PZ-2022-00181 DP ADLS - ERS Old Meridian and Main - Mix Use
Workflow Started: 8/31/2022 11:00:44 AM
Report Generated: 02/24/2025 02:25 PM
REF #CYCLE REVIEWED BY TYPE FILENAME DISCUSSION STATUS
110 2 Carmel
Redevelopment
Commission
Larysa Glaspie
2/27/23 3:35 PM
Changemark
Changemark note #03, CRC - Number of Parking Spaces
Label the number of parking spaces and bike parking spaces in each area.
C1.2 Site Improvements Plan.pdf Responded by: Chad James - 5/22/23 6:07 AM
We have labeled the number of parking spaces and
bicycle parking spaces in each area. the number is
located within a hexagon.
Resolved
111 2 Carmel
Redevelopment
Commission
Larysa Glaspie
2/27/23 3:35 PM
Changemark
Changemark note #04, CRC - Confirm there is a door/access to/from the
garage to the public plaza
Confirm there is a door/access to/from the garage to the public plaza.
C1.2 Site Improvements Plan.pdf Responded by: Chad James - 3/28/23 12:22 PM
In the northwest corner of the parking garage, there is a
set of double doors that leads to the plaza area in the
northwest corner of the development. There is also a 10'
sidewalk (north of the vehicular entry in the southwest
corner of the garage) that pedestrians can use to access
the plaza.
Resolved
112 2 Carmel
Redevelopment
Commission
Larysa Glaspie
2/27/23 3:35 PM
Changemark
Changemark note #05, CRC - Confirm there is pedestrian access in/out of the
garage here
Confirm there is pedestrian access in/out of the garage here
C1.2 Site Improvements Plan.pdf Responded by: Chad James - 3/28/23 12:42 PM
On the east side of the parking garage there is a 5'
sidewalk that pedestrians can utilize for access in/out of
the garage.
Resolved
113 2 Carmel
Redevelopment
Commission
Larysa Glaspie
2/27/23 3:37 PM
Comment
Where will the public restrooms accessible from the plaza be located?
Responded by: Chad James - 1/2/24 7:00 AM
The most current elevations have been submitted to
ProjectDox.
----------------------------------------------------------
Responded by: Chad James - 7/19/23 10:53 AM
Public restroom signage placement and additional
information to be provided with future signage
package.
----------------------------------------------------------
Reviewer Response: Larysa Glaspie - 6/5/23 9:59 AM
Thank you. Where will the public restroom directional
signage be located?
----------------------------------------------------------
Responded by: Chad James - 5/22/23 6:09 AM
Public restrooms are located in the walk through
between retail and cafe.
Resolved
Plan Review - Review Comments Report
Project Name: CRC PZ-2022-00181 DP ADLS - ERS Old Meridian and Main - Mix Use
Workflow Started: 8/31/2022 11:00:44 AM
Report Generated: 02/24/2025 02:25 PM
REF #CYCLE REVIEWED BY TYPE FILENAME DISCUSSION STATUS
114 2 Carmel
Redevelopment
Commission
Larysa Glaspie
2/27/23 3:37 PM
Comment
Please provide the solar plan for review
Responded by: Chad James - 2/5/25 11:34 AM
We have added the solar plan to ProjectDox. It is
located within the architectural drawings folder.
----------------------------------------------------------
Responded by: Chad James - 7/19/23 10:54 AM
We have added a PDF labeled "Icon Solar Array Plans"
These plans are located in Files/Architectural Plans.
----------------------------------------------------------
Responded by: Chad James - 5/22/23 6:09 AM
This is still being worked on. The solar plan will be
provided for review upon completion.
Resolved
115 2 Carmel
Redevelopment
Commission
Larysa Glaspie
2/27/23 3:38 PM
Comment
Please ensure youre working with Carmel IT on camera locations.
Responded by: Chad James - 5/22/23 6:10 AM
There was a meeting held with CRC and Carmel IT on
March 21st to discuss camera location. We are
continuing to work with Carmel IT to finalize a plan.
Resolved
116 2 Carmel
Redevelopment
Commission
Larysa Glaspie
2/27/23 3:38 PM
Comment
CRC will review the plaza plan when submitted.
Reviewer Response: Larysa Glaspie - 2/12/25 10:16 AM
CRC and developer will continue to work through some
plaza details.
----------------------------------------------------------
Responded by: Chad James - 2/5/25 11:34 AM
We have uploaded the Plaza plan to projectdox. It is
located within the architectural folder.
----------------------------------------------------------
Responded by: Chad James - 7/19/23 11:33 AM
We have added the plaza plans to this submittal. please
refer to the PDF labeled Enlarged Plaza Materials and
Notes Plan-L401 located in the files/architectural plans.
----------------------------------------------------------
Responded by: Chad James - 5/22/23 6:11 AM
The plaza plan(s) will be submitted to CRC upon
completion.
Resolved
Plan Review - Review Comments Report
Project Name: CRC PZ-2022-00181 DP ADLS - ERS Old Meridian and Main - Mix Use
Workflow Started: 8/31/2022 11:00:44 AM
Report Generated: 02/24/2025 02:25 PM
REF #CYCLE REVIEWED BY TYPE FILENAME DISCUSSION STATUS
117 2 Sign Permits
Aliza Shalit
2/28/23 10:04 AM
Changemark
Parking Sign Standards
Please see Correspondence folder for Public Parking Sign Design & Criteria
guide for required signage for City of Carmel Public Parking.
ERS - Elevations 2.pdf Responded by: Chad James - 2/5/25 11:36 AM
Sign Permits will be submitted separately from this
permit.
----------------------------------------------------------
Responded by: Chad James - 7/19/23 10:56 AM
Parking signage has been revised on elevations and civil
plans per discussions with the CRC.
----------------------------------------------------------
Reviewer Response: Aliza Shalit - 6/5/23 11:35 AM
Please include all the parking garage signage with this
ADLS filing. See Public Parking Sign Design & Criteria in
the correspondence folder. This item is required at this
stage of planning.
----------------------------------------------------------
Responded by: Chad James - 5/22/23 6:17 AM
This submittal does not include signage approval.
Proposed signs for this project will be submitted at a
later date. All signs are shown for reference only on the
elevations.
Info Only
Plan Review - Review Comments Report
Project Name: CRC PZ-2022-00181 DP ADLS - ERS Old Meridian and Main - Mix Use
Workflow Started: 8/31/2022 11:00:44 AM
Report Generated: 02/24/2025 02:25 PM
REF #CYCLE REVIEWED BY TYPE FILENAME DISCUSSION STATUS
118 2 Sign Permits
Aliza Shalit
2/28/23 10:29 AM
Changemark
Blade Sign
Per UDO Sign Standards Blade signs may only take up to 70% of the Tenant
Sign Pandrel. Please adjust and include height of Spandrel as marked. (plus a
maximum Sign area 75sf)
ERS - Elevations 1.pdf Responded by: Chad James - 7/19/23 10:56 AM
Blade sign has been resized to show compliance with
UDO
----------------------------------------------------------
Reviewer Response: Aliza Shalit - 6/5/23 12:00 PM
Please depict blade sign to comply with the maximum
blade sign per UDO Sign Standards for approval
purposes. See email for a more detailed explanation.
----------------------------------------------------------
Responded by: Chad James - 5/22/23 6:16 AM
This submittal does not include signage approval.
Proposed signs for this project will be submitted at a
later date. All signs are shown for reference only on the
elevations.
Resolved
119 2 Sign Permits
Aliza Shalit
2/28/23 10:31 AM
Comment
All Signs require a Sign Permit Application & Review Process. Please apply
using our online Permitting Sign at www.carmeldocs.com.
Info Only
120 2 Sign Permits
Aliza Shalit
2/28/23 10:33 AM
Comment
A Sign Package will be required before Sign Permit Applications are
approved. Please submit one during the DP ADLS Process if possible,
otherwise an ADLS Amend will be required before permitting. Sign Package
should include sign locations, sign types, lighting method, and Mounting
requirements.
Info Only
121 2 Sign Permits
Aliza Shalit
2/28/23 10:33 AM
Comment
Please include Addressing number location
Responded by: Chad James - 5/22/23 6:16 AM
The elevation plans have been updated to show the
location(s) of the addressing number.
Resolved
Plan Review - Review Comments Report
Project Name: CRC PZ-2022-00181 DP ADLS - ERS Old Meridian and Main - Mix Use
Workflow Started: 8/31/2022 11:00:44 AM
Report Generated: 02/24/2025 02:25 PM
REF #CYCLE REVIEWED BY TYPE FILENAME DISCUSSION STATUS
122 2 Engineering
Alex Jordan
3/2/23 11:11 AM
Changemark
How will this work be completed due to the structures being within the
garage?
Old Meridian and Main O&M
Manual.pdf
Responded by: Chad James - 5/22/23 6:24 AM
When located in a parking garage, there are a couple of
different options for maintenance: for the nets: 1. tripod
and a winch. 2. small enough forklift or bobcat. For
maintenance of the sediment: 1. cleaning companies
have a trailer bed option just for situations like this. 2.
hose extension for a normal vac truck.
Resolved
123 2 Engineering
Alex Jordan
3/2/23 11:24 AM
Changemark
Please revise this area to remove the callouts regarding the sanitary sewer
Per the demolition review, this will not be removed and the callouts should
be removed.
C1.1 Demolition Plan.pdf Responded by: Chad James - 3/28/23 12:49 PM
Call outs have been removed.
Resolved
124 2 Engineering
Alex Jordan
3/2/23 11:30 AM
Changemark
Please revise this sheet per our comments on the demolition plan set
C1.1 Demolition Plan.pdf Responded by: Chad James - 3/28/23 12:49 PM
The demolition plan uploaded to projectdox is the same
demolition plan provided in the demolition plan set.
Resolved
125 2 CrossRoad
Engineers
Willie Hall
3/2/23 1:29 PM
Changemark
102.02.xi.a
The grading and drainage plan shall include existing drainage facilities,
including size, material, invert elevations and top casting information.
Existing structure and pipe information shall be as-built information and not
design information.
C1.3 Grading and Drainage Plan.pdf Responded by: Chad James - 3/28/23 9:14 AM
We have updated the grading and drainage plan to
show all existing drainage facilities including size,
material, invert elevations and top of casting
information. Existing structure and pipe information was
shot in the field and considered as-built information.
Resolved
126 2 CrossRoad
Engineers
Willie Hall
3/2/23 1:29 PM
Changemark
102.02.xi.d
The grading and drainage plan shall include the delineation of all proposed
land disturbing activities, including off-site activities that will provide services
to the project site.
C1.3 Grading and Drainage Plan.pdf Responded by: Chad James - 5/22/23 3:55 PM
We have added a grey dashed line to delineate the
proposed land disturbing activities.
Resolved
127 2 CrossRoad
Engineers
Willie Hall
3/2/23 1:29 PM
Changemark
102.02.xi.g
The grading and drainage plan shall include the details of all existing streams
and watercourses, and new drainage systems such as culverts, bridges, storm
sewers, sub-surface drains (for both swales and roadways), curbing,
conveyance channels,
C1.3 Grading and Drainage Plan.pdf Responded by: Chad James - 5/22/23 3:56 PM
We have revised C1.3 to include details of all existing
streams and water courses, new drainage systems such
as culverts, bridges, storm sewers, sub-surface drains,
curbing, and conveyance channels.
Resolved
Plan Review - Review Comments Report
Project Name: CRC PZ-2022-00181 DP ADLS - ERS Old Meridian and Main - Mix Use
Workflow Started: 8/31/2022 11:00:44 AM
Report Generated: 02/24/2025 02:25 PM
REF #CYCLE REVIEWED BY TYPE FILENAME DISCUSSION STATUS
128 2 CrossRoad
Engineers
Willie Hall
3/2/23 1:29 PM
Changemark
102.02.xi.h
The grading and drainage plan shall indicate as to the system being public or
private.
C1.3 Grading and Drainage Plan.pdf Responded by: Chad James - 5/22/23 3:57 PM
We have revised the narrative in the bottom right hand
corner of C1.3 to indicate what system is public vs
private.
Resolved
129 2 CrossRoad
Engineers
Willie Hall
3/2/23 1:29 PM
Changemark
102.02.xi.j
The grading and drainage plan shall include the locations of any off-site
drainage swales, ditches and any other facilities that discharge onto the site
of the proposed project.
C1.3 Grading and Drainage Plan.pdf Responded by: Chad James - 5/22/23 3:58 PM
We have updated C1.3 to show off-site drainage swales,
ditches and any other facilities that discharge onto the
site of the proposed project.
Resolved
130 2 CrossRoad
Engineers
Willie Hall
3/2/23 1:29 PM
Changemark
102.02.xi.j
Please include dimensions of detention facility.
C1.3 Grading and Drainage Plan.pdf Responded by: Chad James - 5/22/23 3:59 PM
We have added dimensions of the detention facility on
C1.3.
Resolved
131 2 CrossRoad
Engineers
Willie Hall
3/2/23 1:29 PM
Changemark
102.02.xi.q
The grading and drainage plan shall include drainage arrows indicating all
surface drainage, swales and on each side of every break in swale slopes.
C1.3 Grading and Drainage Plan.pdf Responded by: Chad James - 5/22/23 3:59 PM
We have added flow arrows to C1.3 to show general
direction stormwater runoff will flow at each break.
Resolved
132 2 Engineering
Alex Jordan
3/2/23 3:17 PM
Changemark
Please list the site savers here as well as the water quality units size
C8.0 Stormwater Pollution Prevention
Notes.pdf
Responded by: Chad James - 5/22/23 4:04 PM
We have updated the SWPPP notes to list the site savers
and aqua-swirl
Resolved
134 2 Transportation
Systems
David Littlejohn
3/3/23 12:05 PM
Changemark
Straighten ADA ramp/crosswalk
Relocated the ADA ramp to provide a direct and straight crosswalk to the
receiving ramp on the opposite side of the drive.
C1.2 Site Improvements Plan.pdf Responded by: Chad James - 5/22/23 6:15 AM
We have adjusted the ADA ramp to provide a direct and
straight crosswalk to the receiving ramp on the opposite
side of the drive.
Resolved
135 2 CrossRoad
Engineers
Willie Hall
3/6/23 9:58 AM
Changemark
Existing Pipe
Please include survey data from existing 48" pipe outletting into existing
ditch.
C1.0 Existing Conditions.pdf Responded by: Chad James - 5/22/23 4:00 PM
We have added the upstream invert and pipe invert
information for the existing 48-inch pipe discharging
into the ditch.
Resolved
Plan Review - Review Comments Report
Project Name: CRC PZ-2022-00181 DP ADLS - ERS Old Meridian and Main - Mix Use
Workflow Started: 8/31/2022 11:00:44 AM
Report Generated: 02/24/2025 02:25 PM
REF #CYCLE REVIEWED BY TYPE FILENAME DISCUSSION STATUS
136 2 CrossRoad
Engineers
Willie Hall
3/6/23 10:09 AM
Changemark
Details
Please provide details for OCS and diversion structure.
C6.4 Storm Structure Data Table.pdf Responded by: Chad James - 5/22/23 6:30 AM
Details for the OCS and diversion structure are on Sheet
C8.4.
Resolved
137 2 CrossRoad
Engineers
Willie Hall
3/6/23 10:09 AM
Changemark
Existing Upstream Pipe
Please include existing pipe information that is being connected to Str 500.
C6.4 Storm Structure Data Table.pdf Responded by: Chad James - 5/22/23 6:26 AM
We have revised the structure data table to include the
existing pipe information that is being connected to Str.
500.
Resolved
138 2 CrossRoad
Engineers
Willie Hall
3/6/23 10:26 AM
Changemark
Off-site Drainage
Please provide breakdown of runoff upstream of Str 500. It is unclear from
where the 9.4 cfs is derived since the upstream area is 69.12 acres.
2021-274.Drainage Report.pdf Responded by: Chad James - 5/22/23 4:02 PM
We have revised the calculations, narrative, and added
additional comments to provide clarification on what we
were trying to convey with the proposed calculations on
this sheet. Please refer to Appendix G of the revised
drainage report.
Resolved
139 2 CrossRoad
Engineers
Willie Hall
3/6/23 10:26 AM
Changemark
Signature outflow
Please clarify how offsite runoff numbers are being calculated or reference
where they can be found. Per the Signature drainage report, the 10-year
release rate is 8.86 cfs.
2021-274.Drainage Report.pdf Responded by: Chad James - 5/22/23 4:03 PM
We have revised the calculations, narrative, and added
additional comments to provide clarification on what we
were trying to convey with the proposed calculations on
this sheet. Please refer to Appendix G of the revised
drainage report.
Resolved
140 2 CrossRoad
Engineers
Willie Hall
3/6/23 4:15 PM
Changemark
Roof Runoff
All roof drainage shall be directed to the storm collection facilities. Any
interior drains shall be routed to the sanitary sewer.
2021-274.Drainage Report.pdf Reviewer Response: Willie Hall - 6/8/23 2:55 PM
Per 6/8/23 email from Chad James, the garage drains
shown on the utility Plan Sheet connects the top deck of
the parking garage to the storm sewer.
----------------------------------------------------------
Responded by: Chad James - 5/22/23 6:24 AM
We have updated the inlet basins map to include the
roof drainage from the parking garage. Storm sewer
calcs have been updated accordingly.
Resolved
Plan Review - Review Comments Report
Project Name: CRC PZ-2022-00181 DP ADLS - ERS Old Meridian and Main - Mix Use
Workflow Started: 8/31/2022 11:00:44 AM
Report Generated: 02/24/2025 02:25 PM
REF #CYCLE REVIEWED BY TYPE FILENAME DISCUSSION STATUS
141 3 Carmel Information
Systems
Morgan Rinehart
5/23/23 9:14 AM
Comment
Please show the conduit path from City MDF room to handhole located in
the plaza area.
Responded by: Chad James - 1/2/24 6:58 AM
I believe this comment has been resolved. Can we
change this to resolved in projectdox?
----------------------------------------------------------
Responded by: Chad James - 7/19/23 10:49 AM
We have updated C1.4 Site Utility Plan to show the
conduit path from City MDF room to handhole located
in plaza area.
Info Only
142 3 Carmel
Redevelopment
Commission
Larysa Glaspie
5/31/23 4:03 PM
Comment
Garage IT layout cannot be approved until plaza design is finalized.
Responded by: Chad James - 1/2/24 6:58 AM
I believe this comment has been resolved. Can we
change this to resolved in projectdox?
----------------------------------------------------------
Responded by: Chad James - 7/19/23 11:37 AM
We have added the plaza plans to this submittal. please
refer to the PDF labeled Enlarged Plaza Materials and
Notes Plan-L401 located in the files/architectural plans.
Resolved
143 3 Carmel
Redevelopment
Commission
Larysa Glaspie
6/5/23 10:08 AM
Comment
Submit architecture showing the MDF/IDF layout as discussed in previous
meetings.
Responded by: Chad James - 1/2/24 6:59 AM
The current architectural floor plans have been
submitted to ProjectDox.
----------------------------------------------------------
Responded by: Chad James - 7/19/23 11:01 AM
Electrical plans for the garage have been provided for
reference. These are located in the files/architectural
plans
Resolved
Plan Review - Review Comments Report
Project Name: CRC PZ-2022-00181 DP ADLS - ERS Old Meridian and Main - Mix Use
Workflow Started: 8/31/2022 11:00:44 AM
Report Generated: 02/24/2025 02:25 PM
REF #CYCLE REVIEWED BY TYPE FILENAME DISCUSSION STATUS
144 3 Carmel
Redevelopment
Commission
Larysa Glaspie
6/5/23 11:38 AM
Comment
Work with CRC and Engineering Department to add bollards between the
trees adjacent to the plaza, as noted on the Planting Plan.
Responded by: Chad James - 1/2/24 6:58 AM
I believe this comment has been resolved. Can we
change this to resolved in projectdox?
----------------------------------------------------------
Responded by: Chad James - 12/13/23 10:49 AM
We have coordinated with the engineering department
on locations and spacing. Proposal bollard and type of
bollard are specified on the Site Improvements Plan.
Resolved
145 3 Engineering
Alex Jordan
6/7/23 9:42 AM
Comment
We have no further comments on the plans. Before a stormwater
management permit can be issued, the following items will need to be
submitted: 1. All remaining Crossroad Engineers comments addressed 2. A
signed and recorded O&M manual 3. A right-of-way improvement engineers
estimate stamped by the project engineer 4. A right-of-way improvement
non-expiring performance bond for 100% of the approved estimate 5. An
erosion control engineers estimate stamped by the project engineer 6. An
erosion control non-expiring performance bond for 100% of the approved
estimate 7. A completed BMP easement agreement with legal description
and exhibit (template uploaded to correspondence folder) 8. A right-of-way
permit application and $5,000 license and permit bond
Info Only
146 3 Planning & Zoning
Angie Conn
6/8/23 11:27 AM
Comment
Please upload the floor plans for the buildings and for the parking garage
(for all levels).
Responded by: Chad James - 7/19/23 10:57 AM
All floor plans for the proposed development have been
uploaded to to file/architectural plans folder.
Resolved
147 3 Planning & Zoning
Angie Conn
6/8/23 11:30 AM
Comment
Please upload the overall building square footages. Please also break out the
square footages for retail use, residential use, parking use, etc.
Responded by: Chad James - 7/19/23 10:57 AM
"Gross Square Footage - 641,264 SF
Residential (Apartments) - 372,573 SF
Residential (Condos) - 67,685 SF
Parking Garage - 199,854 SF
Reference Cover Sheet for additional information"
Resolved
148 4 Carmel
Redevelopment
Commission
Larysa Glaspie
12/20/23 11:18 AM
Comment
Please resubmit with the updated architecture as discussed on 12/20/2023.
Responded by: Chad James - 2/5/25 11:35 AM
We have updated the architectural plans as discussed.
Resolved
Plan Review - Review Comments Report
Project Name: CRC PZ-2022-00181 DP ADLS - ERS Old Meridian and Main - Mix Use
Workflow Started: 8/31/2022 11:00:44 AM
Report Generated: 02/24/2025 02:25 PM
REF #CYCLE REVIEWED BY TYPE FILENAME DISCUSSION STATUS
150 4 Sign Permits
Aliza Shalit
12/28/23 10:04 AM
Comment
Sign locations have been provided, if lighting and mounting method are
included at this stage, it will suffice as a sign package, otherwise an ADLS
Amend-Sign will have to be filed for the Sign Package requirement. No sign
permits will be issued until the sign package has been completed.
Reviewer Response: Aliza Shalit - 2/6/25 11:04 AM
Sign Package is still outstanding, An ADLS Amend-Sign
will be required to enter a Sign Package in the record
before any sign permit is issued.
----------------------------------------------------------
Responded by: Chad James - 1/2/24 7:00 AM
This has been noted.
Info Only
151 5 Carmel
Redevelopment
Commission
Larysa Glaspie
2/7/25 11:49 AM
Comment
Signage is not included in this approval. Please submit a sign package for
review.
Info Only
152 5 Carmel
Redevelopment
Commission
Larysa Glaspie
2/12/25 10:13 AM
Comment
CRC and developer will continue to work through some plaza details.
Info Only
153 5 Carmel
Redevelopment
Commission
Larysa Glaspie
2/13/25 10:24 AM
Comment
Cornice will need to be approved by CRC in an onsite mock-up during
construction. Please coordinate with CRC (lglaspie@carmel.in.gov).
Info Only
154 5 Carmel
Redevelopment
Commission
Larysa Glaspie
2/13/25 10:27 AM
Comment
Main Street plaza sign is a placeholder - CRC and developer to work though
plaza signage.
Info Only
155 5 Carmel
Redevelopment
Commission
Larysa Glaspie
2/13/25 10:30 AM
Comment
Approved with conditions – This project is approved pending final approval
from the Carmel Redevelopment Commission. Please contact the CRC
directly for final approval. Henry Mestetsky, Executive Director of the Carmel
Redevelopment Commission, can be reached at hmestetsky@carmel.in.gov
or (317) 443-4679. Signage and murals require a separate ADLS and CRC
review/approval. Please see all Info Only comments. - Cornice will need to be
approved by CRC in an onsite mock-up during construction. Please
coordinate with CRC (lglaspie@carmel.in.gov). - Main Street plaza sign is a
placeholder - CRC and developer to work though plaza signage. - CRC and
developer will continue to work through some plaza details.
Info Only
Confidence in the built environment.
135 N. Pennsylvania Street, Suite 2800
Indianapolis, IN 46204
www.hwcengineering.com
Indianapolis | Hammond | Lafayette | Muncie | New Albany | Terre Haute
www.hwcengineering.com
December 20, 2022
Jeremy Kashman
City Engineer
Department of Engineering
One Civic Square
Carmel, IN 46032
RE: Board of Public Works Request Letter
Old Meridian & Main
Dear Mr. Kashman,
The Old Meridian and Main Development requires approval from the City of Carmel Board of Public Works for
construction and installation for the following items: public storm sewer infrastructure, public roadway
improvements, and public sidewalk improvements.
Public Roadway Improvements
The proposed development will remove the existing curb and gutter on the south side of Main Street, along the
entire frontage for the proposed development and a portion within the existing round-a-bout. Along the south
side of Main Street, ten (10), parallel street parking spaces are being proposed, new curb and gutter will be
installed along the new edge of pavement, and existing pavement south of the centerline will be milled and
overlaid. There will also be a patch of existing asphalt removed and replaced with flush colored concrete. This lines
up with the future median planned for Main Street but allows fire truck access and WB-67 delivery trucks to enter
the proposed eastern driveway into the development. Additional curb and gutter is being removed and replaced
within the limits of the round-a-about. While working with the City of Carmel on the Right-of-way improvements,
it was determined that Main Street would be narrowed to two (2) twelve (12) foot lanes east and west bound on
Main Street at the round-a-bout. In order to ensure a smooth transition to the new curb line for Main street, a
small adjustment was needed in the round-a-bout curb line.
With these proposed improvements, we are proposing to close down east bound Main Street from the
round-a-bout to the western property of the proposed development. A 10’ westbound lane would be maintained
for the entirety of construction within the right-of-way. Please refer to Sheet C3.0 for additional information
regarding the Maintenance of Traffic Plan.
Public Sidewalk Improvements
The proposed development will remove the existing concrete sidewalk and asphalt multi-use path along the entire
frontage of the development (adjacent to Old Meridian, the round-a-bout, and Main Street. In the proposed
conditions there will be a 10-foot concrete multi-use path along the entire frontage of the development. In
addition, existing ADA ramps are being removed and replaced in the same location near the round-a-bout and
proposed ADA ramps will be provided on each side of the proposed drives into the development.
With the proposed improvements, we are proposing to close down the sidewalk along the east side of
Meridian Street and the south side of Main Street for the entirety of construction within and near the right of way.
Please refer to Sheet C3.1 for additional information regarding the Pedestrian Maintenance of Traffic Plan.
Public Storm Sewer Infrastructure
In the existing conditions, there is a roadside ditch (for lack of better words) on the south side of Main Street,
along the entire frontage of the proposed development. This ditch collects and conveys stormwater runoff from
the dry detention basin for the existing round-a-bout, a portion of Main Street inlets, the ultimate outfall point for
the The Signature development (north side of Main Street), and majority of the proposed development’s
stormwater. In order to provide pedestrian access from the proposed building to the on street parking spots, the
roadside ditch is being filled in and a proposed 42-inch storm pipe is being utilized to convey all stormwater runoff
to the ditch east of the proposed development. Due to all of the existing utility infrastructure located along the
south side of Main Street, the constructability of the 42-inch storm line was going to be very difficult. We are
proposing to install the 42-inch line within the edge of pavement along Main Street
If you have any questions or require additional information, please feel free to contact me at your convenience.
Sincerely,
Chad T. James, P.E.
Senior Project Manager
December 20, 2022
Alex Jordan
Plan Review Coordinator
City of Carmel Engineering Department
Carmel City Hall
One Civic Square, Carmel, IN 46032
RE: Variance Request Letter
CRC PZ-2022-00181 DP ADLS ERS Old Meridian and Main – Mix Use
Mr. Jordan,
Per the recent drainage review by City of Carmel for ERS Old Meridian & Main as part of Carmel TAC Meeting, I am
following up with a variance request to the City of Carmel, IN Stormwater Technical Standards Manual and City of
Carmel Comprehensive Plan as listed below:
1. Reference #19 - The City's Bicycle and Pedestrian Plan indicates a proposed off street trail in this
approximate location. Please revise the plans to include this trail to comply with the City's Bicycle and
Pedestrian Plan.
Response: We have revised the plans to provide an off-street path that runs from Old Meridian and
Main, south, through the site. However, due to the site constraints, we are not able to meet the width
of the off-site trail shown in the City’s Bicycle and Pedestrian Plan.
2. Reference #22 - The City's bicycle and pedestrian plan requires a 12 ft wide Urban Commercial
sidewalk for new developments along Old Meridian. at this location. Revise the plans to include a 12 ft
sidewalk along the project's entire Old Meridian frontage.
Response: With this project being a coalition between the CRC, City of Carmel, and Edward Rose and
Sons, we are not able to fit a 12’ wide urban commercial sidewalk along Old Meridian while also
meeting the CRC’s requirements of having a plaza area on the corner of Old Meridian and Main. We
were able to provide a 10’ wide concrete multi-use path along the entire frontage of the property. We
would like to request a variance to reduce the width from 12’ to 10’ for the path along Old Meridian
Street.
3. Reference #30 - Please verify that there are no direct discharge areas
Response: There is a small portion of the site (0.06 acres of grass area only) on the southeast corner
of the development that directly discharges into the existing detention basin on Rose Walk. We have
reviewed the Rose Walk drainage report and they are providing detention for 0.17 acres of the existing
site, consisting mostly of existing paved parking lot). We are reducing the CN value, acreage, and
ultimately the number of cfs directly discharging off-site. Calculations and exhibits can be found in the
revised drainage report. We would like to request a variance to allow for the 0.06 acres of grass area
to continue to discharge to the existing detention basin off-site.
4. Reference #41 - Per the Transportation Plan, this section of Main Street is classified as a parkway
arterial street and requires a full right-of-way width of 120'. A 60' half will need to be dedicated with
this project. Please show this on the next submittal.
Response: With this project being a coalition between the CRC, City of Carmel and Edward Rose and
Sons, we are not able to fit the proposed condos, a 502 public parking garage, apartment building,
and an emergency access for the fire department on the south side of the development while providing
60’ half ROW. We would like to request a variance to allow for a 40’ half ROW along the Main Street
frontage of our property.
5. Reference #42 - Per the Bicycle and Pedestrian Plan Map in the Transportation Plan, the proposed
concrete sidewalk will need to be revised. A 10' asphalt multi-use path will be required along the Main
Street frontage and an urban commercial sidewalk is required along the Old Meridian frontage. Please
revise.
Response: We are currently providing a 10’ concrete multi-use path along Main Street. With the
propose plaza area located on the northwest corner of the development, the developer believes the
area will look more congruent with concrete instead of asphalt and concrete. We would like to request
a variance to provide a 10’ concrete multi-use path instead of asphalt. Please refer to Reference #22
for the variance request regarding the urban commercial sidewalk.
6. Reference #43 - A proposed off-street trail is shown in this location on the Bicycle and Pedestrian Plan
Map. This will need to be provided per the Transportation Plan. Please revise the plans to show this.
Response: We have revised the plans to provide an off-street path that runs from Old Meridian and
Main, south, through the site. However, due to the site constraints, we are not able to meet the width
of the off-site trail shown in the City’s Bicycle and Pedestrian Plan.
7. Reference #45 - The building elevations on these buildings need to be revised
The finished floors and flood protection grades for these buildings are only 0.1' to 0.2' above the local
flooding source. We require these elevations for to 1' above the ponding. Please revise.
Response: Due to the site being so tight and having a lot of plaza/courtyard area where ADA slopes
are required in all directions, we are not able to get the ponding elevations 1’ below the finished floor
elevations. We would like to request a variance for this requirement.
8. Reference #46 - These elevations will need to be raised above the proposed ponding in the courtyards.
These elevations will need to be 1' above the ponding in the courtyards.
Response: Due to the site being so tight and having a lot of plaza/courtyard area where ADA slopes
are required in all directions, we are not able to get the ponding elevations 1’ below the finished floor
elevations. We would like to request a variance for this requirement.
9. Reference #75 - The building’s lowest entry elevation that is adjacent to and facing a road shall be a
minimum of 12 inches above the road elevation.
Response: Due to the site being so tight and having a lot of plaza/courtyard area where ADA slopes
are required in all directions, we are not able to get the building’s FFE 12 inches above the road
elevation at certain locations (mainly the northeast corner of the building). We would like to request a
variance for this requirement.
10. Reference #77 - The 100-year elevation of stormwater detention facilities shall be separated by not
less than 25 feet from any building or structure to be occupied.
Response: With the proposed development utilizing an underground detention facility located
underneath the parking garage, we are not able to provide the 25 foot separation from the proposed
building to the 100-year water surface elevation. We would like to request a variance for this
requirement.
11. Reference #78 - Detention basins, assumed full to the 100-year water surface elevation or the
emergency overflow weir elevation, whichever is higher, shall be placed within a common area either
platted or legally described and recorded as a perpetual stormwater easement. A minimum of fifteen
(15) feet horizontally from the top of bank of the facility, or the 100-year pool if no defined top of bank
is present, shall be dedicated as permanent stormwater easement if the above-noted boundary of the
common area does not extend that far.
Response: With the proposed development utilizing an underground detention facility under the
proposed parking garage, we are not able to meet this requirement. We would like to request a
variance for this requirement.
12. Reference #84 - MFPG and FFE shall be minimum of 1' above the local ponding elevation.
Response: Due to the site being so tight and having a lot of plaza/courtyard area where ADA slopes
are required in all directions, we are not able to get the ponding elevations 1’ below the finished floor
elevations. We would like to request a variance for this requirement.
13. 501.03 – A minimum drop of 0.1 foot through manholes and inlet structures should be provided.
We have provided a 0.1’ drop in all structures that would still provide the minimum 2.5’ of cover over
the pipe. Some runs of pipe do not have the 0.1’ drop in order to meet the minimum cover
requirement, ensure that connections to existing pipes provide positive drainage, or keep the
underground detention facility as low as possible. We would like to request a variance for this
requirement.
In the interim, if you should have any questions, or are in need of additional information, please feel free to contact
me at your convenience.
Sincerely,
Chad T. James, P.E.
Senior Project Manager
1
Chad James
From:McCoy, David W <DMcCoy@carmel.in.gov>
Sent:Thursday, December 1, 2022 12:43 PM
To:Chad James
Cc:Bradley Schrage
Subject:RE: CRC PZ-2022-00181 DP ADLS - ERS Old Meridian and Main Mix Use
Hi Chad,
I was just discussing this with Fire Marshall Lucas Ray and I didn’t realize that this was one large building. So
this project just needs one address, correct?
I would say 1025 W Main St for the address. If you wanted to choose a number it could be any odd number between
1009 and 1041.
What do you think?
David McCoy
GIS Analyst/Addressing Coordinator, City Of Carmel, IN
317-571-2566
From: Chad James <cjames@hwcengineering.com>
Sent: Thursday, December 1, 2022 9:27 AM
To: McCoy, David W <DMcCoy@carmel.in.gov>
Cc: Bradley Schrage <Bradley_Schrage@edwardrose.com>
Subject: CRC PZ-2022-00181 DP ADLS - ERS Old Meridian and Main Mix Use
Good Morning Dave,
We received your comment regarding the address of the building. The developer would like the entire
development to be addressed off Main Street. Is that a possibility with the way the site is laid out?
Thanks,
Chad
Chad James, PE
Senior Project Manager
M: 317-767-1547 | D: 317-419-6767
135 N. Pennsylvania Street, Suite 2800, Indianapolis, IN 46204
HWC Engineering
www.hwcengineering.com
Owner Acknowledgement Agreement (“Agreement”)
For good and valuable consideration, the receipt and sufficiency of which are hereby
acknowledged, the undersigned owner (“Owner”) hereby submits this Operation and
Maintenance Manual (“Manual”) to the City of Carmel, Indiana (“City”) as a written
acknowledgement of Owner’s warranty and agreement to institute, maintain, and follow
the water quality Best Management Practices (“BMPs”) listed below, and to follow and
abide by the inspection schedule and maintenance activities listed in this Manual. The
Owner also hereby agrees to provide, at Owner’s cost, all additional maintenance, repair,
and/or replacement services reasonably necessary to maintain the function and longevity
of the BMPs from and including the date this Agreement is executed by Owner to and
including the date on which a new Agreement is filed with the City by another party who
assumes all of the obligations and responsibilities of Owner as set forth herein.
BMPs: ___________________________________________________
___________________________________________________
___________________________________________________
_______________________________ ________________________
Owner Signature Date
_______________________________ ______________________________
Printed Name Company
STATE OF INDIANA )
) SS:
COUNTY OF HAMILTON )
BEFORE ME, the undersigned, a Notary Public in and for said County and State,
personally appeared _________________________________ Owner subscribed and
sworn before this ____ day of __________________, ________.
______________________________ ______________________________
County of Residence Signature
______________________________
Commission Expiration Date
______________________________
Printed Name
1
Chad James
From:Chad James
Sent:Tuesday, December 20, 2022 11:55 AM
To:Miller, Chad
Subject:CRC PZ-2022-00181 DP ADLS - ERS Old Meridian and Main - Mix Use CAD File
Attachments:ACAD-21274S.zBase.dwg
Good Afternoon Chad,
Attached to this email is the latest CAD file for your use. Please let me know if there are any questions or if any
additional information is needed.
Thanks,
Chad
1
Carmel
Public Parking Sign Design & Criteria
Department of Community Services
CarmelCITYOF
2
Blade Signs
A Blade Sign is the primary sign type used for public parking identification. It is to be located above or near
all garage entrances and must be visible from each approach to the garage. If the entrance to the garage is
not visible from the roadway, additional wayfinding signage is required to direct patrons from the road to the
garage. The exact measurements and color specifications can be found below and must be adhered to.
APPROVED BY
DATE
PAGE 3
Field survey required prior
to fabricaon.
All electrical is configured
to 120V unless otherwise
specified.
The concepts herein are the property of ISF INC. Permission to reproduce, copy or use the design or proposal can only be obtained through written agreement with ISF INC. Due to screen calibration and printing capabilities, the colors shown are only to be used as a close representation or final product.
•DESIGN FABRICATION
isfsigns.com317.251.1219
6468 Rucker Road
•INSTALLATION SERVICE
Indianapolis, IN 46220
DESIGNED BY: CA
REVISED LAST BY: CA
LEFT ELEVATION
SCALE: 3/4”=1’
RIGHT ELEVATION
SCALE: 3/4”=1’
STREET FACING ELEVATION
SCALE: 3/4”=1’
WALL FACING ELEVATION
SCALE: 3/4”=1’
Style and construction
to match existing sign
24”
S4
Fabricate and install (1) 2 sided face lit blade sign
Main Cabinet - .080” aluminum cladding,
.040” returns, & 2” retainer painted
MP 413420 brushed aluminum
Boarder: 1/2” Clear Acrylic Push-thrus w/ second
surface diffuser vinylFace: .090” Aluminum Painted PMS 072C Blue match
w/ routed text and boarder
“P”: 1/2” push through clear acrylic “P” with
second surface diffuser vinyl
Bottom Arm - .080” aluminum cladding,
routed for 1/2” arrow clear acrylic push-thru
w/ second surface diffuser,
Front elevation painted PMS 1245C Yellow, side and back
elevations painted PMS 1245C Yellow, PMS 491C Red
Mounting: Thru-bolt mounted flush via aluminum spacers
painted MP 413420 brushed aluminumIllumination: AVL 6500 white LEDs
SCALE: 1/16”=1’
72
1
/
2
"
56
"
60"
10
3
/
4
"
3 3/4"
9
1
/
4
”
28
1
/
2
”
9 1/4”
2"
31
5
/
8
”
S4
Railyard
Chris Young
Carmel, IN
7-12-2021
rail_5-3119-A_v2
PUBLICPARKING PUBLICPARKING
APPROVED BY
DATE
PAGE 3
Field survey required prior
to fabricaon.
All electrical is configured
to 120V unless otherwise
specified.
The concepts herein are the property of ISF INC. Permission to reproduce, copy or use the design or proposal can only be obtained through written agreement with ISF INC. Due to screen calibration and printing capabilities, the colors shown are only to be used as a close representation or final product.
•DESIGN FABRICATION
isfsigns.com317.251.1219
6468 Rucker Road
•INSTALLATION SERVICE
Indianapolis, IN 46220
DESIGNED BY: CA
REVISED LAST BY: CA
LEFT ELEVATION
SCALE: 3/4”=1’
RIGHT ELEVATION
SCALE: 3/4”=1’
STREET FACING ELEVATION
SCALE: 3/4”=1’
WALL FACING ELEVATION
SCALE: 3/4”=1’
Style and construction
to match existing sign
24”
S4
Fabricate and install (1) 2 sided face lit blade sign
Main Cabinet - .080” aluminum cladding,
.040” returns, & 2” retainer painted
MP 413420 brushed aluminum
Boarder: 1/2” Clear Acrylic Push-thrus w/ second
surface diffuser vinylFace: .090” Aluminum Painted PMS 072C Blue match
w/ routed text and boarder
“P”: 1/2” push through clear acrylic “P” with
second surface diffuser vinyl
Bottom Arm - .080” aluminum cladding,
routed for 1/2” arrow clear acrylic push-thru
w/ second surface diffuser,
Front elevation painted PMS 1245C Yellow, side and back
elevations painted PMS 1245C Yellow, PMS 491C Red
Mounting: Thru-bolt mounted flush via aluminum spacers
painted MP 413420 brushed aluminumIllumination: AVL 6500 white LEDs
SCALE: 1/16”=1’
72
1
/
2
"
56
"
60"
10
3
/
4
"
3 3/4"
9
1
/
4
”
28
1
/
2
”
9 1/4”
2"
31
5
/
8
”
S4
Railyard
Chris Young
Carmel, IN
7-12-2021
rail_5-3119-A_v2
PUBLICPARKING PUBLICPARKING
APPROVED BY
DATE
PAGE 3
Field survey required prior
to fabricaon.
All electrical is configured
to 120V unless otherwise
specified.
The concepts herein are the property of ISF INC. Permission to reproduce, copy or use the design or proposal can only be obtained through written agreement with ISF INC. Due to screen calibration and printing capabilities, the colors shown are only to be used as a close representation or final product.
•DESIGN FABRICATION
isfsigns.com317.251.1219
6468 Rucker Road
•INSTALLATION SERVICE
Indianapolis, IN 46220
DESIGNED BY: CA
REVISED LAST BY: CA
LEFT ELEVATION
SCALE: 3/4”=1’
RIGHT ELEVATION
SCALE: 3/4”=1’
STREET FACING ELEVATION
SCALE: 3/4”=1’
WALL FACING ELEVATION
SCALE: 3/4”=1’
Style and construction
to match existing sign
24”
S4
Fabricate and install (1) 2 sided face lit blade sign
Main Cabinet - .080” aluminum cladding,
.040” returns, & 2” retainer painted
MP 413420 brushed aluminum
Boarder: 1/2” Clear Acrylic Push-thrus w/ second
surface diffuser vinylFace: .090” Aluminum Painted PMS 072C Blue match
w/ routed text and boarder
“P”: 1/2” push through clear acrylic “P” with
second surface diffuser vinyl
Bottom Arm - .080” aluminum cladding,
routed for 1/2” arrow clear acrylic push-thru
w/ second surface diffuser,
Front elevation painted PMS 1245C Yellow, side and back
elevations painted PMS 1245C Yellow, PMS 491C Red
Mounting: Thru-bolt mounted flush via aluminum spacers
painted MP 413420 brushed aluminumIllumination: AVL 6500 white LEDs
SCALE: 1/16”=1’
72
1
/
2
"
56
"
60"
10
3
/
4
"
3 3/4"
9
1
/
4
”
28
1
/
2
”
9 1/4”
2"
31
5
/
8
”
S4
Railyard
Chris Young
Carmel, IN
7-12-2021
rail_5-3119-A_v2
PUBLICPARKING PUBLICPARKING
Created by
"ISF Signs
PMS 1245
(Mustard Yellow)
PMS 431C
(Brick Red)
PMS 072C
(Blue)
2 sided face-lit Blade Sign specs:
Main Cabinet - .080" aluminum cladding,
.040" returns, 2" retainer painted MP
413420 brushed aluminum.
Boarder - ½" Clear Acrylic Push-thrus
with second surface diffuser vinyl
Face - .090" Aluminum Painted PMS
072C Blue match with routed text and
boarder.
"P" - ½" push-thru clear acrylic "P"
with second surface diffuser vinyl.
Bottom Arm - .080" aluminum cladding,
routed for ½" arrow clear acrylic
push-thru with second surface diffuser.
Front elevation painted PMS 1245C
Yellow, side and back elevations painted
PMS 1245C Yellow, PMS 491C Red.
Mounting - Thru-bold mounted flush
via aluminum spacers painted MP
413420 brushed aluminum.
Illumination - AVL 6500 white LEDs.
Left Elevation
Scale: ¾"=1'
Right Elevation
Scale: ¾"=1'
APPROVED BY
DATE
PAGE 3
Field survey required prior
to fabricaon.
All electrical is configured
to 120V unless otherwise
specified.
The concepts herein are the property of ISF INC. Permission to reproduce, copy or use the design or proposal can only be obtained through written agreement with ISF INC. Due to screen calibration and printing capabilities, the colors shown are only to be used as a close representation or final product.
•DESIGN FABRICATION
isfsigns.com317.251.1219
6468 Rucker Road
•INSTALLATION SERVICE
Indianapolis, IN 46220
DESIGNED BY: CA
REVISED LAST BY: CA
LEFT ELEVATION
SCALE: 3/4”=1’
RIGHT ELEVATION
SCALE: 3/4”=1’
STREET FACING ELEVATION
SCALE: 3/4”=1’
WALL FACING ELEVATION
SCALE: 3/4”=1’
Style and construction
to match existing sign
24”
S4
Fabricate and install (1) 2 sided face lit blade sign
Main Cabinet - .080” aluminum cladding,
.040” returns, & 2” retainer painted
MP 413420 brushed aluminum
Boarder: 1/2” Clear Acrylic Push-thrus w/ second
surface diffuser vinylFace: .090” Aluminum Painted PMS 072C Blue match
w/ routed text and boarder
“P”: 1/2” push through clear acrylic “P” with
second surface diffuser vinyl
Bottom Arm - .080” aluminum cladding,
routed for 1/2” arrow clear acrylic push-thru
w/ second surface diffuser,
Front elevation painted PMS 1245C Yellow, side and back
elevations painted PMS 1245C Yellow, PMS 491C Red
Mounting: Thru-bolt mounted flush via aluminum spacers
painted MP 413420 brushed aluminumIllumination: AVL 6500 white LEDs
SCALE: 1/16”=1’
72
1
/
2
"
56
"
60"
10
3
/
4
"
3 3/4"
9
1
/
4
”
28
1
/
2
”
9 1/4”
2"
31
5
/
8
”
S4
Railyard
Chris Young
Carmel, IN
7-12-2021
rail_5-3119-A_v2
PUBLICPARKING PUBLICPARKING
Wall Facing
Elevation
Scale: ¾"=1'
Street Facing
Elevation
Scale: ¾"=1'
3
Wall Signs
When room is available, a wall sign may be used in conjunction with a blade sign. Wall signs must include the
development’s name, “Parking Garage,” and the standard public parking P, as defined on page 7, on both sides
of the name. Doing so communicates to drivers that the garage is public and identifies the development they
will be parking at.
Wall signs are to be flush or pin mounted and the colors and illumination must fit within the context of the
development and surrounding uses.
Example:
4
Suspended & Vinyl Signs
A suspended sign is meant for pedestrians and vehicular drivers as they approach a garage opening.
Hanging from a canopy, it signals vehicles to slow down, as well as for pedestrians to watch for
oncoming traffic. This sign type must include the garage name, the standard public parking P,
and a directional arrow. A red stripe is present at the top of the sign.
Vinyl signage may also be used on canopy faces or garage doors. This sign type is meant as a secondary sign
when a Suspended Sign is unfeasible. This sign type must include the garage name, the standard public
parking P, and any other instructional or wayfinding text.
Carmel P (See specifications page)Background color to match canopyCopy is Arial Bold
65"
8 5"
PMS 491C (Brick Red)
PARKING GARAGE
Canopy Face
PARKING GARAGE
Carmel P (See specifications page)Copy is Arial Bold
8"
5
Digital Signs
Digital signs alert drivers as to exactly how many empty spaces are currently available. The City of Carmel has
two different units currently in use. One shows how many total parking spaces are free, the other one shows
spaces available per category: regular spaces, EV charging spaces, handicap, and in some cases dedicated spaces.
For questions and coordination of digital signage, please contact the Carmel Redevelopment Commission (CRC)
at (317) 819-7207.
6
Entrance &
Directional Signs
Standard Public Parking and Resident Parking Signs
A “Public Parking” header is required above all public vehicle entrances of the parking garage.
This header must be mounted on black metal backing to increase visibility and include
“Public Parking” text, two standard public parking P’s, and the standard lane indicator symbols.
A “Resident Parking Only” header may be used above private vehicle entrances of the parking garage.
This header must be mounted on black metal backing to increase visibility and include
“Resident Parking Only” text and the standard lane indicator symbols.
7
Specs
Public Parking/Resident Parking Only Specifications:
3D Metal Text Font: Arial Bold
White Type on Black Metal Backing
8"13"
13"8"
8½"
1¾" thick
9"
1¾" thick
8"6½"
¼" white border
PMS 186C
(Red)
PMS 368C
(Green)
PMS 072C
(Blue)
"P" Font: Franklin Gothic Heavy
White Type on Blue Background
Red "X": 3D Metal Green Arrow: 3D Metal
Note: The X is recommended to be .5" shorter
than the arrow to match the illusion of size.
Note: Entrance Arrow is purposely shorter arrow.
PMS 13-0630TN
(Yellow)
Note: Pay attention to word tracking
and spread layout for visual balance.
Clearance Bar Font: Franklin Gothic Demi
Black Type on Safety Yellow Plastic Hanging Bar
5"3" Lettering
Main Cabinet Specs:
.080” aluminum cladding, .040” 3” deep returns painted Black
-“P” circles: NON-LIT 1/2” flat cut acrylic digitally printed / UV treated White / (PMS 072C) Oracal 651 printable vinyl on face only
mounted flush to cabinet (non-lit P’s and the circles are not routed copy and are just printed/laminated vinyl on the routed flat circle face)
- Faces routed for 1/2” clear acrylic push-thrus with 2nd surface diffuser vinyl
- “X” has digitally printed / UV treated (PMS 186C) Oracal 651 printable vinyl on face only
- Arrow has digitally printed / UV treated (PMS 368C) Oracal 651 printable vinyl on face only
Backs: .063” aluminum
Illumination: Sloan Prisms White LEDs
Mounting: Thru-bolt mounted flush to brick fascia - depending on thickness of facade stud mounting may be required
Small Public Parking P and Directional Symbol Specifications:
Clearance Bar Specification:
8
Other Exterior Signs
The City will allow signage for public parking to be installed on light poles or as stand alone off-premise signs.
These options are available when locating a particular parking garage has proven difficult for drivers and
additional direction is required.
Under special circumstances the
City will allow uniquely designed
public parking signs. These
sign types should blend with a
building’s architecture or contain
designs and images unique to the
district or surrounding uses.
Pedestrian-scale exterior
signage is required on
all exterior doors to the
garage. This signage
shall include the name
and address of the
parking garage as well
as “Parking Garage” text.
9
Sign Specs
White and black borders
are both 1/2”
3'
1'
-
5
"
7¼
"
7¼
"
2'
Reflective White Paint
Text, Arrow & Borders
on dibond sign face.
Sign face color should
emulate the structure
color it is installed on.
PMS 072C
(Blue)
The City of Carmel public parking symbol is a PMS 072 C
(Blue) circle with a Franklin Gothic Heavy P centered in
the middle. A white ring is also included. If used for
directing traffic a white arrow is included below.
P is Franklin Gothic Heavy
and centered on circle
Sign panel color should
emulate the structure
color it is installed on
PMS 072C
(Blue)
Smaller directional style signs require reflective
white paint text, arrow, and borders.
10
Interior Signs
In addition to exterior signs, the City requires interior signage. Specifically, bicycle parking,
video surveillance, and “No loitering or skateboarding” signs are required.
Additionally, interior wayfinding, directory, and reserved parking signs should be included.
The City recommends a cohesive design throughout the garage. Final design is subject to approval
by the Carmel Redevelopment Commission.
Bike Parking Copy is Arial Bold
PMS 072C
(Blue)
When bike parking is present, directional signage is required.
The public bike parking sign is similar to the public parking
signs, however, the copy Bike Parking and image of a bicycle is
incorporated on the sign. Signs will be installed near entrances and
any other locations to properly direct cyclists to the parking area.
A vector image of the bicycle can be provided upon request.
24-Hour Video Surveillance signs are required when City
cameras are installed in the garage. Signs are installed at
the main entrances to the garage.
Please direct questions to the Carmel Information and
Communications Systems Department (317-571-2567).
11
Interior Signs
1.5" Radius
3/8" Holes
NO
LOITERING
OR
SKATEBOARDING
PERMITTED
Carmel City Code §§6-66; 6-73
18"
1.5"
1.5"
Per Ordinances D-2534-20 and D-2484-19 , skateboarding and loitering are not permitted within public parking
garages. Signage, matching the adjacent specifications, is required to be installed in all public parking garages.
Privately owned public parking garages are not automatically covered by the no loitering and no
skateboarding ordinances. All privately owned public parking garages will need to enter into an Agreement
for Parking and Traffic Regulation on Private Business Property with the City of Carmel to be protected by
Carmel City Code § §6-66; 6-73, allowing police enforcement in the garage. Please work with the Carmel
Redevelopment Commission to execute this agreement.
12
Please direct any questions to the City of Carmel
Department of Community Services (317-571-2417)
or Carmel Redevelopment Commission (317-819-7207)
All Exterior Signs require Sign Permits through the Department of Community Services.
Cross Reference to Deed: xxxx-xxxxxx
GRANT OF PERPETUAL STORM WATER QUALITY MANAGEMENT EASEMENT
This easement (the “Easement”) is by and between the , (the "Grantor") and the City
of Carmel, Indiana (the “City”), by and through its Board of Public Works & Safety (the “Grantee”)
and shall have as its effective date the later of the date on which Grantor executes this Easement or
the date on which Grantee executes this easement;
WITNESSETH THAT:
WHEREAS, Grantor is the owner of the real estate conveyed by the deed identified in the
cross reference above (the “Real Estate”);
WHEREAS, Grantor intends to on the Real Estate and, in connection with the
construction, development and operation of the private , the City has approved or will
approve a Storm Water Management Permit (the “Permit”); and,
WHEREAS, the City requires this Easement in order to verify and require compliance with
the terms and conditions of the Permit and all ordinances of the City applicable to storm water
drainage and storm water quality management (collectively the “Ordinances”).
NOW, THEREFORE, in consideration of the mutual covenants herein set forth and other
good and valuable consideration, the receipt of which is hereby acknowledged, the Grantor
hereby grants to the Grantee a non-exclusive, perpetual easement on the terms and conditions
that follow:
Section 1. Easement Area. The portion of Real Estate on, under and through which this
Easement exists is legally described and graphically depicted in what is attached hereto and
incorporated herein by reference as Exhibits “A” in two parts (the “Easement Area”).
Section 2. Storm Water Quality System. Located or to be located within the Easement Area, in
the manner and areas specified in the Permit, is certain drainage and storm water quality
infrastructure, which may include, without limitation, pervious pavement, manholes, infiltration
basins, pipes, and structural and non-structural best management practices (collectively the
“Storm Water Quality System”) to be constructed, installed and maintained by Grantor, at
Grantor’s expense, in accordance with the Permit and the Ordinances.
Section 3. Purpose of Easement. Grantee shall be and hereby is permitted at all times to enter
upon the Easement Area for purposes of (i) accessing, inspecting, examining, monitoring, testing
and sampling the Storm Water Quality System, and (ii) identifying and verifying compliance
with the requirements of the Permit and the Ordinances.
Section 4. Maintenance and Repair. It shall be Grantor’s obligation to maintain in proper
working order and to repair and/or replace the Storm Water Quality System, or parts thereof,
such that (i) the effectiveness and performance of the Storm Water Quality System is not
diminished from the capabilities set forth in the Permit and (ii) the Storm Water Quality System
remains in compliance with the Permit and the Ordinances.
Section 5. Failure of Storm Water Quality System. In the event that the condition of the Storm
Water Quality System or the outflow therefrom violates or fails to comply with the requirements
set forth in the Permit and/or any of the Ordinances, Grantee shall have the right, but not the
obligation, after providing reasonable notice to Grantor, to perform, at Grantor’s expense, such
maintenance, repair, modification and/or replacement of the Storm Water Quality System as is
necessary to restore compliance with the requirements set forth in the Permit and/or the
Ordinances; provided, however, that the performance by Grantee of any such maintenance,
repair, modification and/or replacement of the Storm Water Quality System shall under no
circumstances relieve Grantor of its responsibility to maintain and operate the Storm Water
Quality System, which responsibility shall be continuous and ongoing.
Section 6. Reimbursement of Expenses and Enforcement. Grantor shall reimburse Grantee for
costs and expenses incurred by Grantee in the performance of the maintenance, repairs,
modifications and/or replacements specified in Section 5 above and, in the event of litigation to
recover such expenses, the prevailing party shall be entitled to recover reasonable attorney’s
fees.
Section 7. Character of Easement. This Easement shall be perpetual and, further, shall inure to
the benefit of and be binding upon the parties’ respective successors and assigns.
Section 8. Use by Grantor and Other Easements. Grantor shall be permitted to use the Easement
Area and also to grant other easements within the Easement Area for any purposes which do not
impair the Storm Water Quality System and which are not inconsistent or conflicting with this
Easement and the Grantee’s rights under this Easement.
Section 9. Amendment. This Easement may be amended only by a written instrument signed (i)
by then owner of the Real Estate and Board of Public Works & Safety of Carmel, Indiana or its
successor or (ii) by an order of a court of competent jurisdiction. In the event that the Real
Estate is later redeveloped and, as such, the site plan made the subject of the Permit is revised,
then the Grantee and then the owner of the Real Estate shall amend this Easement to reconfigure
the Easement Area, accordingly, so that Easement Area is adjusted to and does not conflict with
such revised site plan.
Section 10. Authority. The undersigned person executing this Easement for and on behalf of
Grantor represents and warrants that he or she has been duly authorized by Grantor to execute
and deliver this Easement, and that all actions, votes, approvals and/or restrictions necessary to
allow the execution and delivery of this Easement have been undertaken.
_____________________________________________________________
By:_______________________________
_________________________________ Printed Name
Date: ____________________________
STATE OF INDIANA )
)SS:
COUNTY OF HAMILTON )
Before me, a Notary Public in and for said County and State, personally appeared
_______________________, who acknowledged execution of the foregoing Easement for and
on behalf of _____________________________________.
Witness my hand and Notarial Seal this _________ day of ___________________, 20__.
My Commission Expires: ____________________________________
_____________________ Notary Public
Residing in _______________County ____________________________________
Printed Name
CITY OF CARMEL BOARD OF PUBLIC WORKS & SAFETY
________________________________________
James Brainard, Mayor
Date: __________
________________________________________
Mary Ann Burke, Member
Date: ____________
________________________________________
Lori Watson, Member
Date: ____________
ATTEST:
________________________________________
Sue Wolfgang, Clerk
Date: ____________
STATE OF INDIANA )
)SS:
COUNTY OF HAMILTON )
Before me, a Notary Public in and for said County and State, personally appeared James
Brainard, a member of the City of Carmel, Indiana Board of Public Works & Safety and
acknowledged execution of the foregoing Easement for and on behalf of City of Carmel, Indiana
Board of Public Works & Safety.
Witness my hand and Notarial Seal this _________ day of ___________________, 20__.
My Commission Expires: ____________________________________
_____________________ Notary Public
Residing in _______________County ____________________________________
Printed Name
STATE OF INDIANA )
)SS:
COUNTY OF HAMILTON )
Before me, a Notary Public in and for said County and State, personally appeared Mary
Ann Burke, a member of the City of Carmel, Board of Public Works & Safety and acknowledged
execution of the foregoing Easement for and on behalf of Board of Public Works & Safety.
Witness my hand and Notarial Seal this _________ day of ___________________, 20__.
My Commission Expires: ____________________________________
_____________________ Notary Public
Residing in _______________County ____________________________________
Printed Name
STATE OF INDIANA )
)SS:
COUNTY OF HAMILTON )
Before me, a Notary Public in and for said County and State, personally appeared Lori
Watson, a member of the City of Carmel, Board of Public Works & Safety and acknowledged
execution of the foregoing Easement for and on behalf of City of Carmel Board of Public Works
& Safety.
Witness my hand and Notarial Seal this _________ day of ___________________, 20__.
My Commission Expires: ____________________________________
_____________________ Notary Public
Residing in _______________County ____________________________________
Printed Name
STATE OF INDIANA )
)SS:
COUNTY OF HAMILTON )
Before me, a Notary Public in and for said County and State, personally appeared Sue
Wolfgang, the Clerk of the City of Carmel, Indiana and acknowledged execution of the
foregoing Easement as the Clerk of the City of Carmel, Indiana.
Witness my hand and Notarial Seal this _________ day of ___________________, 20__.
My Commission Expires: ____________________________________
_____________________ Notary Public
Residing in _______________County ____________________________________
Printed Name
Pursuant to IC 36-2-11-15(b)(2), I affirm, under the penalties for perjury, that I have taken
reasonable care to redact each Social Security number in this document, unless required by law –
Jon Oberlander, Esq.
Prepared by: Jon Oberlander, Corporation Counsel, One Civic Square, Carmel, IN 46032
Return to: Jeremy Kashman, P.E., City Engineer, One Civic Square, Carmel, IN 46032