Loading...
HomeMy WebLinkAboutLakefront Court II Sign Package PZ-2025-00029�·: =-;.;;::�� " ,.,,,::l.'::O,=���-· . .:.-••·-· b�E:E1_-,,_�--�=----_ -_ -_ -_ •• :l',1:'1'6'1'1.k�� ..... D<0""'1'->TCttN.,.,. u ..,._,,,,,..., ....... "'.,._..,..,,_.,,,...,..,.,. �ri "'-D"'-""_,.°"'"",,_ R�: �-�=----� .. , '""""'""-_,..........,,.._""""''"" ,., 00tt1,"1CR1.,..,.,.TO"<CT"""' Lakefront Court WEST CARMEL DRIVE CARMEL, INOIANA PRELIMINARY NOT FOR PERMIT OR CONSTRUCTION ELEVATIONS A5.1 Spandrel Area Height = 6'-9" Length = 15'-11" -All signs will be made of individual channel letters -All signs will be facelit or nonlit -All signs will be flush mounted - no raceways -All signs will follow UDO sign standards 2/24/2025 • . "l�-CIHOCMt°"'WING, U"'---1"m'•••ir<otl<r«>""'7T Pff11)0,,"-""'"""""" .. """·'"' .. '° ...,,,...,.,,,""""' ......... '""'""'"'°' l><V$TUl""ll•-••�ru>,_ .,,,... ........... ,.,.,"-' .. ....... ,N......_,.l,.._,.,,,,.10,.,u.o LAKEFRONT COURT 2 PR.RQNMIU.£RANPPR.-KECHE0"" ___ , .. ,.. ..... ""' M"""""""-•lllCTIIICAI.� GrnESIS rnGINEERINGGROUP PRELIMINARY NOT FOR PERMIT OR CONSTRUCTION ISSUE DATE: July7,2022 REVISIONS ELEVATIONS A5.0 Spandrel Area Height = 4-8"' Length = 19'-0" -All signs will be made of individual channel letters -All signs will be facelit or nonlit -All signs will be flush mounted - no raceways -All signs will follow UDO sign standards 2/24/2025 LAKEFRONT COURT L A K E F R O N T C O U R T CARM E L D R I V E / / / / / / / / / / / / / / / / / / / / / / / / / / / //////////////////////////// / / / / /////////////////////////////// / / / / / / / / / / / / / / / / / / / / //////////////////////////// / /// / / / / / / / / / / / / / / / / / / ///////// / / / ////////////////////// / / / / / / / / / / DUMPSTER ENCLOSURE PROPOSED MEDICAL OFFICE BUILDING 1-STORY 8,100 SF 48.7'8. 4 ' 6.3' 62.8' 46 . 4 ' 71.1' 61.7' 3.7' 21 ' 58 . 7 ' 20' D.E. 20 ' D . E . 10 ' 3. 7 ' 18.3' PIV GENERATOR 18 ' 25 ' 18 ' 5 ' 5' 8 S P A C E S @ 9 ' = 7 2 ' 6 SPACES @ 9' = 54' 5 SPACES @ 9' = 45' 11 SPACES @ 9' = 99' 10.96' R 3 ' R1 5 ' R35' R 1 0 ' R3' R5' 10'25'18'5'8.46' 14 . 8 7 ' 4.88' 5' 5' 10.96' 5' 66.46' 9.0 3 ' 1 2 . 7 7 ' 8'8'8' 86 ' 4.5 9 ' A1 A A A B B C D D D E E F2 F1 F1 F1 F1 F1 G H I K K L L L L L L L L L L L L M N N P 6.4' 6' T T G1 VANVAN G1 T WARP CONCRETE TO TOP OF CURB, FLUSH O TAPER CURB TO EX. ROLL CURB, PATCH ASPHALT PER CARMEL ENGINEERING STANDARDS E E REPLACE EX. SIDEWALK PER CARMEL ENG. STANDARDS. E REPLACE EX. SIDEWALK PER CARMEL ENG. STANDARDS. CONSTRUCTION LIMITS CONSTRUCTION LIMITS 25 . 8 9 ' 22 . 7 3 ' E K 5' 15.88' 22.45' R R R R 5' U PROJECT NO. CHECK:DRAWN: PLAN DATE: DESIGN: STATE OF No. PE10707583 OO 14020 Mississinewa Drive Carmel, Indiana 46033 P: 317.324.8695 F: 317.324.8717 www.Fritz-Eng.com Fritz Engineering Services, LLC REVISIONS AND ISSUES BYDATE CLIENT: PROJECT: PROJECT LOCATION: GENERAL NOTES / LEGEND: SECTION, TOWNSHIP, RANGE: LAKEFRONT COURT 2 CARMEL SCIENCE & TECHNOLOGY PARK DAVID RAUSCH STUDIO 170 S. MAIN STREET ZIONSVILLE, IN 46077 5/18/2022 2204001 LAKEFRONT COURT CARMEL, INDIANA 46032 HAMILTON COUNTY NW 1 4, S36, T18N, R3E SHEET NAME SHEET NO. PREL I M I N A R Y NOT F O R CONS T R U C T I O N © 20 2 2 FR I T Z E N G I N E E R I N G S E R V I C E S , L L C C201 SITE LAYOUT PLAN 1.REV PER TAC COMMENTS 7/7/2022 AF AF AF KG 00 20'40' SCALE: 1" = 20' N "IT'S THE LAW" R Know what's below. Call before you dig. 2 WORKING DAYS BEFORE YOU DIG. KEY NOTES: A1 RIGHT OF WAY PAVEMENT (PER CARMEL DETAIL 10-22) A LIGHT DUTY ASPHALT PAVEMENT B HEAVY DUTY ASPHALT PAVEMENT C CONCRETE PAVEMENT, TYPE 2 D COMBINED CONCRETE CURB & WALK E CONCRETE WALK F1 6" CONCRETE CURB F2 VALLEY CURB & GUTTER F3 CHAIRBACK CURB & GUTTER F4 6" CONCRETE CURB WITH CONCRETE ISLAND G ADA RAMP (PER INDOT DETAIL) G1 ADA PARKING SIGN (PER DETAIL, VAN PLAQUE WHERE NOTED) H 4" WHITE PAVEMENT STRIPING, TYP. I ADA BLUE PAVEMENT STRIPING, TYP. J PAVEMENT MARKING (AS SHOWN) K MATCH EXISTING PAVEMENT, CURB, OR WALK L LANDSCAPE AREA M DUMPSTER ENCLOSURE (REF. ARCH. PLAN) N EXISTING SIDEWALK/PAVEMENT TO REMAIN O SIDEWALK TRANSITION AT DRIVE (PER INDOT DETAIL) P BICYCLE PARKING (U-SHAPED, BLACK THERMOPLASTIC POWDER COATED) Q FLUSH CURB / CURB TAPER R SITE LIGHT POLE (REF. SITE LIGHTING PLAN) T CONCRETE WHEEL BLOCK U DECORATIVE LANDSCAPE PLANTERS (COORDINATE TYPE/SIZE WITH OWNER) V W NOTES: XX SITE DEVELOPMENT SUMMARY TABLE ZONING CLASSIFICATION CITY OF CARMEL, M-3 PARCEL SIZE 0.96 Ac. ± (LOT 2) REQUIRED PROVIDED MIN. STREET FRONTAGE 100' FOR NON-RESIDENTIAL USE >150' MIN. LOT WIDTH N/A - - - MIN. LOT AREA 20,000 SF FOR NON-RESIDENTIAL USE 41,800 SF ± MAX. BLDG HEIGHT 50'35' MAX. MAX. LOT COVERAGE 80%58% BUILDING SETBACKS FRONT 20' PRINCIPAL BLDG 25' ACCESSORY STRUCTURES 22.4' (E) LAKEFRONT CT 22.7' (N) CARMEL DR 86' (S) LAKEFRONT CT SIDE 20' PRINCIPAL BLDG (NOT ABUTTING RESIDENTIAL) 5' ACCESSORY STRUCTURES N/A REAR 20' PRINCIPAL BLDG (NOT ABUTTING RESIDENTIAL) 5' ACCESSORY STRUCTURES 66.4' (W) PARKING SETBACKS FRONT 15' WHERE FRONT DOOR IS > 85' FROM R/W 13' EAST SIDE 15' WHERE FRONT DOOR IS > 85' FROM R/W 9' SOUTH REAR 25' WHERE FRONT DOOR IS > 85' FROM R/W 10' WEST BUFFERYARDS / GREENBELTS FRONT 15', CARMEL DRIVE 22.7' SIDE 5', LOCAL STREET 15.8' REAR 10', WEST BOUNDARY 10' PARKING REQUIRED, SF 1 PS PER 250 SF - OFFICE GENERAL 1 PS / 300 SF - PROFESSIONAL OFFICE PARKING REQUIRED OFFICE GENERAL 8,100 SF / 250 = 32 TOTAL REQUIRED SPACES PROFESSIONAL OFFICE 8,100 SF / 300 = 27 TOTAL REQUIRED SPACES 29 STANDARD + 3 ADA SPACES 32 TOTAL SPACES BICYCLE PARKING REQUIRED OFFICE - 1 BICYCLE SPACE PER 10,000 SF, MINIMUM OF 4 MULTI-TENANT BUILDING - 4 (TWO INVERTED 'U' LOOPS) NOTE: 1. CARMEL ENGINEERING DEPARTMENT NOTE ALL PAVING WITHIN THE EXISTING AND PROPOSED CITY RIGHT-OF-WAY SHALL CONFORM TO THE REQUIREMENTS OF THE DEPARTMENT OF ENGINEERING. THE CONTRACTOR SHALL CONTACT THE DEPARTMENT OF ENGINEERING TO SCHEDULE A PRE-CONSTRUCTION MEETING TO REVIEW THE DEPARTMENT'S CONSTRUCTION REQUIREMENTS, STAFF NOTIFICATION REQUIREMENTS, REQUIRED INSPECTIONS FOR CERTAIN STAGES OF THE WORK AND TO REVIEW THE AUTHORITY OF THE DEPARTMENT AS IT RELATES TO WORK WITHIN THE EXISTING AND PROPOSED RIGHT-OF-WAY. DRIVEWAY ENTRANCE SAW CUT NOTE DRIVEWAY ENTRANCE OFF OF LAKEFRONT COURT WILL REQUIRE SAW CUTS PER CITY OF CARMEL STANDARDS. ALL CURB CUTS MUST BE SAW CUT TO THE NEAREST JOINT PAST THE REQUIRED LIMITS OF THE CURB REMOVAL. SIDEWALK NOTE ALL SIDEWALKS CONSTRUCTED WITHIN THE PUBLIC RIGHT-OF-WAY SHALL COMPLY WITH STANDARD CITY OF CARMEL AND/OR INDOT DETAILS. GENERAL NOTES: REFER TO ARCHITECTURAL & FOUNDATION PLANS FOR ALL BUILDING DIMENSIONS. BUILDING DIMENSIONS SHOWN HEREON ARE FOR REFERENCE ONLY. NO EARTH DISTURBING ACTIVITY MAY COMMENCE WITHOUT AN APPROVED STORM WATER MANAGEMENT PERMIT FROM THE CITY OF CARMEL. PR I N T E D B Y : As h t o n F r i t z DA T E : 7/ 7 / 2 0 2 2 3 : 0 4 P M SH E E T S I Z E , S C A L E : AN S I F U L L B L E E D D ( 3 4 . 0 0 X 2 2 . 0 0 I N C H E S ) , 1: 1 FI L E N A M E : F: \ 2 0 2 2 \ 2 2 0 4 0 0 1 - L A K E F R O N T C O U R T 2 \ 0 2 C I V I L \ P L A N S \ C 2 0 1 . D W G , L A Y O U T : C2 0 1 2/24/2025 City of Carmel Department of Community Services Division of Planning & Zoning LETTER of GRANT February 24, 2025 Dr. Burke Chegar Chegar Facial Plastic Surgery 735 W. Carmel Drive Carmel, IN 46032 RE: Docket No. PZ -2025-00029 ADLS Amend-Sign: Lakefront Court II Sign Package Dr. Chegar, The Carmel Planning Department took the following administrative action regarding a Multi-Tenant Development Sign Package. The site is located at 735 W. Carmel Dr. It is zoned M-3 and is not located within an Overlay. APPROVED: PZ-2025-00029 ADLS Amend-Sign: Lakefront Court II Sign Package In order to assist the Department’s review, please attach a copy of this letter when submitting application for any permits regarding the improvements contained within this approval. Do not hesitate to contact me if I can be of further assistance. Sincerely, Aliza Shalit Sign Permit Specialist Department of Community Services 317.571.2417 ashalit@carmel.in.gov cc: File