CONSTRUCTION DESIGN RELEASE
State Form 41191 (R9/5-98)
Report Printed on: July 5. 2007
327126
Construction type
'SEE BELOW
Scope of release
07/05/07
Occupancy classification
CLASS C
Indiana Department of Homeland Security
DIVISION OF FIRE & BUILDING SAFETY
PLAN REVIEW DIVISION
402 W. Washington St., Room E245
Indianapolis, IN 46204
INDIANA 02
~ootQAQPO
ARCH ELEC
PLUM STR
FDN
MECH
To: Owner I Architect I Engineer
Gordon Clark, Architect AlA
Gordon E Clark 2537
4820 Buttonwood Crescent
Indianapolis IN 46228
SUPPORT HOOSIER SAFETY
Type of release
Standard
Project name
Renaissance Hotel Pool
Available At Your Local Licence Branch
Street address
11925 N Meridian St
Fax & e-mail: 3172525573, gclark4820@aol.com
Th~~lal!.~, sp_ecifi~~on~~?Q~tap.p.l;c~t_~on..~uJ.?!!.!.jJ~~JQrJ~_CP2.Y!~..Ee.~~f~nQ~d_p.roj~.l::~_have. been!_eviewe~lo! _compliance Y"it~_ the applicable rules of
t~e Fire Prevention and Building Safety Commission. The project is released for construction subject la, but not necessarily limited to, the conditions
listed below. THIS IS NOT A BUILDING PERMIT. ~II required I_Dca I permits ,and licenses must be obtained prior to beginning construction work. AU
construction work must be in full compliance with all applicableState';fules,.'Any changes in the released plans an:cUorsp_eCifications:must be filed with
and released by this Office before any work is altered.,This release may be,suspended or revoked if it is determined'to 6e issued in'error, in violation
of any rules of the Commission or if it is based on' i_n'cotfect or insufficient inform"ation. This release shall expire by:limiation, ,'and become null and
void, if the work authorized is not commenced -within one-(1) year from the above date.
CONDITIONS:
City
CARMEL
County
HAMILTON
, '
Note :(A 1A & A 1 B): In accordance_,~ith.-the affidavi_t swOrn under penalties of penury in the application for construction design releas~ the plans
and specifications filed ~n_ conjunction with this project_shall comply with all of the applicable rules and laws of Fire Prevention and Building Safety
Commission. Providing',false,h1formation constitutes an act of perjury, which is a:Class 0 felony punishableby a prison term and a fine up to $10,000.
r .
In accordance with.:,Secti9nJ~?f,th~_~eneral Admi!1istrative Rules (675 lAC 12-6-19) a complete set of plans and specifications that conform
exactly to the design:that was"r,eh~ased by the office of the state building commissioner shall be maintained on the construction jobsite as well as a
copy of the design-release.
I
19S203B All pools shall be' designed and constructed to withstand all anticipated loading for both empty and
full conditions in accordance with Rule 2, Section 3(a), IS PC (675 lAC 20-2-3).
The deck around the pool shall be of an impervious material and of a non-slip design in accordance
with Rule 2,Section 13(b), ISPC (675 lAC 20-2-13).
The deck around the pool shall be of an impervious material and of a non-slip design in accordance
with Rule 2,Section 13(b), ISPC (675 lAC 20-2-13).
poonfghling shall complywilh Rule 2, Section 22, Tspc (675'IAcio-2-22).
'9S213B
19S213B
'-
95222 .
Pool waste water shall be discharged into an acceptable sewage system in accordance with Rule 2,
Section 23, ISPC (675 lAC 20-2-23).
Bathhouse facilities shall be provided in accordance with Rule 2, Section 27, ISPC (675 lAC 20-2-
27).
3M0403B Supply air to a swimming pool and associated deck areas shall not be recirculated unless such air is
dehumidified to maintain the relative humidity of the area at or less than 60 percent in accordance
with Section 403.2.1,IMC (675 lAC 18-1.4).
3M0403C Supply air to a swimming pool shall not be recirculated to other spaces in accordance with Section
403.2.1, IMC (675 lAC 18-1.4).
Please be advised that if an administrative review of this action is desired, a written petition for review must be filed at the above address with the
Rre Prevention and Bunding Safety Commission identifying the matter for which a review is sought no later than eighteen (18) days from the above -
stated date, unless the eighteenth day falls on a Saturday, a Sunday, a legal holiday under State statute, or a day in wtrich the Department of Fire
and Building Services is dosed during nonnal business hours. In the latter case, the filing deadline will be the first working day thereafter. If you
choose to petition, and the before-mentioned procedures are followed, your petition for review will be granted, and an administrative proceeding will
be conducted by an administrative law judge of the Fire Prevention and Building Safety Commission. If a petjtion for review ts not filed, this Order will
be final, and you must comply with its requirements"
9S223
9S227
Page 1/2
Would you like to reduce your turnaround time?
ELECTRONICALLY FILE YOUR PROJECT WITH STATE OF INDIANA at http://www.in.gov/dhs/fire/branches/planJeview/index.html.
This on-line filing is through a secure site, you can use it to submit your project information, pay the fees and upload your project plans.
As of July 1, 2007 the existing e-flle site efile24 -7@dhs.in.gov will no longer be in service.
Filed By Code review official Code Enforcement & Plan Review Branch Director
GERALD KELLEY !J~d/S~
Address (name, title of local official,street,city,state and ZIP code
DEPT OF COMMUNITY SERVICE State Fire Marshal Vl~O~
JIM BLANCHARD
ONE CIVIC SQUARE
CARMEL, IN 46032
Fax & e-mail: 3175712499, iblanchard_@carmel.in.gov