HomeMy WebLinkAbout07070142 Site Plan
'=
~
Note:
This drawing is bosed on construction pions or record drawings,
and is not bosed upon 0 field survey. The Schneider Corporation
does not worront the accuracy or sufficiency of this information.
Contractors should verify existing conditions prior to any
construction. Any discrepancy found on this drawing' should be
reported to The Schneider Corporation immediately. Jomng to do
Plot Plan leQend so results in the contractors assumption of all liobmty.
~ Proposed Grades Note:
000.0 Existing Grodes
__000,0- Contour Grode The basement elevation, depicted hereon, hos been determined
* ~prox Lateral Location and based on the pod grades and/or contours taken from
- · - Sanitary Sewer Unes the construction pions for this subdivision. Unless stated, no
-a- Storm Sewer Unes
_ 'wi _ Water Servlce Lile9 information about fluctuating water tables, soil conditions, or
- - - - - - - Sub-Surface Drain Unes soil types has been provided or stated in said plans. This lot
. Manhole (Sanitary or Storm) is located near a body of water. Lot or soli conditions may
I ~-:Tr:I~tl(~t~)) require that the basement floor elevation be heid 2 foot
D End Section (Storm) above normal pool elevation. Site investigation may be
... Fire Hpant needed if water is encountered during the excavation process
- 00 0 - 0 0 0 - Flow l.i1e of sw<lle or if other known water elevation or soil conditions ore
present. Investigation and any remedial procedures I Is at the
discretion of the builder- to determine and take appropriote
steps of action. If any ground water is encountered during
excavation the builder is encouraged to contact The Schneider
Corporation to discuss possible courses of action.
The SehneJder Corporation
8901 ot.1J Avenue
m.t.oric Fort BarriJon
IndlaDapolll. indiana 48216-1037
317-826-7100
317-626-7200 fiX
EogIn......
SuneJlna
LandJcape ArchI.tect.ure
GIll.1JS
Geolao
This Plot Plan Prepared For:
R.H. of INDIANA
Lot # 110 , containing 5,400 SJ.:f:, in
Stanford Park Sec. 28
Instrument # 200600049043
Plot Cabinet 4, Slide 126
Hamilton County, Cloy Township
Sec. 29, ll8N, R3E
13448 CUPPERTlNO LANE (50' R/W)
Carmel, IN 46074
Prepared Date: 7-12-07 : By: SKN
Proposed Buyer(s): Paul L. and
Nancy J. Gitelsan
Community Restrictions:
Side Yard = 3'
Rear Yard = N/A
Aggregate = 6' B.H.
Zoning = R-2, ROSO
Finished Floor Elevation Information
Pad Grade = 915.6 per record drawing
Pod Grade + 0.7' = Garage m (916.5 )
Garage FFE + 1.5' = Residential FFE (916.0 )
Residential FFE - 9.0' = Basement FFE (909,0 )
Note : The garage tinished floor elevation
is 1.6' above the curb at the drive, per
plan.
Ground Cover Calculations:
Drive = 526 SF i
Pubiic Waik = 142 SFi
Private Walk = 36 sa
Hydroseeding =n/a SFi
Sod = 264 SYi, from
entire yard
914.0
3.3.6'
I
0 u.J I~
0
C> '"
.,-; ~
..... I'"
1eij
E~
21.7
94,0
... 21.2' I ~
Note: Sanitary Sewer
Top of Casting Information
Upstream Manhole, TC= 915.53
Downstream Manhole, TC=917.94
per record drawing
Note: The contractor is to maintain
a minimum distance of ten feet (10')
between the sanitary sewer and
water line loterals.
Sidewalk to be placed
online with property Une.
5' from bock of curb.
per plan.
UPSTREAM SANITARY MH NOTE
The upstream sanitary manhole
IC. elevation sholl be no less
than one foot (1'-0') beiow
residentiai FJ.E.
120,00'
4.5'
,Br'OB
LOT# 110
VB # 07.0076964
~
~
=~=
~
Assumed North
Scale: I' = 30'
Note: Sump pump(s) to be
placed by builder as needed.
Note: Builder to ensure
positive drainage away from
structure(s).
~III
'"
SIR. , 741
TC=917.94
PER RECORD
DRA\\ING
W
:z:
<:
--l
o
:z:
l-
e::: I
WI
0- I
=> I
01
CD
~
Y'
..,.
C>
.,-;
S~
m
'"
a
;;j
'"
9153
26.DJ6.0
u:
~
8
:sl m "j:::-;i
'81 ~~~ il\i5
i111 U~
:::1
,Lr'()jBf It
4.5
...,
"" I:~~ .
1!\lI ~
~~ ~
r ~ C>
00'6 e;-~
In "'::1
1;; ~ .....
tl OO'U g ,.
* '"
'"
915,3 36.0 9150
72.75 .0.
S1GNAlURE :
OATE:
S1GNAWRE REPRESENTS COHFIRWAll~ Cf RECEIPT Cf PlOT PLAN BY CUSTot.lER.
~
..,
:;;
.0
B-B
SIR. , 742
TC=915.53
PER RECORD
DRA\\ING
FLOOD HAZARD STATEMENT
CERTIFICATION
,,\1\\\\\111111/111/11////1.
~\'\~ l. a ~/~
~~~ ...""",....,:fc:0Y<<
~ t..~ .....G\s T~IT ......... A~
* ~-.....;..,~<:" No ~<)"" ":A?~
gg ~:' .... ~
- . . -
~.: I i 50303 ) I
:::I -' . _
b ...a % .... STATE OF .... $
., OP ;!. . V~ ~ ..... .... ~
'*'~ ".!.~OIA~,!:,."~~
'M'ICAL SWALE SECTION '% /IfJ S'.'u"'ii\\ \. ~ #
~/, l\"1 ~~\~
1//////1111/1111\\\\\\\\\\'
Oc-lf--r1
Note: This drawing is not intended to be represented os 0 retrocement or
originol boundary survey, a route survey, or 0 Surveyor Location Report.
Flood Hazard Statement: The accuracy of any flood hazard data shown on this report is subject
to mop scale uncertainty and to any other uncertainty in location or elevotion on the
referenced flood insurance rate mop. ALL of the within described land DOES NOT LIE within
that special flood hazard zone A os said land plots by scale on flood insurance rate map
#1B057C 0205F for the City of Carmel, Indiana (mops doted February 19, 2003).