Loading...
HomeMy WebLinkAbout05100118 Correspondence ,),ROM : ,~~ \. Jun. 26 2006 03:14PM Pi MAS ASSOCIATES, L.L.C An:hiteds and Planners 5200 East 64th street, Suite A Indianapolis, Indiana 46220 317 726 1060 i(f~~~~;~;:;;~;' ., Trnnsmittal '~",.;.';,'a{.:,,',<,.; ;...t>-"P;J~~' "'- .~ '" . ~*,': OS-I tJ 0 II g T~ Scott Krespa~ 581-5399 tf?~-,'1(~ 581-5355 ErnaR: From, Dave Swaim DalJe; 612612006 lie: GuUford Condos, Carmel Pages; I'rojeQ ~ ce: File /~ ,LRMM 3 2348.001 [J_~ O_AepIy O_~ . . . . . . . . . ~ AIIachei:l is Bill Spencers I\lSPOIIOO 10 Mr. Jill Ochs inspedion report thai was daled 6/16106. You .. . mlgIt want to do lhe garage door beam modillcaIion pliorW a re-illSIl8Cti01.. If you have allhe infillmallon thai you _ obllliIdllll in regaRls 10 1I\is same inspedion report, noIsd WlllI<done and1hl5lel1er, you should be able 10 sctleduIea re-irIspeCIiOI.. Please caD if you have 8Illf quesUons. .. . . . . 11 ., .. .. .. 11 11 11 11 11 .. .. . 11 11 11 . j!"ROM /~ " ! :--, FAX NO. 7261061 Jun. 26 2006 03: 15PM P2 /..-, //,"I'~' '-~"r;-'- > ,,~,~,\_C-11J- ,,< '.\- /i .......) .!I - --:;: ',\v/ /\0.~,...~.'.~,~._.~, .. sPlf/1llcn 6..'W.t;J/'t8UIJn;, IfIIt. Tel (am &<U_ Fa> (017) 668-lW'l 16liIWlli<oAfll11<. w__~- Ca:mad~ IN <66033 l~q-'-. gJ~.L1,- Ptojc!at M,ar-- ... St- -urd DtsIDeeftDl' -)00&-' ..... / June 26, 2006 Mr., David Swaim MAS Associa~es. LLC 5200 East 64th street, suite A Indianapolis, IN 46220 RE: Guilford Condos Guilford Ave. Carmel, IN Dear Dave: This is in response to your reque~t th~t I address several of the items contained in the inspection memo from James A. OChs, dated June 16, 2006 (Subject: 05100119, 70-120 Guilford)regarding the above referenced project. Based on our site visit on June 20, 2006 and subsequent drawing review and st~uctural analysis and my return visit earlier tOday, the following are my responses to 1ssues addressed in item 4 of l' Ochs memo: ~~. The framing fo~ the gable end truss were found to have been modified to include horizontal ~outri ersH between the bottom chord of the 9 e ~russ aD the bottom chord of the nearest adjacent roof truss. These consist of 2x4's spaced at approximately 16n on center. The ends of the outrigger~ are attached to continuous 2x4's'run parallel to and nailed to the bottom chords of the gable and interior roof tru8S~. The outriggerS cross over an ear 'rectly over t e x wall below. In a4dition. 2x4 diagonals have been run from each of the verticals of the gable truss downward to the top plate assembly to transfer load to the stud wall below. The 2xl2 plate that sits on the 2x4 wall top plates has 1/4"x6" lag screws attaching it through the 2x4 top plates into the studs and the 2x12 has metal straps anchoring its inside edge to the studs. ~aSed on my review, it 15 my opinion that the gable end wall is now adequately attacned and suppo~ted. I . - f"ROM Dave June Page JY' , '" ~~(-( rt\,J'1 (f' , \" '-'~ 'J/;;I' FAX NO, Jun. 26 2006 03:15PM P3 7261061 Swaim 26, 2006 2 of 2 As discussed on site, the engineer of record who performed a~d certified the original truss design is to be contacted and is to determine if the notched top chord requires any reinforcement. The floor truss that had the top chord cut out for a plumbing line has been repaired with the installation of a full depth wood panel gusset. It is my opinion that the repair is adequate. The garage door header is to be modified to include wood panel sheathing on the interior, extending from the bottom of the LVL header to the top of the double plate which is approximately 25" above the bottom of the LVL. The sheathing is to be attached to each of the plates, each of the cripple studs and the LVL header with 8d naIls spaced at 1~1/2" o.c. The exterior wood panel sheathing is to also receive additional nailing. The result will be a box be~ whose depth will be from the top plates to the top of door opening. 4e. The exterior balcony, as shown on the drawinqa, was checked for the code prescribed loads. The 3-1/2"xll~1/4" PSL joists spanning approximately Z4~eet ana $paced at 16" o.c., the 3-1/2uxll~1/4" gi~ders spanning approximately 6 feet pe~endicular to the wall and the 4"x4" exterior posts were all determin he de a lied T e ramer was advised that the gir er en s adjoining the building wall should be supported by three wall studs. Hopefully this provides the information If furthe~ information or clarification me know at your convenience. you need at this time. is required, please let \\\\\'''111'",1. ~''''',,\Y\OMAS """"" ~ 4.. ...~~"4... S)).......''- S;:;;. _.::~GlSr~f:j~c~~ 0.:;"::'..;: i'-C- N 'o--~-=- ~'Q : 0 ':. ~~ :::. . l ~~ ~ { 20751 ) ~ ~~\ srA.reOF ltZi '" "}.'..,,,, : /jS;;, ~ <;;.r.s....-t~~.~!~(}~:S' "-'-.,/ONAL ~"',# '11';,1,,,'\\\ Sincerely, .w.' ~~< spen~Engineering, Inc. Billy T. Spencer, P.E. '" I' {