Loading...
HomeMy WebLinkAbout05120073 Correspondence _......,..I.,C..,C "-,..' . ~ -' " , "_' 1 People Helping People Build a Safer World'" II' ~ · PRESIDENT HENR'f l. GREEN hecutiveDirector Bureau of Construction Codes & Fire Safety Michigan Dept.of labor & Et:onomic Growth lansing,Michigan VlctPRESIDENT WALLYBAILEY,C.B.O. Director. Development and Construction ft. Smifh,Arkansas SECRHARYITREASURER STEVEN L SHAPIRO, C.B.O. OireclorolCodesCcmpliance Hampton, Virginia IMMEOIATE PAST PRESIDENT FRANK P. HODGE,JR., C.B.D" M,C,P. Directllfof Building and Fire Codes Hilton Head Mend, South Carolina EDWINM.BERKEL,C.F.I. Fire Marshal Mehlvil!eFireProtectionOistrict St. louis, Missouri JAMES L.BROTHERS Building Director Decatur,A/abama TERRENCEl.COBB,C.B.D. Director, Dept. of Codes Administration NashVllle/Oeyidson County, Tennessee JOHN DARNALL. C.B.O. Assistant Director 01 DevelopmentServlcBS Tumweter, Washington WilLIAM L. DUCK, JR. C.B.O. Oire~tor. Dept. of Inspections and Code Columbus, Georgia WlllIAMD.DUPLER BuildingOflicial Chesterfield, Virginia GERALDD.GEDRGE,C.B.O. GhielBuildingOfficial Boulder County, Coloredo GREG JOHNSON Building Inspector SeinrPaulMinnesota JOHNT.laTORRA Building & Inspection Manager Redwood my, Californie RONALD LLYNN BuifdinllOfficial ClarkCounty,Nevada RDNAloE.PIESTER,R.A. Oirector, Division 01 Gode Enlorcement and Administration StataolNewYork Albany,NewY()rK JAMES T. RYAN,C.B.O. GodesAdministrator Over/and Par*, Kansas KEVINH.SCDTT Deputy Fire Chial 01 Kern Gounty Bakersfield, California ADOLF A. ZUBIA Fire Ghiaf lasCfIlces, New Mexico CHIEF EXECUTIVE OFfiCER JAMESL.WITT . I Chicago DistriCt Office 4051 W. Flossmoor Road. Country Club Hills, IL 60478-5795 U.S.A. Tel: +1 (708) 799-2300 . Fax: +1 (708) 799-4981 Toll Free: +].888-ICC-SAFE (422-7233) .1 www.lccsafe.org I I I I , March 6, 2006 . James Ochs, C.B.O. City of Carmel Department of Community Services One Civic Square Carmel, IN 46032 i1 0 5" \ '2 Q()7 j Sections 714.1and 714.2 of the 2003 International Building Code Dear Mr. Ochs: RE: This letter is in response to your question concerning the protection of structural elements that support fire-resistance rated construction. Based on your letter of February 14, 2006 and its attachment, your question, as I understand it, is: Given a fully suppressed, 4-story office building of Type liB construction, what portion, if any, of adjacent construction is required to be fire- resistance rated in the following two instances? Condition 1: The 2-hour vertical exit enclosures in this building are constructed of metal studs and gypsum board. In each story the stair enclosure walls (fire barriers) are supported on the floor slab. Response: Structure that directly supports fire barrier walls must be protected to the same degree as the fire barriers supported. In a steel frame building, the protection need not extend beyJllliJ the ~tructural bay containing the fire barrier. stair enclosure, shaft, etc. Protection shall include beams, girders, columns and the floor deck within the structural bay containing the protected elements. This requirement applies regardless of construction type or sprinkler suppression. Condition 2: Other 2-hour shaft enclosures in this building use a gypsum shaft wall assembly that is continuous from the slab on grade to the roof deck. The shafts are not supported on intermediate floors but they are laterally braced to the adjacent construction Response: In this case, the entire gravity load of each shaft bears only on the grade slab. Neither the surrounding construction nor the lateral bracing elements need protection. The gypsum assembly must not exceed the unsupported height limitation specified by the gypsum manufacturer. We are pleased to provide you with the opinions stated herein. They are based solely on information that you have provided. We have made no independent effort to verify the accuracy of this information nor have we conducted a review beyond the scope of your question. Understand that the final interpretation is always the legal responsibility of the authority having jurisdiction. ~~ '\'hi:iP Hahn, LA Senior Staff Architect Headquarters: 5203 Lecsburg Pike, Suite 600 . Falls Church, VA 22041-3405 U.S.A. Tel: +1 (703) 931-4533 . Fax: +1 (703) 379-1546 Toll Free: +1-888-ICC-SAFE (422-7233)