HomeMy WebLinkAbout07080034 Site Plan
~~
Schneider
The Schneider Corporation
8901 0tiII Avenue
Historic Fort 8arrlaon
Ind!aIlapoIls. IDdiana <821'-1037
317_-7100
317-826-7200 FAX
EngiIleerlDg
SuneJl>&
~Arohitecturo
GIS'LIS
GooIogy
This Plot Plan Prepared For: Arbor Homes
Lot # 20 ,contoinin9 13,160 SJ.:l:, in
The Trails at Hayden Run Sec. 1
INSTR. # 200500069468
Clay Twp, Hamilton County
Sec 20, T29N, R3E
3168 WININGS LANE (SO'R/W)
Westfield, IN 46074
Prepared Date: 07/19/07: By: KAG
Community Restrictions:
Side Yard =3' min.
Rear Yard = N/A
Aggregale = 6 (S.H.)
ARBOR HOMES
Pod Grode = 921.0 per plan
Pod Grode + 1.0' = Garage FFE (922.0)
Garage FFE + 0.5' = Residential FFE (922.5)
Residential FFE - 10.0' = Basement FFE (912.5 )
Driveway Slope = 3.9%
Note: The garage finished floor elevation
is 1.4' above the curb at the drive, per
plan.
GROUND COvtR CALCULAll0NS:
Orive = 861 SF:!:
Public Walk =390 SF:!:
Private Walk = 128 SF:!:
Seedin9 = 4,855SF:!:
Sod = 4 715 SF:!: ,
even with the rear of house.
Note: Builder to ensure positive
drainage away from structure(s).
VACAll0N FOR THE STULTZ & ALMOND LEGAL DRAIN
EASEMENT DATED JANUARY 9TH, 2006.
M.H.1611
TC=920.55
PER RECORO
ORA'MNG.
FLOOD HAZARD STATEMENT
CERnFICA nON
,\1\\\\\111111/1//1/11////
,,,,","\\\<:. L /l //00;
~'~~ . viP/~ ~
#~""(;\S'fEi?~',~
{tc::::;,...."""- No o....;c~
--I ( 50303 \ I
% . STATE OF. Z
~ <,,;~~..!IyDI A~!:,'''''~g
%;1:1 "'S'UR~~~~
1///11/1/1/11111111\\\\\\\\
-\.:l:-lf-rl
Note:
This drawing is based on construction pions or record drawings.
and is not based upon a field survey. The Schneider Corporation
does not warrant the accuracy or sufficiency of this Information.
Contractors should verify existing conditions prior to ~ny
construction. Any discrepancy found on this drawing S;hould
be reported to The Schneider COI'poratlon immediatelY, faRing
to do so results in the contractors assumption of oUr liability.
Plot Plan legend
Note:
[]Q[Q] Proposed Grades The basement elevation, depleted hereon, has been determined and
000.0 Existing Grades based on the pad grades and/or contou~ taken from the construction
- 000.0-- Contour Grade plans for this subdivision. Unless stated. no information about fluctuating
* Approx. Lateral location water tables. soD conditions, or soR types has been provided or stated
- . - Sanitary Sewer Lines on said pions. This lot is located near a body of water. Lot or SOIl
- If - Storm Sewer Unes conditions may require that the basement floor e1e'<<ltlon be held 2 foot
- 'J - Water Service Lines above normal pool elevation. SIte investigation may be needed If water Is
- - - - - - - Sub-Surface Drain Lines encountered during the excavation process or jf other known water
8 Manhole (Sanitary or Storm) elevation or soDs condlUons are present. Investigation and any remedial
. Beehive Inlet (Storm) procedures Is at the discretion of the bunder to determine I and toke
tmI Curb Inlet (Storm) appropriate steps of action. If any ground water is encountered during
D End Section (Storm) excavatlon the buDder Is encouraged to contact The Schneider
..... Fire Hydrant Corporation to dlsctJBS possible courses of action.
- 0 0 0 _ 0 0 0 - Flow Line of swale NOTE:
SUMP PUMP(S) TO BE PLACED
BY BUILDER AS NEEDED.
LOT # 20
VB # 07.0077221
Note: Sanitary Sewer
Top of Costing Information
Upstream Manhole, TC= 92D.55
Downstream Manhole, TC=921.45
per record drawing.
Note:
The contractor is to maintain a
minimum distance of ten feet (10')
between the sanitry sewer and water
line laterals.
...
...
1919.0 I
1&00 .
~ SUNROOW
11.69'
MCKINlEY B
fRIj!cMSY
RE~OENCE
POR
~
r-
25' 8L.
f'
20' D.U,&S.S.E.
. .
94.00'
I
<
0:;
N
'"
5' WAlJ(
<
41.7
94,00'
<=>
,..;
a;
DECK
J 10.98.
.. 14.33
SUM
PUMP
soo
~
!='
o
q
,..,
~
~
3 '
10.00
4.5'
.
8
d
N
lHREE CAR
GARAGE
,.., <
~
~
32.00'
"" CONC
26.0' );RIIt:
36.~
16'
lliV=920.6
PER PlAN
30.0'
B-B
5.0'
PER PlAN
(920.70)
WININGS LANE
\I
\I
RE\1S1ON 11
RE\1SED HOUSE PER FAX
1Il07.oo77623
07/24/07 - KAG
This drawing is not intended to be represented as a retracement or
original boundary survey, a route survey, or a Surveyor Location Report
Flood Hazard Statement: The accuracy of any flood hazard data shown on this report
is sub}ect to map scale uncertainty and to any other uncertainty in location or
elevation on the referenced flood Insurance rate map. ALL of the within descnbed land
DOES NOT UE within that special flood hazard zone A as said land plots by scale on
flood Insurance rate map # 18057C0205F for City of Carmel, IndIana (mops dated
February 19, 2003).
\I
\I
ij
D
=Ji:3.=
ij
Assumed North
Scale: I" = 30'
...-
\
, -
~.
:;
b
:1 .. ~t
- .,
TYPICAL SWALE SECTION
Note:
Per Carmel zoning ordinance 26.1.1 : The residentlal
district limits height to twenty-five feet (25'), however
a dwelling may be Increased in height to thirty-five
feet (35') provided the side and rear yards are increased
on additional one foot (1') for each on. foot (r) the
structure exceeds the firet twenty-five feet (25') In
height