Loading...
HomeMy WebLinkAbout07080034 Site Plan ~~ Schneider The Schneider Corporation 8901 0tiII Avenue Historic Fort 8arrlaon Ind!aIlapoIls. IDdiana <821'-1037 317_-7100 317-826-7200 FAX EngiIleerlDg SuneJl>& ~Arohitecturo GIS'LIS GooIogy This Plot Plan Prepared For: Arbor Homes Lot # 20 ,contoinin9 13,160 SJ.:l:, in The Trails at Hayden Run Sec. 1 INSTR. # 200500069468 Clay Twp, Hamilton County Sec 20, T29N, R3E 3168 WININGS LANE (SO'R/W) Westfield, IN 46074 Prepared Date: 07/19/07: By: KAG Community Restrictions: Side Yard =3' min. Rear Yard = N/A Aggregale = 6 (S.H.) ARBOR HOMES Pod Grode = 921.0 per plan Pod Grode + 1.0' = Garage FFE (922.0) Garage FFE + 0.5' = Residential FFE (922.5) Residential FFE - 10.0' = Basement FFE (912.5 ) Driveway Slope = 3.9% Note: The garage finished floor elevation is 1.4' above the curb at the drive, per plan. GROUND COvtR CALCULAll0NS: Orive = 861 SF:!: Public Walk =390 SF:!: Private Walk = 128 SF:!: Seedin9 = 4,855SF:!: Sod = 4 715 SF:!: , even with the rear of house. Note: Builder to ensure positive drainage away from structure(s). VACAll0N FOR THE STULTZ & ALMOND LEGAL DRAIN EASEMENT DATED JANUARY 9TH, 2006. M.H.1611 TC=920.55 PER RECORO ORA'MNG. FLOOD HAZARD STATEMENT CERnFICA nON ,\1\\\\\111111/1//1/11//// ,,,,","\\\<:. L /l //00; ~'~~ . viP/~ ~ #~""(;\S'fEi?~',~ {tc::::;,...."""- No o....;c~ --I ( 50303 \ I % . STATE OF. Z ~ <,,;~~..!IyDI A~!:,'''''~g %;1:1 "'S'UR~~~~ 1///11/1/1/11111111\\\\\\\\ -\.:l:-lf-rl Note: This drawing is based on construction pions or record drawings. and is not based upon a field survey. The Schneider Corporation does not warrant the accuracy or sufficiency of this Information. Contractors should verify existing conditions prior to ~ny construction. Any discrepancy found on this drawing S;hould be reported to The Schneider COI'poratlon immediatelY, faRing to do so results in the contractors assumption of oUr liability. Plot Plan legend Note: []Q[Q] Proposed Grades The basement elevation, depleted hereon, has been determined and 000.0 Existing Grades based on the pad grades and/or contou~ taken from the construction - 000.0-- Contour Grade plans for this subdivision. Unless stated. no information about fluctuating * Approx. Lateral location water tables. soD conditions, or soR types has been provided or stated - . - Sanitary Sewer Lines on said pions. This lot is located near a body of water. Lot or SOIl - If - Storm Sewer Unes conditions may require that the basement floor e1e'<<ltlon be held 2 foot - 'J - Water Service Lines above normal pool elevation. SIte investigation may be needed If water Is - - - - - - - Sub-Surface Drain Lines encountered during the excavation process or jf other known water 8 Manhole (Sanitary or Storm) elevation or soDs condlUons are present. Investigation and any remedial . Beehive Inlet (Storm) procedures Is at the discretion of the bunder to determine I and toke tmI Curb Inlet (Storm) appropriate steps of action. If any ground water is encountered during D End Section (Storm) excavatlon the buDder Is encouraged to contact The Schneider ..... Fire Hydrant Corporation to dlsctJBS possible courses of action. - 0 0 0 _ 0 0 0 - Flow Line of swale NOTE: SUMP PUMP(S) TO BE PLACED BY BUILDER AS NEEDED. LOT # 20 VB # 07.0077221 Note: Sanitary Sewer Top of Costing Information Upstream Manhole, TC= 92D.55 Downstream Manhole, TC=921.45 per record drawing. Note: The contractor is to maintain a minimum distance of ten feet (10') between the sanitry sewer and water line laterals. ... ... 1919.0 I 1&00 . ~ SUNROOW 11.69' MCKINlEY B fRIj!cMSY RE~OENCE POR ~ r- 25' 8L. f' 20' D.U,&S.S.E. . . 94.00' I < 0:; N '" 5' WAlJ( < 41.7 94,00' <=> ,..; a; DECK J 10.98. .. 14.33 SUM PUMP soo ~ !=' o q ,.., ~ ~ 3 ' 10.00 4.5' . 8 d N lHREE CAR GARAGE ,.., < ~ ~ 32.00' "" CONC 26.0' );RIIt: 36.~ 16' lliV=920.6 PER PlAN 30.0' B-B 5.0' PER PlAN (920.70) WININGS LANE \I \I RE\1S1ON 11 RE\1SED HOUSE PER FAX 1Il07.oo77623 07/24/07 - KAG This drawing is not intended to be represented as a retracement or original boundary survey, a route survey, or a Surveyor Location Report Flood Hazard Statement: The accuracy of any flood hazard data shown on this report is sub}ect to map scale uncertainty and to any other uncertainty in location or elevation on the referenced flood Insurance rate map. ALL of the within descnbed land DOES NOT UE within that special flood hazard zone A as said land plots by scale on flood Insurance rate map # 18057C0205F for City of Carmel, IndIana (mops dated February 19, 2003). \I \I ij D =Ji:3.= ij Assumed North Scale: I" = 30' ...- \ , - ~. :; b :1 .. ~t - ., TYPICAL SWALE SECTION Note: Per Carmel zoning ordinance 26.1.1 : The residentlal district limits height to twenty-five feet (25'), however a dwelling may be Increased in height to thirty-five feet (35') provided the side and rear yards are increased on additional one foot (1') for each on. foot (r) the structure exceeds the firet twenty-five feet (25') In height