HomeMy WebLinkAbout07080075 Site Plan BUCKINGHAM - ELEV 4C RIGHT HAND - Full Brick FULL BSMT - 9' Walls 3 CAR - Side Entry Wd Deek "1" Gar. FFE = 777.1 151 Fir FFE = 779.0 TOW = 778.0 Bsmt FFE = 769.1 Drive Slo e = 2.8% "BASE HOUSE STANDARD FEATURES" 9' FULL BASEMENT 3 CAR SIDE ENTRY GARAGE BRICK 3 SIDES PATIO (2) 4X4 WINDOW WELLS & (1) 2X2 WINDOW WELL "SELECTED FEATUR BRICK 4 SIDES DECK ~1' (3) 4X4 WINOOW WELLS am Note: Minimum Front yard * 25' Minimum Side Yard - 3' Minimum Aggregate - 6' (Between Houses) Minimum Rear Yard - N/A &~~QJ][J\Jj)@@J [f!J@[]'\'(DD @@(X!D@g 1]" = ~@' # 219 19 SF ~ ;: . ~I >l 2.5' 1-- ~I 'Ii Ii 0:: ~ I " 0 ~" . - ./ ::JU I 0 ~. z~ O~ <X) :;CS I ",- 0 O~ ~ en " " oj < I . u " 0 ;: 8~ I ~ . I R ~ ci c5a::G ,.. '" 00 w<!~ " en UJ I :g ~ I z ~ ::J 0- I W01 I ~ tr UJ o..-.;t -.... l- I ~ ;: 20' z 0 ~ "1 < 75. tr UJ ;: UJ '" Z <( '" SAN MH 746 TC=777.08 IZK:xI = Proposed Grade _ = Drainage Flow xx.x = Existing Grade Flood Hazard Note: lot Number 21 9 lies within Flood Hazard Zone "X. per the scaled location on the Flood Insurance Rate Maps for Hamilton County, Indiana (Community Panel #18057C0235F, dated February 19,2003). Note: This drawing is based upon construction plans and/or record drawings prepared by others and Is not based upon a field survey. COOR Consulting & Land Services, Corp. does not warrant the correctness or integrity of lhis information. The contractor/owner should verify existing conditions prior 10 construction. Any varying fiald conditions or any discrepancy with the information contained hereon should be Immediately reported to COOR Consulting & Land Services, Corp.; failure to do so would result in the contractor/owners assumption of liablllty. ~oor. @@IlD@l\OD\l~IlD\W &:r DIIDIlD@] @@G'~a@@@9 @@Il'IP@Il'IID\l~@rru 303 WEST MAIN STREET KNIGHTSTOWN. INDIANA (888) 593-2667 (765) 345-5943 FAX#: (765) 345-5692 DATE: 08/07107 JOB #2003-100.219 REVISIONS: ~ 140.00' Cone Flatwork Sq. Ft = f1570 Public Walk Sq Ft = f410 Sod Sq Yds = f346 Seedin9 Sq Ft = f6506 Note: Contractor should verify site specific infonnation depicted hereon with the approved construction plans for this development. Also, Contractor should reference Architectural plans for foundation orientation and dimensions. Note: The proposed cOflstructjon grades, contours, and proposed structure elevations as depicted hereon are based upon information provided upon the approved construction documents prepared for this development. Unless otherwise staled hereon, no information pertaining to but notlimlled 10, nuctuating water tables elevations, soil types, and conditions within the buiIClng areas of this development have been provided and \or referenced on said documents. With the excavation of the proposed structure foundations. certain care and observations should be made in regard to such cOflditions as soil types and fluctuating water tables. During the excavation process should any unsuitable soils or ground water be witrlessed, the builder shall be immediately notified for further examination and consultation. At the builders discretion, additional construction techniques may be necessary to alleviate future problems. @[){j~rnlOOV @OO~~C;Z; [g~V&'jj'~~ ~[;;@"u'lJ@11tJ ~ INSTR #200500009933 PC 3, SliDE 580 C.O.C.#200500011991 PLOT PLAN Prepared Fo~ LOT # 219 14093 PECOS COURT CARMEL, IN 46033 Pulte Homes of Indiana ~