HomeMy WebLinkAbout07080075 Site Plan
BUCKINGHAM - ELEV 4C
RIGHT HAND - Full Brick
FULL BSMT - 9' Walls
3 CAR - Side Entry
Wd Deek "1"
Gar. FFE = 777.1
151 Fir FFE = 779.0
TOW = 778.0
Bsmt FFE = 769.1
Drive Slo e = 2.8%
"BASE HOUSE STANDARD FEATURES"
9' FULL BASEMENT
3 CAR SIDE ENTRY GARAGE
BRICK 3 SIDES
PATIO
(2) 4X4 WINDOW WELLS & (1) 2X2
WINDOW WELL
"SELECTED FEATUR
BRICK 4 SIDES
DECK ~1'
(3) 4X4 WINOOW WELLS
am
Note:
Minimum Front yard * 25'
Minimum Side Yard - 3'
Minimum Aggregate - 6'
(Between Houses)
Minimum Rear Yard - N/A
&~~QJ][J\Jj)@@J [f!J@[]'\'(DD
@@(X!D@g 1]" = ~@'
# 219
19 SF
~
;: .
~I >l 2.5'
1-- ~I 'Ii Ii
0:: ~ I "
0 ~" . - ./
::JU I 0 ~.
z~
O~ <X) :;CS
I ",- 0
O~ ~ en " " oj
< I . u " 0
;: 8~ I ~ . I R ~ ci
c5a::G ,.. '" 00
w<!~ " en
UJ I :g ~ I
z ~
::J 0- I
W01 I ~
tr
UJ o..-.;t -....
l- I
~
;: 20'
z
0
~
"1 <
75.
tr
UJ
;:
UJ
'"
Z
<(
'"
SAN MH 746
TC=777.08
IZK:xI = Proposed Grade
_ = Drainage Flow
xx.x = Existing Grade
Flood Hazard Note:
lot Number 21 9 lies within Flood Hazard Zone "X. per the
scaled location on the Flood Insurance Rate Maps for
Hamilton County, Indiana (Community Panel #18057C0235F,
dated February 19,2003).
Note:
This drawing is based upon construction plans and/or record
drawings prepared by others and Is not based upon a field survey.
COOR Consulting & Land Services, Corp. does not warrant the
correctness or integrity of lhis information. The contractor/owner
should verify existing conditions prior 10 construction. Any varying
fiald conditions or any discrepancy with the information contained
hereon should be Immediately reported to COOR Consulting & Land
Services, Corp.; failure to do so would result in the contractor/owners
assumption of liablllty.
~oor.
@@IlD@l\OD\l~IlD\W &:r DIIDIlD@] @@G'~a@@@9
@@Il'IP@Il'IID\l~@rru
303 WEST MAIN STREET KNIGHTSTOWN. INDIANA
(888) 593-2667 (765) 345-5943 FAX#: (765) 345-5692
DATE: 08/07107 JOB #2003-100.219 REVISIONS:
~
140.00'
Cone Flatwork Sq. Ft = f1570
Public Walk Sq Ft = f410
Sod Sq Yds = f346
Seedin9 Sq Ft = f6506
Note:
Contractor should verify site specific infonnation depicted
hereon with the approved construction plans for this
development. Also, Contractor should reference Architectural
plans for foundation orientation and dimensions.
Note:
The proposed cOflstructjon grades, contours, and proposed structure
elevations as depicted hereon are based upon information provided
upon the approved construction documents prepared for this
development. Unless otherwise staled hereon, no information
pertaining to but notlimlled 10, nuctuating water tables elevations,
soil types, and conditions within the buiIClng areas of this
development have been provided and \or referenced on said
documents. With the excavation of the proposed structure
foundations. certain care and observations should be made in regard
to such cOflditions as soil types and fluctuating water tables. During
the excavation process should any unsuitable soils or ground water
be witrlessed, the builder shall be immediately notified for further
examination and consultation. At the builders discretion, additional
construction techniques may be necessary to alleviate future
problems.
@[){j~rnlOOV @OO~~C;Z;
[g~V&'jj'~~
~[;;@"u'lJ@11tJ ~
INSTR #200500009933
PC 3, SliDE 580
C.O.C.#200500011991
PLOT PLAN
Prepared Fo~
LOT # 219
14093 PECOS COURT
CARMEL, IN 46033
Pulte Homes of Indiana
~