HomeMy WebLinkAbout07080108 Site Plan
[]QQ]] Proposed Grades
000.0 Existing Grades
___ 000.0- Contour Grode BASEMENT NOTE
* Approx. Lateral Location The basement elevation, depicted hereon, has been
- · - Sanitary Sewer lines determined and based on the pod grades and/or contours
-It - Storm Sew~r U~es token from the construction pions for this subdivision.
-~-WoterSer.1ceL"es UI ttd .f r b tfl t r t
_ _ _ _ _ _ _ Sub-Surface Drain Lines n ess 5 ~ e , n? In orma IO~ (] au uc uo Ing WO, er
. Manhole (Sanitary or Storm) tobles, 5011 conditions, or 5011 twes has been proVIded or
. Beehive Inlet (Storm) stated on sold plans. This lot is located near 0 body of
IIlI Curb Inlet (Storm) water. Lot or soil conditions may require that the
D End Section (Storm) basement floor elevation be held two feet (2'-0") above
..... Fire H~ront normal pool elevation. Site investigation moy be needed if
- 0 C 0 - 000 - Fl~w ,Line ,of swale water is encountered during the excavation process or if
BUilding Lln~ (BL / BSL) other known water elevation or soils conditions ore present.
- - - - - - - Easement line Investigation and any remedial procedures are at the
discretion of the builder to determine and take appropriate
steps of action. If ony ground water is encountered
during the excavation the builder is encouraged to contact
The Schneider Corporation to discuss possible courses of
action.
~
~~
Schneider
Tbe Schneider Corporation
8901 OUI Avenue
m.toric Fort Harrison
IndlAllapolil, Indlana l62l6-103'l
317-826-7100
317-626-7200 FAX
EDlInHl'l!ll
SIlrTeJU>i
lAndJeape Archit.ecture
GI3 .1J3
GeololY
Plot Plan Legend
This Plot Plan Prepared For. R.H. of Indiana
Lot # 975 . containing 6,490 S.F.:!:, in
VIllage of Westclay
Section # 6002
INSlR. , 200500080673
PC 3, SUDE 791
REPlAT INSlR. , 200600008945
PC 4, SUOE 31
HomDton County. Cay Twp
Sec 19, naN, ROJE
2444 Buckland Street
Carmel, IN 46074
Prepared Date: 08/02/07: By. AMA
Proposed Bu~s~INVENTORY
(50'RfW)
Community Restrictions:
Side Yard = S' MIN (ONE ~DE)
Rear Yard = N/A
Aggregate = 2D~ LOT \\lOTH, MIN. 5' ONE SIDE
Zoning = 51
Note: Sanitary Sewer
Top of Casting Information
Upstream Manhole, TC= 904.63
Downstream Manhole, TC= 905.97
per record drawing
Note: Builder to ensure positive
drainage away from structure(s).
R.H. of Indiana
Finished Floor Elevation Information
TBM at face of curb=902.6
TBM at 0Iley=905.0
~
TYPICAL SWALE SECTION
Proposed Grade at Swale=gOS.7, high side
Garage FIT at weotherllp=908.7-2.54=906.16
Residential FFE=905. 7+3.0=908. 7
Basement FFE=908.7-1O.0=898.7
Ground Cover Calculations:
Drive '; 581 SF f
Public Walk = 255 SF f
Private Walk = 39 SFf
Hydroseedin9 =N/A SFf
Sod = 329 Sri. entire yard.
Sidewalk to be placed
online with property line,
5.5' from bock of curb,
per plan.
Note:
The contractor is to maintain a minimum
distance of ten feet (10') between the
sonitary sewer and water I1ne laterals.
1.3
foo"'T"
,~~
7200 5.9
-U3
FLOOD HAZARD STATEMENT
CERTlFICA TlON
,\11\\\\\11111111111//11//1.
#~\\~ l. C}t~
~ ~ ........... ""'c0-~
~ ~...~G\S TE:".,;~.....y,<>~
~~ ...'1- No O......A:'"'"
, ( 50303 .\ ,
~ ~ ~ ~
% \. STATE OF ..... ~
~ ~;.......:.IItD' A\'\~.....~#
,<<-Y~ ..,....,.....{.'\"~
%/ij//. SUR~ ~\\\\#
W//IIIIIIIIIIIII\\I\""!
~lf1i
0.38'
~
'" 5.
Note:
This drawing is based on construction plans or record
drawings, and is not based upon 0 field survey: The
Schneider Corporation does not warrant the accuracy or
sufficiency of this information. Contractors should verify
existing conditions prior to any construction. Any
discrepancy found on this drawing should be reported to
The Schneider Corporation immediately; foiling to do so
results in the contractors assumption of all liability.
Note: SUmp pump(s) to be
placed by builder os needed.
~
~
=~=
Vb07.0077696
Lot # 975
~
Assumed North
Scale: I" = 30'
37.1 I
1.1'
~
.. !<i
32.00'
THREE CAR
GARAGE
~N
..rl.l')
NO
'"
~
~
...
N
19.33
~
~33' 1.33'
Wi2:tXi
~~: $;~8.
~ <i'" ~
7.~ 1;00'-
1.33 5.5
.33'
o ii
!g e!
~1
.33'
III
;:i
III
ill
SU~P
PU~P
2.96'
PORCH
THORNTON A
f1l~&lASY
RE~OENCE
III
~
...,
~
ill
II
.1
~
29.0'
B=8
J~UCKLAND STREET
This drawing is not intended to be represented os 0
retracement or original boundary survey, a route survey,
or a Suveryor Location Report.
Flood Hazard Statement: The accuracy of any flood hazard data shown on this report is subject to
map scale uncertainty and to any other uncertainty in location or elevation on the referenced flood
insurance rate map. ALL of the within described land DOES NOT tie within that special flOOd hazard
zone AE as said land plots by scale on flOOd insurance rate map #180081 0205 F for the City of
Carmel, Indiana dated February 19, 2003.
Note: Per Carmel zoning ordinance 26.U : The
residential district limits height to twenty-five
feet (25'), however a dwelling may be increased
in height to thirty-five feet (35') pro<lded the
side and reor ~rds are increased on additional
one foot (1') for each one foot (1') ths
structure exceeds the first twenty-five feet
(25') in height.
~GNA nJRE :
OArr:
~GNA nJRE REPRESENTS CON~RMA nON OF RECEIPT OF PLOT PlAN BY CUSTDlAER.