Loading...
HomeMy WebLinkAbout07080101 Site Plan .-""---. ~ Tbe Schneider CorporaUon 6901 OUI inDue Historic Fort Harrison lndluapolls. lnc11sn4 16216-1037 317-626-7100 317-828-7200 YAX En,lneeriDc ~ LandJcape Arehitecture GIS .IlS GeolO(}' Plot Plan Legend This Plot Plan Prepared For: R.H. of Indiana ~ ~;fft?;;dG~:~~:s Lot # 976 . containing 7,276 S.F.:!:. in .--000:0- Contour Grode VIllage of Westday * Appro,. Lateral Location Section' 6002 - 8 - Sonitory Sewer. Lines - 81' - Storm Sewer lines INSlR. , 200500080673 - ~ - water Service Lines PC 3 SUDE 791 - - - - - - - Sub-Surface Drain Lines ROOT INSlR. , 200600008945 : ~~~~i~~ I~T~nil~;~:) Storm) PC 4, SUDE 31 IIIIl Curb Inlet (Storm) HamHton Count~ Clay Twp 0 End Section (Storm) 19 T18N 03[' .... Fire H~ront Sec, , _ 0 0 0 _ 0 0 . - ~ow Line of swole 2432 Buckland Street (50'R/W) Building Line (BL / BSL) Carmel, IN 46074 - - - - - - - Easement Line Prepa(ed Date: 08/02/07: By. AMA Proposed Buyer(s): Leah & John Dunbar Community Restrictions: Side Yard = 5' MIN (ONE SIDE) Rear Yard = N/A Aggregote = 20~ LOT \\1oTH. MIN. 5' ONE SIDE Zoning = $1 Note: Sanitary Sewer Top of Casting Information Upstream Monhoie, TC= 914.63 Downstream Manhole, TC= 905. 97 per record drawing ~ R.H. of Indiana TYPICAL SWAL( SECTION Finished Floor Elevation Information TBM at face of curb=902.2 TBM ot 0Iley=904.6 Proposed Grade at Swale=905.2. high side Garage m at weatherlip=908.2-2.54=905.66 Residential m=905.2+3.o=9o8.2 Basement FFE=908.2-1D.0=898.2 Note: This drawing is based on construction plans or record drawings, and is not based upon a field survey. The Schneider Corporation does not warrant the accuracy or sufficiency of this information. Contractors should verify existing conditions prior to any cOflstruction. Any discrepancy found on this drawing should be reported to The Schneider Corporation immediately, failing to do so results in the contractors assumption of all liability. BASEMFNT NOTE The basement eleV<1tion, depicted hereon, has been determined and based on the pad grades and/or contours taken from the construction plans for this subdivision. Unless stated, no information about fluctuating water tables, SO~ conditions, or soil types has been provided or stated on said plans. This lat is located near a bady of water. lot or soil conditions may require that the basement floor elevation be held twa feet (2'-0") above normal pool elevation. Site investigation may be needed if water is encountered during the excal/Qtion process or if other known water elel/Qtion or solis conditions are present. Investigation and any remedial procedures are at'the discretion of the builder to determine and take appropriate steps of action. If any ground water is encountered during the excavation the builder is encouraged to contact The Schneider Corporation to discuss possible courses of action. Note: Sump pump(s) to be placed by bu~der os needed. Note: auader to tnS\.lfe positi\lt drainage away from structure(s). Ground Cover Calculations: Drive = 552 SF t Public Walk = B65 SFt Private Walk = 51 SFt H~roseeding =N/A SFt Sod = 491 SYt, entire yard. Sidewalk to be placed online with property line, 5.5' from bock of curt, per plan. Note: The contractor is to maintain 0 minimum distance of ten feet (10') between the sanitary sewer and water line laterals. FLOOD HAZARD STATEMENT CERTlFICA TlON ,,\\1\\\\\111111/11///11111. "v:.~\\ C. L ,,~I';0'lh ",' ':~ . v, '% ~ ~ '\ ........... ~~~ ff {~,,"{G\SNTE:~~..........A~ ::::::~..~v 0 0 ..~~ i ( S0303 '\ I % ..... STATE OF. ~ ~ /', .' ~ ~~ 4.i>:'A{DJA~!':""'~~ ~;:::t ''S'UR'~\'~ 11111/1//1/111\\1\\\\1\\1\ '\.:l'- l . P1i L 3275 ~ I- IR lliREE CAA in W "8N ~ GAAAGE ~ W .., ~ g: ~~ ~ m "8 b (,/) 1.33' l~ .33' 1.7'" Cl -7~ 1~~17.~ :z 13"13' <: ~ ~I ~ -' I"') ~ - PATIO ::.::: 'I ~ 12.36'J133' U .12.00' , 5.5 .33' 15.71' => 1.33 BSI.lNT CO I ~ I in PIERSON C 1<2 5 in :l1 ~ ~ FRM&MSY 1'.2 a :<l :<l III RE~DENCE ;;! I ~ SUMP "8 PUMP ~ I '" 13. II Vb07.0078021 Lot # 976 ~ ~ =~= ~ Assumed North Scale : ,. = 30' ) 111M EllV=9022 BUCKLAND STREET This drawing is not intended to be represented os a retracement or original boundary survey, a route survey, or a Suveryor location Report. Flood Hazard Statement: The accuracy of any flood hazard data shown on this report is subject to map scale uncertainty and to any other uncertainty in location or elevation on the referenced flood insurance rate map. ALL of the within described land DOES NOT lie within that special flood hazard zone AE as said land plots by scale on flood insurance rate map #1800810205 F for the City of Carmel, Indiana dated February 19, 2003. Note: Per Carmel zoning ordinance 26. t, 1 : The residential district limits height to twenty-five feet (25'), however 0 dwelling may be Increased In height to thirty-five feet (35') provided the side and rear yards ore Increased an additional one foot (1') for each one foot (1') the structure exceeds the first twenty-five feet (25') in height. SIGNA TIJRE : DAlE: SIGNA TIJRE REPRESENTS CONRRMA TION Of REOEPT Of PLOT PlAN BY CUSTOMER.