HomeMy WebLinkAbout07080101 Site Plan
.-""---.
~
Tbe Schneider CorporaUon
6901 OUI inDue
Historic Fort Harrison
lndluapolls. lnc11sn4 16216-1037
317-626-7100
317-828-7200 YAX
En,lneeriDc
~
LandJcape Arehitecture
GIS .IlS
GeolO(}'
Plot Plan Legend
This Plot Plan Prepared For: R.H. of Indiana ~ ~;fft?;;dG~:~~:s
Lot # 976 . containing 7,276 S.F.:!:. in .--000:0- Contour Grode
VIllage of Westday * Appro,. Lateral Location
Section' 6002 - 8 - Sonitory Sewer. Lines
- 81' - Storm Sewer lines
INSlR. , 200500080673 - ~ - water Service Lines
PC 3 SUDE 791 - - - - - - - Sub-Surface Drain Lines
ROOT INSlR. , 200600008945 : ~~~~i~~ I~T~nil~;~:) Storm)
PC 4, SUDE 31 IIIIl Curb Inlet (Storm)
HamHton Count~ Clay Twp 0 End Section (Storm)
19 T18N 03[' .... Fire H~ront
Sec, , _ 0 0 0 _ 0 0 . - ~ow Line of swole
2432 Buckland Street (50'R/W) Building Line (BL / BSL)
Carmel, IN 46074 - - - - - - - Easement Line
Prepa(ed Date: 08/02/07: By. AMA
Proposed Buyer(s): Leah & John
Dunbar
Community Restrictions:
Side Yard = 5' MIN (ONE SIDE)
Rear Yard = N/A
Aggregote = 20~ LOT \\1oTH. MIN. 5' ONE SIDE
Zoning = $1
Note: Sanitary Sewer
Top of Casting Information
Upstream Monhoie, TC= 914.63
Downstream Manhole, TC= 905. 97
per record drawing
~
R.H. of Indiana
TYPICAL SWAL( SECTION
Finished Floor Elevation Information
TBM at face of curb=902.2
TBM ot 0Iley=904.6
Proposed Grade at Swale=905.2. high side
Garage m at weatherlip=908.2-2.54=905.66
Residential m=905.2+3.o=9o8.2
Basement FFE=908.2-1D.0=898.2
Note:
This drawing is based on construction plans or record
drawings, and is not based upon a field survey. The
Schneider Corporation does not warrant the accuracy or
sufficiency of this information. Contractors should verify
existing conditions prior to any cOflstruction. Any
discrepancy found on this drawing should be reported to
The Schneider Corporation immediately, failing to do so
results in the contractors assumption of all liability.
BASEMFNT NOTE
The basement eleV<1tion, depicted hereon, has been
determined and based on the pad grades and/or
contours taken from the construction plans for this
subdivision. Unless stated, no information about
fluctuating water tables, SO~ conditions, or soil types has
been provided or stated on said plans. This lat is
located near a bady of water. lot or soil conditions may
require that the basement floor elevation be held twa
feet (2'-0") above normal pool elevation. Site
investigation may be needed if water is encountered
during the excal/Qtion process or if other known water
elel/Qtion or solis conditions are present. Investigation
and any remedial procedures are at'the discretion of the
builder to determine and take appropriate steps of action.
If any ground water is encountered during the excavation
the builder is encouraged to contact The Schneider
Corporation to discuss possible courses of action.
Note: Sump pump(s) to be
placed by bu~der os needed.
Note: auader to tnS\.lfe positi\lt
drainage away from structure(s).
Ground Cover Calculations:
Drive = 552 SF t
Public Walk = B65 SFt
Private Walk = 51 SFt
H~roseeding =N/A SFt
Sod = 491 SYt, entire yard.
Sidewalk to be placed
online with property line,
5.5' from bock of curt,
per plan.
Note:
The contractor is to maintain 0 minimum
distance of ten feet (10') between the
sanitary sewer and water line laterals.
FLOOD HAZARD STATEMENT
CERTlFICA TlON
,,\\1\\\\\111111/11///11111.
"v:.~\\ C. L ,,~I';0'lh
",' ':~ . v, '%
~ ~ '\ ........... ~~~
ff {~,,"{G\SNTE:~~..........A~
::::::~..~v 0 0 ..~~
i ( S0303 '\ I
% ..... STATE OF. ~
~ /', .' ~
~~ 4.i>:'A{DJA~!':""'~~
~;:::t ''S'UR'~\'~
11111/1//1/111\\1\\\\1\\1\
'\.:l'- l . P1i
L
3275 ~
I-
IR lliREE CAA in W
"8N ~ GAAAGE ~ W
.., ~ g:
~~ ~
m "8 b (,/)
1.33' l~ .33' 1.7'" Cl
-7~ 1~~17.~ :z
13"13' <:
~ ~I ~ -'
I"') ~ - PATIO ::.::: 'I
~ 12.36'J133' U
.12.00' ,
5.5 .33' 15.71' =>
1.33 BSI.lNT CO I
~ I
in PIERSON C 1<2 5 in :l1
~ ~ FRM&MSY 1'.2 a
:<l :<l
III RE~DENCE ;;! I
~
SUMP
"8 PUMP ~ I
'" 13.
II
Vb07.0078021
Lot # 976
~
~
=~=
~
Assumed North
Scale : ,. = 30'
)
111M
EllV=9022
BUCKLAND STREET
This drawing is not intended to be represented os a
retracement or original boundary survey, a route survey,
or a Suveryor location Report.
Flood Hazard Statement: The accuracy of any flood hazard data shown on this report is subject to
map scale uncertainty and to any other uncertainty in location or elevation on the referenced flood
insurance rate map. ALL of the within described land DOES NOT lie within that special flood hazard
zone AE as said land plots by scale on flood insurance rate map #1800810205 F for the City of
Carmel, Indiana dated February 19, 2003.
Note: Per Carmel zoning ordinance 26. t, 1 :
The residential district limits height to
twenty-five feet (25'), however 0 dwelling
may be Increased In height to thirty-five
feet (35') provided the side and rear yards
ore Increased an additional one foot (1') for
each one foot (1') the structure exceeds
the first twenty-five feet (25') in height.
SIGNA TIJRE :
DAlE:
SIGNA TIJRE REPRESENTS CONRRMA TION Of REOEPT Of PLOT PlAN BY CUSTOMER.